Search NASA⌕ Search

SEARCH · Search NASA

Results for “Experiment Guide Tube”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The KATRIN superconducting magnets: Overview and first performance results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

47 OTHER INSTRUMENTATION↗

A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Small-Scale Drying: FY2020 Interim Report

This report documents the interim experimental status of small-scale drying tests currently being performed at Pacific Northwest National Laboratory. These small-scale drying tests are to develop the technical bases for sensors, techniques, and approaches that will be used to address the challenges faced when determining moisture content from gas samples taken at the North Anna Nuclear Generating Station for the High Burnup Demonstration Project. Specifically, the purpose of these tests is to support Sandia National Laboratories gas sample methods and analyses through a series of small-scale experiments. Key focus areas include performing tests to: • Correlate sample bottle measurements to in-cask conditions • Estimate the amount of trapped and absorbed water on cask features and surfaces that can contribute to water vapor • Assess the accuracy of the hygrometer used in the measurements under similar conditions • Identify additional methods for measuring humidity in casks easily and accurately using lessons-learned from Sandia National Laboratories, including direct gravimetric and isotopic tracer techniques. To address these topics this report outlines a series of five tests and any data collected to date that were planned for FY 2020 that include 1) humidity measurement method development, 2) gas bottle sampling tests, 3) surface drying tests on cladding, 4) small-scale drying of cladding, and 5) small-scale drying of guide-tube/dashpots. This interim report documents the experimental background, design and progress of these small-scale drying tests. Further data gathered will be summarized in the FY 2021 report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Atom Skimmers and Atom Lasers Utilizing Them

Atom skimmers are devices that act as low-pass velocity filters for atoms in thermal atomic beams. An atom skimmer operating in conjunction with a suitable thermal atomic-beam source (e.g., an oven in which cesium is heated) can serve as a source of slow atoms for a magneto-optical trap or other apparatus in an atomic-physics experiment. Phenomena that are studied in such apparatuses include Bose-Einstein condensation of atomic gases, spectra of trapped atoms, and collisions of slowly moving atoms. An atom skimmer includes a curved, low-thermal-conduction tube that leads from the outlet of a thermal atomic-beam source to the inlet of a magneto-optical trap or other device in which the selected low-velocity atoms are to be used. Permanent rare-earth magnets are placed around the tube in a yoke of high-magnetic-permeability material to establish a quadrupole or octupole magnetic field leading from the source to the trap. The atoms are attracted to the locus of minimum magnetic-field intensity in the middle of the tube, and the gradient of the magnetic field provides centripetal force that guides the atoms around the curve along the axis of the tube. The threshold velocity for guiding is dictated by the gradient of the magnetic field and the radius of curvature of the tube. Atoms moving at lesser velocities are successfully guided; faster atoms strike the tube wall and are lost from the beam.

Hulet, Randall↗

Mechanical failure of fresh nuclear grade iron–chromium–aluminum (FeCrAl) cladding under simulated hot zero power reactivity initiated accident conditions

The reactivity initiated accident (RIA) is a postulated accident in light water reactors initiated by a rapid increase in reactivity which causes an increase in fission rate and fuel temperature. One potential mode of fuel system failure during RIA is pellet cladding mechanical interaction (PCMI) due to the rapid thermal expansion of the fuel pellet. Simulated PCMI experiments were performed by rapidly pressurizing iron-chromium-aluminum (FeCrAl) cladding tube samples using a hydraulic modified burst test system, causing the specimens to burst under a biaxial loading path. Deformation and rupture of the specimens were tracked with a telecentric lens and high-speed camera system. Outer surface strains were calculated using digital image correlation (DIC) on speckle patterns painted on the specimens’ outer surfaces. Experiments were conducted at approximately 275 °C, representative of hot zero power RIA conditions. The failure hoop strain was DIC-calculated between approximately 1.8–3.4%, corresponding to quasi-static energy depositions of approximately 110–260 calories per gram UO 2 assuming initial pellet-cladding contact. These conditions are very similar to the proposed energy deposition limit of 150 calories per gram UO 2 for unirradiated zirconium-based cladding in US Nuclear Regulatory Commission (NRC) Draft Regulatory Guide 1327. A very small strain rate dependence was observed in the data, with the magnitude of the failure hoop strain decreasing slightly with increasing strain rate. This observed dependence may be relevant because the FeCrAl cladding strain rate will be approximately 20% higher than in zirconium-based cladding due to the harder neutron spectrum and resultant shorter neutron generation time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements of Turbulence Attenuation by a Dilute Dispersion of Solid Particles in Homogeneous Isotropic Turbulence

