Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW EQUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The attractor flow for AdS 5 black holes in $\mathcal{N}$ = 2 gauged supergravity

We study the flow equations for BPS black holes in $\mathcal{N}$ = 2 five-dimensional gauged supergravity coupled to any number of vector multiplets via FI couplings. We develop the Noether-Wald procedure in this context and exhibit the conserved charges as explicit integrals of motion, in the sense that they can be computed at any radius on the rotating spacetime. The boundary conditions needed to solve the first order differential equations are discussed in great detail. We extremize the entropy function that controls the near horizon geometry and give explicit formulae for all geometric variables at their supersymmetric extrema. We have also considered a complexification of the near-horizon variables that elucidates some features of the theory from the near-horizon perspective.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cluster bootstrap for cosmological correlators

We show that cosmological wavefunction coefficients associated with n-site chain and loop graphs for a cubic scalar theory in de Sitter spacetime have symbol alphabets given by subsets of A 2n−2 and B 2n−1 cluster variables, respectively, and satisfy the associated cluster adjacency properties. The key step in proving this is identifying a precise connection between graph “tubings” that appear in the kinematic flow equation and polygon “triangulations” that encode the combinatorics of cluster compatibility. Our results imply that cosmological wavefunction coefficients in a general power-law FRW cosmology satisfy cluster adjacency to all orders in the ϵ expansion around the de Sitter limit. We use this information as bootstrap input to show that de Sitter symbols for n ≤ 4 are uniquely determined by simple physical constraints.

differential and algebraic geometry↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New insights into the flow dynamics of a deep freshwater aquifer in the semi-arid and saline Cuvelai-Etosha Basin, Northern Namibia: Results of a multi-environmental tracer study

Study region A paleo-megafan system of the Cubango River in the northern parts of the semi-arid Cuvelai-Etosha Basin, shared by Angola and Namibia. It hosts a deep freshwater aquifer, the so-called Kalahari-Ohangwena 2 (KOH-2), with the potential to resolve the imminent regional water supply shortages. Study focus Hydrogeochemical and multi-environmental tracer studies incorporating the use of age tracers 14 C, 36 Cl, 81 Kr and 4 He to determine the age of groundwater and provide insights into the flow dynamics of the KOH-2. New hydrological insights for the region Stable water isotopes and noble gas thermometry show that in a period with higher rainfall and recharge, temperatures were at least 3 – 4 °C lower than today. Several arguments led to the conclusion that younger groundwater, possibly of an age of 35,000 years, is mixed with ancient saline pore water. These include: 1) the correlation of measured 36 Cl and 81 Kr ratios, as well as 4 He concentrations, using a binary mixing model, and 2) the substantial variation in 81 Kr ages, ranging from 40,000 to 170,000 years, over relatively short distances—a phenomenon challenging to explain by advective groundwater flow equations. Consequently, the ages derived from 81 Kr measurements serve as indicators of the extent of freshening and therefore describe mixing ages rather than absolute travel times.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity-based voltage constraints for optimal power flow in low-voltage distribution feeders

The optimal power flow (OPF) problem for distribution systems can include network details down to the low-voltage (LV) points of interconnection of individual customers. This paper addresses the implementation of voltage magnitude constraints, and sets forth a practicable approach for capturing the effects on voltage from the switching behavior of loads (e.g., heat pumps, air conditioners, water heaters, or pool pumps) and from the variability of renewable generation (e.g., rooftop solar). The proposed method adjusts the OPF voltage constraints based on forecasts of load and generation upper and lower bounds, in conjunction with sensitivity factors derived from the power flow equations. An illustrative OPF formulation is also provided, which incorporates transformer models that include core loss. We demonstrate that accurate modeling of these LV network components is critical to avoid voltage violations at customer points of interconnection. Furthermore, the ideas are validated through numerical case studies on a realistic distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First-order formalism for β functions in bosonic sigma models from supersymmetry breaking

We consider the renormalization group flow equation for the two-dimensional sigma models with the Kähler target space. The first-order formulation allows us to treat perturbations in these models as current-current deformations. We demonstrate, however, that the conventional first-order formalism misses certain anomalies in the measure, and should be amended. We reconcile beta functions obtained within the conformal perturbation theory for the current-current deformations with traditional “geometric” results obtained in the background field methods, in this way resolving the peculiarities pointed out in O. Gamayun et al. [Peculiarities of beta functions in sigma models, J. High Energy Phys. 10 (2023) 097]. The result is achieved by the supersymmetric completion of the first-order sigma model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resilient Operating Constraints for Power Distribution Systems under Setpoint Attacks

