Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron Beam Collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Observation of optical transition radiation from electron beams generated by laser plasma accelerator

Laser plasma accelerators (LPAs) have made great progress, achieving electron beam with energy up to 1 GeV from a centimeter scale capillary plasma waveguide. Here in this work, we report the measurement of optical transition radiation (OTR) from the capillary-based LPA electron beams. Transition radiation images, produced by electrons passing through two separate foils (located at 2.3 m and 3.8 m away from the exit of the LPA) were recorded with a high resolution imaging system, respectively. Two magnetic quadrupole lenses were placed right after the capillary to focus and collimate the electron beams. Lastly, significant localized spikes appeared in the OTR images when the electron beam was focused by the magnetic quadrupole lenses, indicating the coherence of the radiation and the existence of ultrashort longitudinal structures inside the electron beam.

43 PARTICLE ACCELERATORS↗

Computational Study of 15 MeV Linac Radiation Doses at the UNLV Accelerator Facility

Linear electron accelerators (linacs) are used to generate Bremsstrahlung photons through the interaction of an electron beam with a heavy metal target. These Bremsstrahlung photons with endpoint energy equal to that of the impinging electron beam are typically collimated into a desired beam shape (fan or cone beams). At electron energies larger than 10 MeV, the interaction of the newly produced photons with the linac component materials leads to the production of neutrons. These neutrons are often undesired and pollute the collimated photon beam while increasing the dose rates at the facility due to the linac operation. MCNPX 2.7.0 code was used to investigate the production of neutrons due to the normal operation of a 15 MeV linac. Dose rates within the UNLV accelerator facility were calculated for both photons and neutrons. Furthermore, the irradiation of several materials using the K15 linac was modeled; the resulting neutron fluxes and dose rates were determined. (authors)

43 PARTICLE ACCELERATORS↗

MD 2167: Effect of a resonant excitation on the evolution of the beam emittance and halo population

Collimation with hollow electron beams or lenses (HEL) is currently one of the most promising concepts for active halo control in HL-LHC. In previous studies it has been shown that the halo can be efficiently removed with a hollow electron lens. Equally important as an efficient removal of the halo, is to demonstrate that the core stays unperturbed. In the case of an ideal hollow electron lens without bends, the field at the location of the beam core vanishes and the core thus remains unperturbed. In reality, the field at the beam core does not vanish entirely due to imperfections in the electron beam profile and the electron lens bends necessary to guide the electron in and out of the proton aperture. In particular, in the case of a pulsed operation of the electron lens the non-vanishing residual field induces noise on the proton beam. To identify the most sensitive pulsing patterns for the resonant mode and derive tolerances on the profile imperfections, a first MD (MD1415) was carried out on 24.08.2016 [1] and a second MD on 17.09.2017. In this note we present the results of the second MD (MD2167), which focused on confirming a part of the results of the first MD and testing in addition a resonant excitation for which no effect on the beam core is expected and the effect of random uniform noise in addition.

43 PARTICLE ACCELERATORS↗

Implementation of Hollow Electron Lenses in SixTrack and First Simulation Results for the HL-LHC

Electron lenses have found a wide range of applications for hadron colliders, where the main applications are machine protection and beam-beam compensation. This paper summarizes the status of the current electron lens implementation in SixTrack with the focus on hollow electron beams for beam collimation and shows some first simulation results of the High-Luminosity upgrade of the LHC (HL-LHC).

43 PARTICLE ACCELERATORS↗

Electronic properties in a quantum well structure of Weyl semimetal

We investigate the confined states and transport of three-dimensional Weyl electrons around a one-dimensional external rectangular electrostatic potential. The confined states with finite transverse wave vector exist at energies higher than the half well depth or lower than the half barrier height. The rectangular potential appears completely transparent to the normal incident electrons but not otherwise. The tunneling transmission coefficient is sensitive to their incident angle and shows resonant peaks when their energy coincides with the confined spectra. In addition, for the electrons in the conduction (valence) band through a potential barrier (well), the transmission spectrum has a gap of width increasing with the incident angle. Interestingly, the electron linear zero-temperature conductance over the potential can approach zero when the Fermi energy is aligned to the top and bottom energies of the potential, when only electron beams normal to the potential interfaces can pass through. The considered structure can be used to collimate the Weyl electron beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stabilization of beam-weibel instability by equilibrium density ripples

In this paper, we present an approach to achieve suppression/complete stabilization of the transverse electromagnetic beam Weibel instability in counter streaming electron beams by modifying the background plasma with an equilibrium density ripple, shorter than the skin depth; this weakening is more pronounced when thermal effects are included. On the basis of a linear two stream fluid model, it is shown that the growth rate of transverse electromagnetic instabilities can be reduced to zero value provided certain threshold values for ripple parameters are exceeded. We point out the relevance of the work to recent experimental investigations on sustained (long length) collimation of fast electron beams and integral beam transport for laser induced fast ignition schemes, where beam divergence is suppressed with the assistance of carbon nano-tubes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within {+-}1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Summary of Results for Idaho Accelerator Center (IAC) Experiments with Compact Electron Permanent Magnet Spectrometer (CEPMS)

