Search NASA⌕ Search

SEARCH · Search NASA

Results for “FIRST ROBOTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

LaserSnake2: Remote High Powered Laser Cutting in Confined Hazardous Spaces - 16161

LaserSnake2, a UK collaborative project, seeks to deliver remotely operated cutting techniques into high hazard nuclear environments. This paper describes the developments and results of combining proven robotic manipulators with high-powered laser cutting tools, to allow for selective dismantling within complex nuclear process cells. Decommissioning old and poorly catalogued nuclear plant is a problem faced the world over. Designed with little consideration for decommissioning, or adapted significantly from the original drawings, legacy plant and infrastructure is full of spaces where it is undesirable or impossible to send people. Typically, a process cell or cave will require modification to ensure suitability for human entry or deployment of heavy duty equipment to complete the decontamination processes. The process of widening access routes, or selectively moving sections of highly contaminated material, is ideally suited to remote handling technology. The results of TWI's research into fibre-delivered laser cutting techniques, and integration with a dexterous snake-arm robot, are presented. Coupled with novel laser process head design and diffractive optical elements, the result is an integrated system capable of cutting up to 100 mm thick C-Mn steel plate at significant stand-off distances, encompassing the range of infrastructure found in a typical nuclear plant. Two options have been considered for deployment of the laser cutting tool. The first is focused on a fixed installation using a standard industrial robot. The second is a large, highly flexible snake-arm robot capable of entering cluttered cells through existing penetrations. Designed to operate through a standard 11'' MSM port, the 4.5 m snake-arm robot has the capacity to carry grippers, sensors or the laser cutting tool at the tip. The snake-arm is sealed and housed within a glove box for contamination control, allowing operation within a radioactive environment. Significant technical developments and material research are presented which have led to improved operational life, payload and bend. This paper describes the series of inactive trials which have been conducted to demonstrate the LaserSnake2 system's capabilities. These include: horizontal and vertical deployment, underwater operation, object manipulation and laser cutting. With global nuclear decommissioning costs running in to the $trillions, safe and cost efficient tools such as the LaserSnake2 system are essential as part of the decommissioning toolbox. Remote handling can account for up to 20% of a decommissioning project's costs, however significant time and financial savings can be made by utilising this new technology to reduce operator exposure and reach previously inaccessible areas. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Start-up of Silo 130 Waste Retrieval at La Hague: first Step Towards Reducing Legacy Inventory - 20020

On June 25, 2019, the first grapple of waste and debris was lifted from Silo 130, one of the most challenging legacy waste storage silos at La Hague. This was the achievement of more than ten years of studies and efforts focused on solving some very unique technical and safety challenges, and on designing an innovative, efficient solution. The waste is from de-cladding materials from past Gas-Cooled Reactor fuel reprocessing operations. It is an unsorted mixture of magnesium cladding pieces, graphite debris, and various other metallic waste types. These materials can be chemically reactive and therefore need specific dispositions for handling and storing. The building is more than 40 years old and does not meet modern standards. French safety authorities have required the silo to be emptied. After about three years of operation, the bulk of this waste will be removed and placed in safe storage, pending the selection of a final conditioning solution. Removal of bottom debris will then be possible. When finished, this operation will bring a conclusion to a significant legacy-related hazard on the site. The silo will then be available for final cleaning and de-activation. This paper will describe the technical, safety, and economical challenges, and the various decisions and optimizations that led to the definition of the process and technology to be implemented. Several innovative features were developed and implemented, in all sections of the project: project organization, progressive approach for the waste disposition strategy, light building design, customized and robust retrieval technology, processing technologies involving the most modern robotic and sorting techniques, storage method... Several of these first-of-a-kind innovative features have been developed and qualified specifically for this application, using the detailed qualification procedure specified for all La Hague projects. The facility was built in less than five years, overcoming various difficulties along the line. Commissioning is now finished with the combined efforts of the project, engineering, start-up, and operating teams assisted by dedicated suppliers. The facility is now ramping-up. The paper will also report on the commissioning and start-up of the facility and describe the first operational results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation robot on cables - 15250