Integration and operation of distributed generation (DG) and energy storage (ES) in power distribution systems are enabled by communication networks and embedded sensor and control devices that increase the vulnerability of the systems to cyber-threats, broadening the attack surface and making adversary actions more unpredictable. This paper proposes a methodology that uses ellipsoidal approximations to quantify the potential damage caused by successful attacks that affect, directly or indirectly, the desired operation setpoints and may drive the power distribution operation to unsafe states by violating the limits of voltage or line flows. More specifically, a new methodology is introduced to find the optimal non-symmetric operating constraints that can be imposed to each DG and ES in order to guarantee that the power distribution system is resilient to any malicious setpoints. The proposed method takes as inputs the system topology, DG and ES capabilities, and load limits to solve a convex optimization problem formulated using linear matrix inequalities (LMIs) and the power flow equations. The proposed solution is agnostic to the attacker's action or load profile and it does not require any assumption about the location or means of the attack. The numerical results on a test distribution feeder with several DG and ES illustrate how the proposed resilient operating constraints guarantee the security of the power distribution system under setpoint attacks.

Giraldo, Jairo↗

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Visual Tool for Assessing Stability of DER Configurations on Three-Phase Radial Networks

Here, we present a method and tool for evaluating the placement of Distributed Energy Resources (DER) on distribution circuits in order to control voltages and power flows. Our previous work described Phasor-Based Control (PBC), a novel control framework where DERs inject real and reactive power to track voltage magnitude and phase angle targets. Here, we employ linearized power flow equations and integral controllers to develop a linear state space model for PBC acting on a three-phase unbalanced network. We use this model to evaluate whether a given inverter-based DER configuration admits a stable set of controller gains, which cannot be done by analyzing controllability nor by using the Lyapunov equation. Instead, we sample over a parameter space to identify a stable set of controller gains. Our stability analysis requires only a line impedance model and does not entail simulating the system or solving an optimization problem. We incorporate this assessment into a publicly available visualization tool and demonstrate three processes for evaluating many control configurations on the IEEE 123-node test feeder (123NF).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Tensor Completion Based Approaches for State Estimation in Distribution Systems

Grid state estimation is essential for effective control and management of distribution systems. While weighted least squares has been the conventional method for state estimation, sparsity-aware methods have become popular due to their superior performance with limited data. Matrix completion and compressed sensing-based state estimation approaches exploit the underlying smoothness in the state variables. However, classic matrix completion methods do not take into account the temporal correlation of system states. Compressed sensing methods, on the other hand, require an appropriate choice of sparsifying basis that may not be easy to identify. This paper proposes a blocktensor completion based framework which uses an alternative approach to estimate voltage phasor, power injections and branch currents. This approach utilizes the temporal correlation of the system states in a tensor trace-norm minimization formulation with power flow equations as constraints. Herein, feature scaling is introduced in the problem formulation to benefit from the improved sensitivity of the tensor trace norm to the matrix columns in the scaled unfoldings of the tensor. Weighted tensor norm is utilized to exploit the structures of the different unfoldings of the state measurement tensor to improve the voltage estimation. The estimation accuracy is further improved by alternatively estimating the tensor columns and increasing the available data at each stage in the tensor completion process. The proposed methods are evaluated on the IEEE-33, 37 test systems and a 100- node test system. The proposed methods are shown to provide significant performance gains relative to the classic matrix and tensor completion based approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Synchronization Stability of Grid-Forming Inverters With Passivity-Based Virtual Oscillator Control

In this article, a passivity-based virtual oscillator control strategy with enhanced synchronization stability for grid-forming inverters (GFMs) is proposed. By adopting the port-controlled Hamiltonian system theory for orbital stabilization problems, an energy pumping-and-damping block is proposed to render GFMs globally asymptotically stable with respect to the prespecified solutions of the power-flow equations from any initial condition. This allows for stable integrations of GFMs to any other globally asymptotically stable systems without their explicit knowledge, e.g., helping maintain synchronism with the bulk power system in a wide range of short-circuit-ratio conditions or under large disturbances and keeping synchronism among multiple GFMs in power systems. Herein, both simulations and experiments are presented to demonstrate the proposed control approach.

42 ENGINEERING↗

Multi-Agent Safe Policy Learning for Power Management of Networked Microgrids

This paper presents a supervised multi-agent safe policy learning (SMAS-PL) method for optimal power management of networked microgrids (MGs) in distribution systems. While unconstrained reinforcement learning (RL) algorithms are black-box decision models that could fail to satisfy grid operational constraints, our proposed method considers AC power flow equations and other operational limits. Accordingly, the training process employs the gradient information of operational constraints to ensure that the optimal control policy functions generate safe and feasible decisions. Furthermore, we have developed a distributed consensus-based optimization approach to train the agents’ policy functions while maintaining MGs’ privacy and data ownership boundaries. After training, the learned optimal policy functions can be safely used by the MGs to dispatch their local resources, without the need to solve a complex optimization problem from scratch. Lastly, numerical experiments have been devised to verify the performance of the proposed method.

