Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

On-line fast response device and method for measuring dissolved gas in a fluid

A method and device for the measurement of dissolved gas within a fluid. The fluid, substantially a liquid, is pumped into a pipe. The flow of the fluid is temporally restricted, creating one or more low pressure regions. A measurement indicative of trapped air is taken before and after the restriction. The amount of dissolved air is calculated from the difference between the first and second measurements. Preferably measurements indicative of trapped air is obtained from one or more pressure transducers, capacitance transducers, or combinations thereof. In the alternative, other methods such as those utilizing x-rays or gamma rays may also be used to detect trapped air. Preferably, the fluid is a hydraulic fluid, whereby dissolved air in the fluid is detected.

47 OTHER INSTRUMENTATION↗

Completion Report for Well ER-20-12: Corrective Action Units 101 and 102: Central and Western Pahute Mesa

Well ER-20-12 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area Activity. The well was drilled from October 2015 to January 2016 as an addition to the Central and Western Pahute Mesa corrective action units 101 and 102 the Phase II drilling program. Well ER-20-12 was identified based on recommendations of the Pahute Mesa Guidance Team as a result of anomalous tritium detections in groundwater samples collected from Well PM-3 in 2011 and 2013. The primary purpose of the well was to provide information on the hydrogeology in the area downgradient of select underground tests on Western Pahute Mesa and define hydraulic properties in the saturated Tertiary volcanic rocks. The main 46.99-centimeter (cm) (18.5-inch [in.]) borehole was drilled to a depth of 765.14 meters (m) (2,510.3 ft) and the hole opened to 66.04 cm (26 in.); followed by the 50.80-cm (20-in.) surface casing, which was installed and sealed with cement; and a piezometer (p4) was set in the Timber Mountain welded-tuff aquifer (TMWTA) between the casing and the open borehole. The borehole was continued with a 46.99-cm (18.5-in.) drill bit to a depth of 1,326.53 m (4,352.16 ft), and an intermediate 24.44-cm (9.625-in.) casing was installed and sealed to 1,188.72 m (3,900.00 ft) A piezometer (p3) was installed across the Calico Hills zeolitic composite unit (CHZCM) (lava-flow aquifer [LFA]) in the annulus of the open borehole. Two additional piezometers were installed and completed between the intermediate casing and the borehole wall, one (p2) in the CHZCM and one (p1) in the Belted Range aquifer (BRA). The piezometers are set to monitor groundwater properties in the completed intervals. The borehole was continued with a 21.59-cm (8.5-in.) drill bit to a total depth of 1,384.80 m (4,543.33 ft), and the main completion 13.97-cm (5.5-in.) casing was installed in the open borehole across the Pre-Belted Range composite unit (PBRCM). Data collected during hole construction include composite drill cutting samples collected every 3.0 m (10 ft), geophysical logs, hydrophysical logs, percussion core samples, water-quality measurements (including tritium), and water-level measurements. The well penetrated 1,384.4 m (4,543.33 ft) of Tertiary volcanic rocks. The stratigraphy and lithology were generally as expected with one noted exception. A thick lava-flow and related ash-flow tuffs were identified as Calico Hills Formation (Th), and no Crater Flat units were noted. Additionally, many of the Thirsty Canyon and Timber Mountain units were thicker than expected. Fluid levels measured in the borehole during drilling are the following: (1) on November 2, 2015, Navarro measured the fluid level in the borehole at a depth of 492.33 m (1,615.25 ft) below ground surface (bgs); (2) Schlumberger and COLOG recorded fluid levels during geophysical logging on November 4 and 5, 2015, at a depth of 492.86 m (1,617 ft) and 492.25 m (1,615 ft) bgs, respectively; and (3) on December 4, 2015, COLOG and Navarro measured fluid level in the 20-in. casing with an open borehole to 1,326.54 m (4,352.16 ft) bgs at 575.77 m (1,889.00 ft) and 574.03 m (1,883.3 ft) bgs, respectively. These and subsequent water-level measurements indicate a potential head difference of greater than 76.2 m (250 ft) for groundwater in aquifers above and below the Upper Paintbrush confining unit (UPCU). As expected, tritium was occasionally measured above the Safe Drinking Water Act limit (20,000 picocuries per liter [pCi/L]). Lab analysis on four bailed samples and taken from the undeveloped well indicate that the tritium activities average approximately 36,545 pCi/L. All Fluid Management Plan (FMP) requirements for Well ER-20-12 were met. Analysis of monitoring samples and FMP confirmatory samples indicate that fluids generated during drilling at ER-20-12 met the FMP criteria for discharge to the lined sump and designated infiltration area. All sanitary and hydrocarbon waste generated was properly handled and disposed of.