The Decontamination and Decommissioning (D and D) Operations take place in hostile environments to the human intervention. In this context, robotic systems are a solution to achieve these operations while minimizing human intervention. Among these operations, the monitoring of lengthwise plant has to be performed in places where the radioactive contaminations make hostile environments. These monitoring operations need to measure several physics parameters in several locations in a precise and safe manner. These repetitive tasks can be made by robots that are simple, small sized and easily adaptable. In this scope, a robotic system on cables has been designed to control and monitor the inside of lengthwise nuclear facilities. In lengthwise installations, the using of cables allows to increase the covered zone of the robots which is an essential quality in such places. Unlike cable-driven parallel robots used in workspaces of 2D or 3D controlled by redundant tensioning motors, the current robot moves in a 1D workspace. Thus a tractors cable controlled by one tensioning motor is used to drive the robot on carrier cables. In this paper, we will describe the first results of this work by bringing out the innovation of our system. Then, we will discuss the perspective to upgrade the actual system whose applications could be perfectly imagined outside the nuclear D and D industry. (authors)

42 ENGINEERING↗

Mine Rescue Robotics: Gemini-Scout - 18507

Gemini Scout is a mine rescue vehicle developed by Sandia National Laboratories to help locate and communicate with trapped miners following an accident. In a mining accident, first responders are working against a myriad of dangers to assess the situation and rescue trapped miners. The robot can enter potentially dangerous situations ahead of rescuers to evaluate hazardous environments and help them determine how operations should proceed. The Gemini Scout mitigates many of the potential dangers and allows exploration and assessment without further endangering individuals. The robotic vehicle can operate in hostile, debris strewn, dark, muddy, high temperature, and explosive environments. It has extreme ground mobility including operation in up to 18 inches of water and ability to traverse large rubble piles and cross railroad tracks. The vehicle provides gas and temperature sensing as well as pan, tilt, zoom color and thermal camera video streaming back to an operator in a safe zone. The extreme mobility of the vehicle and the modularity of the platform allowing easy integration of sensors are directly applicable to many needs within Waste Management. The development of Gemini Scout was funded by National Institute of Occupational Safety and Health (NIOSH) and the primary customer and certification entity was Mine Safety and Health Administration (MSHA). Lessons-learned during development and steps leading to certification are also applicable to the development of systems for unique Waste Management sites. (authors)

42 ENGINEERING↗

GEMINI Case Study

Sandia's GEMINI-Scout Mine Rescue Robot is an unmanned ground vehicle designed to enter potentially hazardous environments to explore, assess, and evaluate dangerous situations first responders may face when conducting a rescue mission. GEMINI is approximately four feet long and two feet tall, which enables the robot to maneuver through small locations on rough terrains caused by earthquakes, fires, or radiological incidents. GEMINI uses track propulsion to climb stairs, travel through gravel and sand pits, pivot in place, and traverse 45-degree climbs with few problems. Furthermore, the vehicle's dual tracked-chassis design allows it to operate in hostile, dark, muddy, high-temperature, and explosive debris-strewn environments, while maintaining efficient ground mobility. The mobility and modularity of the vehicle allow for easy integration of sensors to conduct gas and temperature sensing and offers pan/tilt, zoom color, and thermal camera video streaming capabilities. The vehicle is also able to carry a payload of about 50 pounds of batteries and can handle an additional 200 pounds of payload, whether for additional diagnostics, supplies, or clothing for those trapped in an effected area. GEMINI is remotely operated through a wireless connection and an onboard computer running a customized embedded control application, which directly communicates to all onboard components except for the audio and video systems. When line of sight is not possible, operators use a shockresistant fiber optic cable to ensure continuous functionality of the vehicle. This allows for direct local control of the vehicle, which streams collected data back to the operator for enhanced situational awareness. In addition, the vehicle incorporates safety features such as explosion proof housing to ensure safe electronic operations in hazardous gas or flooded environments; a four-channel video link and two-way audio to ensure located survivors can communicate with operators; and an MSHA-approved multi-gas sensor to monitor air quality.

42 ENGINEERING↗

Telerobotic system concept for real-time soft-tissue imaging during radiotherapy beam delivery