, policy gradient↗

Additively Manufactured Compliant Hybrid Gas Thrust Bearing for Supercritical Carbon Dioxide Turbomachinery: Experimental Evaluation and Fluid–Structure Model Predictions

This paper presents rotating test results and advances an analytical predictive fluid–structure model for a new type of gas-lubricated thrust bearing fabricated using direct metal laser melting. The bearing concept in this study is a compliant hybrid gas thrust bearing that uses external pressurization to increase load carrying capacity, where the testing campaign in this study was only focused on steady-state static performance. The need for the bearing concept comes from enabling highly efficient supercritical carbon dioxide (sCO2) turbomachinery by replacing oil-lubricated bearings with process gas lubrication. Leveraging the process gas of the turbomachine for bearing lubrication results in lowered bearing power loss, simplified mechanical design, and allows for novel oil-free hermetic drivetrains resulting in an efficient emission-free system. The new concept utilizes hydrostatic pressurization on individual tilting pads flexibly mounted with hermetic squeeze film dampers (HSFDs). This paper focuses on rotating tests of a 173 mm outer diameter gas thrust bearing in air up to 10 krpm and hydrostatic inlet pressures to 365 psi (2.52 MPa). The influence of thrust runner speed and bearing inlet pressure on force deflection characteristics and load carrying capability of the gas film were experimentally evaluated. This work also advances a predictive fluid–structure thrust bearing model using an isothermal ideal-gas-based compressible Reynolds flow equation directly coupled to a lumped stiffness element possessing axial and rotational degrees-of-freedom. The rotating testing demonstrated load capability of 1816 lbs (8.1 kN), which equates to a thrust bearing unit load of 67 psi (0.46 MPa). Gas film force–deflection curves reveal a nonlinear relationship between thrust load and film clearance. Comparison of film thickness values with the predictive model show good agreement under high load and inlet pressure, however deviate as load and pressure decrease. Load capability was shown to increase with increasing hydrostatic inlet pressure, while the increase in thrust runner speed revealed a small decrease in load capacity.

Engineering↗

Master State Distributed Estimator (masde)

The MSE technology provides a distributed state estimation scheme for power utilities by making it a real time dynamic system, versus the static snapshot method used today. This will allow utilities to verify power grid readings and identify false data on the communication network. The prevailing method of estimation takes all the data from the system into a single load flow equation at the utilities command center. This becomes a large algorithm that is very time consuming to solve, providing the engineers only snap shots of the system. The MFD distributes an algorithm to devises that are already installed at various locations on the power grid. This allows for much faster computer times because the algorithms contain magnitudes less data. When each distributed estimator completes its calculation, it sends the results back to the master device to check against all other distributed estimators.

Reen, DylanW.↗

Stress Tensor flows, birefringence in non-linear electrodynamics and supersymmetry

We identify the unique stress tensor deformation which preserves zero-birefringence conditions in non-linear electrodynamics, which is a 4d 4 d version of the T\overline{T} T T ¯ operator. We study the flows driven by this operator in the three Lagrangian theories without birefringence - Born-Infeld, Plebanski, and reverse Born-Infeld - all of which admit ModMax-like generalizations using a root- T\overline{T} T T ¯ -like flow that we analyse in our paper. We demonstrate one way of making this root- T\overline{T} T T ¯ -like flow manifestly supersymmetric by writing the deforming operator in \mathcal{N} = 1 𝒩 = 1 superspace and exhibit two examples of superspace flows. We present scalar analogues in d = 2 d = 2 with similar properties as these theories of electrodynamics in d = 4 d = 4 . Surprisingly, the Plebanski-type theories are fixed points of the classical T\overline{T} T T ¯ -like flows, while the Born-Infeld-type examples satisfy new flow equations driven by relevant operators constructed from the stress tensor. Finally, we prove that any theory obtained from a classical stress-tensor-squared deformation of a conformal field theory gives rise to a related “subtracted” theory for which the stress-tensor-squared operator is a constant.

Physics↗

GO Competition Challenge 1 Benchmark Approach and Validation Support

At the outset ARPA-e’s grid optimization competition sought to test a hypothesis that modern nonlinear optimization methods had reached a level of performance and reliability necessary to optimize energy grids using nonlinear power flow equations. The results demonstrated by this project and the other participants in the grid optimization competition have demonstrated beyond any shadow of doubt that this hypothesis is true. This result suggest that the mathematical optimization technology now exists to produce a revolution in power grid optimization software, which would improve the efficiency of energy grid operations to the broad benefit of society.

24 POWER TRANSMISSION AND DISTRIBUTION↗