Search NASA⌕ Search

SEARCH · Search NASA

Results for “FIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Preexisting compensatory amino acids compromise fitness costs of a HIV-1 T cell escape mutation

Background: Fitness costs and slower disease progression are associated with a cytolytic T lymphocyte (CTL) escape mutation T242N in Gag in HIV-1-infected individuals carrying HLA-B*57/5801 alleles. However, the impact of different context in diverse HIV-1 strains on the fitness costs due to the T242N mutation has not been well characterized. To better understand the extent of fitness costs of the T242N mutation and the repair of fitness loss through compensatory amino acids, we investigated its fitness impact in different transmitted/founder (T/F) viruses. Results: The T242N mutation resulted in various levels of fitness loss in four different T/F viruses. However, the fitness costs were significantly compromised by preexisting compensatory amino acids in (Isoleucine at position 247) or outside (glutamine at position 219) the CTL epitope. Moreover, the transmitted T242N escape mutant in subject CH131 was as fit as the revertant N242T mutant and the elimination of the compensatory amino acid I247 in the T/F viral genome resulted in significant fitness cost, suggesting the fitness loss caused by the T242N mutation had been fully repaired in the donor at transmission. Analysis of the global circulating HIV-1 sequences in the Los Alamos HIV Sequence Database showed a high prevalence of compensatory amino acids for the T242N mutation and other T cell escape mutations. Conclusions: Our results show that the preexisting compensatory amino acids in the majority of circulating HIV-1 strains could significantly compromise the fitness loss due to CTL escape mutations and thus increase challenges for T cell based vaccines.

59 BASIC BIOLOGICAL SCIENCES↗

Mouse fat storage‐inducing transmembrane protein 2 ( FIT 2) promotes lipid droplet accumulation in plants

Summary Fat storage‐inducing transmembrane protein 2 ( FIT 2) is an endoplasmic reticulum ( ER )‐localized protein that plays an important role in lipid droplet ( LD ) formation in animal cells. However, no obvious homologue of FIT 2 is found in plants. Here, we tested the function of FIT 2 in plant cells by ectopically expressing mouse ( Mus musculus ) FIT 2 in Nicotiana tabacum suspension‐cultured cells, Nicotiana benthamiana leaves and Arabidopsis thaliana plants. Confocal microscopy indicated that the expression of FIT 2 dramatically increased the number and size of LD s in leaves of N. benthamiana and Arabidopsis, and lipidomics analysis and mass spectrometry imaging confirmed the accumulation of neutral lipids in leaves. FIT 2 also increased seed oil content by ~13% in some stable, overexpressing lines of Arabidopsis . When expressed transiently in leaves of N. benthamiana or suspension cells of N. tabacum , FIT 2 localized specifically to the ER and was often concentrated at certain regions of the ER that resembled ER ‐ LD junction sites. FIT 2 also colocalized at the ER with other proteins known to be involved in triacylglycerol biosynthesis or LD formation in plants, but not with ER resident proteins involved in electron transfer or ER ‐vesicle exit sites. Collectively, these results demonstrate that mouse FIT 2 promotes LD accumulation in plants, a surprising functional conservation in the context of a plant cell given the apparent lack of FIT 2 homologues in higher plants. These results suggest also that FIT 2 expression represents an effective synthetic biology strategy for elaborating neutral lipid compartments in plant tissues for potential biofuel or bioproduct purposes.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting

