Search NASA⌕ Search

SEARCH · Search NASA

Results for “Experiment Guide Tube”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental and theoretical investigation of the self-reaction of phenyl radicals.

A combination of experiment and theory is applied to the self-reaction kinetics of phenyl radicals. The dissociation of phenyl iodide is observed with both time-of-flight mass spectrometry, TOF-MS, and laser schlieren, LS, diagnostics coupled to a diaphragmless shock tube for temperatures ranging from 1276 to 1853 K. The LS experiments were performed at pressures of 22 {+-} 2, 54 {+-} 7, and 122 {+-} 6 Torr, and the TOF-MS experiments were performed at pressures in the range 500-700 Torr. These observations are sensitive to both the dissociation of phenyl iodide and to the subsequent self-reaction of the phenyl radicals. The experimental observations indicate that both these reactions are more complicated than previously assumed. The phenyl iodide dissociation yields {approx}6% C{sub 6}H{sub 4} + HI in addition to the major and commonly assumed C{sub 6}H{sub 5} + I channel. The self-reaction of phenyl radicals does not proceed solely by recombination, but also through disproportionation to benzene + o-/m-/p-benzynes, with comparable rate coefficients for both. The various channels in the self-reaction of phenyl radicals are studied with ab initio transition state theory based master equation calculations. These calculations elucidate the complex nature of the C{sub 6}H{sub 5} self-reaction and are consistent with the experimental observations. The theoretical predictions are used as a guide in the development of a model for the phenyl iodide pyrolysis that accurately reproduces the observed laser schlieren profiles over the full range of the observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The KATRIN superconducting magnets: Overview and first performance results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

47 OTHER INSTRUMENTATION↗

A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Small-Scale Drying: FY2020 Interim Report

This report documents the interim experimental status of small-scale drying tests currently being performed at Pacific Northwest National Laboratory. These small-scale drying tests are to develop the technical bases for sensors, techniques, and approaches that will be used to address the challenges faced when determining moisture content from gas samples taken at the North Anna Nuclear Generating Station for the High Burnup Demonstration Project. Specifically, the purpose of these tests is to support Sandia National Laboratories gas sample methods and analyses through a series of small-scale experiments. Key focus areas include performing tests to: • Correlate sample bottle measurements to in-cask conditions • Estimate the amount of trapped and absorbed water on cask features and surfaces that can contribute to water vapor • Assess the accuracy of the hygrometer used in the measurements under similar conditions • Identify additional methods for measuring humidity in casks easily and accurately using lessons-learned from Sandia National Laboratories, including direct gravimetric and isotopic tracer techniques. To address these topics this report outlines a series of five tests and any data collected to date that were planned for FY 2020 that include 1) humidity measurement method development, 2) gas bottle sampling tests, 3) surface drying tests on cladding, 4) small-scale drying of cladding, and 5) small-scale drying of guide-tube/dashpots. This interim report documents the experimental background, design and progress of these small-scale drying tests. Further data gathered will be summarized in the FY 2021 report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanical failure of fresh nuclear grade iron–chromium–aluminum (FeCrAl) cladding under simulated hot zero power reactivity initiated accident conditions

The reactivity initiated accident (RIA) is a postulated accident in light water reactors initiated by a rapid increase in reactivity which causes an increase in fission rate and fuel temperature. One potential mode of fuel system failure during RIA is pellet cladding mechanical interaction (PCMI) due to the rapid thermal expansion of the fuel pellet. Simulated PCMI experiments were performed by rapidly pressurizing iron-chromium-aluminum (FeCrAl) cladding tube samples using a hydraulic modified burst test system, causing the specimens to burst under a biaxial loading path. Deformation and rupture of the specimens were tracked with a telecentric lens and high-speed camera system. Outer surface strains were calculated using digital image correlation (DIC) on speckle patterns painted on the specimens’ outer surfaces. Experiments were conducted at approximately 275 °C, representative of hot zero power RIA conditions. The failure hoop strain was DIC-calculated between approximately 1.8–3.4%, corresponding to quasi-static energy depositions of approximately 110–260 calories per gram UO 2 assuming initial pellet-cladding contact. These conditions are very similar to the proposed energy deposition limit of 150 calories per gram UO 2 for unirradiated zirconium-based cladding in US Nuclear Regulatory Commission (NRC) Draft Regulatory Guide 1327. A very small strain rate dependence was observed in the data, with the magnitude of the failure hoop strain decreasing slightly with increasing strain rate. This observed dependence may be relevant because the FeCrAl cladding strain rate will be approximately 20% higher than in zirconium-based cladding due to the harder neutron spectrum and resultant shorter neutron generation time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of the Electromagnetic Particle Injector (EPI) for Tokamak Deployment

