Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Measured electric field intensities near electric cloud discharges detected by the Kennedy Space Center's Lightning Detection and Ranging System, LDAR

For a summer thunderstorm, for which simultaneous, airborne electric field measurements and Lightning Detection and Ranging (LDAR) System data was available, measurements were coordinated to present a picture of the electric field intensity near cloud electrical discharges detected by the LDAR System. Radar precipitation echos from NOAA's 10 cm weather radar and measured airborne electric field intensities were superimposed on LDAR PPI plots to present a coordinated data picture of thunderstorm activity.

Poehler, H. A.↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase-to-phase-ground and phase-to-ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase-to-ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and nonfaulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

42 ENGINEERING↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase to phase ground and phase to ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase to ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and non-faulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/ Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

Piesciorovsky, Emilio↗

Near-Zero Power MOF-Based Sensors for NO 2 Detection

Detection and capture of toxic nitrogen oxides (NO x ) is important for emissions control of exhaust gases and general public health. The ability to directly electrically detect trace (0.5–5 ppm) NO 2 by a metal–organic framework (MOF)-74-based sensor at relatively low temperatures (50 °C) is demonstrated via changes in electrical properties of M-MOF-74, M = Co, Mg, Ni. The magnitude of the change is ordered Ni > Co > Mg and explained by each variant's NO 2 adsorption capacity and specific chemical interaction. Ni-MOF-74 provides the highest sensitivity to NO 2 ; a 725× decrease in resistance at 5 ppm NO2 and detection limit <0.5 ppm, levels relevant for industry and public health. Furthermore, the Ni-MOF-74-based sensor is selective to NO 2 over N 2 , SO 2 , and air. Linking this fundamental research with future technologies, the high impedance of MOF-74 enables applications requiring a near-zero power sensor or dosimeter, with the active material drawing <15 pW for a macroscale device 35 mm 2 with 0.8 mg MOF-74. Finally, this represents a 10 4 –10 6 × decrease in power consumption compared to other MOF sensors and demonstrates the potential for MOFs as active components for long-lived, near-zero power chemical sensors in smart industrial systems and the internet of things.

47 OTHER INSTRUMENTATION↗

Low power sensor for NO x detection

Detection and capture of toxic nitrogen oxides (NO x ) is important for emissions control of exhaust gases and general public health. The low power sensor provides direct electrically detection of trace (0.5-5 ppm) NO 2 at relatively low temperatures (50° C.) via changes in the electrical properties of nitrogen-oxide-capture active materials. For example, the high impedance of MOF-74 enables applications requiring a near-zero power sensor or dosimeter, such as for smart industrial systems and the internet of things, with 0.8 mg MOF-74 active material drawing <15 pW for a macroscale sensor 35 mm 2 area.

Small, Leo J.↗

Surface electrical properties experiment

The surface electrical properties (SEP) experiment was used to explore the subsurface material of the Apollo 17 landing site by means of electromagnetic radiation. The experiment was designed to detect electrical layering, discrete scattering bodies, and the possible presence of water. From the analysis of the data, it was expected that values of the electrical properties (dielectric constant and loss tangent) of lunar material in situ would be obtained. The basic principle of the SEP experiment is interferometry. This principle involves only the interference of two or more waves to produce an interference pattern. The inversion of the interference pattern in terms of the spatial distribution of the electrical properties is the basic aim of the experiment (fig. 15-1). The experiment is most easily understood in terms of a single dipole antenna for radiating electromagnetic energy and a loop receiver for measuring the magnitudes of the fields.

Simmons, G.↗

UHF and S-band radar observations of electrically active storm cells

The UHF-band and S-band research radars of NASA Goddard's atmospheric sciences research facility at Wallop's Island, Virginia are used to study the correlation between the location of radar-detected electrical activity in a storm cell and its precipitation reflectivity structure. The technique used to make the measurements is discussed and some typical results are presented. The existence of a bimodal distribution of lightning activity as a function of altitude is reported and supported by the data. The vertical structure of the electrical activity may be evidence of K and/or J processes. The technique used is very valuable, and provides high-resolution radar data of both reflectivities and flash density.

