Search NASA⌕ Search

SEARCH · Search NASA

Results for “Environmental chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Novel Solar Panel Defect Detection Hardware and Defect Analysis Software (CRADA Final Report)

The CRADA work involved 1) the development of a machine learning software architecture to automatically detect defects within Electroluminescence images of solar panels, and 2) demonstrations of the usefulness of UV Fluorescence (UVF) defect detection for a wide variety of defect types across many different solar panel technologies with different field or environmental chamber histories.

14 SOLAR ENERGY↗

Novel Solar Panel Defect Detection Hardware and Defect Analysis Software (CRADA Final Report)

The CRADA work involved 1) the development of a machine learning software architecture to automatically detect defects within Electroluminescence images of solar panels, and 2) demonstrations of the usefulness of UV Fluorescence (UVF) defect detection for a wide variety of defect types across many different solar panel technologies with different field or environmental chamber histories.

14 SOLAR ENERGY↗

Not all types of secondary organic aerosol mix: two phases observed when mixing different secondary organic aerosol types

Abstract. Secondary organic aerosol (SOA) constitutes a large fraction of atmospheric aerosol. To assess its impacts on climate and air pollution, knowledge of the number of phases in internal mixtures of different SOA types is required. Atmospheric models often assume that different SOA types form a single phase when mixed. Here, we present visual observations of the number of phases formed after mixing different anthropogenic and biogenic SOA types. Mixing SOA types generated in environmental chambers with oxygen-to-carbon (O/C) ratios between 0.34 and 1.05, we found 6 out of 15 mixtures of two SOA types to result in two phase particles. We demonstrate that the number of phases depends on the difference in the average O/C ratio between the two SOA types (Δ(O/C)). Using a threshold Δ(O/C) of 0.47, we can predict the phase behavior of over 90 % of our mixtures, with one- and two-phase particles predicted for Δ(O/C)<0.47 and Δ(O/C)≥0.47, respectively. This threshold ΔO/C value provides a simple parameter to predict whether mixtures of fresh and aged SOA form one- or two-phase particles in the atmosphere. In addition, we show that phase-separated SOA particles form when mixtures of volatile organic compounds emitted from real trees are oxidized.

Mahrt, Fabian (ORCID:0000000270596765)↗

Impact of UV-light and pH on the Fate of Tc, I, and U in Wetlands at Savannah River Site - 20230

The Savannah River Site (SRS) is one of the major nuclear facilities owned by the U.S Department of Energy. During the Cold War, these facilities produced large amounts of radioactive and hazardous waste. On site, three unlined seepage basins in the F-Area received approximately 1.8 billion gallons of low-level waste containing nitric acid, radionuclides, and dissolved metals due to plutonium and tritium production operations. The acidic nature of the waste created a source of relatively mobile radionuclides below the basins. Radionuclides previously disposed of within the F-Area, including uranium isotopes (U), technetium-99 (Tc-99), and iodine-129 (I-129), are moving with groundwater towards Four Mile Branch Wetland, where they are subsequently upwelling and interacting with natural organic matter (NOM). Many environmental factors including redox conditions, porewater composition, pH, light, and temperature affect the degradation of organic matter as well as interactions with Tc-99, U, and I-129. In particular, the high concentrations of nitrate from the acidic waste may increase the formation of reactive oxygen species (ROS) that impact both degradation of NOM and behavior of contaminants. In the presence of sunlight, I-129, Tc-99, and U speciation and complexation behavior may be affected by ROS and NOM degradation products in addition to the factors generally considered in subsurface systems in the absence of light. This research aims to determine whether the interactions between radionuclides, NOM, and nitrate affect the fate of I-129, Tc-99, and U and which processes are controlling their behavior. Experiments were conducted at variable pH in the presence of NaNO{sub 3} in order to determine the impact of light and pH on NOM degradation and to evaluate the impact on the fate of contaminants of concern. Soil samples high in NOM collected from two sites in the Southeastern United States (Savannah River Site and the Everglades) were studied. Batch experiments were conducted with NOM and the following aqueous contaminants, U, I-129, Tc-99 with exposure to ultraviolet (UV) light in an environmental chamber. This study was conducted in a sterile environment in order to exclude the potential for microbial degradation of organic matter. Results indicated photodegradation of NOM and significant interaction of radionuclides with NOM. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)↗