Both predicting and controlling disruptions are critical and urgent issues for ITER as some disruptions with a short warning time may be unavoidable. For these cases, a rapid response disruption mitigation system (DMS) referred to as the electromagnetic particle injector (EPI) is being developed. The primary advantages of the EPI are its fast response time and high velocity, which have been demonstrated in offline experiments (Raman et al., 2021). The EPI is capable of accelerating a metallic sabot electromagnetically using a rail gun to the required velocities ( > 2 km/s) within 2 ms. Two high-field racetrack magnets able to generate fields over 2 T are positioned above and below the rails to permit high velocity at low rail currents, a requirement to minimize electrode erosion. At the end of the acceleration phase, a sabot capture mechanism retains the spent sabot inside the vacuum chamber that houses the EPI. At this point, it releases well-defined microspheres, or a shell pellet, of a radiative payload into the disrupting plasma. A remotely operated sabot loading system positioned behind the injector contains several pre-equipped sabots that can be loaded by an operator from the tokamak control room. The injector is interfaced to the tokamak through a guide tube attached to the front of the EPI vacuum chamber. Finally, the advantages of the EPI system over other DMSs under consideration are described in conjunction with the details of an EPI system designed for near-term test on an existing large tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Method to Design and Optimize Axial Flow Cyclones for Gas–Liquid Separation

This article provides a detailed design guide, optimization, and performance assessment for air–water separation of an axial flow cyclone. Axial flow cyclones (also known as swirl tube demisters, mist eliminators, or Austin–Write cyclones) have a range of applications in several different industries. This method of gas–liquid separation offers many benefits. Among these are high liquid separation efficiencies (near 99%) and an inline design that allows them to be more easily fitted into existing piping structures. Despite these benefits, there are several design parameters that have not been optimized for performance in wastewater purification applications. This research fills the gap in the literature by quantifying the effect of new design parameters on water collection efficiency, η water collection , and the air bypass efficiency, η air bypass , defined as the ratio of the air mass flowrate exiting through the desired air outlet over the inlet air mass flowrate. A set of wide-ranging experiments were conducted to study the effects of gas–liquid flow rates, tube geometry, and relative injection angles to optimize the water collection and air bypass efficiencies. The water collection efficiency exceeded 99.8% when the liquid streamline came in direct contact with the water drainage exit. An empirical correlation was developed to predict the swirl pitch as a function of the above design parameters. Predictions from the correlation were within 10% of the experimental results. The correlation can be used to design highly efficient in-line gas–liquid separators.

Engineering↗

Flexible radioluminescence imaging for FDG-guided surgery

Purpose: Flexible radioluminescence imaging (Flex-RLI) is an optical method for imaging {sup 18}F-fluorodeoxyglucose (FDG)-avid tumors. The authors hypothesize that a gadolinium oxysulfide: terbium (GOS:Tb) flexible scintillator, which loosely conforms to the body contour, can enhance tumor signal-to-background ratio (SBR) compared with RLI, which utilizes a flat scintillator. The purpose of this paper is to characterize flex-RLI with respect to alternative modalities including RLI, beta-RLI (RLI with gamma rejection), and Cerenkov luminescence imaging (CLI). Methods: The photon sensitivity, spatial resolution, and signal linearity of flex-RLI were characterized with in vitro phantoms. In vivo experiments utilizing 13 nude mice inoculated with the head and neck (UMSCC1-Luc) cell line were then conducted in accordance with the institutional Administrative Panel on Laboratory Animal Care. After intravenous injection of {sup 18}F-FDG, the tumor SBR values for flex-RLI were compared to those for RLI, beta-RLI, and CLI using the Wilcoxon signed rank test. Results: With respect to photon sensitivity, RLI, beta-RLI, and flex-RLI produced 1216.2, 407.0, and 98.6 times more radiance per second than CLI. Respective full-width half maximum values across a 0.5 mm capillary tube were 6.9, 6.4, 2.2, and 1.5 mm, respectively. Flex-RLI demonstrated a near perfect correlation with {sup 18}F activity (r = 0.99). Signal uniformity for flex-RLI improved after more aggressive homogenization of the GOS powder with the silicone elastomer during formulation. In vivo, the SBR value for flex-RLI (median 1.29; interquartile range 1.18–1.36) was statistically greater than that for RLI (1.08; 1.02–1.14; p < 0.01) by 26%. However, there was no statistically significant difference in SBR values between flex-RLI and beta-RLI (p = 0.92). Furthermore, there was no statistically significant difference in SBR values between flex-RLI and CLI (p = 0.11) in a more limited dataset. Conclusions: Flex-RLI provides high quality images with SBRs comparable to those from CLI and beta-RLI in a single 10 s acquisition.