Gerlach, J. C.↗

Electrical readout of topological spin order in ultrathin insulators with small magnetization

Probing magnetic order in insulators with small magnetization is particularly challenging in the ultrathin limit, where magnetometry and diffraction lose sensitivity. Here, in this study, we show that topological spin order with vanishingly small magnetization can be electrically detected through an interfacial topological Hall effect in heavy-metal/magnetic-insulator heterostructures. Using Pt coupled to the canted antiferromagnetic insulator hexagonal LuFe⁢O 3 (h-LuFe⁢O 3 ) we observe an unusually large and robust Hall response arising from the transfer of real-space spin topology across the interface via magnetic proximity effect (MPE). This interfacial signal enables detection of magnetic order in h-LuFe⁢O 3 with an extremely small net magnetization (0.025 𝜇 B /Fe), corresponding to Hall-conductivity-magnetization ratio ≈ 2 V −1 , which is one to two orders of magnitude large than other MPE-induced Hall effects and anomalous Hall effects of conducting magnets. This high sensitivity allows detection of magnetic order in h-LuFe⁢O 3 down to a thickness of only 1.5 unit cells. Our results establish an interfacial Hall-based approach for electrically probing topological spin structures in ultrathin insulators and the related interfaces, enabling access to magnetic order in regimes where conventional probes fail.

Topological Hall Effect↗

Spin current generation and detection in uniaxial antiferromagnetic insulators

Spin current represents a flow of spin angular momentum and does not require movement of charges. Magnetic insulators can therefore work as a source as well as a medium of spin currents, which has been established in ferrimagnetic insulators. Here, we report recent progress in the generation and electrical detection of spin currents in uniaxial antiferromagnetic insulators carried by antiferromagnetic magnons, both thermally and resonantly excited, respectively, via the spin Seebeck effect and antiferromagnetic spin pumping by subterahertz microwaves. These findings open up many exciting possibilities of potential antiferromagnetic applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Host-Directed, Bioelectronic Immunomodulation for Protection Against Emerging Pathogens

Acute care of patients with severe infections often relies on systemic administration of pharmaceuticals and monitoring of complex physiological symptoms to identify immune system dysfunction, which can lead to increased mortality. Furthermore, determining disease-specific treatment plans often leads to a delay in patient care. To address this, we proposed an immune modulation system that electrically detects and responds to a patient’s immune system status, creating an agnostic means of treating illness and infection. Two pieces of hardware were developed for this task: a minimally-invasive sensor and a vagus nerve stimulator. Stimulation of the vagus nerve is known to modulate the immune system. The sensor is a microfabricated, silicon-based microneedle array capable of interfacing with interstitial fluid to detect small molecules such as inflammatory proteins (cytokines) and pharmaceuticals (vancomycin). Process optimization to manufacture the needles refined the silicon etch process, creating needle patches long enough to penetrate skin and reach interstitial fluid. The needles were tested for mechanical strength and stability, and did not shatter when inserted into skin models. The needles are coated with a thin film metal, turning them into electrodes for electrochemical sensing of our target molecules. We hybridized aptamers to the surface of the electrode to act as the sensing layer and were able to detect changes in the conformation of the aptamer electrochemically in the presence of the target molecule. The stimulator was a cuff electrode that encircled the vagus nerve. Rodent studies were conducted in which rodents were exposed to an inflammatory event and vagus nerve stimulation (VNS) was applied. It was demonstrated that optimized electrical stimulation of the vagus nerve created measurably different levels of cytokines in blood samples, and certain cytokines released during the inflammatory event were either upregulated or downregulated. In sum, this project successfully developed new platforms and technologies that can, with further development, enable better temporal insight into biomarker changes in the body, letting healthcare providers know of possible immune system dysfunction before they are detected physiologically. We also demonstrated the value of VNS and its possible use in treating immune system response to inflammation and illness.