Evaluation of the Thermal and Moisture Performance of Insulating Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak heating and cooling loads of a home. Over the past 20 years, residential window attachment retrofit technologies have been developed that significantly increase the number of options available to home builders, homeowners, and utilities when considering upgrades of overall window performance. Within the interior window attachments category, honeycomb cellular shades typically have the highest R-values because of their layered or concentric designs. During the winter when the window is fully covered, however, the added insulation reduces the amount of warm indoor air that reaches the window surface, thereby lowering the temperature of the window glass and frame and increasing the potential for condensation to collect on the interior surface of the window. The degree to which this potential is realized depends on the indoor and outdoor conditions as well as the overall thermal resistance of the window and the shades. To examine the condensation buildup potential on the interior surface of the window and the conditions under which this occurs, this report describes experimental research conducted by Pacific Northwest National Laboratory in collaboration with Hunter Douglas, using a a controlled environmental test chamber at the Hunter Douglas facility in Broomfield, Colorado. The results will be used to inform the Attachments Energy Rating Council, which provides energy performance information on all rated window attachments products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mycorrhizal associations of temperate forest seedlings mediate rhizodeposition, but not soil carbon storage, under elevated nitrogen availability

Abstract Tree‐mycorrhizal associations are associated with patterns in nitrogen (N) availability and soil organic matter storage; however, we still lack a mechanistic understanding of what tree and fungal traits drive these patterns and how they will respond to global changes in soil N availability. To address this knowledge gap, we investigated how arbuscular mycorrhizal (AM)‐ and ectomycorrhizal (EcM)‐associated seedlings alter rhizodeposition in response to increased seedling inorganic N acquisition. We grew four species each of EcM and AM seedlings from forests of the eastern United States in a continuously 13 C‐labeled atmosphere within an environmentally controlled chamber and subjected to three levels of 15 N‐labeled fertilizer. We traced seedling 15 N uptake from, and 13 C‐labeled inputs (net rhizodeposition) into, root‐excluded or ‐included soil over a 5‐month growing season. N uptake by seedlings was positively related to rhizodeposition for EcM‐ but not AM‐associated seedlings in root‐included soils. Despite this contrast in rhizodeposition, there was no difference in soil C storage between mycorrhizal types over the course of the experiment. Instead root‐inclusive soils lost C, while root‐exclusive soils gained C. Our findings suggest that mycorrhizal associations mediate tree belowground C investment in response to inorganic N availability, but these differences do not affect C storage. Continued soil warming and N deposition under global change will increase soil inorganic N availability and our seedling results indicate this could lead to greater belowground C investment by EcM‐associated trees. This potential for less efficient N uptake by EcM‐trees could contribute to AM‐tree success and a shift toward more AM‐dominated temperate forests.

Fitch, Amelia A.↗

Modeling the Size Distribution and Chemical Composition of Secondary Organic Aerosols during the Reactive Uptake of Isoprene-Derived Epoxydiols under Low-Humidity Condition