Purpose: The curative potential of external beam radiation therapy is critically dependent on having the ability to accurately aim radiation beams at intended targets while avoiding surrounding healthy tissues. However, existing technologies are incapable of real-time, volumetric, soft-tissue imaging during radiation beam delivery, when accurate target tracking is most critical. The authors address this challenge in the development and evaluation of a novel, minimally interfering, telerobotic ultrasound (U.S.) imaging system that can be integrated with existing medical linear accelerators (LINACs) for therapy guidance. Methods: A customized human-safe robotic manipulator was designed and built to control the pressure and pitch of an abdominal U.S. transducer while avoiding LINAC gantry collisions. A haptic device was integrated to remotely control the robotic manipulator motion and U.S. image acquisition outside the LINAC room. The ability of the system to continuously maintain high quality prostate images was evaluated in volunteers over extended time periods. Treatment feasibility was assessed by comparing a clinically deployed prostate treatment plan to an alternative plan in which beam directions were restricted to sectors that did not interfere with the transabdominal U.S. transducer. To demonstrate imaging capability concurrent with delivery, robot performance and U.S. target tracking in a phantom were tested with a 15 MV radiation beam active. Results: Remote image acquisition and maintenance of image quality with the haptic interface was successfully demonstrated over 10 min periods in representative treatment setups of volunteers. Furthermore, the robot's ability to maintain a constant probe force and desired pitch angle was unaffected by the LINAC beam. For a representative prostate patient, the dose-volume histogram (DVH) for a plan with restricted sectors remained virtually identical to the DVH of a clinically deployed plan. With reduced margins, as would be enabled by real-time imaging, gross tumor volume coverage was identical while notable reductions of bladder and rectal volumes exposed to large doses were possible. The quality of U.S. images obtained during beam operation was not appreciably degraded by radiofrequency interference and 2D tracking of a phantom object in U.S. images obtained with the beam on/off yielded no significant differences. Conclusions: Remotely controlled robotic U.S. imaging is feasible in the radiotherapy environment and for the first time may offer real-time volumetric soft-tissue guidance concurrent with radiotherapy delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

First detection of the BAO signal from early DESI data

We present the first detection of the baryon acoustic oscillations (BAOs) signal obtained using unblinded data collected during the initial 2 months of operations of the Stage-IV ground-based Dark Energy Spectroscopic Instrument (DESI). From a selected sample of 261 291 luminous red galaxies spanning the redshift interval 0.4 < z < 1.1 and covering 1651 square degrees with a 57.9 per cent completeness level, we report a ∼5σ level BAO detection and the measurement of the BAO location at a precision of 1.7 per cent. Using a bright galaxy sample of 109 523 galaxies in the redshift range 0.1 < z < 0.5, over 3677 square degrees with a 50.0 per cent completeness, we also detect the BAO feature at ∼3σ significance with a 2.6 per cent precision. These first BAO measurements represent an important milestone, acting as a quality control on the optimal performance of the complex robotically actuated, fibre-fed DESI spectrograph, as well as an early validation of the DESI spectroscopic pipeline and data management system. Based on these first promising results, we forecast that DESI is on target to achieve a high-significance BAO detection at sub-per cent precision with the completed 5-yr survey data, meeting the top-level science requirements on BAO measurements. This exquisite level of precision will set new standards in cosmology and confirm DESI as the most competitive BAO experiment for the remainder of this decade.

79 ASTRONOMY AND ASTROPHYSICS↗

A novel cell weighing method based on the minimum immobilization pressure for biological applications

A novel weighing method for cells with spherical and other regular shapes is proposed in this paper. In this method, the relationship between the cell mass and the minimum aspiration pressure to immobilize the cell (referred to as minimum immobilization pressure) is derived for the first time according to static theory. Based on this relationship, a robotic cell weighing process is established using a traditional micro-injection system. Experimental results on porcine oocytes demonstrate that the proposed method is able to weigh cells at an average speed of 16.3 s/cell and with a success rate of more than 90%. The derived cell mass and density are in accordance with those reported in other published results. The experimental results also demonstrated that this method is able to detect less than 1% variation of the porcine oocyte mass quantitatively. It can be conducted by a pair of traditional micropipettes and a commercial pneumatic micro-injection system, and is expected to perform robotic operation on batch cells. At present, the minimum resolution of the proposed method for measuring the cell mass can be 1.25 × 10{sup −15 }kg. Above advantages make it very appropriate for quantifying the amount of the materials injected into or moved out of the cells in the biological applications, such as nuclear enucleations and embryo microinjections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MASTER OPTICAL POLARIZATION VARIABILITY DETECTION IN THE MICROQUASAR V404 CYG/GS 2023+33