59 BASIC BIOLOGICAL SCIENCES↗

Quantum Sensing of Electric Fields Using Spin-Correlated Radical Ion Pairs

Quantum sensing affords the possibility of using quantum entanglement to probe electromagnetic fields with exquisite sensitivity. In this work, we show that a photogenerated spin-correlated radical ion pair (SCRP) can be used to sense an electric field change created at one radical ion of the pair using molecular recognition. The SCRP is generated within a covalent donor–chromophore–acceptor system PXX–PMI–NDI, 1, where PXX = peri-xanthenoxanthene, PMI = 1,6-bis(p-t-butylphenoxy)perylene-3,4-dicarboximide, and NDI = naphthalene-1,8:4,5-bis(dicarboximide). The electron-rich PXX donor in 1 acts as a guest molecule that can be encapsulated selectively by a tetracationic cyclophane ExBox4+ host to give a supramolecular complex 1 ⊂ ExBox 4+ . Selective photoexcitation of the PMI chromophore results in ultrafast generation of the PXX •+ –PMI–NDI •– SCRP. When PXX is encapsulated by ExBox 4+ , the cyclophane generates an electric field that repels the positive charge on PXX •+ within PXX •+ –PMI–NDI •– , reducing the SCRP distance, i.e., the distance between the centers-of-charge on the donor and acceptor. Pulse-EPR measurements are used to measure the coherent oscillations created primarily by the electron–electron dipolar coupling in the SCRP, which yields the distance between the two charges (spins) of PXX •+ –PMI–NDI •– . Here, the experimental results show that the distance between PXX •+ and NDI •– decreases when ExBox 4+ encapsulates PXX •+ , which demonstrates that the SCRP can function as a quantum sensor to detect electric field changes in the vicinity of the radical ions.

Anions↗

Writing and Detecting Topological Charges in Exfoliated Fe 5– x GeTe 2

Fe 5–x GeTe 2 is a promising two-dimensional (2D) van der Waals (vdW) magnet for practical applications, given its magnetic properties. These include Curie temperatures above room temperature, and topological spin textures–TST (both merons and skyrmions), responsible for a pronounced anomalous Hall effect (AHE) and its topological counterpart (THE), which can be harvested for spintronics. Here, we show that both the AHE and THE can be amplified considerably by just adjusting the thickness of exfoliated Fe 5–x GeTe 2 , with THE becoming observable even in zero magnetic field due to a field-induced unbalance in topological charges. Using a complementary suite of techniques, including electronic transport, Lorentz transmission electron microscopy, and micromagnetic simulations, we reveal the emergence of substantial coercive fields upon exfoliation, which are absent in the bulk, implying thickness-dependent magnetic interactions that affect the TST. We detected a “magic” thickness t ≈ 30 nm where the formation of TST is maximized, inducing large magnitudes for the topological charge density (~6.45 × 10 20 cm –2 ), and the concomitant anomalous (ρ xy A,max ≃22.6 μΩ cm) and topological (ρ xy u,T 1≃5 μΩ cm) Hall resistivities at T ≈ 120 K. These values for ρ xy A,max and ρ xy u,T are higher than those found in magnetic topological insulators and, so far, the largest reported for 2D magnets. Furthermore, the hitherto unobserved THE under zero magnetic field could provide a platform for the writing and electrical detection of TST aiming at energy-efficient devices based on vdW ferromagnets.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Patient ECG recording control for an automatic implantable defibrillator

An implantable automatic defibrillator includes sensors which are placed on or near the patient's heart to detect electrical signals indicative of the physiology of the heart. The signals are digitally converted and stored into a FIFO region of a RAM by operation of a direct memory access (DMA) controller. The DMA controller operates transparently with respect to the microprocessor which is part of the defibrillator. The implantable defibrillator includes a telemetry communications circuit for sending data outbound from the defibrillator to an external device (either a patient controller or a physician's console or other) and a receiver for sensing at least an externally generated patient ECG recording command signal. The patient recording command signal is generated by the hand held patient controller. Upon detection of the patient ECG recording command, DMA copies the contents of the FIFO into a specific region of the RAM.