Purpose: X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). Methods: The CMCF method uses concurrently run MC CBCT scatter projection simulations that are a subset of the projection angles used in the projection set, P, to be corrected. The scattered photons reaching the detector in each MC simulation are simultaneously aggregated by an algorithm which computes the scatter detector response, S{sub MC}. S{sub MC} is fit to a function, S{sub F}, and if the fit of S{sub F} is within a specified goodness of fit (GOF), the simulations are terminated. The fit, S{sub F}, is then used to interpolate the scatter distribution over all pixel locations for every projection angle in the set P. The CMCF algorithm was tested using a frequency limited sum of sines and cosines as the fitting function on both simulated and measured data. The simulated data consisted of an anthropomorphic head and a pelvis phantom created from CT data, simulated with and without the use of a compensator. The measured data were a pelvis scan of a phantom and patient taken on an Elekta Synergy platform. The simulated data were used to evaluate various GOF metrics as well as determine a suitable fitness value. The simulated data were also used to quantitatively evaluate the image quality improvements provided by the CMCF method. A qualitative analysis was performed on the measured data by comparing the CMCF scatter corrected reconstruction to the original uncorrected and corrected by a constant scatter correction reconstruction, as well as a reconstruction created using a set of projections taken with a small cone angle. Results: Pearson’s correlation, r, proved to be a suitable GOF metric with strong correlation with the actual error of the scatter fit, S{sub F}. Fitting the scatter distribution to a limited sum of sine and cosine functions using a low-pass filtered fast Fourier transform provided a computationally efficient and accurate fit. The CMCF algorithm reduces the number of photon histories required by over four orders of magnitude. The simulated experiments showed that using a compensator reduced the computational time by a factor between 1.5 and 1.75. The scatter estimates for the simulated and measured data were computed between 35–93 s and 114–122 s, respectively, using 16 Intel Xeon cores (3.0 GHz). The CMCF scatter correction improved the contrast-to-noise ratio by 10%–50% and reduced the reconstruction error to under 3% for the simulated phantoms. Conclusions: The novel CMCF algorithm significantly reduces the computation time required to estimate the scatter distribution by reducing the statistical noise in the MC scatter estimate and limiting the number of projection angles that must be simulated. Using the scatter estimate provided by the CMCF algorithm to correct both simulated and real projection data showed improved reconstruction image quality.

60 APPLIED LIFE SCIENCES↗

MITR DDE End Fitting Structural Rigidity Analysis

As a part of the design of the MITR Design Demonstration Element (DDE), a new design for the end fittings must be considered to meet specific experiment needs, e.g., compatibility with the geometrical restrictions of the DDE testing location (BR2 test reactor located in Mol, Belgium), and to allow for proper inspection of these test elements during the experiments. The design of the MITR DDE end fittings is substantially different from the design of the end fittings of the MITR LEU fuel elements, with the DDE end fittings considerably smaller in overall size and weight. Consequently, the stiffness of the end fittings as well as of the entire fuel element is affected. The end fittings in the MITR LEU fuel element are designed primarily for proper handling and flow distribution. The stiffness of the end fittings also constitutes a fraction of the total stiffness of the entire fuel element. It is debatable to what extent the end fittings provide the structural rigidity necessary for the fuel element to properly respond to potential loadings. It is presumed that the bulk of the overall stiffness of the element is derived from swaging multiple fuel plates into the side plates. However, the contribution of stiffness from various components of the MITR LEU fuel element and MITR DDE has not been determined so far. The primary objective of the work presented in this report was to assess the extent to which the stiffness of the end fitting in the MITR DDE contributes to the stiffness of the entire fuel element, and how it compares to the equivalent stiffness of the end fitting in the MITR LEU fuel element. Several simplified load cases were analyzed for that purpose using the geometries of the MITR LEU fuel element, MITR DDE, as well as that of the MITR DDE without the top end fitting.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Predictive models of the genetic bases underlying budding yeast fitness in multiple environments

Abstract The ability of organisms to adapt and survive depends on the effects of genes and the environment on fitness. However, the multigenic nature of fitness and genotype-by-environment interactions hinder our understanding of the genetic basis of fitness. Here, we established fitness prediction models for 35 environments using machine learning and existing fitness data and different genetic variant types for a Saccharomyces cerevisiae population. Models revealed that the predictive ability of genetic variants varied across environments, with copy number variants explaining the majority of fitness variation in most cases. Model interpretation showed that different variant types identified distinct gene sets associated with predictive variants. These gene sets were significantly enriched in experimentally validated genes affecting fitness in only a subset of environments, indicating that many genes influencing fitness remain unexplored. Notably, non-experimentally validated genes were more important than validated ones for fitness predictions. Gene contributions to predictions were both isolate- and environment-dependent, pointing to gene-by-gene and gene-by-environment interactions. Furthermore, models uncovered experimentally validated and novel candidate genetic interactions for a well-characterized stress, the fungicide benomyl. These findings highlight the feasibility of identifying the genetic basis of fitness by using different genetic variant types and offer novel targets for future functional analysis.

