Search NASASearch

SEARCH · Search NASA

Results for “FLUID FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

137 records · Page 4

Chiral kinematic theory and converse vortical effects

Response theories in condensed matter typically describe the response of an electron fluid to external electromagnetic fields, while perturbations on neutral particles are often designed to mimic such fields. Here, we study the response of fermions to a space-time-dependent velocity field, thereby sidestepping the issue of gauge charge. First, we use a semiclassical chiral kinematic theory to obtain the local density of current and extract the orbital magnetization. The theory immediately predicts a "converse vortical effect," defined as an orbital magnetization driven by linear velocity. It receives contributions from magnetic moments on the Fermi surface and the Berry curvature of the occupied bands. Then, transcending semiclassics via a complementary Kubo formalism reveals that the uniform limit of a clean system receives only the Berry curvature contribution while other limits sense the Fermi surface magnetic moments too. We propose CoSi as a candidate material and suggest magnetometry of a sample under a thermal gradient to detect the effect. Overall, our study sheds light on the effects of a space-time-dependent velocity field on electron fluids and paves the way for exploring quantum materials using new probes and perturbations.

Chen, Kai [University of Houston]

Future Projection of Tropical Upper-Tropospheric Troughs and Implications for Tropical Cyclone Activity

Summertime tropical upper-tropospheric troughs (TUTTs) provide a unified framework to better understand how extratropical and tropical forcings jointly modulate basin-scale tropical cyclone (TC) activity. In this study, we examine future changes in TUTTs and their implications for TC activity. Multimodel ensemble-mean projections from 45 Coupled Model Intercomparison Project phase 6 (CMIP6) models suggest a contraction of the Pacific TUTT and an expansion of the Atlantic TUTT as the climate warms. Consistently, future changes in environment-based TC indices indicate that the large-scale conditions will become more favorable for TC genesis and intensification over the central North Pacific but less favorable over the tropical North Atlantic and Gulf of Mexico. Utilizing a TC-permitting large-ensemble dataset [i.e., the Database for Policy Decision-Making for Future Climate Change (d4PDF)] that adequately captures the observed interannual TUTT–TC relationships, we further confirm the impacts of projected TUTT changes on the TC activity in a warmer climate. In contrast, the TUTT–TC relationship is poorly represented in most CMIP6 High-Resolution Model Intercomparison Project (HighResMIP) models; such deficiencies call for caution when assessing future TC risk based on explicitly tracked TCs in these models. Additionally, CMIP6 projections show large intermodel spread in TUTT changes, implying uncertainty in projected TC activity, especially over the central-to-eastern Pacific and the North Atlantic. This intermodel spread is associated with interhemispheric sea surface temperature warming asymmetry, which leads to a meridional shift of the intertropical convergence zone (ITCZ) and the simultaneous weakening or strengthening of TUTTs in the North Pacific and North Atlantic. The potential contributions of anthropogenic aerosol forcing and oceanic circulation to this interhemispheric warming asymmetry are briefly examined.

Climate Change

Reduced Order Models for Liquid Hydrogen Pooling and Vaporization Supported by Experiments

In the event of a leak of liquid hydrogen, a pool can form that vaporizes, disperses, and eventually dilutes to a non-flammable mixture. In this work, we describe fast-running models for the pooling and vaporization of liquid hydrogen in a steady cross-wind. Several pooling models from the literature are compared to solve for the flow and extent of the pool. The size of the pool can serve as the source for a separate dispersion model, which builds upon the existing one-dimensional Gaussian plume model in HyRAM+. Additional terms for the effects of a cross-wind on momentum and entrainment were added so that the model could handle the effects of a cross-wind on a low-speed flow. The models are compared to experimental data on pooling extent and downwind dispersion for steady flow rates of liquid hydrogen in a steady cross-wind. In the two compared experiments, liquid flow rates of 15 and 45 g/s were spilled onto concrete in cross-winds of approximately 1.8 m/s. The rate of growth of the pool and the downwind concentration boundaries are compared to the models, showing good agreement, although additional tuning is needed. These models can contribute to the advancement of codes and standards for liquid hydrogen systems.