54 ENVIRONMENTAL SCIENCES↗

High vacuum measurements and calibrations, molecular flow fluid transient effects

High vacuum pressure measurements and calibrations below 1 × 10 -8 Torr are problematic. Specifically, measurement accuracies change drastically for vacuum gauges when pressures are suddenly lowered in vacuum systems. How can gauges perform like this? A brief system description is first required to answer this question. Calibrations were performed using a vacuum calibration chamber with attached vacuum gauges. To control chamber pressures, vacuum pumps decreased the chamber pressure while nitrogen tanks increased the chamber pressure. By balancing these opposing pressures, equilibrium in the chamber was maintained at selected set point pressures to perform calibrations. When pressures were suddenly decreased during set point adjustments, a sudden rush of gas from the chamber also caused a surge of gas from the gauges to decrease the pressures in those gauges. Gauge pressures did not return to equilibrium as fast as chamber pressures due to the sparse distribution of gas molecules in the system. This disparity in the rate of pressure changes caused the pressures in different gauges to be different than expected. This discovery was experimentally proven to show that different gauge designs return to equilibrium at different rates, and that gauge accuracies vary for different gauge designs due to fluid transients in molecular flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-invasive fluid density and viscosity measurement

The noninvasively measurement of the density and viscosity of static or flowing fluids in a section of pipe such that the pipe performs as the sensing apparatus, is described. Measurement of a suitable structural vibration resonance frequency of the pipe and the width of this resonance permits the density and viscosity to be determined, respectively. The viscosity may also be measured by monitoring the decay in time of a vibration resonance in the pipe.

47 OTHER INSTRUMENTATION↗

Relation between pore size and the compressibility of a confined fluid

When a fluid is confined to a nanopore, its thermodynamic properties differ from the properties of a bulk fluid, so measuring such properties of the confined fluid can provide information about the pore sizes. Here, we report a simple relation between the pore size and isothermal compressibility of argon confined in such pores. Compressibility is calculated from the fluctuations of the number of particles in the grand canonical ensemble using two different simulation techniques: conventional grand-canonical Monte Carlo and grand-canonical ensemble transition-matrix Monte Carlo. Our results provide a theoretical framework for extracting the information on the pore sizes of fluid-saturated samples by measuring the compressibility from ultrasonic experiments.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Physical Properties of Low-Molecular Weight Polydimethylsiloxane Fluids

Physical property measurements including viscosity, density, thermal conductivity, and heat capacity of low-molecular weight polydimethylsiloxane (PDMS) fluids were measured over a wide temperature range (-50°C to 150°C when possible). Properties of blends of 1 cSt and 20 cSt PDMS fluids were also investigated. Uncertainties in the measurements are cited. These measurements will provide greater fidelity predictions of environmental sensing device behavior in hot and cold environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Completion Report for Well ER-20-7: Corrective Action Units 101 and 102: Central and Western Pahute Mesa

Well ER-20-7 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Restoration Project at the Nevada Test Site, Nye County, Nevada. The well was drilled in June 2009 as part of the Pahute Mesa Phase II drilling program. The primary purpose of the well was to further investigate migration of radionuclides from the nearby, up-gradient TYBO and BENHAM underground nuclear tests, which originally was discovered at Well Cluster ER-20-5. This well also provided detailed hydrogeologic information in the Tertiary volcanic section that will reduce uncertainties within the Pahute Mesa-Oasis Valley hydrostratigraphic framework model. The main 44.45-centimeter hole was drilled to a depth of 681.8 meters and cased with 33.97-centimeter casing to 671.7 meters. The hole diameter was then decreased to 31.12 centimeters, and the well was drilled to total depth of 894.9 meters. The completion string, set to the depth of 890.0 meters, consists of 14.13-centimeter stainless-steel casing hanging from 19.37-centimeter carbon-steel casing. The 14.13-centimeter stainless-steel casing has one continuous slotted interval open to the Topopah Spring aquifer. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 meters, sidewall core samples from 20 depth intervals, various geophysical logs, water quality (primarily tritium) measurements, and water level measurements. The well penetrated 894.9 meters of Tertiary volcanic rock, including two saturated welded-tuff aquifers. A fluid level measurement was obtained during open-hole geophysical well logging for the upper, Tiva Canyon, aquifer at the depth of 615.7 meters on June 19, 2009. The fluid level measured in the open hole on June 27, 2009,after the total depth was reached and the upper aquifer was cased off, was also at the depth of 615.7 meters. Preliminary field measurements indicated 1.5 to 4.5 million picocuries per liter of tritium in the Tiva Canyon aquifer and 20 to 61 million picocuries per liter in the underlying Topopah Spring aquifer.