DNA copy number variations↗

Impact of immune escape mutations on HIV-1 fitness in the context of the cognate transmitted/founder genome

Background: A modest change in HIV-1 fitness can have a significant impact on viral quasispecies evolution and viral pathogenesis, transmission and disease progression. To determine the impact of immune escape mutations selected by cytotoxic T lymphocytes (CTL) on viral fitness in the context of the cognate transmitted/founder (T/F) genome, we developed a new competitive fitness assay using molecular clones of T/F genomes lacking exogenous genetic markers and a highly sensitive and precise parallel allele-specific sequencing (PASS) method. Results: The T/F and mutant viruses were competed in CD4+ T-cell enriched cultures, relative proportions of viruses were assayed after repeated cell-free passage, and fitness costs were estimated by mathematical modeling. Naturally occurring HLA B57-restricted mutations involving the TW10 epitope in Gag and two epitopes in Tat/Rev and Env were assessed independently and together. Compensatory mutations which restored viral replication fitness were also assessed. A principal TW10 escape mutation, T242N, led to a 42% reduction in replication fitness but V247I and G248A mutations in the same epitope restored fitness to wild-type levels. No fitness difference was observed between the T/F and a naturally selected variant carrying the early CTL escape mutation (R355K) in Env and a reversion mutation in the Tat/Rev overlapping region. Conclusions: These findings reveal a broad spectrum of fitness costs to CTL escape mutations in T/F viral genomes, similar to recent findings reported for neutralizing antibody escape mutations, and highlight the extraordinary plasticity and adaptive potential of the HIV-1 genome. Analysis of T/F genomes and their evolved progeny is a powerful approach for assessing the impact of composite mutational events on viral fitness.

Transmitted/founder virus↗

SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions. Conclusion: LOOP can cooperate with any fitting routine functioning as a “robust fit”. In addition, it can be set as a benchmark for film-dose calibration fitting performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cardiorespiratory fitness and health‐related quality of life in adolescents: A longitudinal analysis from the LabMed Physical Activity Study

Abstract Objective The purpose of this study was to examine the longitudinal associations between cardiorespiratory fitness and health‐related quality of life (HRQoL) in a sample of adolescents, and to determine whether changes in cardiorespiratory fitness were associated with HRQoL over a 2‐year follow‐up. Methods This is a longitudinal analysis with 571 Portuguese adolescents (274 boys and 297 girls) aged 12‐18 years. HRQoL was measured with the Kidscreen‐10 questionnaire; the 20 m shuttle‐run was used to estimate cardiorespiratory fitness; socioeconomic status was assessed with the Family Affluence Scale; and pubertal stage was assessed with Tanner stages. Linear regression and analysis of covariance ( ancova s) were used to examine the associations between cardiorespiratory fitness and HRQoL. Results HRQoL decreased over a 2‐year period both in boys and girls ( P < .05). Moreover, girls at baseline and at follow‐up reported significantly lower HRQoL values than boys (between subjects P < .001). After adjustments for potential confounders, regression analyses showed significant cross‐sectional associations between cardiorespiratory fitness and HRQoL both at baseline ( B = 0.095; P = .023) and at follow‐up (B = 0.090; P = .012). ancova showed that adolescents whose cardiorespiratory fitness decreased over time exhibited lower scores of HRQoL at follow‐up, compared to those with persistent high cardiorespiratory fitness; this held after adjustments for age, sex, socioeconomic status, and pubertal stage. Conclusions Changes in cardiorespiratory fitness during adolescence were associated with HRQoL over a 2‐year period. This study suggests that improving cardiorespiratory fitness could be an important strategy in improving the HRQoL of adolescents.

Evaristo, Olga S.↗

The CXSFIT spectral fitting code: Past, present and future

Magnetically confined plasma experiments generate a wealth of spectroscopic data. The first step toward extracting physical parameters is to fit a spectral model to the often complex spectra. The CXSFIT (Charge eXchange Spectroscopy FITting) spectral fitting code was originally developed for fitting charge exchange spectra on JET from the late 1980s onward and has been further developed over decades to keep up with the needs of the users. The primary use is to efficiently fit a large number of spectra with many constrained Gaussian spectral lines of which the physical parameters can be coupled in a user-friendly manner. More recent additions to the code include time-dependent couplings between parameters, flexible background subtraction, and a non-linear coupling scheme between fit parameters. The latter was a pre-requisite for implementing Zeeman and motional Stark effect multiplets in the library of spectral features. The ability to save and replay “fit recipes,” even when multiple iterations are required, has ensured the traceability of the results and is one of the keys to the longevity and success of the code. The code is also in use on other tokamaks (AUG, ST-40) and to fit data from other spectroscopic diagnostics on JET. In this paper, we document the current capabilities and philosophy behind the structure of the code, including some of the algorithms used to calculate spectral features numerically efficiently. We also provide an outline of how CXSFIT could be transferred into a framework that would be able to meet the spectral fitting requirements of future devices, such as ITER.

