Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Efficient Windows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

User Friendly Web-Based Tool to Assess the Energy Efficiency and Durability of Residential Wall Retrofits

According to the U.S. Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies, building envelope wall energy loss in the United States accounts for about 5.9 x 1010 kWh or 2 quads of energy annually, costing homeowners and occupants billions of dollars. Enclosure retrofits targeting these losses can save significant energy, reduce greenhouse gas emissions, and save occupants millions of dollars over time. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established, represent approximately 68 percent of the residential building stock in the country, often having significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation have heating and cooling losses that can represent a substantial portion of utility bills.High-performance building envelope retrofit systems are rarely selected for retrofit applications. Current solutions are expensive and/or unfamiliar to many designers, builders, contractors, and code officials and therefore are perceived as risky. The dominant perceived risk is durability specifically related to condensation and moisture accumulation in the building envelope component.The Building Science Advisor (BSA) is a rule-based expert system web-based tool that was originally developed to assist building professionals in designing energy efficient and durable wall systems for new construction. With the present focus being placed on upgrading the existing building stock, a retrofit module has been developed that, based on the location, existing construction, and planned retrofit strategy, provides recommendations on how to address the retrofit in a manner that will perform in accordance with IECC 2018 building code and not create a durability problem. This paper will describe the development of this tool and demonstrate its features and capabilities.

Desjarlais, Andre Omer↗

Introduction of localized spin-state transitions in the optical absorption spectrum of Cr-doped GaN

Using a hybrid density functional, we study the electronic, magnetic, and neutral excitations of the paradigmatic Cr-doped GaN solid. Our results indicate that the ≈1% doped wurtzite GaN crystal retains the semiconducting nature of the host, associated with a magnetic moment of 3 μ B . Further, as a consequence of Cr doping, additional hybridized bands are formed within the intrinsic band gap of GaN, leading to a considerable band gap narrowing by 1.4 eV and low-energy optical transitions. Our results indicate dark Cr d-d transitions at very low energy (0.5–0.7 eV), followed by bright transitions in the visible energy range (1.8–2.2 eV). Characterization of the electron-hole pairs suggests that the latter originates from the internal transitions among hybridized Cr d –N p states. With the existence of these additional optical features within the visible energy window, one can expect an enhancement to the photoelectric conversion efficiency of GaN upon Cr doping, in addition to applications in spintronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluating the energy impact potential of energy efficiency measures for retrofit applications: A case study with U.S. medium office buildings

Quantifying the energy savings of various energy efficiency measures (EEMs) for an energy retrofit project often necessitates an energy audit and detailed whole building energy modeling to evaluate the EEMs; however, this is often cost-prohibitive for small and medium buildings. In order to provide a defined guideline for projects with assumed common baseline characteristics, this paper applies a sensitivity analysis method to evaluate the impact of individual EEMs and groups these into packages to produce deep energy savings for a sample prototype medium office building across 15 climate zones in the United States. We start with one baseline model for each climate zone and nine candidate EEMs with a range of efficiency levels for each EEM. Three energy performance indicators (EPIs) are defined, which are annual electricity use intensity, annual natural gas use intensity, and annual energy cost. Then, a Standard Regression Coefficient (SRC) sensitivity analysis method is applied to determine the sensitivity of each EEM with respect to the three EPIs, and the relative sensitivity of all EEMs are calculated to evaluate their energy impacts. For the selected range of efficiency levels, the results indicate that the EEMs with higher energy impacts (i.e., higher sensitivity) in most climate zones are high-performance windows, reduced interior lighting power, and reduced interior plug and process loads. However, the sensitivity of the EEMs also vary by climate zone and EPI; for example, improved opaque envelope insulation and efficiency of cooling and heating systems are found to have a high energy impact in cold and hot climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust Large-Scale Dynamic Windows using Reversible Metal Electrodeposition