This research addresses turbulent gas flows laden with fine solid particles at sufficiently large mass loading that strong two-way coupling occurs. By two-way coupling we mean that the particle motion is governed largely by the flow, while the particles affect the gas-phase mean flow and the turbulence properties. Our main interest is in understanding how the particles affect the turbulence. Computational techniques have been developed which can accurately predict flows carrying particles that are much smaller than the smallest scales of turbulence. Also, advanced computational techniques and burgeoning computer resources make it feasible to fully resolve very large particles moving through turbulent flows. However, flows with particle diameters of the same order as the Kolmogorov scale of the turbulence are notoriously difficult to predict. Some simple flows show strong turbulence attenuation with reductions in the turbulent kinetic energy by up to a factor of five. On the other hand, some seemingly similar flows show almost no modification. No model has been proposed that allows prediction of when the strong attenuation will occur. Unfortunately, many technological and natural two-phase flows fall into this regime, so there is a strong need for new physical understanding and modeling capability. Our objective is to study the simplest possible turbulent particle-laden flow, namely homogeneous, isotropic turbulence with a uniform dispersion of monodisperse particles. We chose such a simple flow for two reasons. First, the simplicity allows us to probe the interaction in more detail and offers analytical simplicity in interpreting the results. Secondly, this flow can be addressed by numerical simulation, and many research groups are already working on calculating the flow. Our detailed data can help guide some of these efforts. By using microgravity, we can further simplify the flow to the case of no mean velocity for either the turbulence or the particles. In fact the addition of gravity as a variable parameter may help us to better understand the physics of turbulence attenuation. The experiments are conducted in a turbulence chamber capable of producing stationary or decaying isotropic turbulence with nearly zero mean flow and Taylor microscale Reynolds numbers up to nearly 500. The chamber is a 410 mm cubic box with the corners cut off to make it approximately spherical. Synthetic jet turbulence generators are mounted in each of the eight corners of the box. Each generator consists of a loudspeaker forcing a plenum and producing a pulsed jet through a 20 mm diameter orifice. These synthetic jets are directed into ejector tubes pointing towards the chamber center. The ejector tubes increase the jet mass flow and decrease the velocity. The jets then pass through a turbulence grid. Each of the eight loudspeakers is forced with a random phase and frequency. The resulting turbulence is highly Isotropic and matches typical behavior of grid turbulence. Measurements of both phases are acquired using particle image velocimetry (PIV). The gas is seeded with approximately 1 micron diameter seeding particles while the solid phase is typically 150 micron diameter spherical glass particles. A double-pulsed YAG laser and a Kodak ES-1.0 10-bit PIV camera provide the PIV images. Custom software is used to separate the images into individual images containing either gas-phase tracers or large particles. Modern high-resolution PIV algorithms are then used to calculate the velocity field. A large set of image pairs are acquired for each case, then the results are averaged both spatially and over the ensemble of acquired images. The entire apparatus is mounted in two racks which are carried aboard NASA's KC-135 Flying Microgravity Laboratory. The rack containing the turbulence chamber, the laser head, and the camera floats freely in the airplane cabin (constrained by competent NASA personnel) to minimize g-jitter.

Eaton, John↗

Design of the Electromagnetic Particle Injector (EPI) for Tokamak Deployment

Both predicting and controlling disruptions are critical and urgent issues for ITER as some disruptions with a short warning time may be unavoidable. For these cases, a rapid response disruption mitigation system (DMS) referred to as the electromagnetic particle injector (EPI) is being developed. The primary advantages of the EPI are its fast response time and high velocity, which have been demonstrated in offline experiments (Raman et al., 2021). The EPI is capable of accelerating a metallic sabot electromagnetically using a rail gun to the required velocities ( > 2 km/s) within 2 ms. Two high-field racetrack magnets able to generate fields over 2 T are positioned above and below the rails to permit high velocity at low rail currents, a requirement to minimize electrode erosion. At the end of the acceleration phase, a sabot capture mechanism retains the spent sabot inside the vacuum chamber that houses the EPI. At this point, it releases well-defined microspheres, or a shell pellet, of a radiative payload into the disrupting plasma. A remotely operated sabot loading system positioned behind the injector contains several pre-equipped sabots that can be loaded by an operator from the tokamak control room. The injector is interfaced to the tokamak through a guide tube attached to the front of the EPI vacuum chamber. Finally, the advantages of the EPI system over other DMSs under consideration are described in conjunction with the details of an EPI system designed for near-term test on an existing large tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Method to Design and Optimize Axial Flow Cyclones for Gas–Liquid Separation