dispersion

Mechanically Accelerated Depolymerization of Entangled Linear Polymer Melts

Mechanical forces can enhance the chemical depolymerization of synthetic polymers when shear flow accelerates chain scission. To quantify the extent of mechanically-accelerated scission, the effect of simple shear flow (duration and strength) with low Weissenberg and Deborah numbers was investigated by considering the impact of applied work in both simple shear and shear dominated mixed flows. Hydrogenated polyisoprene was chosen as a model linear, entangled system. The conditions (strain amplitude, frequency, and shearing time) necessary to increase chain scission were assessed in the rubbery melt. Shear flow accelerated chain scission at higher temperatures, suggesting an activated process. Isothermal scission versus work curves were superposed by applying shift factors a T,S , whose Arrhenius-like temperature dependence gave an apparent activation energy for chain scission of ~ 110 kJ/mol, which is likely a combination of the activation energy of viscosity and bond energy. This work provides a base for quantifying the impact of shear on depolymerization of polymer melts and highlight the connection between viscous dissipation and scission chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Decadal-Scale Hydrothermal Alteration of Basalt: Implications for Long-Term Reactivity in Subsurface Technologies

Global demands to secure critical mineral supply chains and managing water resources require innovative resource management strategies. Subsurface basalt reservoirs offer a dual-purpose application, where CO2 enhanced critical metal recovery can be coupled with water remediation strategies for the extraction of economically important and environmentally relevant elements. This study utilizes static batch experiments conducted on Columbia River Basalt Group samples to evaluate long-term fluid–rock interactions relevant to coupled subsurface applications. Samples were reacted under elevated temperature and pressure conditions, for 296 and 4,061 days, providing a unique dataset to assess geochemical evolution, element partitioning, and aqueous chemistry over decadal timescales. The alteration was dominated by silicate, aluminosilicate, and oxide phases. Progressive hydrothermal alteration increased the cation exchange capacity through the formation of secondary minerals (e.g. clays and zeolites), influencing solute retention, ion exchange behavior, and aqueous chemistry. Grain-scale and bulk analyses revealed selective cation release and retention patterns, establishing a mechanistic baseline for predicting element mobility. These geochemical constraints inform the prospective use of CO2-enhanced metal recovery for critical resources (e.g. Co, Ni, Mn, Mg, Ti, Fe) and associated water-quality impacts, providing a foundation for the design and management of engineered fluid–rock systems in basalt reservoirs.

Gibson, Marie N.

Toward an AI-Powered Software Pipeline for Real-Time Tracking and Analysis of Wildfire and Smoke

Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...

Color segmentation

Capturing Secondary Kinetic Instabilities in Three‐Dimensional Dayside Reconnection Using an Improved Gradient‐Based Closure

Magnetic reconnection is a highly dynamic process that excites a wide variety of kinetic waves and instabilities. Transverse current sheet instabilities such as the lower-hybrid drift and secondary drift-kink instabilities in particular have been shown by kinetic simulations to modify the reconnection and introduce significant turbulence and mixing to the reconnection layer. Past studies using the ten-moment fluid model to capture important kinetic physics such as the electron inertia and full representation of the pressure tensor proved advantageous to a two-fluid representation of reconnection, but the model struggled when using a local relaxation closure for the heat flux to replicate the current sheet instabilities and subsequent mixing seen in kinetic simulations. This work uses the Gkeyll software framework to perform simulations of asymmetric reconnection based on the 16 October 2015 MMS crossing of a diffusion region, the Burch event. An improved gradient-based heat flux closure is implemented, showing significant improvement in secondary kinetic instabilities that grow in the current sheet. These instabilities generate turbulence which leads to growth of secondary magnetic islands and flux ropes.

Bradshaw, K. [Princeton University, NJ (United Sta

Audible Noise Modeling of Hydrogen Release Sonic Hazards in Rail Maintenance Facilities

This study implemented validated literature models to predict audible noise due to pressurized gaseous hydrogen releases through a thermally-activated pressure relief device (TPRD) and attached vent stack. A literature survey discovered limited hydrogen-specific noise prediction models validated by experiments. However, empirical noise prediction models for air flowing through pipes and valves were identified. These empirical models were used to predict noise levels and compared against hydrogen noise data reported in two studies: one experimental study of noise from hydrogen leaking through a pipe and another which modeled hydrogen flowing through a solenoid valve during a fuel cell vehicle refueling. The valve flow model was then applied to predict noise for hydrogen releases through a TPRD. Results show that hydrogen releases through a TPRD can produce harmful noise levels varying from 134 to 150 dB. However, further model validation and additional experimental data are needed to improve prediction confidence and accuracy.

