Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error Floors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR {sup 192}Ir Brachytherapy Source

High-dose rate (HDR) {sup 192}Ir brachytherapy sources are commonly used for management of malignancies by brachytherapy applications. Measurement of source strength at the hospital is an important dosimetry requirement. The use of 0.6-cm{sup 3} cylindrical ionization chamber is one of the methods of measuring the source strength at the hospitals because this chamber is readily available for beam calibration and dosimetry. While using the cylindrical chamber for this purpose, it is also required to determine the positioning error of the ionization chamber, with respect to the source, commonly called a distance error (c). The contribution of scatter radiation (M{sub s}) from floor, walls, ceiling, and other materials available in the treatment room also need to be determined accurately so that appropriate correction can be applied while calculating the source strength from the meter reading. Iterative methods of Newton-Raphson and least-squares were used in this work to determine scatter contribution in the experimentally observed meter reading (pC/s) of a cylindrical ionization chamber. Monte Carlo simulation was also used to cross verify the results of the least-squares method. The experimentally observed, least-squares calculated and Monte Carlo estimated values of meter readings from HDR {sup 192}Ir brachytherapy source were in good agreement. Considering procedural simplicity, the method of least-squares is recommended for use at the hospitals to estimate values of f (constant of proportionality), c, and M{sub s} required to determine the strength of HDR {sup 192}Ir brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

Visual Orientation in Unfamiliar Gravito-Inertial Environments

The goal of this project is to better understand the process of spatial orientation and navigation in unfamiliar gravito-inertial environments, and ultimately to use this new information to develop effective countermeasures against the orientation and navigation problems experienced by astronauts. How do we know our location, orientation, and motion of our body with respect to the external environment ? On earth, gravity provides a convenient "down" cue. Large body rotations normally occur only in a horizontal plane. In space, the gravitational down cue is absent. When astronauts roll or pitch upside down, they must recognize where things are around them by a process of mental rotation which involves three dimensions, rather than just one. While working in unfamiliar situations they occasionally misinterpret visual cues and experience striking "visual reorientation illusions" (VRIs), in which the walls, ceiling, and floors of the spacecraft exchange subjective identities. VRIs cause disorientation, reaching errors, trigger attacks of space motion sickness, and potentially complicate emergency escape. MIR crewmembers report that 3D relationships between modules - particularly those with different visual verticals - are difficult to visualize, and so navigating through the node that connects them is not instinctive. Crew members learn routes, but their apparent lack of survey knowledge is a concern should fire, power loss, or depressurization limit visibility. Anecdotally, experience in mockups, parabolic flight, neutral buoyancy and virtual reality (VR) simulators helps. However, no techniques have been developed to quantify individual differences in orientation and navigation abilities, or the effectiveness of preflight visual. orientation training. Our understanding of the underlying physiology - for example how our sense of place and orientation is neurally coded in three dimensions in the limbic system of the brain - is incomplete. During the 16 months that this human and animal research project has been underway, we have obtained several results that are not only of basic research interest, but which have practical implications for the architecture and layout of spacecraft interiors and for the development of astronaut spatial orientation training countermeasures.

Oman, Charles M.↗

Stratospheric temperature measurements from nanosatellite stellar occultation observations of refractive bending

Abstract. Stellar occultation observations from space can probe the stratosphere and mesosphere at a fine vertical scale around the globe. Unlike other measurement techniques like radiosondes and aircraft, stellar occultation has the potential to observe the atmosphere above 30 km, and unlike radio occultation, stellar occultation probes fine-scale phenomena with potential to observe atmospheric turbulence. We imaged the refractive bending angle of a star centroid for a series of occultations by the atmosphere. Atmospheric refractivity, density, and then temperature are retrieved from the bending observations with the Abel transformation and Edlén's law, the hydrostatic equation, and the ideal gas law. The retrieval technique is applied to data collected by two nanosatellites operated by Terran Orbital. Measurements were primarily taken by the GEOStare SV2 mission, with a dedicated imaging telescope, supplemented with images captured by spacecraft bus sensors, namely the star trackers on other Terran Orbital missions. The bending angle noise floor is 10 and 30 arcsec for the star tracker and GEOStare SV2 data, respectively. The most significant sources of uncertainty are due to centroiding errors due to the fairly low-resolution stellar images and telescope pointing knowledge derived from noisy satellite attitude sensors. The former mainly affects the star tracker data, while the latter limits the GEOStare SV2 accuracy, with both providing low vertical resolution. This translates to a temperature profile retrieval up to roughly 20 km for both star tracker and GEOStare SV2 datasets. In preparation of an upcoming 2023 mission designed to correct these deficiencies, SOHIP, we simulated bending angle measurements with varying magnitudes of error. The expected maximum altitude of retrieved temperature is 41 km on average for these simulated measurements with a noise floor of 0.39 arcsec. Our work highlights the capabilities of stellar occultation observations from nanosatellites for atmospheric sounding. Future work will investigate high-frequency observations of atmospheric gravity waves and turbulence, mitigating the major uncertainties observed in these datasets.