Reactive uptake of isoprene epoxydiols (IEPOX), which are isoprene oxidation products, onto acidic sulfate aerosols is recognized to be an important mechanism for the formation of isoprene-derived secondary organic aerosol (SOA). While a mechanistic understanding of IEPOX-SOA formation exists, several processes affecting their formation remain uncertain. Evaluating mechanistic IEPOX-SOA models with controlled laboratory experiments under longer atmospherically relevant timescales is critical. Here, we implement our latest understanding of IEPOX-SOA formation within a box model to simulate the measured reactive uptake of IEPOX on polydisperse ammonium bisulfate seed aerosols within an environmental Teflon chamber. The model is evaluated with single-particle measurements of size distribution, volume, density, and composition of aerosols due to IEPOX-SOA formation at timescales of hours. Additionally, we find that the model can simulate the growth of particles due to IEPOX multiphase chemistry, as reflected in increases of the mean particle size and volume concentrations, and a shift of number size distribution to larger sizes. The model also predicts the observed evolution of particle number mean diameter and total volume concentrations at the end of the experiment. We show that in addition to self-limiting effects of IEPOX-SOA coatings, accounting for the molar balance between inorganic and organic sulfate and mass accommodation coefficient of IEPOX are important parameters governing modeling of IEPOX-SOA formation. Thus, models which do not account for the molar sulfate balance and/or diffusion limitations within IEPOX-SOA coatings are likely to predict too high IEPOX-SOA formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas delivery system for environmental transmission electron microscope

A portable, compact gas delivery system can support an environmental transmission electron microscope. Environment transmission electron microscopy provides researchers a unique capability of assessing a material's surface conditions at atomic resolution in a variety of reactive and oxidizing environments. The ability to precisely control the analysis chamber's environmental conditions over time is key to the success of a typical surface analysis. The gas delivery system provides the correct balance or pressure delivery precision, contamination control, and gas isolation.

Nogan, John Joseph↗

Performance Assessment of High-Efficiency Refrigerated Display Cases with Low-GWP Refrigerants: Preprint

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas (GHG) reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison was to assess the energy performance of two high efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513a, respectively. Performance of these display cases were compared to a baseline fixture using HFC (R-134a) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores, and small supermarkets. The high efficiency cases were equipped with energy efficient lighting, improved panel insulation, high efficiency evaporator and condenser fan motors, and high effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions. However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining target product temperature, the energy efficient fixtures containing R-290 and R-513a consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134a refrigerant. The daily energy consumption of the R-290, R-513a, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Performance Assessment of High-Efficiency Refrigerated Display Cases With Low Global Warming Potential Refrigerants

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison, was to assess the energy performance of two high-efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290, GWP = 3), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513A (GWP = 573). Performance of these display cases was compared to a baseline fixture using HFC (R-134A, GWP = 1301) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores and small supermarkets. The high-efficiency cases were equipped with energy-efficient lighting, improved panel insulation, high-efficiency evaporator and condenser fan motors, and high-effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions (ASHRAE 2018). However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining equivalent target product temperature, the energy-efficient fixtures A (containing R-290, improved insulation, heat exchangers with a higher overall heat transfer coefficient (higher UA), and more efficient lighting and fan motors) and B (containing R-513A, improved fans, and higher UA-heat exchangers, and more efficient lighting and fan motors) consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134A refrigerant. The daily energy consumption of the R-290, R-513A, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Can Isoprene Oxidation Explain High Concentrations of Atmospheric Formic and Acetic Acid over Forests?

Formic and acetic acid concentrations are particularly high over forested areas of the world. However, the gas-phase mechanisms for producing these acids are poorly understood even for isoprene, the globally dominant biogenic hydrocarbon. We quantified formic and acetic acid production from reactions of hydroxyl radical (OH) (between high and low ranges of nitric oxide (NO) levels) with isoprene, methacrolein (MACR), isoprene epoxydiol (IEPOX), isoprene hydroxy hydroperoxide (ISOPOOH), and α-pinene from the focused isoprene experiments at California Institute of Technology (FIXCIT) laboratory chamber study. We find that (i) OH oxidation of MACR, IEPOX, and ISOPOOH are sources of formic acid, (ii) isoprene peroxy radical isomerization and associated photolysis oxidation products are potentially important sources of organic acids, and (iii) high levels of NO generally suppress organic acid formation from OH oxidation of isoprene. We modified existing chemical mechanisms for isoprene oxidation to account for organic acid production pathways observed in the FIXCIT study. We simulated organic acid production during the Southeastern Oxidant and Aerosol Study using the updated chemical mechanisms and represented acetic acid within a factor of 2 but still underpredicted formic acid by a factor of 6. While we cannot explain ambient formic acid with explicit chemical mechanisms, the FIXCIT results suggest that the oxidation of isoprene could account for as much as 70% of the global annual production of formic acid from gas-phase reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ducted Fuel Injection vs. Conventional Diesel Combustion: Extending the Load Range in an Optical Engine with a Four-Orifice Fuel Injector