Delabie, Ephrem G.↗

New fit to the reaction {gamma}p{yields}K{sup +}{lambda}

The reaction {gamma}p{yields}K{sup +}{lambda} has been investigated over the center-of-momentum energy, W, range from threshold up to 2.2 GeV in a tree-level effective Lagrangian model that incorporates most of the well-established baryon resonances with spins equal to or below (5/2). Four less well-established nucleon resonances of higher mass are also included. The fitted parameters consist, for each resonance included, of the products of the coupling strengths at the electromagnetic and strong interaction vertices and, for the less-established nucleon resonances, of the total decay width. For the well-established nucleon resonances, the energy and momentum dependence of the widths are treated within a dynamical model that is normalized to give the empirical decay branching ratios on the resonance mass shells. For the less-established resonances, the total decay width is treated as a single parameter independent of the reaction kinematics. The model is used to fit recent data for the unpolarized differential cross section (CLAS), the induced hyperon polarization asymmetry, P (CLAS, GRAAL, SAPHIR), the beam spin asymmetry, {sigma} (LEPS and GRAAL), and the double-polarization observables C{sub x} and C{sub z} (CLAS). The model results were also compared with LEPS data for the unpolarized differential cross section, but those data were not included in the fit. Two different fits were obtained: one that incorporates SU(3)-symmetry constraints on the Born contributions to the reaction amplitude and one in which these constraints are relaxed. Explicit numerical results are given only for the first fit because the two fits gave nearly identical results for the observables and the {chi}{sup 2} per degree of freedom obtained with the second fit was only marginally better than that of the first fit (<1% better). Results are presented for the fitted observables at several different energies and center-of-momentum (CM) frame kaon angles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-259: Particle Swarm Optimization in Radial Dose Function Fitting for a Novel Iodine-125 Seed

Purpose: To determine the coefficients of bi- and tri-exponential functions for the best fit of radial dose functions of the new iodine brachytherapy source: Iodine-125 Seed AgX-100. Methods: The particle swarm optimization (PSO) method was used to search for the coefficients of the biand tri-exponential functions that yield the best fit to data published for a few selected radial distances from the source. The coefficients were encoded into particles, and these particles move through the search space by following their local and global best-known positions. In each generation, particles were evaluated through their fitness function and their positions were changed through their velocities. This procedure was repeated until the convergence criterion was met or the maximum generation was reached. All best particles were found in less than 1,500 generations. Results: For the I-125 seed AgX-100 considered as a point source, the maximum deviation from the published data is less than 2.9% for bi-exponential fitting function and 0.2% for tri-exponential fitting function. For its line source, the maximum deviation is less than 1.1% for bi-exponential fitting function and 0.08% for tri-exponential fitting function. Conclusion: PSO is a powerful method in searching coefficients for bi-exponential and tri-exponential fitting functions. The bi- and tri-exponential models of Iodine-125 seed AgX-100 point and line sources obtained with PSO optimization provide accurate analytical forms of the radial dose function. The tri-exponential fitting function is more accurate than the bi-exponential function.

60 APPLIED LIFE SCIENCES↗

Definition of the Flexible Image Transport System (FITS), Version 3.0

The Flexible Image Transport System (FITS) has been used by astronomers for over 30 years as a data interchange and archiving format; FITS files are now handled by a wide range of astronomical software packages. Since the FITS format definition document (the "standard") was last printed in this journal in 2001, several new features have been developed and standardized, notably support for 64-bit integers in images and tables, variable-length arrays in tables, and new world coordinate system conventions which provide a mapping from an element in a data array to a physical coordinate on the sky or within a spectrum. The FITS Working Group of the International Astronomical Union has therefore produced this new Version 3.0 of the FITS standard, which is provided here in its entirety. In addition to describing the new features in FITS, numerous editorial changes were made to the previous version to clarify and reorganize many of the sections. Also included are some appendices which are not formally part of the standard. The FITS standard is likely to undergo further evolution, in which case the latest version may be found on the FITS Support Office Web site at http://fits.gsfc.nasa.gov/, which also provides many links to FITS-related resources.