08 HYDROGEN

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Enhanced Recovery of Critical Minerals and Geological Hydrogen in The Mine of the Future

invited perspective article: The rapid demand for critical minerals (CMs) and hydrogen (H2) necessitates innovative solutions beyond conventional mining. This study explores enhanced mineral recovery (EMR) and geological hydrogen production (GeoH2) by leveraging the Earth’s subsurface as a reactive platform. Using ultramafic rocks and engineered fluids, the approach simultaneously mobilizes critical resources and produces H2 through natural processes like serpentinization. This paradigm offers a transformative pathway to secure essential materials and diversify energy resources, setting a foundation for the Terrestrial Mine of the Future

Yan, Keju

Development of Novel Combustion Codes for Supercritical CO2 Combustion: Cooperative Research and Development Final Report, CRADA Number CRD-20-17182

The Allam-Fetvedt Cycle, a novel supercritical CO2 (sCO2) power cycle developed by 8 Rivers Capital, LLC, generates low-cost power from fossil fuels while capturing combustion-CO2. This cycle employs high-temperature oxy-combustion using sCO2 as the working fluid, leading to a challenging environment for materials. The most critical component for reliable deployment of this technology is the combustor-turbine interface. In the proposed partnership between NREL and 8 Rivers, we will develop a simulation-based tool to provide key design inputs for defining the materials and geometries required in this critical area.

09 BIOMASS FUELS

CO2 Handling & Electrolyzer Efficiency Scaling Evaluator

CHEESE is an interactive dashboard tool for estimating the performance and material requirements of carbon dioxide electrolysis systems. It helps users evaluate how electrode area, current density, product selectivity, gas flow, cell voltage, and the number of cells in a stack affect system operation. The dashboard provides simple and advanced modes so it can be used for both quick estimates and more detailed engineering analysis. Users can estimate product output, carbon dioxide use, electrical power, electrode area, gas and liquid flow rates, energy efficiency, material cost per test, and the effect of scaling from a single cell to a multi cell stack. It also includes tools for examining carbon balance, equipment durability, component replacement, and changes in performance over time. This is intended to help both academia and industry researchers who are either getting into CO2 electrolysis on lab-scale or are trying to establish a larger footprint. CHEESE presents results through tables, charts, and simplified cell and stack diagrams. It is intended to support research planning, experimental design, comparison of operating conditions, and early stage scale up studies.

Prajapati, Aditya [Lawrence Livermore National Lab

Time-Resolved Stochastic Dynamics of Quantum Thermal Machines

Steady-state quantum thermal machines are typically characterized by a continuous flow of heat between different reservoirs. However, at the level of discrete stochastic realizations, heat flow is unraveled as a series of abrupt quantum jumps, each representing an exchange of finite quanta with the environment. Here, in this work, we present a framework that resolves the dynamics of quantum thermal machines into cycles classified as enginelike, coolinglike, or idle. We analyze the statistics of individual cycle types and their durations, enabling us to determine both the fraction of cycles useful for thermodynamic tasks and the average waiting time between cycles of a given type. Central to our analysis is the notion of intermittency, which captures the operational consistency of the machine by assessing the frequency and distribution of idle cycles. Our framework offers a novel approach to characterizing thermal machines, with significant relevance to experiments involving mesoscopic transport through quantum dots.

full counting statistics

An attention-based neural ordinary differential equation framework for modeling inelastic processes

To preserve strictly conservative behavior as well as model the variety of dissipative behavior displayed by solid materials, we propose a significant enhancement to the internal state variable-neural ordinary differential equation (ISV-NODE) framework. In this data-driven, physics-constrained modeling framework internal states are inferred rather than prescribed. The ISV-NODE consists of: (a) a stress model dependent on observable deformation and inferred internal state, and (b) a model of the evolution of the internal states. The enhancements to ISV-NODE proposed in this work are multifold: (a) a partially input convex neural network stress potential provides polyconvexity in terms of observed strain while leaving the inferred state unconstrained, and (b) an internal state flow model uses common latent features to inform novel attention-based gating and drives the flow of internal state only in dissipative regimes. We demonstrated that this architecture can accurately model dissipative and conservative behavior across an isotropic, isothermal elastic-viscoelastic-elastoplastic spectrum with three exemplars, while maintaining fundamental principles by design.

97 MATHEMATICS AND COMPUTING

Amazonian fog harbors viable microbes

Fog formation over tropical forests remains poorly characterized, despite its potential role in bioaerosol dispersion and ecosystem processes. Here, we analyzed fog samples collected at the Amazon Tall Tower Observatory using flow cytometry and culture-based techniques to characterize viable microbial communities. Microbial cell concentrations varied over an order of magnitude across 13 fog events, reaching up to 8 × 104 cells per ml of fog water. Flow cytometry consistently detected metabolically active cells, while culturing and mass spectrometry-based identification yielded eight viable bacterial species and seven fungal taxa. The bacteria Serratia marcescens, Ralstonia pickettii and Sphingomonas paucimobilis exhibited seasonal variations in prevalence. The fungal species identified were primarily mesophilic saprophytes and endophytes, commonly associated with soil and plant surfaces. Our findings indicate that fog harbors viable microbes, including Serratia marcescens and Ralstonia pickettii, which may imply a relevance of fog for microbial dispersal, colonization and nutrient cycling in the Amazon rainforest.

