Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

High-Vacuum Triboelectric Charging of Space Materials

In the high-vacuum environment of space and the surface of the moon, static electricity on surfaces lacks the atmospheric dissipation mechanisms found on earth. As a result, the ubiquitous triboelectric charging mechanism can lead to high levels of charge on surfaces. This static charge can result in damage to sensitive devices, interfere with communications, and electrostatic levitation of lunar dust. At the NASA Electrostatics and Surface Physics Laboratory (ESPL), we use different apparatuses and techniques to tribo-charge materials in high-vacuum (10-5 torr), including a tribo-robot and a triboelectric regolith-material stage (TRMS). The tribo-robot is used to rub two materials together, and fieldmeters and electrometers can be used to determine how much charge is on the materials. The TRMS is used to drag different materials onto a bed of lunar simulant. This system is used to characterize how materials may interact with lunar dust using fieldmeters, electrometers, and laser scattering. Using these methods, we are building a database of how different space materials charge when contacting each other at high-vacuum, and how materials triboelectrically interact with the lunar surface.

Joseph Toth↗

Decoupling electrode kinetics to elucidate reaction mechanisms in alkaline water electrolysis

Alkaline water electrolysis (AWE) presents key advantages, including reduced material costs, enhanced operational stability, and compatibility with non-precious metal catalysts, positioning it as a scalable route for hydrogen production. In this study, we introduce a minimally invasive single-cell configuration incorporating a reference electrode via diaphragm extension to form an internal ion channel. This setup, combined with an interfaced potentiostat and auxiliary electrometer, enables real-time, independent monitoring of anode and cathode behavior, offering high-resolution electrochemical diagnostics. While it is well established that the hydrogen evolution reaction (HER) exhibits sluggish kinetics in alkaline media, our study reveals that this limitation persists even in practical AWE systems where nickel-based substrates are used as electrodes. This observation is supported by both experimental data and voltage breakdown modeling. Arrhenius-type analysis reveals that localized electric fields induced by catalysts shift the reaction kinetics from classical Butler–Volmer behavior toward a Marcus-like regime, where interfacial molecular dynamics and bimolecular charge transfer dominate. We propose a semi-empirical model and a surficial reaction mechanism to describe these dynamics. This work underscores the critical need for cathode innovation and provides a rational framework for designing advanced catalysts and electrode architectures to optimize AWE performance.

08 HYDROGEN↗

Towards a quantum realization of the ampere using single-electron resolution Skipper-CCDs

This paper presents a proof-of-concept demonstration of the Skipper-charge coupled device (CCD), a sensor with single-electron counting capability, as a promising technology for implementing an electron-pump-based current source. Relying on its single-electron resolution and built-in charge sensing, it allows self-calibration of the charge packets. This article presents an initial discussion of the uncertainty in the charge measurement and achievable currents levels with this technology. Here, we report experimental results that illustrate the key functionalities in manipulating both small and large electron charge packets, including a comparison of the charge generated, self-measured, and drained by the sensor against measurements from an electrometer. These results were obtained using a standard sensor and readout electronics without specific optimizations for this application. The objective is to explore the potential of Skipper-CCD for realizing an electron-based current source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Vapor-Cell-Based Atomic Electrometry for Detection Frequencies below 1 kHz

Rydberg-assisted atomic electrometry using alkali-metal atoms contained inside a vacuum environment for detecting external electric fields at frequencies below a few kilohertz has been quite challenging due to the low-frequency electric-field-screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. In this work, we report a very slow electric-field-screening phenomenon with a timescale up to the order of seconds on a rubidium-vapor cell that is made of monocrystalline sapphire. Furthermore, using this sapphire rubidium-vapor cell with an optically induced, internal bias electric field, we demonstrate vapor-cell-based, low-frequency atomic electrometry that responds to the electric field strength linearly. Limited by the given experimental conditions, this demonstrated atomic electrometer uses an active volume of 11 mm 3 and delivers a spectral noise floor of around 0.34 mV/m √Hz and a 3-dB low cutoff frequency of around 770 Hz inside the vapor cell. This work investigates a regime of vapor-cell-basedatomic electrometry that was seldom studied before, which may enable more applications that use atomicelectric-field-sensing technology.

74 ATOMIC AND MOLECULAR PHYSICS↗

Vector Electrometry in a Wide-Gap-Semiconductor Device Using a Spin-Ensemble Quantum Sensor

Nitrogen-vacancy (N-V) centers in diamond work as a quantum electrometer. Using an ensemble state of N-V centers, we propose vector electrometry and demonstrate measurements in a diamond electronic device. A transverse electric field applied to the N-V axis under a high voltage is measured, while applying a transverse magnetic field. The response of the energy-level shift against the electric field is significantly enhanced compared with that against an axial magnetic field. Repeating the measurement of the transverse electric field for multiple N-V axes, our team obtains the components of the electric field generated in the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

Direct current response of a thin scCVD diamond detector under increased applied field to 14.1 MeV neutrons

An avalanche effect yielding inherent gain can be exploited in thin, single-crystal chemical vapor deposition (scCVD) diamond. It occurs when a high enough bias is applied across the diamond thickness while avoiding breakdown. This charge multiplication effect was studied previously with alpha particles and heavy ions either by using the transient current technique or by measuring the energy spectrum. The measurements we obtained to evaluate the charge multiplication performance of a 10 μm thick scCVD diamond detector used a novel approach—we employed an electrometer to characterize the response of the detector by performing directly coupled current measurements (time-averaged charge, at 1 Hz sampling) when exposed to 14.1 MeV neutrons from deuterium-tritium fusion. We measured both the dark and irradiated currents from the detector over a range of applied displacement field values from 2 to 75 V/μm. A histogram method with central mean and standard deviation width was used to determine the current over each measurement duration typically from 100 to 300 seconds. The dark-subtracted irradiated current (i.e., contrast) was used to evaluate the gain of the detector at each applied displacement field. The contrast at an applied displacement field between 15 and 20 V/μm was higher than the expected linear increase in contrast proportional to the increased applied bias, indicating the possible presence of avalanche events in the diamond. The detector response also indicated possible polarization and charge depletion effects. These results provide an opportunity to further explore the use of thin scCVD diamond as a fast neutron current mode detector with inherent gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Scanning Diamond Detector for Electron Beam Profile Monitoring

The first prototype of a fast scanning diamond beam profile detector (DBPD) suitable for invasive high power CW electron beam core profile measurements in transmittance mode was developed. It consists of a multi-strip solid state diamond detector to scan with high speed (up to 1 m/s) and precision (about 5 μm) through the core of an electron beam. The diamond sensor was made from a thin polycrystalline diamond (PCD) plate with highly B-doped diamond conductive strips both grown by CVD. Transient currents from the multi-strip detector were measured with fast digitizing electrometers. Successful operation of the DBPD was demonstrated for pulsed (5 Hz) and CW (78 kHz) CeC beams, including the detector’s ability to withstand a 20 sec insertion into the CW CeC beam core. The X-Y beam spatial profile was measured in one scan. Thermal modelling demonstrated a manageable thermal impact even from a relatively long insertion of the diamond sensor into the CW CeC core and very short (0.2 s) insertion into the CW LEReC beam core. Electrical impedance modelling of the detector and vacuum chamber assembly demonstrated minimal impact on beam line impedance with diamond sensor insertion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