Pence, W. D.↗

Properties of Martian Hematite at Meridiani Planum by Simultaneous Fitting of Mars Mossbauer Spectra

Mossbauer spectrometers [1] on the two Mars Exploration Rovers (MERs) have been making measurements of surface rocks and soils since January 2004, recording spectra in 10-K-wide temperature bins ranging from 180 K to 290 K. Initial analyses focused on modeling individual spectra directly as acquired or, to increase statistical quality, as sums of single-rock or soil spectra over temperature or as sums over similar rock or soil type [2, 3]. Recently, we have begun to apply simultaneous fitting procedures [4] to Mars Mossbauer data [5-7]. During simultaneous fitting (simfitting), many spectra are modeled similarly and fit together to a single convergence criterion. A satisfactory simfit with parameter values consistent among all spectra is more likely than many single-spectrum fits of the same data because fitting parameters are shared among multiple spectra in the simfit. Consequently, the number of variable parameters, as well as the correlations among them, is greatly reduced. Here we focus on applications of simfitting to interpret the hematite signature in Moessbauer spectra acquired at Meridiani Planum, results of which were reported in [7]. The Spectra. We simfit two sets of spectra with large hematite content [7]: 1) 60 rock outcrop spectra from Eagle Crater; and 2) 46 spectra of spherule-rich lag deposits (Table 1). Spectra of 10 different targets acquired at several distinct temperatures are included in each simfit set. In the table, each Sol (martian day) represents a different target, NS is the number of spectra for a given sol, and NT is the number of spectra for a given temperature. The spectra are indexed to facilitate definition of parameter relations and constraints. An example spectrum is shown in Figure 1, together with a typical fitting model. Results. We have shown that simultaneous fitting is effective in analyzing a large set of related MER Mossbauer spectra. By using appropriate constraints, we derive target-specific quantities and the temperature dependence of certain parameters. By examining different fitting models, we demonstrate an improved fit for martian hematite modeled with two sextets rather than as a single sextet, and show that outcrop and spherule hematite are distinct. For outcrop, the weaker sextet indicates a Morin transition typical of well-crystallized and chemically pure hematite, while most of the outcrop hematite remains in a weakly ferromagnetic state at all temperatures. For spherule spectra, both sextets are consistent with weakly ferromagnetic hematite with no Morin transition. For both hematites, there is evidence for a range of particle sizes.

Agresti, D. G.↗

Interference-Fit Life Factors for Roller Bearings

The effect of hoop stresses in reducing cylindrical roller bearing fatigue life was determined for various classes of inner-ring interference fit. Calculations were performed for up to 7 fit classes for each of 10 bearing sizes. The hoop stresses were superimposed on the Hertzian principal stresses created by the applied radial load to calculate roller bearing fatigue life. A method was developed through a series of equations to calculate the life reduction for cylindrical roller bearings. All calculated lives are for zero initial internal clearance. Any reduction in bearing clearance due to interference fit would be compensated by increasing the initial (unmounted) clearance. Results are presented as tables and charts of life factors for bearings with light, moderate, and heavy loads and interference fits ranging from extremely light to extremely heavy for bearing accuracy class RBEC-5 (ISO class 5). Interference fits on the inner ring of a cylindrical roller bearing can significantly reduce bearing fatigue life. In general, life factors are smaller (lower life) for bearings running under light load where the unfactored life is highest. The various bearing series within a particular bore size had almost identical interference-fit life factors for a particular fit. The tightest fit at the high end of the tolerance band produces a life factor of approximately 0.40 for an inner-race maximum Hertz stress of 1200 MPa (175 ksi) and a life factor of 0.60 for an inner-race maximum Hertz stress of 2200 MPa (320 ksi). Interference fits also impact the maximum Hertz stress-life relation.