This project funded the study and development of dynamic windows based on reversible metal electrodeposition (RME). Dynamic windows allow user control over light and heat flow into and out of buildings, which offer both advantages in building aesthetics (with worker productivity improvement of 2%) and energy efficiency (up to 20% savings) compared to static controls such as low emissivity coatings and blinds/shades. Despite these advantages, dynamic windows, which traditionally rely on electrochromic metal oxides or conductive organic molecules for light modulation have failed to significantly impact the market due to issues related to cost, color, and optical dynamic range. Dynamic windows based on reversible metal electrodeposition (RME) are an exciting alternative approach and have the potential to overcome the issues associated with traditional technologies. A RME dynamic window is an electrochemical cell that modulates light using the reversible electrodeposition of metal on and off a transparent conducting oxide (TCO), which serves as the working electrode. The electrolyte has nearly colorless metal salts dissolved, and application of a cathodic potential on the TCO reduces the metal cations across the TCO surface to their metallic form, making a thin film that is efficient at blocking out light. A reverse in polarity oxidizes the metal, where it dissolves into solution, returning the window back to transparent. The counter electrode typically employed is a metal mesh, which is used to balance the electrochemical reactions happening on the TCO working electrode. These RME dynamic windows have the largest dynamic range (capable of reaching <<0.1% transmission) with color neutral tinting of any existing technology using solution processed techniques, which positions the technology as a promising candidate to penetrate the residential market. We have successfully scaled up the windows from 25 cm2 to 929 cm 2 , and we have demonstrated significant improvements to both the cycle life (10,000 cycles in a 3-electrode half-cell) and shelf life (>1 month) of our windows. We have published our work in high impact journals (6 published and 2 manuscripts in prep), filed 5 patents, and have incorporated TYNT Technologies to commercialize the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovations in Sensors and Controls for Building Energy Management: Research and Development Opportunities Report for Emerging Technologies

Sensors, actuators, and controllers, which collectively serve as the backbone of cyberphysical systems for building energy management, are one of the core technical areas of investment for achieving the U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) goals for energy affordability in the national building stock - both commercial and residential. In fact, an aggregated annual energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms. energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of InAlAs window layer on the efficiency of indium phosphide solar cells

Indium phosphide (InP) solar cell efficiencies are limited by surface recombination. The effect of a wide-bandgap lattice-matched indium aluminum arsenide (In0.52Al0.48As) window layer on the performance of InP solar cells was investigated using a numerical code PC-1D. The p(+)n InP solar cell performance improves significantly with the use of a window layer. No improvement is seen for n(+)p InP cells. Cell results are explained by the band diagram of the heterostructure and the conduction-band energy discontinuity. The calculated I-V and internal quantum efficiency results clearly demonstrate that In0.52Al0.48As is a promising candidate as a window layer material for p(+)n InP solar cells.

Jain, R. K.↗

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Exterior Shades at PNNL Lab Homes and Occupied Field Sites (Final Report)

In residential applications, heat transfer through windows accounts for a significant portion of a home’s cooling load. Exterior shades are window attachments that can be applied on the exterior-side of windows in a home. Exterior shades can reduce solar heat gain, reduce glare through a window, and improve comfort in the home. To assess the performance of residential exterior shades, the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (BTO) commissioned a series of field studies for exterior fabric shades to be performed by Pacific Northwest National Laboratory (PNNL) during the cooling seasons of 2019 and 2020. This report describes the experimental setup and results of these exterior shade field studies. PNNL, in collaboration with Lawrence Berkeley National Laboratory (LBNL), evaluated exterior shades at the PNNL Lab Homes and three occupied field sites in Richland, Washington. At the Lab Homes, the energy performance of exterior shades was evaluated in a controlled side-by-side environment. At the occupied field sites, exterior shades were characterized by measuring shade usage, documenting installation practices, and surveying customer perspectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of InAlAs window layer on efficiency of indium phosphide solar cells

Indium phosphide (InP) solar cell efficiencies are limited by surface recombination. The effect of a wide bandgap, lattice-matched indium aluminum arsenide (In(0.52)Al(0.48)As) window layer on the performance of InP solar cells was investigated by using the numerical code PC-1D. The p(+)n InP solar cell performance improved significantly with the use of the window layer. No improvement was seen for the n(+)p InP cells. The cell results were explained by the band diagram of the heterostructure and the conduction band energy discontinuity. The calculated current voltage and internal quantum efficiency results clearly demonstrated that In(0.52)Al(0.48)As is a very promising candidate for a window layer material for p(+)n InP solar cells.

Jain, Raj K.↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear Astrophysics in the Storage Ring: Background Suppressed Simultaneous Measurement of (p,γ) and (p,n) Reactions

We report the application of the new elimination of Rutherford elastic scattering technique for the measurement of proton-induced reaction cross sections utilizing stored ions decelerated to astrophysical energies. This approach results in a background reduction factor of about 1 order of magnitude, enabling the first measurement of a (p, n) cross section in a storage ring. Here, the reaction channels 124 Xe⁢(p,n) and 124 Xe⁢(p,γ) have been studied just above the neutron threshold energy. The new data provide valuable constraints for Hauser-Feshbach theory and extrapolation of the (p,γ) cross section to lower energies. Most importantly, for nuclei of limited availability, the method represents a powerful improvement to efficiently study proton-induced reactions at energies within or close to the astrophysical Gamow window, bringing many reaction measurements within reach that were previously inaccessible in the laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Challenges and Opportunities for Basic Efficiency Measures in Low-Income Homes: A Southeast Alaska Case Study