This article provides a detailed design guide, optimization, and performance assessment for air–water separation of an axial flow cyclone. Axial flow cyclones (also known as swirl tube demisters, mist eliminators, or Austin–Write cyclones) have a range of applications in several different industries. This method of gas–liquid separation offers many benefits. Among these are high liquid separation efficiencies (near 99%) and an inline design that allows them to be more easily fitted into existing piping structures. Despite these benefits, there are several design parameters that have not been optimized for performance in wastewater purification applications. This research fills the gap in the literature by quantifying the effect of new design parameters on water collection efficiency, η water collection , and the air bypass efficiency, η air bypass , defined as the ratio of the air mass flowrate exiting through the desired air outlet over the inlet air mass flowrate. A set of wide-ranging experiments were conducted to study the effects of gas–liquid flow rates, tube geometry, and relative injection angles to optimize the water collection and air bypass efficiencies. The water collection efficiency exceeded 99.8% when the liquid streamline came in direct contact with the water drainage exit. An empirical correlation was developed to predict the swirl pitch as a function of the above design parameters. Predictions from the correlation were within 10% of the experimental results. The correlation can be used to design highly efficient in-line gas–liquid separators.

Engineering↗

Uncertainty and Sensitivity Analyses of a Two-Parameter Impedance Prediction Model

This paper presents comparisons of predicted impedance uncertainty limits derived from Monte-Carlo-type simulations with a Two-Parameter (TP) impedance prediction model and measured impedance uncertainty limits based on multiple tests acquired in NASA Langley test rigs. These predicted and measured impedance uncertainty limits are used to evaluate the effects of simultaneous randomization of each input parameter for the impedance prediction and measurement processes. A sensitivity analysis is then used to further evaluate the TP prediction model by varying its input parameters on an individual basis. The variation imposed on the input parameters is based on measurements conducted with multiple tests in the NASA Langley normal incidence and grazing incidence impedance tubes; thus, the input parameters are assigned uncertainties commensurate with those of the measured data. These same measured data are used with the NASA Langley impedance measurement (eduction) processes to determine the corresponding measured impedance uncertainty limits, such that the predicted and measured impedance uncertainty limits (95% confidence intervals) can be compared. The measured reactance 95% confidence intervals encompass the corresponding predicted reactance confidence intervals over the frequency range of interest. The same is true for the confidence intervals of the measured and predicted resistance at near-resonance frequencies, but the predicted resistance confidence intervals are lower than the measured resistance confidence intervals (no overlap) at frequencies away from resonance. A sensitivity analysis indicates the discharge coefficient uncertainty is the major contributor to uncertainty in the predicted impedances for the perforate-over-honeycomb liner used in this study. This insight regarding the relative importance of each input parameter will be used to guide the design of experiments with test rigs currently being brought on-line at NASA Langley.

Jones, M. G.↗

Flexible radioluminescence imaging for FDG-guided surgery

Purpose: Flexible radioluminescence imaging (Flex-RLI) is an optical method for imaging {sup 18}F-fluorodeoxyglucose (FDG)-avid tumors. The authors hypothesize that a gadolinium oxysulfide: terbium (GOS:Tb) flexible scintillator, which loosely conforms to the body contour, can enhance tumor signal-to-background ratio (SBR) compared with RLI, which utilizes a flat scintillator. The purpose of this paper is to characterize flex-RLI with respect to alternative modalities including RLI, beta-RLI (RLI with gamma rejection), and Cerenkov luminescence imaging (CLI). Methods: The photon sensitivity, spatial resolution, and signal linearity of flex-RLI were characterized with in vitro phantoms. In vivo experiments utilizing 13 nude mice inoculated with the head and neck (UMSCC1-Luc) cell line were then conducted in accordance with the institutional Administrative Panel on Laboratory Animal Care. After intravenous injection of {sup 18}F-FDG, the tumor SBR values for flex-RLI were compared to those for RLI, beta-RLI, and CLI using the Wilcoxon signed rank test. Results: With respect to photon sensitivity, RLI, beta-RLI, and flex-RLI produced 1216.2, 407.0, and 98.6 times more radiance per second than CLI. Respective full-width half maximum values across a 0.5 mm capillary tube were 6.9, 6.4, 2.2, and 1.5 mm, respectively. Flex-RLI demonstrated a near perfect correlation with {sup 18}F activity (r = 0.99). Signal uniformity for flex-RLI improved after more aggressive homogenization of the GOS powder with the silicone elastomer during formulation. In vivo, the SBR value for flex-RLI (median 1.29; interquartile range 1.18–1.36) was statistically greater than that for RLI (1.08; 1.02–1.14; p < 0.01) by 26%. However, there was no statistically significant difference in SBR values between flex-RLI and beta-RLI (p = 0.92). Furthermore, there was no statistically significant difference in SBR values between flex-RLI and CLI (p = 0.11) in a more limited dataset. Conclusions: Flex-RLI provides high quality images with SBRs comparable to those from CLI and beta-RLI in a single 10 s acquisition.