Oswald, Fred B.↗

AN Fitting Reconditioning Tool

A tool was developed to repair or replace AN fittings on the shuttle external tank (ET). (The AN thread is a type of fitting used to connect flexible hoses and rigid metal tubing that carry fluid. It is a U.S. military-derived specification agreed upon by the Army and Navy, hence AN.) The tool is used on a drill and is guided by a pilot shaft that follows the inside bore. The cutting edge of the tool is a standard-size replaceable insert. In the typical Post Launch Maintenance/Repair process for the AN fittings, the six fittings are removed from the ET's GUCP (ground umbilical carrier plate) for reconditioning. The fittings are inspected for damage to the sealing surface per standard operations maintenance instructions. When damage is found on the sealing surface, the condition is documented. A new AN reconditioning tool is set up to cut and remove the surface damage. It is then inspected to verify the fitting still meets drawing requirements. The tool features a cone-shaped interior at 36.5 , and may be adjusted at a precise angle with go-no-go gauges to insure that the cutting edge could be adjusted as it wore down. One tool, one setting block, and one go-no-go gauge were fabricated. At the time of this reporting, the tool has reconditioned/returned to spec 36 AN fittings with 100-percent success of no leakage. This tool provides a quick solution to repair a leaky AN fitting. The tool could easily be modified with different-sized pilot shafts to different-sized fittings.

Lopez, Jason↗

A New Compression Method for FITS Tables

As the size and number of FITS binary tables generated by astronomical observatories increases, so does the need for a more efficient compression method to reduce the amount disk space and network bandwidth required to archive and down1oad the data tables. We have developed a new compression method for FITS binary tables that is modeled after the FITS tiled-image compression compression convention that has been in use for the past decade. Tests of this new method on a sample of FITS binary tables from a variety of current missions show that on average this new compression technique saves about 50% more disk space than when simply compressing the whole FITS file with gzip. Other advantages of this method are (1) the compressed FITS table is itself a valid FITS table, (2) the FITS headers remain uncompressed, thus allowing rapid read and write access to the keyword values, and (3) in the common case where the FITS file contains multiple tables, each table is compressed separately and may be accessed without having to uncompress the whole file.

Pence, William↗

Automatic fitting of multiple-field solid-state NMR spectra

The NMR lineshapes produced by half-integer quadrupolar nuclei are sensitive to 11 distinct fit parameters per inequivalent site. To date, automatic fitting routines have failed to replace manual parameter insertion and evaluation due to the importance of local minima and the need for fitting multiple-field magic-angle spinning (MAS) and static spectra simultaneously. Herein we introduce a new tool, AMES-Fit (Automatic Multiple Experiment Simulation and Fitting), to automatically find the global best-fit simulation parameters for a series of multiple-field NMR lineshapes. AMES-Fit uses an adaptive step size random search algorithm to dynamically probe parameter space and requires minimal human input. Importantly, the best fits are obtained in a few minutes of computation time that would otherwise have required several person-hours of work. The program is freely available and open-source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular-field-theory fits to magnetic susceptibilities of antiferromagnetic GdCu 2 Si 2 , CuO, LiCrO 2 , and α-CaCr 2 O 4 single crystals below their Néel temperatures

A recently-developed molecular field theory (MFT) has been used to fit single-crystal magnetic susceptibility χ versus temperature T data below the respective antiferromagnetic ordering temperature T N for a variety of collinear and coplanar noncollinear Heisenberg antiferromagnets. The spins in the system are assumed to interact by Heisenberg exchange and to be identical and crystallographically equivalent. The fitting parameters for χ(T ) of collinear antiferromagnets are measurable quantities: the Weiss temperature θ p in the Curie-Weiss law, TN, χ(T N ), and the spin S. For coplanar noncollinear helix and cycloid structures, an additional fitting parameter is the turn angle between layers of ferromagnetically-aligned spins. Here MFT fits to anisotropic χ(T) data from the literature for single crystals of the collinear antiferromagnets GdCu 2 Si 2 and CuO and the noncollinear antiferromagnets LiCrO 2 with a 120° cycloidal structure and α-CaCr 2 O 4 with a 120° helical structure below their respective N´eel temperatures are presented. The MFT fit to the anisotropic χ(T ≤ T N ) data for CuO is poor, whereas the fits to the data for GdCu 2 Si 2 , LiCrO 2 , and α-CaCr 2 O 4 are quite good. The poor fit for CuO is attributed to the influence of strong quantum fluctuations associated with the small Cu spin and the quasi-one-dimensional magnetism that are not taken into account by the MFT. The magnetic contribution to the zero-field heat capacity of the collinear antiferromagnet GdNiGe 3 at T ≤ T N is also fitted by the MFT.

36 MATERIALS SCIENCE↗