54 ENVIRONMENTAL SCIENCES↗

High-bandwidth polarimeter for a high density, accelerated spheromak

A three-beam heterodyne polarimeter has been built to diagnose the PI-1 plasma injector at General Fusion, Inc. The polarimeter measures plasma density and Faraday rotation, which can provide estimates of magnetic field magnitude and direction. Two important calibration steps are required for the polarimeter to produce reasonable Faraday rotation signals. Beam polarization ellipticity must be measured to ensure there is a linear Faraday rotation response. In addition, the two beams travelling through the plasma must be collinear to reduce error due to differences in plasma density. Once calibrated, the Faraday rotation signals are in much better agreement with other diagnostics. For a null signal, the Faraday rotation measurement noise floor is 0.1° at 0.5 MHz bandwidth. Comparing preliminary spheromak Faraday rotation measurements to a model, the maximum error is about 0.3° at 0.5 MHz bandwidth, which is primarily due to electrical noise during the injector's capacitor discharge and limitations of the model. At a bandwidth of 0.5 MHz, the polarimeter has an axial resolution between 6 cm and 30 cm depending on the speed of the spheromak, which varies between 30 km/s and 150 km/s. The spheromak length ranges from 0.75 m to 2 m. Additional polarimeter chords will be added in future upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-D-213-07: RadShield: Semi- Automated Calculation of Air Kerma Rate and Barrier Thickness

Purpose: To develop the first Java-based semi-automated calculation program intended to aid professional radiation shielding design. Air-kerma rate and barrier thickness calculations are performed by implementing NCRP Report 147 formalism into a Graphical User Interface (GUI). The ultimate aim of this newly created software package is to reduce errors and improve radiographic and fluoroscopic room designs over manual approaches. Methods: Floor plans are first imported as images into the RadShield software program. These plans serve as templates for drawing barriers, occupied regions and x-ray tube locations. We have implemented sub-GUIs that allow the specification in regions and equipment for occupancy factors, design goals, number of patients, primary beam directions, source-to-patient distances and workload distributions. Once the user enters the above parameters, the program automatically calculates air-kerma rate at sampled points beyond all barriers. For each sample point, a corresponding minimum barrier thickness is calculated to meet the design goal. RadShield allows control over preshielding, sample point location and material types. Results: A functional GUI package was developed and tested. Examination of sample walls and source distributions yields a maximum percent difference of less than 0.1% between hand-calculated air-kerma rates and RadShield. Conclusion: The initial results demonstrated that RadShield calculates air-kerma rates and required barrier thicknesses with reliable accuracy and can be used to make radiation shielding design more efficient and accurate. This newly developed approach differs from conventional calculation methods in that it finds air-kerma rates and thickness requirements for many points outside the barriers, stores the information and selects the largest value needed to comply with NCRP Report 147 design goals. Floor plans, parameters, designs and reports can be saved and accessed later for modification and recalculation. We have confirmed that this software accurately calculates air-kerma rates and required barrier thicknesses for diagnostic radiography and fluoroscopic rooms.