54 ENVIRONMENTAL SCIENCES↗

High precision Hugoniot measurements on statically pre-compressed fluid helium

Here we describe how the capability for statically pre-compressing fluid targets for Hugoniot measurements utilizing gas gun driven flyer plates has been developed. Pre-compression expands the capability for initial condition control, allowing access to thermodynamic states off the principal Hugoniot. Absolute Hugoniot measurements with an uncertainty less than 3% on density and pressure were obtained on statically pre-compressed fluid helium utilizing a two stage light gas gun. Helium is highly compressible; the locus of shock states resulting from dynamic loading of an initially compressed sample at room temperature is significantly denser than the cryogenic fluid Hugoniot even for relatively modest (0.27–0.38 GPa) initial pressures. Lastly, the dynamic response of pre-compressed helium in the initial density range of 0.21–0.25 g/cm3 at ambient temperature may be described by a linear shock velocity (us) and particle velocity (u p ) relationship: u s = C 0 + su p , with C 0 = 1.44 ± 0.14 km/s and s = 1.344 ± 0.025.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fluid characterization using acoustics

A measurement system and a method for determining steam quality (i.e. vapor mass fraction) measurements of multiphase fluid flowing through pipes are described. An acoustic sensor device consists of an acoustic transmitter and an acoustic receiver that are designed to be attached to a pipe. The acoustic transmitter and the acoustic receiver are exposed to an interior space of the pipe through openings in a wall of the pipe. Acoustic waves generated by the transmitter and captured by the receiver traverse the multiphase fluid flowing into the pipe. Swept-frequency acoustic interferometry (SFAI) technique is used to measure ultrasonic acoustic properties of a fluid. Machine-learning techniques based on principal component analysis, support vector machine regression and support vector machine classification are used for determining steam quality.

47 OTHER INSTRUMENTATION↗

Shear strength and permeability of the cement-casing interface

Here, the shear strength and hydraulic permeability of the interface between well cement and casing was investigated using a triaxial direct shear apparatus. For the first time, these experiments provide measurements under controlled stress conditions with fluid flow measurements along the interface. The low cohesion (1.1 ± 1.1 MPa) and the high friction angle (43.4 ± 2.0°) indicates that the shear strength of the interface is provided by friction. This implies that the state of stress of the cement is critical to well integrity. The hydraulic aperture of the undamaged cement-steel samples was 6.8 ± 1.0 microns. Shear damage to the interface caused a decrease (-20 %) in hydraulic aperture for samples aged up to 1 month, and an increase (+300 %) for samples cured for two years. We performed numerical simulations to estimate the leakage potential from a carbon storage operation. This model predicts negligible leakage amounts (47 tonnes) in a shear-damaged well for the modeled injection of ~1.26 million tonnes of CO 2 . Thus, our measurements indicate that the cement-casing interface is not a significant leakage pathway in its intact or damaged state, and that shear-driven failure scenarios for this interface are not a significant risk to CO 2 storage security.

54 ENVIRONMENTAL SCIENCES↗

A comparison of segmented abdominopelvic fluid volumes with conventional CT signs of abdominal compartment syndrome in a trauma population

Purpose: To compare the utility of abdominopelvic fluid volume measurements with established computed tomography signs for refractory post-traumatic abdominal compartment syndrome. Methods: This retrospective observational cohort study included 64 consecutive adult trauma patients with preoperative CT and diagnosis of refractory abdominal compartment syndrome requiring decompressive laparotomy at a level I trauma referral center between 2004 and 2014. We hypothesized that abdominal fluid volume measurements would be more predictive of the need for early laparotomy than previously described conventional CT signs of refractory ACS. Abdominopelvic fluid volumes were determined quantitatively using semi-automated segmentation software. The following conventional imaging parameters were recorded: abdominal anteroposterior:transverse ratio (round belly sign); infrahepatic vena cava diameter; distal abdominal aortic diameter; largest single small bowel wall diameter; hydronephrosis, inguinal herniation; and mesenteric and body wall edema. For outcome analysis, patients were stratified into two groups: those who underwent early (< 24 h) and late (≥ 24 h) decompressive laparotomy following CT. Correlation analysis, comparison of means, and multivariate logistic regression were performed. Results: Abdominal fluid volumes (p = 0.001) and anteroposterior:transverse ratio (p = 0.009) were increased and inferior vena cava diameter (p = 0.009) was decreased in the early decompressive laparotomy group. Multivariate analysis including conventional CT variables, fluid volumes, and laboratory values revealed abdominal fluid volumes (p = 0.012; Δ in log odds of 1.002/mL) as the only independent predictor of early decompressive laparotomy. Conclusions: Segmented abdominopelvic free fluid volumes had greater predictive utility for decision to perform early decompressive laparotomy than previously described ACS-related CT signs in trauma patients who developed refractory abdominal compartment syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray Compton scattering experiments for fluid alkali metals at high temperatures and pressures