60 APPLIED LIFE SCIENCES↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping the performance of a versatile water-based condensation particle counter (vWCPC) with numerical simulation and experimental study

Accurate airborne aerosol instrumentation is required to determine the spatial distribution of ambient aerosol particles, particularly when dealing with the complex vertical profiles and horizontal variations of atmospheric aerosols. A versatile water-based condensation particle counter (vWCPC) has been developed to provide aerosol concentration measurements under various environments with the advantage of reducing the health and safety concerns associated with using butanol or other chemicals as the working fluid. However, the airborne deployment of vWCPCs is relatively limited due to the lack of characterization of vWCPC performance at reduced pressures. Given the complex combinations of operating parameters in vWCPCs, modeling studies have advantages in mapping vWCPC performance. In this work, we thoroughly investigated the performance of a laminar-flow vWCPC using COMSOL Multiphysics® simulation coupled with MATLAB™. We compared it against a modified vWCPC (vWCPC model 3789, TSI, Shoreview, MN, USA). Our simulation determined the performance of particle activation and droplet growth in the vWCPC growth tube, including the supersaturation, $D$ p,kel,0 (smallest size of particle that can be activated), $D$ p,kel,50 (particle size activated with 50 % efficiency) profile, and final growth particle size D d under wide operating temperatures, inlet pressures $P$ (30–101 kPa), and growth tube geometry (diameter $D$ and initiator length $L$ ini ). The effect of inlet pressure and conditioner temperature on vWCPC 3789 performance was also examined and compared with laboratory experiments. The COMSOL simulation result showed that increasing the temperature difference (Δ$T$) between conditioner temperature $T$ con and initiator $T$ ini will reduce $D$ p,kel,0 and the cut-off size $D$ p,kel,50 of the vWCPC. In addition, lowering the temperature midpoint ($T$ mid = $\frac{T_{con}+T_{ini}}{2}$ increases the supersaturation and slightly decreases the $D$ p,kel . The droplet size at the end of the growth tube is not significantly dependent on raising or lowering the temperature midpoint but significantly decreases at reduced inlet pressure, which indirectly alters the vWCPC empirical cut-off size. Our study shows that the current simulated growth tube geometry ($D$=6.3 mm and $L$ ini =30 mm) is an optimized choice for current vWCPC flow and temperature settings. The current simulation can more realistically represent the $D$ p,kel for 7 nm vWCPC and also achieved good agreement with the 2 nm setting. Using the new simulation approach, we provide an optimized operation setting for the 7 nm setting. This study will guide further vWCPC performance optimization for applications requiring precise particle detection and atmospheric aerosol monitoring.

47 OTHER INSTRUMENTATION↗

Experimental and computational investigation of the bond energy of thorium dicarbonyl cation and theoretical elucidation of its isomerization mechanism to the thermodynamically most stable isomer, thorium oxide ketenylidene cation, OTh + CCO