60 APPLIED LIFE SCIENCES↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and application of a quasistatic crush test fixture for investigating scale effects in energy absorbing composite plates

A crush test fixture for measuring energy absorption of flat plate specimens from an earlier study was redesigned to eliminate the problem of binding of the load transfer platen with the guide posts. Further modifications were to increase the stroke, and combine the two scaled text fixtures into one. This new crush text fixture was shown to produce load-displacement histories exhibiting well developed sustained crushing loads over long strokes. An experimental study was conducted on two material systems: AS4/3502 graphite/epoxy, and a hybrid AS4-Kevlar/3502 composite. The effect of geometric scaling of specimen size, the effect of ply level and sublaminate-level scaling of the stacking sequence of the full scale specimens, and the effect of trigger mechanism on the energy absorption capability were investigated. The new crush test fixture and flat plate specimens produced peak and sustained crushing loads that were lower than obtained with the old crush text fixture. The trigger mechanism used influenced the specific sustained crushing stress (SSCS). The results indicated that to avoid any reduction in the SSCS when scaling from the 1/2 scale to full scale specimen size, the sublaminate-level scaling approach should be used, in agreement with experiments on tubes. The use of Kevlar in place of the graphite 45 deg plies was not as effective a means for supporting and containing the 0 deg graphite plies for rushing of flat plates and resulted in a drop in the SSCS. This result did not correlate with that obtained for tubes.

Lavoie, J. Andre↗

Mapping the performance of a versatile water-based condensation particle counter (vWCPC) with numerical simulation and experimental study

Accurate airborne aerosol instrumentation is required to determine the spatial distribution of ambient aerosol particles, particularly when dealing with the complex vertical profiles and horizontal variations of atmospheric aerosols. A versatile water-based condensation particle counter (vWCPC) has been developed to provide aerosol concentration measurements under various environments with the advantage of reducing the health and safety concerns associated with using butanol or other chemicals as the working fluid. However, the airborne deployment of vWCPCs is relatively limited due to the lack of characterization of vWCPC performance at reduced pressures. Given the complex combinations of operating parameters in vWCPCs, modeling studies have advantages in mapping vWCPC performance. In this work, we thoroughly investigated the performance of a laminar-flow vWCPC using COMSOL Multiphysics® simulation coupled with MATLAB™. We compared it against a modified vWCPC (vWCPC model 3789, TSI, Shoreview, MN, USA). Our simulation determined the performance of particle activation and droplet growth in the vWCPC growth tube, including the supersaturation, $D$ p,kel,0 (smallest size of particle that can be activated), $D$ p,kel,50 (particle size activated with 50 % efficiency) profile, and final growth particle size D d under wide operating temperatures, inlet pressures $P$ (30–101 kPa), and growth tube geometry (diameter $D$ and initiator length $L$ ini ). The effect of inlet pressure and conditioner temperature on vWCPC 3789 performance was also examined and compared with laboratory experiments. The COMSOL simulation result showed that increasing the temperature difference (Δ$T$) between conditioner temperature $T$ con and initiator $T$ ini will reduce $D$ p,kel,0 and the cut-off size $D$ p,kel,50 of the vWCPC. In addition, lowering the temperature midpoint ($T$ mid = $\frac{T_{con}+T_{ini}}{2}$ increases the supersaturation and slightly decreases the $D$ p,kel . The droplet size at the end of the growth tube is not significantly dependent on raising or lowering the temperature midpoint but significantly decreases at reduced inlet pressure, which indirectly alters the vWCPC empirical cut-off size. Our study shows that the current simulated growth tube geometry ($D$=6.3 mm and $L$ ini =30 mm) is an optimized choice for current vWCPC flow and temperature settings. The current simulation can more realistically represent the $D$ p,kel for 7 nm vWCPC and also achieved good agreement with the 2 nm setting. Using the new simulation approach, we provide an optimized operation setting for the 7 nm setting. This study will guide further vWCPC performance optimization for applications requiring precise particle detection and atmospheric aerosol monitoring.