We have developed a high-pressure vessel and a cell for x-ray Compton scattering measurements of fluid alkali metals. Measurements have been successfully carried out for alkali metal rubidium at elevated temperatures and pressures using synchrotron radiation at SPring-8. The width of Compton profiles (CPs) of fluid rubidium becomes narrow with decreasing fluid density, which indicates that the CPs sensitively detect the effect of reduction in the valence electron density. At the request of all authors of the paper, and with the agreement of the Proceedings Editor, an updated version of this article was published on 10 September 2015. The original article supplied to AIP Publishing was not the final version and contained PDF conversion errors in Formulas (1) and (2). The errors have been corrected in the updated and re-published article.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fluid Flow Investigations within a 37 Element CANDU Fuel Bundle Supported by Magnetic Resonance Velocimetry and Computational Fluid Dynamics

The current work presents experimental and computational investigations of fluid flow through a 37 element CANDU nuclear fuel bundle. Experiments based on Magnetic Resonance Velocimetry (MRV) permit three-dimensional, three-component fluid velocity measurements to be made within the bundle with sub-millimeter resolution that are non-intrusive, do not require tracer particles or optical access of the flow field. Computational fluid dynamic (CFD) simulations of the foregoing experiments were performed with the hydra-th code using implicit large eddy simulation, which were in good agreement with experimental measurements of the fluid velocity. Greater understanding has been gained in the evolution of geometry-induced inter-subchannel mixing, the local effects of obstructed debris on the local flow field, and various turbulent effects, such as recirculation, swirl and separation. These capabilities are not available with conventional experimental techniques or thermal-hydraulic codes. Finally, the overall goal of this work is to continue developing experimental and computational capabilities for further investigations that reliably support nuclear reactor performance and safety.

42 ENGINEERING↗

Intrinsic rotation generation in ELM-free H-mode plasmas in the DIII-D tokamak--Experimental observations

A detailed description is presented of the experiment reported in [S. H. Mueller et al., Phys. Rev. Lett. 106, 115001 (2011)], which reported the first measurements of fluid turbulent stresses in a tokamak H-mode pedestal. Mach probe measurements disclosed a narrow co-current rotation layer at the separatrix, which is also seen in some L-modes [J. A. Boedo et al., Phys. Plasmas 18, 032510 (2011)]. Independent evidence for the existence of the edge co-rotation layer is presented from main-ion rotation measurements by charge-exchange-recombination spectroscopy in comparable helium plasmas. The probe measurements are validated against density and electron temperature profiles from Thomson scattering and in terms of the measured turbulent particle transport, which is consistent with the global density rise. Non-diffusive non-convective angular momentum transport is required by two independent experimental observations: (1) A persistent dip in the rotation profile separates the edge layer from the evolving core region during intrinsic rotation development. (2) The rotation profiles with co- and counter-current neutral beam injection appear well described as the simple sum of a constant intrinsic part and the beam-driven part, also demonstrating the profile-independence of the intrinsic torque. Characteristics of the turbulent fluctuations composing the fluid turbulent stresses are discussed: Up to 0.5 cm inside the separatrix, the low amplitude of the Reynolds stress (<0.05 Nm of torque) is due to both a reduction of the fluctuation amplitudes at the peak of the edge co-rotation layer and weak correlations between the toroidal and radial velocity fluctuations. Further into the core, the correlations increase significantly up to a value of +0.75, resulting in an almost unidirectional character of the turbulent Reynolds stress, generating substantial counter-current torques up to -2 Nm. Additional mechanisms must be present to balance these torques and explain the co-current core-plasma spin-up at a rate of +0.3 Nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