Godoi, Ricardo H. (ORCID:0000000247744870)

Advanced Model Development for Large Eddy Simulation of Oxy-Combustion and Supercritical Carbon Dioxide Power Cycles

A joint experimental and numerical study is performed to observe the characteristics of a supercritical carbon dioxide turbulent mixing layer in the presence of strong nonlinearities in the thermodynamic and transport properties. A bespoke experimental setup is designed and employed for this purpose and provides insight into macroscopic mixing behavior. The mixing is experimentally observed using two techniques: shadowgraphy and spontaneous Raman scattering. Qualitative and quantitative intensity fields obtained via these techniques yield instantaneous and mean density data. Spanwise temperature data is also collected using analogue resistance temperature detectors. These measurements are used to quantify the level of mixed material within the field. The experimental data are supplemented by a companion high-fidelity numerical study. The numerical results are obtained through fully resolved, three-dimensional direct numerical simulation. The numerical dataset permits observation of the near-field mixing characteristics, which are difficult to measure experimentally due to the rapid dynamics and sharp thermophysical gradients in this area. Qualitative field visualizations are presented, followed by quantitative mixed material results and observations regarding thermodynamic property trends at select locations within the field. One-dimensional spectra of the turbulent kinetic energy and solenoidal dissipation are provided to observe the spectral characteristics of the flow. Reynolds stress anisotropy is analyzed graphically through anisotropy invariance maps (Lumley triangles). The mixing quantification, spectral data and anisotropy analysis of a flow at these thermodynamic conditions represent the main outcomes of the work.

20 FOSSIL-FUELED POWER PLANTS

Cross-scale interaction between microturbulence and meso-scale reversed shear Alfvén eigenmodes in DIII-D plasmas

Abstract This paper reports global nonlinear gyrokinetic simulations that couple meso-scale reversed shear Alfvén eigenmodes (RSAEs) driven by energetic particles (EPs) and ion temperature gradient (ITG) microturbulence driven by thermal plasma, using equilibrium and profiles from DIII-D discharge #159243. In simulations focusing only on the ITG, electrostatic ITG drives a huge thermal ion heat transport, which is reduced by a factor of 10 to a level close to the experimental value in electromagnetic simulation due to finite β effect. In the simulations coupling the RSAE and ITG, ITG can scatter the resonant EP nonlinearly trapped by the RSAE and damp the zonal flows generated by the RSAE. The regulation of the RSAE by the ITG greatly reduces the initial saturation amplitude of the RSAE but increases the RSAE amplitude and associated EP transport to experimental levels in the quasi-steady state. The RSAE effects on the ITG, specifically the stronger zonal flows generated by the RSAE and the RSAE frequency modulation of the ITG-induced thermal ion heat transport, in turn, leads to a reduction of the thermal ion heat transport by more than a factor of 2 . For a stronger background ITG, the regulation of the RSAE by the ITG is stronger, while the RSAE effects on the ITG are weaker. This work highlights the importance of cross-scale coupling in the dynamics of the AE turbulence and EP transport.

Physics

Selective ion transport through hydrated micropores in polymer membranes

Abstract Ion-conducting polymer membranes are essential in many separation processes and electrochemical devices, including electrodialysis 1 , redox flow batteries 2 , fuel cells 3 and electrolysers 4,5 . Controlling ion transport and selectivity in these membranes largely hinges on the manipulation of pore size. Although membrane pore structures can be designed in the dry state 6 , they are redefined upon hydration owing to swelling in electrolyte solutions. Strategies to control pore hydration and a deeper understanding of pore structure evolution are vital for accurate pore size tuning. Here we report polymer membranes containing pendant groups of varying hydrophobicity, strategically positioned near charged groups to regulate their hydration capacity and pore swelling. Modulation of the hydrated micropore size (less than two nanometres) enables direct control over water and ion transport across broad length scales, as quantified by spectroscopic and computational methods. Ion selectivity improves in hydration-restrained pores created by more hydrophobic pendant groups. These highly interconnected ion transport channels, with tuned pore gate sizes, show higher ionic conductivity and orders-of-magnitude lower permeation rates of redox-active species compared with conventional membranes, enabling stable cycling of energy-dense aqueous organic redox flow batteries. This pore size tailoring approach provides a promising avenue to membranes with precisely controlled ionic and molecular transport functions.

Science & Technology - Other Topics