The Compact Electron Permanent Magnet Spectrometer (CEPMS) shown in Figure 2 consists of collimation at the electron beam entrance, a vacuum chamber for beam transport and a removable 60 degree sector magnet constructed by SABR Enterprises (Ref 2) that is used to momentum analyze the incoming electron beam. There are electron detection planes located perpendicular to straight through and the 60 degree trajectory ports. The planes are designed to accept phosphor screens for time integrated measurements. The screens can be replaced by scintillator for time resolved measurements using gated or streak cameras. The length of the spectrometer along the beamline without the collimator is about 400mm (14”). The spectrometer requires no power supply with controls for cycling or cooling for the magnet. The entire assembly, with magnet installed, weighs about 35kg (75lbs) Figure 3 depicts central and extreme trajectories through the spectrometer for various electron energies. The chamber accommodates a +/-50mm wide detection field relative to the center trajectory. Trajectories with larger momentum (energy) are bent the least. Since the permanent magnet slides off and on with reference to the upstream edge of the vacuum chamber, it can be adjusted to various positions to slightly increase or decrease the central energy thereby changing the range of available energies. Figure 4 shows the effect of changing the location of the permanent magnet on the electron trajectory. A small inward change in r produces a longer trajectory in the magnet therefore, the same energy trajectory is bent more.

43 PARTICLE ACCELERATORS↗

Sci—Thur PM: Planning and Delivery — 03: Automated delivery and quality assurance of a modulated electron radiation therapy plan

Modulated electron radiation therapy (MERT) offers the potential to improve healthy tissue sparing through increased dose conformity. Challenges remain, however, in accurate beamlet dose calculation, plan optimization, collimation method and delivery accuracy. In this work, we investigate the accuracy and efficiency of an end-to-end MERT plan and automated-delivery workflow for the electron boost portion of a previously treated whole breast irradiation case. Dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. The automated delivery, which covered 4 electron energies, 196 subfields and 6183 total MU was completed in 25.8 minutes, including 6.2 minutes of beam-on time with the remainder of the delivery time spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. The delivery time could be reduced by 5.3 minutes with minor electron collimator modifications and the beam-on time could be reduced by and estimated factor of 2–3 through redesign of the scattering foils. Comparison of the planned and delivered film dose gave 3%/3 mm gamma pass rates of 62.1, 99.8, 97.8, 98.3, and 98.7 percent for the 9, 12, 16, 20 MeV, and combined energy deliveries respectively. Good results were also seen in the delivery verification performed with a MapCHECK 2 device. The results showed that accurate and efficient MERT delivery is possible with current technologies.

60 APPLIED LIFE SCIENCES↗

The 3H-3He Charge Radii Difference

The upcoming E12-14-009 [1] experiment at Jefferson Lab will determine the ratio of the electric form factors for the A=3 mirror nuclei 3He and 3H. The measurement will use a 1.1 GeV electron beam, a special collimator plate to allow for simultaneous optics measurements, and the low-activity tritium target being prepared for Jefferson Lab. By observing the dependence of the form factor ratio as a function of Q2 over 0.05–0.09 GeV2, the dependence of the radii extraction on the shape of the form factors is minimized. As a result, we anticipate the uncertainty of the extracted charge radii difference to be 0.03 fm, a reduction of 70% from the current measurement. Using precise measurements of the 3He charge radius from isotopic shift or μHe measurements [2–4], we can deduce the absolute 3H charge radius. The results will provide a direct comparison to recent calculations of the charge radii.

Myers, Luke S.↗

Magnetic field generation during intense laser channelling in underdense plasma

Channel formation during the propagation of a high-energy (120 J) and long duration (30 ps) laser pulse through an underdense deuterium plasma has been spatially and temporally resolved via means of a proton imaging technique, with intrinsic resolutions of a few μm and a few ps, respectively. Conclusive proof is provided that strong azimuthally symmetric magnetic fields with a strength of around 0.5 MG are created inside the channel, consistent with the generation of a collimated beam of relativistic electrons. The inferred electron beam characteristics may have implications for the cone-free fast-ignition scheme of inertial confinement fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Broadband coherent XUV light from e − / e + microbunching in an intense laser pulse

Attosecond pulses of coherent extreme ultraviolet (XUV) light are instrumental for investigating subatomic dynamics and can be produced using a free-electron laser (FEL). It has been suggested that an optical FEL, which employs a laser pulse in place of a conventional undulator, could enable a dramatically more compact implementation of such a light source. Yet, the high electron density and subsequent high emittance implied by an optical FEL makes this concept challenging to realize with an electron beam. There has been impressive progress in recent years producing collimated dense and relativistic beams of electrons and positrons in the laboratory. As we demonstrate here, the inherent stability of a quasi-neutral electron-positron beam mitigates Coulomb expansion, and renders it a promising alternative source of coherent light. Specifically, we show via computer simulations that broadband coherent light in the XUV domain, which takes the form of 8-as pulses at 92-as intervals, can be generated by microbunching of relativistic electrons and positrons in a laser pulse. This process occurs over a sub-millimeter length scale, enabling the development of light sources which are orders-of-magnitude more compact than existing sources, with potential applications in physics, chemistry, biology, and industry.