On 2015 June 15, the Swift space observatory discovered that the Galactic black hole candidate V404 Cyg was undergoing another active X-ray phase, after 25 years of inactivity. The 12 telescopes of the MASTER Global Robotic Net located at six sites across four continents were the first ground-based observatories to start optical monitoring of the microquasar after its gamma-ray wake up at 18{sup h} 34{sup m} 09{sup s} U.T. on 2015 June 15. In this paper, we report, for the first time, the discovery of variable optical linear polarization, changing by 4%–6% over a timescale of ∼1 hr, on two different epochs. We can conclude that the additional variable polarization arises from the relativistic jet generated by the black hole in V404 Cyg. The polarization variability correlates with optical brightness changes, increasing when the flux decreases.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-453: A Novel Daily QA System for Robotic Image Guided Radiosurgery with Variable Aperture Collimator

Purpose: A novel end-to-end system using a CCD camera and a scintillator based phantom that is capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery has been developed and reported in our previous work. This work investigates its application to end-to-end type daily QA for Robotic Radiosurgery (Cyberknife) with Variable Aperture Collimator (Iris). Methods: The phantom was first scanned with a CT scanner at 0.625 slice thickness and exported to the Cyberknife Muliplan (v4.6) treatment planning system. An isocentric treatment plan was created consisting of ten beams of 25 Monitor Units each using Iris apertures of 7.5, 10, 15, 20, and 25 mm. The plan was delivered six times in two days on the Cyberknife G4 system with fiducial tracking on the four metal fiducials embedded in phantom with re-positioning between the measurements. The beam vectors (X, Y, Z) are measured and compared with the plan from the machine delivery file (XML file). The Iris apertures (FWHM) were measured from the beam flux map and compared with the commissioning data. Results: The average beam positioning accuracies of the six deliveries are 0.71 ± 0.40 mm, 0.72 ± 0.44 mm, 0.74 ± 0.42 mm, 0.70 ± 0.40 mm, 0.79 ± 0.44 mm and 0.69 ± 0.41 mm respectively. Radiation beam width (FWHM) variations are within ±0.05 mm, and they agree with the commissioning data within 0.22 mm. The delivery time for the plan is about 7 minutes and the results are given instantly. Conclusion: The experimental results agree with stated sub-millimeter delivery accuracy of Cyberknife system. Beam FWHM variations comply with the 0.2 mm accuracy of the Iris collimator at SAD. The XRV-100 system has proven to be a powerful tool in performing end-to-end type tests for Robotic Image Guided Radiosurgery Daily QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-EF-BRB-08: Robotic Motion Compensation for Radiation Therapy: A 6DOF Phantom Study

Purpose: The high accuracy of frame-based stereotactic radiosurgery (SRS), which uses a rigid frame fixed to the patient’s skull, is offset by potential drawbacks of poor patient compliance and clinical workflow restrictions. Recent research into frameless SRS has so far resulted in reduced accuracy. In this study, we investigate the use of a novel 6 degree-of-freedom (6DOF) robotic head motion cancellation system that continuously detects and compensates for patient head motions during a SRS delivery. This approach has the potential to reduce invasiveness while still achieving accuracies better or equal to traditional frame-based SRS. Methods: A 6DOF parallel kinematics robotics stage was constructed, and controlled using an inverse kinematics-based motion compensation algorithm. A 6DOF stereoscopic infrared (IR) marker tracking system was used to monitor real-time motions at sub-millimeter and sub-degree levels. A novel 6DOF calibration technique was first applied to properly orient the camera coordinate frame to match that of the LINAC and robotic control frames. Simulated head motions were measured by the system, and the robotic stage responded to these 6DOF motions automatically, returning the reflective marker coordinate frame to its original position. Results: After the motions were introduced to the system in the phantom-based study, the robotic stage automatically and rapidly returned the phantom to LINAC isocenter. When errors exceeded the compensation lower threshold of 0.25 mm or 0.25 degrees, the system registered the 6DOF error and generated a cancellation trajectory. The system responded in less than 0.5 seconds and returned all axes to less than 0.1 mm and 0.1 degree after the 6DOF compensation was performed. Conclusion: The 6DOF real-time motion cancellation system was found to be effective at compensating for translational and rotational motions to current SRS requirements. This system can improve frameless SRS by automatically returning patients to isocenter with high 6DOF accuracy.