07 ISOTOPE AND RADIATION SOURCES↗

Multiple Explanations for the Single Transit of KIC 5951458 Based on Radial Velocity Measurements Extracted with a Novel Matched-template Technique

Planetary systems that show single-transit events are a critical pathway to increasing the yield of long-period exoplanets from transit surveys. From the primary Kepler mission, KIC 5951458 b (Kepler-456b) was thought to be a single-transit giant planet with an orbital period of 1310 days. However, radial velocity (RV) observations of KIC 5951458 from the HIRES instrument on the Keck telescope suggest that the system is far more complicated. To extract precise RVs for this V≈13 star, we develop a novel matched-template technique that takes advantage of a broad library of template spectra acquired with HIRES. We validate this technique and measure its noise floor to be 4–8 m s{sup −1} (in addition to internal RV error) for most stars that would be targeted for precision RVs. For KIC 5951458, we detect a long-term RV trend that suggests the existence of a stellar companion with an orbital period greater than a few thousand days. We also detect an additional signal in the RVs that is possibly caused by a planetary or brown dwarf companion with mass in the range of 0.6–82 M {sub Jup} and orbital period below a few thousand days. Curiously, from just the data on hand, it is not possible to determine which object caused the single “transit” event. We demonstrate how a modest set of RVs allows us to update the properties of this unusual system and predict the optimal timing for future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Reliability and Stability of VLBI-Derived Sub-Daily EOP Models

Recent investigations have shown significant shortcomings in the model which is proposed by the IERS to account for the variations in the Earth s rotation with periods around one day and less. To overcome this, an empirical model can be estimated more or less directly from the observations of space geodetic techniques. The aim of this paper is to evaluate the quality and reliability of such a model based on VLBI observations. Therefore, the impact of the estimation method and the analysis options as well as the temporal stability are investigated. It turned out that, in order to provide a realistic accuracy measure of the model coefficients, the formal errors should be inflated by a factor of three. This coincides with the noise floor and the repeatability of the model coefficients and it captures almost all of the differences that are caused by different estimation techniques. The impact of analysis options is small but significant when changing troposphere parameterization or including harmonic station position variations.

Artz, Thomas↗

WFIRST Coronagraph: Digging Dark-Holes with Partially Corrected Pupil Phase

The WFIRST coronagraph employs two sequential deformable mirrors to compensate for phase and amplitude errors in the coronagraph optical system. In such a system the actuators of the deformable mirrors would be used for two purposes: To flatten the overall wavefront errors at a system pupil, and to create "dark-holes". The actuators have limited stroke ranges. Therefore, if the pupil phase errors are relatively large, flattening them completely could use up a significant portion of the actuator stroke, sometimes leaving insufficient stroke for creating the dark-holes. We have investigated the impact of partially-corrected pupil phase errors on a Hybrid Lyot Coronagraph (HLC) broadband contrast performance. The predicted broadband contrast floor and the contrast chromaticity agree well with those measured on the HLC testbed.

Poberezhskiy, Ilya↗

Welding technology transfer task/laser based weld joint tracking system for compressor girth welds

Sensors to control and monitor welding operations are currently being developed at Marshall Space Flight Center. The laser based weld bead profiler/torch rotation sensor was modified to provide a weld joint tracking system for compressor girth welds. The tracking system features a precision laser based vision sensor, automated two-axis machine motion, and an industrial PC controller. The system benefits are elimination of weld repairs caused by joint tracking errors which reduces manufacturing costs and increases production output, simplification of tooling, and free costly manufacturing floor space.

Looney, Alan↗

On the synchronizability and detectability of random PPM sequences

The problem of synchronization and detection of random pulse-position-modulation (PPM) sequences is investigated under the assumption of perfect slot synchronization. Maximum-likelihood PPM symbol synchronization and receiver algorithms are derived that make decisions based both on soft as well as hard data; these algorithms are seen to be easily implementable. Bounds derived on the symbol error probability as well as the probability of false synchronization indicate the existence of a rather severe performance floor, which can easily be the limiting factor in the overall system performance. The performance floor is inherent in the PPM format and random data and becomes more serious as the PPM alphabet size Q is increased. A way to eliminate the performance floor is suggested by inserting special PPM symbols in the random data stream.