47 OTHER INSTRUMENTATION↗

Experimental and computational investigation of the bond energy of thorium dicarbonyl cation and theoretical elucidation of its isomerization mechanism to the thermodynamically most stable isomer, thorium oxide ketenylidene cation, OTh + CCO

Collision-induced dissociation (CID) of [Th,2C,2O] + with Xe is performed using a guided ion beam tandem mass spectrometer (GIBMS). The only products observed are ThCO + and Th + by sequential loss of CO ligands. The experimental findings and theoretical calculations support that the structure of [Th,2C,2O] + is the bent homoleptic thorium dicarbonyl cation, Th + (CO) 2 , having quartet spin, which is both thermodynamically and kinetically stable enough in the gas phase to be observed in our GIBMS instrument. Analysis of the kinetic energy-dependent cross sections for this CID reaction yields the first experimental determination of the bond dissociation energy (BDE) of (CO)Th + –CO at 0 K as 1.05 ± 0.09 eV. A theoretical BDE calculated at the CCSD(T) level with cc-pVXZ (X = T and Q) basis sets and a complete basis set (CBS) extrapolation is in very good agreement with the experimental result. Although the doublet spin bent thorium oxide ketenylidene cation, OTh + CCO, is calculated to be the most thermodynamically stable structure, it is not observed in our experiment where [Th,2C,2O] + is formed by association of Th + and CO in a direct current discharge flow tube (DC/FT) ion source. Potential energy profiles of both quartet and doublet spin are constructed to elucidate the isomerization mechanism of Th + (CO) 2 to OTh + CCO. The failure to observe OTh + CCO is attributed to a barrier associated with C–C bond formation, which makes OTh + CCO kinetically inaccessible under our experimental conditions. Furthermore, chemical bonding patterns in low-lying states of linear and bent Th + (CO) 2 and OTh + CCO isomers are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Safety [Vol. 35, No. 2, July-December 1994]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 179 Consideration of Postaccident Consequences in the Determination of Safety Objectives for Future Nuclear Power Plants in France, D. Queniart, A. Sugier, and J. Lochard; ACCIDENT ANALYSIS: 187 Nuclear Safety Research: The Phebus FP Severe Accident Experimental Program, P. von der Hardt, A. V. Jones, C. Lecomte, and A. Tattegrain; 205 Containment Performance Analysis of the Advanced Neutron Source Reactor at the Oak Ridge National Laboratory, S. H. Kim, R. P. Taleyarkhan, and V. Georgevich; 213 Assessment of Fission Product Deposits in the Reactor Coolant System: The DEVAP Program, G. Le Marois and M. Megnin; 222 Erratum to “A Review of the Available Information on the Triggering Stage of a Steam Explosion," Vol. 35, No. 1, CONTROL AND INSTRUMENTATION: 223 Effects of Normal Aging on Calibration and Response Time of Nuclear Plant Resistance Temperature Detectors and Pressure Sensors, H. M. Hashemian; DESIGN FEATURES: 235 Defense in Depth Against the Hydrogen Risk—A European Research Program, F. Fineschi; ENVIRONMENTAL EFFECTS: 246 Technical Note: A Preliminary Analysis of the Risks to Hong Kong Resulting from Potential Accidents of Daya Bay Nuclear Power Plant, Z. Shi and X. Wei; OPERATING EXPERIENCES: 253 Reactor Shutdown Experience, Compiled by J. W. Cletcher; SPECIAL SECTION ON TMI-2 VESSEL INVESTIGATION PROJECT: 256 Three Mile Island—New Findings 15 Years After the Accident A. M. Rubin and E. Beckjord; 269 Relocation of Molten Material to the TMI-2 Lower Head, J. R. Wolf, D. W. Akers, and L. A. Neimark; 280 Insight Into the TMI-2 Core Material Relocation Through Examination of Instrument Tube Nozzles, L. A. Neimark; 288 Physical and Radiochemical Examinations of Debris from the TMI-2 Lower Head, D. W. Akers and B. K. Schuetz; 301 Results of Metallographic Examinations and Mechanical Tests of Pressure Vessel Samples from the TMI-2 Lower Head, D. R. Diercks and G. E. Korth; 313 Margin-to-Failure Calculations for the TMI-2 Vessel, J. Rempe, L. Stickler, S. Chavez, G. Thinnes, R. Witt, and M. Corradini; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 328 1993 Accident Sequence Precursor (ASP) Program Results, L. N. Vanden Heuvel, J. W. Cletcher, D. A. Copinger, J. W. Minarick, B. W. Dolan, and P. D. O’Reilley; RECENT DEVELOPMENTS: 339 Reports, Standards, and Safety Guides, D. S. Queener; 345 Proposed Rule Changes as of June 30, 1994; ANNOUNCEMENTS: 234 Thirty-First Annual Meeting of the National Council on Radiation Protection and Measurements; 356 1995 International Incineration Conference; 358 Fifth International Controls and Instrumentation Conference; 359 ANS International Topical Meeting on Safety of Operating Reactors; 359 Fifth International Conference on Nuclear Criticality Safety; 360 International Conference on Probabilistic Safety Assessment Methodology and Applications; 351 The Authors; 357 Reviewers of Nuclear Safety, Vol. 35.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of the exothermicity of the chemi-ionization reaction Sm + O → SmO{sup +} + e{sup −}