60 APPLIED LIFE SCIENCES↗

Tumor tracking and motion compensation with an adaptive tumor tracking system (ATTS): System description and prototype testing

A novel system for real-time tumor tracking and motion compensation with a robotic HexaPOD treatment couch is described. The approach is based on continuous tracking of the tumor motion in portal images without implanted fiducial markers, using the therapeutic megavoltage beam, and tracking of abdominal breathing motion with optical markers. Based on the two independently acquired data sets the table movements for motion compensation are calculated. The principle of operation of the entire prototype system is detailed first. In the second part the performance of the HexaPOD couch was investigated with a robotic four-dimensional-phantom capable of simulating real patient tumor trajectories in three-dimensional space. The performance and limitations of the HexaPOD table and the control system were characterized in terms of its dynamic behavior. The maximum speed and acceleration of the HexaPOD were 8 mm/s and 34.5 mm/s{sup 2} in the lateral direction, and 9.5 mm/s and 29.5 mm/s{sup 2} in longitudinal and anterior-posterior direction, respectively. Base line drifts of the mean tumor position of realistic lung tumor trajectories could be fully compensated. For continuous tumor tracking and motion compensation a reduction of tumor motion up to 68% of the original amplitude was achieved. In conclusion, this study demonstrated that it is technically feasible to compensate breathing induced tumor motion in the lung with the adaptive tumor tracking system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Rainbow Coverage Path Planning for a Patrolling Mobile Robot With Circular Sensing Range

In this paper, we proposed a coverage path (CP) planning approach for a mobile robot moving in a dynamically changing environment. Our family of algorithms begins by finding the first path around the center of interior obstacles/disks of a given target region (TR) through the Graham scan algorithm. The first path is then used as a foundational path to generate a collision free, first order differentiable, and observable CP through a complete set of input and output transformation algorithms which together form the rainbow CP planning approach. The last algorithm of the rainbow CP planning approach finds a sufficient number of observation points on the CP needed to observe the TR. The novelty of our rainbow CP planning approach is that it partitions the TR into different shapes with different properties needed to obtain complete coverage while achieving first order path differentiability. The main technical contributions of the proposed approach is to provide a holistic solution that segments any TR, uses triangulation to determine the line of sights and observation points, and computes the collision-free CP within a quadratic runtime. The proposed method can be readily generalized to address problems of higher dimensions, and it is scalable with respect to the size of TR and the number of robots. Computer simulations are used to illustrate the effectiveness and correctness of the proposed approach.

54 ENVIRONMENTAL SCIENCES↗

Commissioning and Operation of a Robotic Arm for Waste Retrieval at Trawsfynydd NPP, North Wales - 12091

Trawsfynydd is one of the UK's first generation Magnox nuclear power plants. It started operation in 1965 and ceased generation in 1991. Before the site can enter the 'care and maintenance' phase a number of wet and dry waste stores around the site must be emptied and their contents made safe. Wet wastes include sludges and resins produced during the operating life of the NPP. The sludges and resins are stored in a number of different tanks that vary significantly in terms of size, shape, internal features and access. A dexterous long reach manipulator arm has been designed and built to facilitate tank clearance. Commissioning of the arm was carried out in parallel with Factory Acceptance Testing (FAT) at the manufacturer's site in Colorado, USA. In addition to basic functional testing this work included a full range of task based testing to ensure that the arm, tools, control system and support equipment were thoroughly exercised in representative conditions. Trawsfynydd is one of the lead sites in the UK's program for nuclear plant decommissioning. As such the lessons learned, both in terms of technology and process, will be applicable across the remainder of the fleet. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reliability of EUCLIDIAN: An autonomous robotic system for image-guided prostate brachytherapy

Purpose: Recently, several robotic systems have been developed to perform accurate and consistent image-guided brachytherapy. Before introducing a new device into clinical operations, it is important to assess the reliability and mean time before failure (MTBF) of the system. In this article, the authors present the preclinical evaluation and analysis of the reliability and MTBF of an autonomous robotic system, which is developed for prostate seed implantation. Methods: The authors have considered three steps that are important in reliability growth analysis. These steps are: Identification and isolation of failures, classification of failures, and trend analysis. For any one-of-a-kind product, the reliability enhancement is accomplished through test-fix-test. The authors have used failure mode and effect analysis for collection and analysis of reliability data by identifying and categorizing the failure modes. Failures were classified according to severity. Failures that occurred during the operation of this robotic system were considered as nonhomogenous Poisson process. The failure occurrence trend was analyzed using Laplace test. For analyzing and predicting reliability growth, commonly used and widely accepted models, Duane's model and the Army Material Systems Analysis Activity, i.e., Crow's model, were applied. The MTBF was used as an important measure for assessing the system's reliability. Results: During preclinical testing, 3196 seeds (in 53 test cases) were deposited autonomously by the robot and 14 critical failures were encountered. The majority of the failures occurred during the first few cases. The distribution of failures followed Duane's postulation as well as Crow's postulation of reliability growth. The Laplace test index was -3.82 (<0), indicating a significant trend in failure data, and the failure intervals lengthened gradually. The continuous increase in the failure occurrence interval suggested a trend toward improved reliability. The MTBF was 592 seeds, which implied that several prostate seed implantation cases would be possible without encountering any critical failure. The shape parameter for the MTBF was 0.3859 (<1), suggesting a positive reliability growth of this robotic system. At 95% confidence, the reliability for deposition of 65 seeds was more than 90%. Conclusions: Analyses of failure mode strongly indicated a gradual improvement of reliability of this autonomous robotic system. High MTBF implied that several prostate seed implant cases would be possible without encountering any critical failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Comparisons for Artificially Propagated and Wild Pacific Lamprey Juveniles and Larvae