Georghiades, Costas N.↗

Closing the Contrast Gap Between Testbed and Model Prediction with WFIRST-CGI Shaped Pupil Coronagraph

JPL has recently passed an important milestone in its technology development for a proposed NASA WFIRST mission: demonstration of a better than 1x10-8 contrast over broad bandwidth (10%) on both shaped pupil coronagraph (SPC) and hybrid Lyot coronagraph (HLC) testbeds with WFIRST telescope optics. Challenges remain, however, in the technology readiness for the proposed mission. One such is the discrepancy between the achieved contrast on testbeds and their corresponding model predictions. A series of testbed diagnosis and modeling activity were planned and (some) carried out on SPC testbed in order to close the gap. A very useful tool we developed was to analyze the measured testbed Jacobian and compare with its model version that was used to control image plane speckle pattern. The difference between these two is the error in the control Jacobian. When the error, which includes both amplitude and phase, was inserted into a separate prediction model with nominal Jacobian, the model prediction became closely matching the SPC testbed behavior in both contrast floor and contrast convergence speed. This offers a new perspective and is a step closer toward model validation for high contrast coronagraph. Further Jacobian analysis and modeling provided clues to the possible sources for the mismatch: the DM misregistration and the underrepresented testbed optics wavefront error (WFE) and the deformable mirror (DM) setting for correcting this WFE. These analyses suggested that high contrast coronagraph has a tight tolerance in the accuracy of its control Jacobian. Modifications to both testbed control model as well as prediction model are being implemented and future works discussed.

diffraction modeling↗

Mirror Surface Contamination Specification Derived from Coronagraphy Scatter Error Budget Allocation

Near-Angle Scatter (NAS) of the host star’s light may limit the ability of a potential Habitable Worlds Observatory (HWO) to detect and characterize an Earth-like planet around a Sun-like star via coronagraphy. NAS from each optical surface before the coronagraph’s focal plane mask produces an E-field across the dark hole that is coherent. These E-fields sum and could be as large or larger than the coronagraph mask leakage E-field. This paper assumes an error budget allocation for scatter of 20 ppt. NAS E-fields contribute to the dark hole noise floor via both shot noise and heterodyne amplification of the wavefront instability. While previous papers have developed specifications for scatter from surface scatter, this paper develops specifications for scatter from surface contamination and micrometeoroid impacts. The development process utilizes an expression that predicts scatter throughput into the dark hole based on surface BRDF. Analysis does not include scatter from coating columnar structure, edges, contamination, micrometeoroid impacts, or polarization.

near angle scatter↗

3D Measurement Simulation and Relative Pointing Error Verification of the Telescope Mount Assembly Subsystem for the Large Synoptic Survey Telescope

An engineering validation of a large optical telescope consists of executing major performing tests at the subsystem level to verify the overall engineering performance of the observatory. Thus, the relative pointing error verification of the telescope mount assembly subsystem is of special interest to guarantee the absolute pointing performance of the large synoptic survey telescope. This paper presents a new verification method for the relative pointing error assessment of the telescope mount assembly, based on laser tracker technology and several fiducial points fixed to the floor. Monte-Carlo-based simulation results show that the presented methodology is fit for purpose, even if floor movement occurs due to temperature variation during the measurement acquisition process. A further research about laser tracker technology integration into the telescope structure may suggest that such laser tracker technology could be permanently installed in the telescope in order to provide an active alignment system that aims to detect and correct possible misalignment between mirrors or to provide the required mirror positioning verification accuracy after maintenance activities. The obtained results show that two on-board laser tracker systems combined with eight measurement targets could result in measurement uncertainties that are better than 1 arcsec, which would provide a reliable built-in metrology tool for large telescopes.

47 OTHER INSTRUMENTATION↗

Description of recent changes in the Langley 6- by 28-inch transonic tunnel

Calibrations were obtained in the Langley 6 by 28-inch transonic tunnel with newly installed controllable reentry flaps and test section floor and ceiling. Using available theory, the top and bottom slotted walls were redesigned for minimum wind tunnel interference errors of blockage and stream-line curvature. To minimize Mach number gradients along the tunnel axis downstream of the model, controllable flaps were installed to regulate the flow reentering the test section through the slotted walls. The flap setting is independent of stagnation pressure and varies only with Mach number. The freestream Mach number is determined from the pressrue measured at a station 66.04 cm upstream of the model station. The model has no significant influence on the vertical Mach number distribution at this station. This method of Mach number determination appears to be more accurate than one using the plenum pressure.