47 OTHER INSTRUMENTATION↗

Radiation Safety Consideration for the Parasitic Final Focus Test Beam at SLAC

A low intensity electron beam parasitic to the operation of the Stanford Linear Collider (SLC) has been transported through the Final Focus Test Beam (FFTB) facility making secondary test beams available for users. Photons generated in collimation of the SLC electron and positron beams in the linac pass through a splitter magnet that deflects the primary beams away from the linac axis into the SLC beam lines. These photons are converted to electrons and positrons in a secondary production target located down beam on the hnac axis. The secondary electrons are then transported through the FFTB beam line onto experimental detectors. The average power of the parasitic beam is very low, thus, it presents no hazards. However, various accident scenarios involving failure of the splitter magnet and the active protection devices could send much more powerful SLC beams (up to 90 kilo-watts) into this zero-degree secondary beam line. For the accident case, the average power in the transmitted beam was calculated using the Monte Carlo programs EGS4 and TURTLE. Results from analysis of the radiation protection systems that assure safety during the parasitic operation are presented.

Rokni, S. H.↗

High-resolution planar electron beam induced current in bulk diodes using high-energy electrons

Understanding the impact of high-energy electron radiation on device characteristics remains critical for the expanding use of semiconductor electronics in space-borne applications and other radiation harsh environments. Here in this paper, we report on in situ measurements of high-energy electron radiation effects on the hole diffusion length in low threading dislocation density homoepitaxial bulk n-GaN Schottky diodes using electron beam induced current (EBIC) in high-voltage scanning electron microscopy mode. Despite the large interaction volume in this system, quantitative EBIC imaging is possible due to the sustained collimation of the incident electron beam. This approach enables direct measurement of electron radiation effects without having to thin the specimen. Using a combination of experimental EBIC measurements and Monte Carlo simulations of electron trajectories, we determine a hole diffusion length of 264 ± 11 nm for n-GaN. Irradiation with 200 kV electron beam with an accumulated dose of 24 × 10 16 electrons cm -2 led to an approximate 35% decrease in the minority carrier diffusion length.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-344: Dynamic Electron Beam Therapy Using Multiple Apertures in a Single Cut-Out

Purpose: Few leaf electron collimators (FLEC) or electron MLCs (eMLC) are highly desirable for dynamic electron beam therapies as they produce multiple apertures within a single delivery to achieve conformal dose distributions. However, their clinical implementation has been challenging. Alternatively, multiple small apertures in a single cut-out with variable jaw sizes could be utilized in a single dynamic delivery. In this study, we investigate dosimetric characteristics of such arrangement. Methods: Monte Carlo (EGSnrc/BEAMnrc/DOSXYnrc) simulations utilized validated Varian TrueBeam phase spaces. Investigated quantities included: Energy (6 MeV), jaw size (1×1 to 22×22 cm {sup 2}; centered to aperture), applicator/cut-out (15×15 cm{sup 2}), aperture (1×1, 2×2, 3×3, 4×4 cm{sup 2}), and aperture placement (on/off central axis). Three configurations were assessed: (1) single aperture on-axis, (2) single aperture off-axis, and (3) multiple apertures. Reference was configuration (1) with standard jaw size. Aperture placement and jaw size were optimized to maintain reference dosimetry and minimize leakage through unused apertures to <5%. Comparison metrics included depth dose and orthogonal profiles. Results: Configuration (1) and (2): Jaw openings were reduced to 10×10 cm{sup 2} without affecting dosimetry (gamma 2%/1mm) regardless of on- or off-axis placement. For smaller jaw sizes, reduced surface (<2%, 5% for 1×1 cm{sup 2} aperture) and increased Bremsstrahlung (<2%, 10% for 1×1 cm{sup 2} aperture) dose was observed. Configuration (3): Optimal aperture placement was in the corners (order: 1×1, 4×4, 2×2, 3×3 cm{sup 2}) and jaw sizes were 4×4, 4×4, 7×7, and 5×5 cm{sup 2} (apertures: 1×1, 2×2, 3×3, 4×4 cm{sup 2} ). Asymmetric leakage was found from upper and lower jaws. Leakage was generally within 5% with a maximum of 10% observed for the 1×1 cm{sup 2} aperture irradiation. Conclusion: Multiple apertures in a single cut-out with variable jaw size can be used in a single dynamic delivery, providing a practical alternative to FLEC or eMLC. Future simulations will expand on all variables.

60 APPLIED LIFE SCIENCES↗