ABSTRACT Artificially propagated Pacific lamprey ( Entosphenus tridentatus ) are produced for restoration and for use in dam passage studies to reduce the demand for wild fish. Such uses require that animals are representative of their wild counterparts. Previous work indicated that this is true for Pacific lamprey larvae and juveniles reared in the hatchery with respect to the length of sustained swimming. However, more subtle differences in behaviour and performance that lamprey need to survive have not been assessed. In this study, artificially propagated and wild fish were compared in laboratory tests under no‐flow conditions to examine light avoidance, burrowing speed, burst swim speed, volitional routine swim speed and time to come to rest. Most larvae burrowed in less than a minute, and we found highly significant differences ( p < 0.001) between artificially propagated and wild larvae burrowing times, a critical escape behaviour. This could have implications for studies of larval entrainment at irrigation diversion canals or in turbine boils at dams. Interestingly, all of the wild juveniles tested came to rest quickly after introduction to the chamber (1.5 min), while artificially propagated lamprey swam robotically near the surface and 48% did not come to rest in the first 10 min (median time to rest = 9.5 min). In contrast, wild juveniles quickly (median = 1.47 min) sought areas near the tank bottom and attached strongly with their oral disc. Such behavioural differences could have important survival consequences for artificially propagated lamprey as they approach turbine intakes, bypass screens and irrigation diversion headgates. This study highlights the need to conduct behavioural assays that examine subtleties of fish behaviour that can be missed with traditional swim tunnel comparisons.

Frick, Kinsey [Fish Ecology Division, Northwest Fi↗

3-D Volumetric Gamma-ray Imaging and Source Localization with a Mobile Robot - 18124

Radiation detection has largely been a manual inspection process with point sensors such as Geiger-Muller counters and scintillation spectrometers to date. While their observations of source proximity prove useful, they lack the directional information necessary for efficient source localization and characterization in cluttered environments with multiple radiation sources. The recent commercialization of Compton gamma cameras provides directional information to the broader radiation detection community for the first time. This paper presents the integration of a Compton gamma camera with a self-localizing ground robot for accurate 3D radiation mapping. Using the position and orientation of the robot, radiation images from the gamma camera are accumulated over a traversed path in a shared frame of reference to construct a consistent voxel grid-based radiation map. The peaks of the map at pre-specified energy windows are selected as the source location estimates, which are compared to the ground truth source locations. The proposed approach localizes multiple sources to within an average of 0.2 m in two 5 x 4 m{sup 2} and 14 x 6 m{sup 2} laboratory environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Online Change of Activity in Energy Spectrum for Detection on an Early Intervention Robot

With the growth of industrial risks and the multiplication of CBRNe (Chemical Biological Radiological and explosive) attacks through toxic chemicals, biological or radiological threats, public services and military authorities face with increasingly critical situations, whose management is strongly conditioned by fast and reliable establishment of an informative diagnostic. Right after an attack, the five first minutes are crucial to define the various scenarios and the most dangerous for a human intervention. Therefore the use of robots is considered essential by all stakeholders of security. In this context, the SISPEO project (Systeme d'Intervention Sapeurs Pompiers Robotise) aims to create/build/design a robust response through a robotic platform for early intervention services such as civil and military security in hostile environments. CEA LIST has proposed an adapted solution to detect and characterize nuclear and radiological risks online and in motion, using a miniature embedded CdZnTe (CZT) crystal Gamma-ray spectrometer. This paper presents experimental results for this miniature embedded CZT spectrometer and its associated mathematical method to detect and characterize radiological threats online and in motion. (authors)

42 ENGINEERING↗