Fountain, Glen H.↗

Electronic noise of a single skyrmion

To enable the practical use of skyrmion-based devices, it is essential to achieve a balance between energy efficiency and thermal stability while also ensuring reliable electrical detection against noise. Understanding how a skyrmion interacts with material disorder and external perturbations is thus essential. Here, we investigate the electronic noise of a single skyrmion under the influence of thermal fluctuations and spin currents in a magnetic thin film. We detect the thermally induced noise with a 1/ƒ $\gamma$ signature in the strong pinning regime but a random telegraph noise in the intermediate pinning regime. Both the thermally dominated and current-induced telegraphlike signals are detected in the weak pinning regime. Our results provide a comprehensive electronic noise picture of a single skyrmion, demonstrating the potential of noise fluctuation as a valuable tool for characterizing the pinning condition of a skyrmion. In conclusion, these insights could also aid in the development of low-noise and reliable skyrmion-based devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing the Atomic Scale Mechanisms of Time Dependent Dielectric Breakdown in Si/SiO 2 MOSFETs (June 2022)

Here we report on an atomic-scale study of trap generation in the initial/intermediate stages of time-dependent dielectric breakdown (TDDB) in high-field stressed (100) Si/SiO2 MOSFETs using two powerful analytical techniques: electrically detected magnetic resonance (EDMR) and near-zero-field magnetoresistance (NZFMR). We find the dominant EDMR-sensitive traps generated throughout the majority of the TDDB process to be silicon dangling bonds at the (100) Si/SiO2 interface (Pb0 and Pb1 centers) for both the spin-dependent recombination (SDR) and trap-assisted tunneling (SDTAT) processes. We find this generation to be linked to both changes in the calculated interface state densities as well as changes in the NZFMR spectra for recombination events at the interface, indicating a redistribution of mobile magnetic nuclei which we conclude could only be due to the redistribution of hydrogen at the interface. Additionally, we observe the generation of traps known as E’ centers in EDMR measurements at lower experimental temperatures via SDR measurements at the interface. Our work strongly suggests the involvement of a rate-limiting step in the tunneling process between the silicon dangling bonds generated at the interface and the ones generated throughout the oxide.

36 MATERIALS SCIENCE↗

Colloidal structure and proton conductivity of the gel within the electrosensory organs of cartilaginous fishes

Cartilaginous fishes possess gel-filled tubular sensory organs called Ampullae of Lorenzini (AoL) that are used to detect electric fields. Although recent studies have identified various components of AoL gel, it has remained unclear how the molecules are structurally arranged and how their structure influences the function of the organs. Here we describe the structure of AoL gel by microscopy and small-angle X-ray scattering and infer that the material is colloidal in nature. To assess the relative function of the gel’s protein constituents, we compared the microscopic structure, X-ray scattering, and proton conductivity properties of the gel before and after enzymatic digestion with a protease. We discovered that while proteins were largely responsible for conferring the viscous nature of the gel, their removal did not diminish proton conductivity. The findings lay the groundwork for more detailed studies into the specific interactions of molecules inside AoL gel at the nanoscale.

59 BASIC BIOLOGICAL SCIENCES↗

Dual-Color Optical Recording of Bioelectric Potentials by Polymer Electrochromism

Optical recording based on voltage-sensitive fluorescent reporters allows for spatial flexibility of measuring from desired cells, but photobleaching and phototoxicity of the fluorescent labels often limit their sensitivity and recording duration. Voltage-dependent optical absorption, rather than fluorescence, of electrochromic materials, would overcome these limitations to achieve long-term optical recording of bioelectrical signals. Electrochromic materials such as PEDOT:PSS possess the property that an applied voltage can either increase or decrease the light absorption depending on the wavelength. In this work, we harness this anticorrelated light absorption at two different wavelengths to significantly improve the signal detection. With dual-color detection, electrical activity from cells produces signals of opposite polarity, while artifacts, mechanical motions, and technical noises are uncorrelated or positively correlated. Using this technique, we are able to optically record cardiac action potentials with a high signal-to-noise ratio, 10 kHz sampling rate, >15 min recording duration, and no time-dependent degradation of the signal. Furthermore, we can reliably perform multiple recording sessions from the same culture for over 25 days.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