The exothermicity of the chemi-ionization reaction Sm + O → SmO{sup +} + e{sup −} has been re-evaluated through the combination of several experimental methods. The thermal reactivity (300–650 K) of Sm{sup +} and SmO{sup +} with a range of species measured using a selected ion flow tube-mass spectrometer apparatus is reported and provides limits for the bond strength of SmO{sup +}, 5.661 eV ≤ D{sub 0}(Sm{sup +}-O) ≤ 6.500 eV. A more precise value is measured to be 5.72{sub 5} ± 0.07 eV, bracketed by the observed reactivity of Sm{sup +} and SmO{sup +} with several species using a guided ion beam tandem mass spectrometer (GIBMS). Combined with the established Sm ionization energy (IE), this value indicates an exothermicity of the title reaction of 0.08 ± 0.07 eV, ∼0.2 eV smaller than previous determinations. In addition, the ionization energy of SmO has been measured by resonantly enhanced two-photon ionization and pulsed-field ionization zero kinetic energy photoelectron spectroscopy to be 5.7427 ± 0.0006 eV, significantly higher than the literature value. Combined with literature bond energies of SmO, this value indicates an exothermicity of the title reaction of 0.14 ± 0.17 eV, independent from and in agreement with the GIBMS result presented here. The evaluated thermochemistry also suggests that D{sub 0}(SmO) = 5.83 ± 0.07 eV, consistent with but more precise than the literature values. Implications of these results for interpretation of chemical release experiments in the thermosphere are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Conceptual Design of a Test Section for a Cryogenic Transfer Line Experiment

This project presents the development of a comprehensive computer-aided design (CAD) model for the Transfer Line test section, which is an upcoming test module for the Flow Boiling and Condensation Experiment (FBCE) aboard the International Space Station. The FBCE aims to serve as the primary platform to study two-phase flow in microgravity, and the Transfer Line module aims to utilize its existing hardware to study cryogenic chilldown; a critical component of cryogenic propellant transfer in space. The CAD model was created using SolidWorks software and includes the test section’s main components: a heat transfer line, a flow visualization line, insulation, high-speed visible imaging, and infrared imaging. The heat transfer line primarily consists of a stainless steel tube that will be heated via Joule heating. The flow visualization line consists of segmented Indium-Titanium-Oxide coated sapphire tubes, which allow for visualization of flow regimes by high-speed and infrared cameras, similar thermal properties as the stainless steel tube, and Joule heating via the ITO coating resistance. Polyether Ether Ketone was used to insulate and encapsulate the two sections. High-speed visible imaging and infrared imaging were also incorporated to view the propagation of fluid during inverted annular flow and map out the thermal profile of the ITO-coated sapphire tube. This model serves as the guiding concept design for the Transfer Line project and will assist the project team during future safety reviews and concept design reviews. Overall, this work is significant in two-phase flow research and offers a promising path towards an established facility for cryogenic transfer line research in microgravity.

Flow boiling↗