Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Propagation and radiation of sound from flanged circular ducts with circumferentially varying wall admittances. I Semi-infinite ducts. II - Finite ducts with sources

Sound propagation in infinite, semiinfinite, and finite circular ducts with circumferentially varying wall admittances is investigated analytically. The infinite case is considered, and an example demonstrates the effects of wall-admittance distribution on dispersion characteristics and mode shapes. An exact solution is obtained for the semiinfinite case, a circular duct with a flanged opening: sidelobe suppression and circumferential-mode energy scattering leading to radiated-field asymmetry are found. A finite duct system with specified hard-walled pressure sources is examined in detail, evaluating reflection coefficients, transmission losses, and radiated-field directivity. Graphs and diagrams are provided, and the implications of the results obtained for the design of aircraft-turbofan inlet liners are discussed.

Fuller, C. R.↗

New flange correction formula applied to interfacial resistance measurements of ohmic contacts to GaAs

A quasi-two-dimensional analytical model is developed to account for vertical and horizontal current flow in and adjacent to a square ohmic contact between a metal and a thin semiconducting strip which is wider than the contact. The model includes side taps to the contact area for voltage probing and relates the 'apparent' interfacial resistivity to the (true) interfacial resistivity, the sheet resistance of the semiconducting layer, the contact size, and the width of the 'flange' around the contact. This relation is checked against numerical simulations. With the help of the model, interfacial resistivities of ohmic contacts to GaAs were extracted and found independent of contact size in the range of 1.5-10 microns.

Lieneweg, Udo↗

Epoxies Bond Waveguides To Flanges

Each waveguide/flange joint made with conductive adhesive and structural adhesive. New two-adhesive joints overcome many of disadvantages of dip-brazed joints, including damage caused by heat of brazing process, corrosion of joints by brazing salts retained in them, cracks in joints, weakening of waveguide material and limitation to use of aluminum alloys, which are only ones dip-brazed. Flange machined slightly oversize and beveled to accommodate structural and conductive adhesives.

Bloom, Jay D.↗

Torsion of Flanged Members with Cross Sections Restrained Against Warping

The longitudinal stresses and the stiffness of flange members - I-beams, channels, and Z-bars - were investigated when these members were subjected to torque with constraint against cross-sectional warping. Measured angles of rotation agreed with corresponding calculated values in which the torsion bending factor of the cross section was involved; the agreement was better for the I-beam and the Z-bar than for the channel. Longitudinal stresses measured at the mid-span were found to agree with the calculated values that involved unit warping as well as the torsion-bending factors: the channel showed the greatest discrepancy between measured and calculated values. When commonly given expressions for rotations and maximum longitudinal stresses in a twisted I-beam were applied to the channel and to the Z-bar, values were obtained that were in reasonably good agreement with values obtained by the method of torsion-bending constant and unit warping.

Hill, H N↗

Stress Analysis of Beams with Shear Deformation of the Flanges

This report discusses the fundamental action of shear deformation of the flanges on the basis of simplifying assumptions. The theory is developed to the point of giving analytical solutions for simple cases of beams and of skin-stringer panels under axial load. Strain-gage tests on a tension panel and on a beam corresponding to these simple cases are described and the results are compared with analytical results. For wing beams, an approximate method of applying the theory is given. As an alternative, the construction of a mechanical analyzer is advocated.

Kuhn, Paul↗

Low conducting metal screen support flange

In a very high or very low temperature duct system in which duct insulation is terminated at selected locations so as to be not coextensive with the duct, an annular metal perforated or mesh screen support flange is used, as a low conductor of heat or cold, between the duct and an outer insulation cover to retain the end of the insulation and to support its usually very thin cover. The screen may be Z-shaped in cross section having a small diameter annular portion to surround and be secured to the duct adjacent the end of the insulation. A generally radially extending portion of the screen extends outwardly from the small diameter portion and adjacent the end of the insulation. The periphery of the radially extending portion is in alignment with the outer peripheral surface of the insulation and the outer peripheral surface of the insulation cover. A large diameter annular portion of the screen extends longitudinally from the periphery in the direction opposite the small diameter portion, and is adapted to surround the insulation and its cover and be secured thereto. The screen may also be U or channel-shaped with one longitudinally directed leg secured to the insulation cover and the other leg secured to the duct under the insulation.

Lestak, Robert G.↗

Elastic-Plastic Fracture Mechanics Analysis of Critical Flaw Size in ARES I-X Flange-to-Skin Welds

NASA's Ares 1 Upper Stage Simulator (USS) is being fabricated from welded A516 steel. In order to insure the structural integrity of these welds it is of interest to calculate the critical initial flaw size (CIFS) to establish rational inspection requirements. The CIFS is in turn dependent on the critical final flaw size (CFS), as well as fatigue flaw growth resulting from transportation, handling and service-induced loading. These calculations were made using linear elastic fracture mechanics (LEFM), which are thought to be conservative because they are based on a lower bound, so called elastic, fracture toughness determined from tests that displayed significant plasticity. Nevertheless, there was still concern that the yield magnitude stresses generated in the flange-to-skin weld by the combination of axial stresses due to axial forces, fit-up stresses, and weld residual stresses, could give rise to significant flaw-tip plasticity, which might render the LEFM results to be non-conservative. The objective of the present study was to employ Elastic Plastic Fracture Mechanics (EPFM) to determine CFS values, and then compare these values to CFS values evaluated using LEFM. CFS values were calculated for twelve cases involving surface and embedded flaws, EPFM analyses with and without plastic shakedown of the stresses, LEFM analyses, and various welding residual stress distributions. For the cases examined, the computed CFS values based on elastic analyses were the smallest in all instances where the failures were predicted to be controlled by the fracture toughness. However, in certain cases, the CFS values predicted by the elastic-plastic analyses were smaller than those predicted by the elastic analyses; in these cases the failure criteria were determined by a breakdown in stress intensity factor validity limits for deep flaws (a greater than 0.90t), rather than by the fracture toughness. Plastic relaxation of stresses accompanying shakedown always increases the calculated CFS values compared to the CFS values determined without shakedown. Thus, it is conservative to ignore shakedown effects.

Chell, G. Graham↗

Flange weld pressure testing

Device allows localized high-pressure proof test. Use of tool eliminates need to block off far end of pipe; only small amount of pressurizing gas is needed; only small area needs to be cleared of personnel for proof test.

Holden, C. F.↗

Elastic distortion of flanged inner ring of high-speed cylindrical roller bearing

The elastic distortion of the inner ring of an experimental roller bearing is investigated analytically. The geometry of the experimental bearing is unusually complex, and for this reason a bearing with an axially symmetric inner ring is also analyzed. Only the inner ring and shaft are considered using a two dimensional finite element program that can accommodate interference between these components. The results suggest that the elastic distortions are modest in relation to the design clearances associated with the experimental bearing. The variation of the radial deflection of the raceway may, however, be significant in some circumstances.

Taylor, C. M.↗

The elastic distortion of the flanged inner ring of a high-speed cylindrical roller bearing

The elastic distortion of the inner ring of an experimental 3,000,000 DN roller bearing is investigated analytically. The geometry of this bearing is unusually complex and for this reason a bearing with an axially symmetric inner ring and shaft is also analyzed. Only the inner ring and shaft are considered using a two-dimensional finite element computer program which enables interference between these components to be accommodated. The results for the experimental bearing suggest that elastic distortions are modest in relation to the design clearances. However, the variation of the radial deflection of the raceway may be significant for some circumstances and the interference fit adopted between the ring and shaft appears to be questionably low.

Taylor, C. M.↗