Collision-induced dissociation (CID) of [Th,2C,2O] + with Xe is performed using a guided ion beam tandem mass spectrometer (GIBMS). The only products observed are ThCO + and Th + by sequential loss of CO ligands. The experimental findings and theoretical calculations support that the structure of [Th,2C,2O] + is the bent homoleptic thorium dicarbonyl cation, Th + (CO) 2 , having quartet spin, which is both thermodynamically and kinetically stable enough in the gas phase to be observed in our GIBMS instrument. Analysis of the kinetic energy-dependent cross sections for this CID reaction yields the first experimental determination of the bond dissociation energy (BDE) of (CO)Th + –CO at 0 K as 1.05 ± 0.09 eV. A theoretical BDE calculated at the CCSD(T) level with cc-pVXZ (X = T and Q) basis sets and a complete basis set (CBS) extrapolation is in very good agreement with the experimental result. Although the doublet spin bent thorium oxide ketenylidene cation, OTh + CCO, is calculated to be the most thermodynamically stable structure, it is not observed in our experiment where [Th,2C,2O] + is formed by association of Th + and CO in a direct current discharge flow tube (DC/FT) ion source. Potential energy profiles of both quartet and doublet spin are constructed to elucidate the isomerization mechanism of Th + (CO) 2 to OTh + CCO. The failure to observe OTh + CCO is attributed to a barrier associated with C–C bond formation, which makes OTh + CCO kinetically inaccessible under our experimental conditions. Furthermore, chemical bonding patterns in low-lying states of linear and bent Th + (CO) 2 and OTh + CCO isomers are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Safety [Vol. 35, No. 2, July-December 1994]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 179 Consideration of Postaccident Consequences in the Determination of Safety Objectives for Future Nuclear Power Plants in France, D. Queniart, A. Sugier, and J. Lochard; ACCIDENT ANALYSIS: 187 Nuclear Safety Research: The Phebus FP Severe Accident Experimental Program, P. von der Hardt, A. V. Jones, C. Lecomte, and A. Tattegrain; 205 Containment Performance Analysis of the Advanced Neutron Source Reactor at the Oak Ridge National Laboratory, S. H. Kim, R. P. Taleyarkhan, and V. Georgevich; 213 Assessment of Fission Product Deposits in the Reactor Coolant System: The DEVAP Program, G. Le Marois and M. Megnin; 222 Erratum to “A Review of the Available Information on the Triggering Stage of a Steam Explosion," Vol. 35, No. 1, CONTROL AND INSTRUMENTATION: 223 Effects of Normal Aging on Calibration and Response Time of Nuclear Plant Resistance Temperature Detectors and Pressure Sensors, H. M. Hashemian; DESIGN FEATURES: 235 Defense in Depth Against the Hydrogen Risk—A European Research Program, F. Fineschi; ENVIRONMENTAL EFFECTS: 246 Technical Note: A Preliminary Analysis of the Risks to Hong Kong Resulting from Potential Accidents of Daya Bay Nuclear Power Plant, Z. Shi and X. Wei; OPERATING EXPERIENCES: 253 Reactor Shutdown Experience, Compiled by J. W. Cletcher; SPECIAL SECTION ON TMI-2 VESSEL INVESTIGATION PROJECT: 256 Three Mile Island—New Findings 15 Years After the Accident A. M. Rubin and E. Beckjord; 269 Relocation of Molten Material to the TMI-2 Lower Head, J. R. Wolf, D. W. Akers, and L. A. Neimark; 280 Insight Into the TMI-2 Core Material Relocation Through Examination of Instrument Tube Nozzles, L. A. Neimark; 288 Physical and Radiochemical Examinations of Debris from the TMI-2 Lower Head, D. W. Akers and B. K. Schuetz; 301 Results of Metallographic Examinations and Mechanical Tests of Pressure Vessel Samples from the TMI-2 Lower Head, D. R. Diercks and G. E. Korth; 313 Margin-to-Failure Calculations for the TMI-2 Vessel, J. Rempe, L. Stickler, S. Chavez, G. Thinnes, R. Witt, and M. Corradini; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 328 1993 Accident Sequence Precursor (ASP) Program Results, L. N. Vanden Heuvel, J. W. Cletcher, D. A. Copinger, J. W. Minarick, B. W. Dolan, and P. D. O’Reilley; RECENT DEVELOPMENTS: 339 Reports, Standards, and Safety Guides, D. S. Queener; 345 Proposed Rule Changes as of June 30, 1994; ANNOUNCEMENTS: 234 Thirty-First Annual Meeting of the National Council on Radiation Protection and Measurements; 356 1995 International Incineration Conference; 358 Fifth International Controls and Instrumentation Conference; 359 ANS International Topical Meeting on Safety of Operating Reactors; 359 Fifth International Conference on Nuclear Criticality Safety; 360 International Conference on Probabilistic Safety Assessment Methodology and Applications; 351 The Authors; 357 Reviewers of Nuclear Safety, Vol. 35.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of the exothermicity of the chemi-ionization reaction Sm + O → SmO{sup +} + e{sup −}