Sewall, W. G.↗

On the synchronizability and detectability of random PPM sequences

The problem of synchronization and detection of random pulse-position-modulation (PPM) sequences is investigated under the assumption of perfect slot synchronization. Maximum likelihood PPM symbol synchronization and receiver algorithms are derived that make decisions based both on soft as well as hard data; these algorithms are seen to be easily implementable. Bounds were derived on the symbol error probability as well as the probability of false synchronization that indicate the existence of a rather severe performance floor, which can easily be the limiting factor in the overall system performance. The performance floor is inherent in the PPM format and random data and becomes more serious as the PPM alphabet size Q is increased. A way to eliminate the performance floor is suggested by inserting special PPM symbols in the random data stream.

Georghiades, Costas N.↗

On the synchronizability and detectability of random PPM sequences

The problem of synchronization and detection of random pulse-position modulation (PPM) sequences is investigated under the assumption of perfect slot synchronization. Maximum-likelihood PPM symbol synchronization and receiver algorithms are derived that make decisions based on both soft as well as hard data; these algorithms are seen to be easily implementable. Bounds were derived on the symbol error probability as well as the probability of false synchronization that indicate the existence of a rather severe performance floor, which can easily be the limiting factor in the overall system performance. The performance floor is inherent in the PPM format and random data and becomes more serious as the PPM alphabet size Q is increased. A way to eliminate the performance floor is suggested by inserting special PPM symbols in the random data stream.

Georghiades, Costas N.↗

Exploring the Relationship Between Reflectance Red Edge and Chlorophyll Content in Slash Pine

Chlorophyll is a key indicator of the physiological status of a forest canopy. However, its distribution may vary greatly in time and space, so that the estimation of chlorophyll content of canopies or branches by extrapolation from leaf values obtained by destructive sampling is labor intensive and potentially inaccurate. Chlorophy11 content is related positively to the point of maximum slope in vegetation reflectance spectra which occurs at wavelengths between 690-740 nm and is known as the "red edge." The red edge of needles on individual slash pine (Piniis elliottii Engelm.) branches and in whole forest canopies was measured with a spectroradiometer. Branches were measured on the ground against a spectrally flat reflectance target and canopies were measured from observation towers against a spectrally variable understory and forest floor. There was a linear relationship between red edge and chlorophyll content of branches (R(exp 2) = 0.91). Measurements of the red edge and this relationship were used to estimate the chlorophyll content of other branches with an error that was lower than that associated with the colorimetric (laboratory) method. There was no relationship between the red edge and the chlorophyll content of whole canopies. This can be explained by the overriding influence of the understory and forest floor, an influence that was illustrated by spectral mixture modeling. The results suggest that the red edge could be used to estimate the chlorophyll content in branches but it is unlikely to be of value for the estimation of chlorophyll content in canopies unless the canopy cover is high.

Curran, Paul J.↗

An experimental investigation of the aerodynamics of a NACA 64A010 airfoil-flap combination with and without flap oscillations. Part 1: Steady-state characteristics

A NACA 64A010 airfoil with a sealed-gap 1/4-chord flap was tested between splitter plates in the NASA Ames 11- by 11-Foot Transonic Wind Tunnel at Mach numbers from 0.50 to 0.85, and Reynolds numbers based on chord from 3 to 13 million. Although the main purpose of the test was to obtain unsteady pressure data with the flap oscillating, no unsteady data are presented in this paper. The steady-state data are presented and compared with other test data to provide a basis for evaluating the results. Pressure data at two span stations are used to deduce early boundary-layer transitions at the midspan at higher Mach numbers, angles of attack, and flap angles. The effects of flap angle on pressures, normal force, pitching moment, and hinge moment are also presented in the report. Mach number errors caused by the splitter-plate configuration and the angle of attack are evaluated using pressure measurements near the floor and ceiling of the wind tunnel.

Buell, Donald A.↗