Juneau, Alaska is the state's capital city and has a renewable energy goal to reach 80% renewable energy for the space heating and transportation sectors by 2045. In practical terms, this indicates a need to electrify both sectors, to take advantage of the inexpensive hydropower available from the local electric utility, Alaska Energy Light & Power. In an effort to complement and enable electrification, researchers examined the feasibility to deploy storm windows via a case study of installing storm windows in two local low-income homes. Newer models of storm windows provide an extra layer of insulation over existing windows, while preserving operability and views. They can also improve comfort and reduce noise. Researchers worked with the regional housing authority and a local builder to install the storm windows and replace inoperable windows in the two houses in 2021, in addition to conducting pre- and post-installation air leakage tests, energy monitoring, and occupant interviews. The team encountered several challenges, including a lack of egress windows, energy data from a wide variety of heating systems, extremely leaky homes, and installation issues such as windows that were not square. These results point to several barriers to widespread deployment of storm windows in the area, but also open the door to opportunities to design deployment programs that improve safety as well as efficiency.

cold climate↗

High‐Energy‐Density Chelated Chromium Flow Battery Electrolyte at Neutral pH

Abstract High‐concentration operation of redox flow batteries (RFBs) is essential for increasing their energy‐storage capacity, but non‐acidic electrolytes struggle to achieve the high concentrations of metal ions dissolved in acid, limiting the development of energy‐dense neutral pH electrolytes. We report neutral pH RFB operation of chromium 1,3‐propylenediaminetetraacetate (CrPDTA) at concentrations of 1.2 M at room temperature and 1.6 M at 40 °C, demonstrating 60% higher negolyte capacity, up to 42.9 Ah L −1 , than previously reported for non‐additive‐utilizing solutions of this promising material. With extended full cell cycling, we demonstrate the importance of buffer selection and pH when using the Fumasep E‐620(K) membrane. Finally, we expand the pH operation range of CrPDTA to pH 7, which when cycled at 100 mA cm −2 against a ferrocyanide posolyte demonstrated excellent coulombic efficiencies >99.7% and energy efficiencies >87%, while operating at almost 700 mV more negative than the thermodynamic hydrogen evolution window.

Chemistry↗

Low-Voltage Haze Tuning with Cellulose-Network Liquid Crystal Gels

Being key components of the building envelope, glazing products with tunable optical properties are in great demand because of their potential for boosting energy efficiency and privacy features while enabling the main function of allowing natural light indoors. However, windows and skylights with electric switching of haze and transparency are rare and often require high voltages or electric currents, as well as not fully meet the stringent technical requirements for glazing applications. Here, by introducing a predesigned gel material we describe an approach dubbed “Haze-Switch” that involves low-voltage tuning of the haze coefficient in a broad range of 2–90% while maintaining high visible-range optical transmittance. The approach is based on a nanocellulose fiber gel network infiltrated by a nematic liquid crystal, which can be switched between polydomain and monodomain spatial patterns of optical axis via a dielectric coupling between the nematic domains and the applied external electric field. By utilizing a nanocellulose network of nanofibers ~10 nm in diameter we achieve <10 V dielectric switching and <2% haze in the clear state, as needed for applications in window products. Finally, we characterize physical properties relevant to window and smart glass technologies, like the color rendering index, haze coefficient, and switching times, demonstrating that our material and envisaged products can meet the stringent requirements of the glass industry, including applications such as privacy windows, skylights, sunroofs, and daylighting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transparent window film with embedded nano-shades for thermoregulation

Every year, more than 20% of the energy consumption in the United States and more than 10% of the global consumption is used towards HVAC (Heating, Ventilating, Air-Conditioning) systems in buildings. Although continued efforts in advancing renewable energy, efficient appliances, and smart building systems are desired, the most critical factors that cause extensive indoor energy consumption are thermal leakage and thermal waste generation. We demonstrate a smart window film that allows natural lighting with a clear view while blocking oblique incident sunlight to make the building interior cooler without using electricity or generating heat. Building upon the concept of, often overlooked, traditional window shades and privacy window films, we emphasize and elevate the application and impact of using magnetically arranged nanoscale material for energy conservation purpose in buildings. By embedding vertically aligned Ni flakes (VANF) in a polymer matrix film, nanoscale mirror array serve as shades to block the high-angled incident sunlight, blocking approximately 73% of total solar irradiance and bringing down the indoor temperature by 1.92 °C during the daytime in a model house while providing nearly 90% transparency. Global application was simulated by applying the respective solar angle and intensity at selected latitudes, indicating their potential. This passively energy-conserving smart film is a low cost, maintenance free, and simple product for users and easy-to-manufacture product for the industry.

36 MATERIALS SCIENCE↗