Ducted fuel injection (DFI) is a technique to attenuate soot formation in compression ignition engines relative to conventional diesel combustion (CDC). The concept is to inject fuel through a small tube inside the combustion chamber to reduce equivalence ratios in the autoignition zone relative to CDC. DFI has been studied at loads as high as 8.5 bar gross indicated mean effective pressure (IMEP g ) and as low as 2.5 bar IMEP g using a four-orifice fuel injector. Across previous studies, DFI has been shown to attenuate soot emissions, increase NO x emissions (at constant charge dilution), and slightly decrease fuel conversion efficiencies for most tested points. This study expands on the previous work by testing 1.1 bar IMEPg (low-load/idle) conditions and 10 bar IMEPg (higher-load) conditions with the same four-orifice fuel injector, as well as examining potential causes of the degradations in NO x emissions and fuel conversion efficiencies. DFI and CDC are directly compared at each operating point in the study. At the low-load condition, the intake charge dilution was swept to elucidate the soot and NO x performance of DFI. The low-load range is important because it is the target of impending, more-stringent emissions regulations, and DFI is shown to be a potentially effective approach for helping to meet these regulations. The results also indicate that DFI likely has slightly decreased fuel conversion efficiencies relative to CDC. We find that the increase in NO x emissions with DFI is likely due to longer charge gas residence times at higher temperatures, which arise from shorter combustion durations and advanced combustion phasing relative to CDC.

42 ENGINEERING↗

Performance Assessment of Low-GWP Refrigerated Reach-In Display Cases

This project is part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand savings potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by ComEd and CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual. In 2016, the United Nations passed the Kigali Montreal Protocol Amendment, which placed restrictions on certain types of refrigerants. In compliance with this amendment, the U.S. Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives.

alternative refrigerants↗

Vegetation Warming Experiment: Plant Physiology, Utqiagvik (Barrow), Alaska, 2021

Leaf gas exchange measurements on Carex aquatilis Wahlenb. following a single season warming treatment. Data were collected in 2021 from 5 treatment warming chambers and paired control plots located on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska. Data include CO2 response (ACi) curves, light response (AQ) curves, and dark-adapted respiration (Rdark) logged data measured at controlled leaf temperatures from 5–25 °C. The data package includes 4 data files in .csv format, 10 metadata files and the complete instrument output for all measurements. These data were collected as part of an experiment using Zero Power Warming (ZPW) chambers that delivered a single season warming treatment of ~4 °C above ambient air temperature. Four different plant species were targeted over four experimental years from 2017–2021. See related data packages for processed gas exchange data, leaf trait data (leaf mass per area, leaf nitrogen concentration), ambient and chamber environmental conditions, phenocamera images, thaw depth and GPS locations of chambers. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Vegetation Warming Experiment: Plant Physiology, Utqiagvik (Barrow), Alaska, 2017

Leaf gas exchange measurements on Petasites frigidus (L.) Fr. following a single season warming treatment. Data were collected in 2017 from 5 treatment warming chambers and paired control plots located on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska. Data include CO2 response (ACi) curves, light response (AQ) curves, and dark-adapted respiration (Rdark) logged data measured at controlled leaf temperatures from 5-25 °C. The data package includes 4 data files in .csv format, 10 metadata files and the complete instrument output for all measurements. These data were collected as part of an experiment using Zero Power Warming (ZPW) chambers that delivered a single season warming treatment of ~4 °C above ambient air temperature. Four different plant species were targeted over four experimental years from 2017-2021. See related data packages for processed gas exchange data, leaf trait data (leaf mass per area, leaf nitrogen concentration), ambient and chamber environmental conditions, phenocamera images, thaw depth and GPS locations of chambers. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