The exothermicity of the chemi-ionization reaction Sm + O → SmO{sup +} + e{sup −} has been re-evaluated through the combination of several experimental methods. The thermal reactivity (300–650 K) of Sm{sup +} and SmO{sup +} with a range of species measured using a selected ion flow tube-mass spectrometer apparatus is reported and provides limits for the bond strength of SmO{sup +}, 5.661 eV ≤ D{sub 0}(Sm{sup +}-O) ≤ 6.500 eV. A more precise value is measured to be 5.72{sub 5} ± 0.07 eV, bracketed by the observed reactivity of Sm{sup +} and SmO{sup +} with several species using a guided ion beam tandem mass spectrometer (GIBMS). Combined with the established Sm ionization energy (IE), this value indicates an exothermicity of the title reaction of 0.08 ± 0.07 eV, ∼0.2 eV smaller than previous determinations. In addition, the ionization energy of SmO has been measured by resonantly enhanced two-photon ionization and pulsed-field ionization zero kinetic energy photoelectron spectroscopy to be 5.7427 ± 0.0006 eV, significantly higher than the literature value. Combined with literature bond energies of SmO, this value indicates an exothermicity of the title reaction of 0.14 ± 0.17 eV, independent from and in agreement with the GIBMS result presented here. The evaluated thermochemistry also suggests that D{sub 0}(SmO) = 5.83 ± 0.07 eV, consistent with but more precise than the literature values. Implications of these results for interpretation of chemical release experiments in the thermosphere are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Which G-Tube to Use in Pullers: Assessment of Pull Pressures on Skin Models to Determine Optimal Catheter Choice in Patients with Recurrent Pulled Gastrostomy Tubes

Introduction: Pulled or dislodged gastrostomy catheters represent a common complication associated with percutaneous gastrostomy and are a common cause of recurrent visits in patients with altered mental status. We intended to perform an experiment to compare the pull forces required to dislodge different commonly used gastrostomy catheters. Materials and Methods: We used a digital force gauge device to measure the pull forces required to dislodge three types of 20 French gastrostomy catheters in double-layer skin models. These included the Flow 20 Pull Method (Cook Medical, Bloomington, IN, USA), Entuit Gastrostomy BR Balloon Retention feeding tube (Cook Medical, Bloomington, IN, USA), and Ponsky Non-Balloon Replacement Gastrostomy Tube (CR Bard Inc, Salt Lake City, Utah, USA). The catheters were inserted into the skin model using the same technique as would be utilized in a patient. Results: The mean forces measured to dislodge the per-oral Flow 20 Pull Method, Entuit Thrive Balloon Retention, and button-type retention Ponsky replacement catheters were 35.6, 22.8, and 20.6 Newtons, respectively. The pull method per-oral gastrostomy catheter required significantly more pull force to dislodge than both the Ponsky button-type retention catheter and the Entuit balloon retention catheters. There was no significant difference in the pull force required to dislodge the Ponsky replacement catheter and the Entuit balloon retention catheter. Conclusions: Per-oral image-guided gastrostomy with pull-method button-type retention catheters may be the ideal choice in patients at high risk of tube dislodgment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron Bernstein Wave Studies in MST

The overdense plasma in an RFP prevents electromagnetic waves from propagating past the edge, however use of the electron Bernstein wave (EBW) has the potential to heat and drive current in the plasma. MHD simulations have demonstrated that resistive tearing mode stability is very sensitive to gradients in the edge current density profile allowing EBW to potentially be a stabilizing influence. A new MW level experiment is being commissioned on MST to evaluate the potential use of the EBW for current profile control on the RFP. The development of new equipment includes a 5.5 GHz klystron driven by a novel switchmode power supply. A quartz window has been constructed and coupling with a cylindrical molybdenum wave guide antenna has been studied. Due to the steep edge density gradient in the RFP, it is possible to efficiently couple to the EBW with O or X mode launch. The EBW is strongly damped at the electron cyclotron resonance where it couples to the electron gyromotion and alters the electron distribution. Either Fisch-Boozer or Ohkawa current drive mechanisms can be activated to drive off axis current in the plasma. Preliminary experiments have been performed to verify high power coupling and understand heating via observed x-ray emission when compared to Fokker-Plank modeling in CQL3D.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