Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Formulation, Design and Experimental Verification of an Open Circuit Electro-Hydraulic Actuator

With the recent electrification trend in the fluid power area, more research has been incentivized to the proposal of cost-effective and energy-efficient solutions for hydraulic systems. Hence, electro-hydraulic actuator (EHA) architectures receive increasing attention. The paper proposes a novel open-circuit EHA architecture, with the goal to obtain a cost-effective mobile solution while maximizing the overall system efficiency. The proposed EHA is capable of meeting or exceeding traditional off-road machine performance, therefore enabling further electrification of off-road machines. Four-quadrant functionality, covering the full speed range, is achieved by a combination of a variable electro-hydraulic drive and valves with different functions and is validated by numerical as well as experimental methods. Here, a simulation model based on the Amesim environment and a dedicated test setup was developed to verify the performance. The good match between simulation and experimental results confirms the potential of the formulation approach of the proposed EHA for applications with different duty cycles and power levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods that use harmonic drives for converting reciprocating axial motion to continuous rotary motion, helical drives for converting reciprocating rotary motion to reciprocating axial motion and combinations thereof for converting reciprocating rotary motion to continuous rotary motion

A harmonic drive assembly and fluid-powered linear motors with both axial pistons are rotary piston arrangements incorporating the harmonic drive assembly are disclosed. The motors may be used in downhole drilling applications, but the drive assembly and/or motors may be used in other applications. The assembly, motors and methods use advanced harmonic drives, advanced helical drives, and combinations thereof with 1) motors with axial pistons and reciprocating linear rings to convert reciprocative axial motion to continuous rotary motion, and 2) motors with rotary pistons and reciprocating linear rings to rectify reciprocative rotary motion to continual rotary motion to improve performance over prior configurations.

Raymond, David W.↗

Multi-Pressure Rail System Design with Variable Pressure Control Strategy

This paper presents the design and the control method of a Multiple Pressure Rail system (MPR) with a variable pressure control logic that allows minimization of throttling loss, therefore, increasing the overall fluid power actuation efficiency. An MPR system allows controlling hydraulic actuators with a pressure control logic, as opposed to traditional flow control logics which are well established in mobile applications. A proper setting of the number of pressure rails and the pressure level in each rail permits optimizing the system efficiency of an MPR solution. MPR systems have been recently proposed with different purposes, but seldom adopt variable pressure control strategies to manage the pressure variations in the rails. Moreover, the related past work attempts to maximize the energy recovery during overrunning load conditions. This paper, instead, addresses the case of an MPR system that handles a multitude of hydraulic functions without significant overrunning loads, as it occurs in many mobile applications such as in agriculture. The paper first presents the design alternatives considered for the MPR system, including the supply, the control valves, and the controller. Second, a dedicated test rig is developed to support experimental activities and validations of a lumped parameter model developed within this research to develop the MPR control strategy. The results describe the operating features of the proposed MPR solution. By considering the case of a traditional LS system, the paper results also show how system efficiency can be highly improved, with energy savings in the order of 49%

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods that use harmonic drives for converting reciprocating axial motion to continuous rotary motion, helical drives for converting reciprocating rotary motion to reciprocating axial motion and combinations thereof for converting reciprocating rotary motion to continuous rotary motion

A harmonic drive assembly and fluid-powered linear motors with both axial pistons are rotary piston arrangements incorporating the harmonic drive assembly are disclosed. The motors may be used in downhole drilling applications, but the drive assembly and/or motors may be used in other applications. The assembly, motors and methods use advanced harmonic drives, advanced helical drives, and combinations thereof with 1) motors with axial pistons and reciprocating linear rings to convert reciprocative axial motion to continuous rotary motion, and 2) motors with rotary pistons and reciprocating linear rings to rectify reciprocative rotary motion to continual rotary motion to improve performance over prior configurations. Axial pistons provide a robust simple solution for generating rotation; Rotational pistons provide increased torque generation as the torque generated is proportional to motor length. Since downhole drills are long, a high-torque motor can be produced using this method.

Raymond, David W.↗

Concept to convert electrical power

Moving fluid conductor transforms electrical power from one voltage to another. The electrically conductive fluid acts as a coupling medium between or among multiple electromagnetic fields producing the conversion.

Ratti, N.↗

Nuclear Electric Propulsion Brayton Power Conversion Working Fluid Considerations

NASA has considered Nuclear Electric Propulsion (NEP) for high ∆V missions since the late 1950s, but the current technology readiness level of the requisite power-train needs to be raised for such a mission. The powertrain includes reactor, power conversion, power management, electric propulsion, and thermal management components that must be integrated to minimize system a (kg/kWe) and to finalize a propulsion system architecture within the 2025-2027 timeframe requires advancing these component technologies to technology readiness level (TRL) 5 and Advancement Degree of Difficulty (AD2) 3 in an expeditious manner with minimal risks. This paper will only address the power conversion (heat to electric) components of that system. Based on both internal and industry studies, a primary conclusion of this work is that a single-spool supercritical Xe-He radial flux Brayton heat engine combined with a permanent magnet synchronous alternator can potentially be developed with the least technical risk to meet the technology readiness schedule and required NEP system performance metrics.

Nuclear Electric Propulsion (NEP)↗

Nuclear Electric Propulsion Brayton Power Conversion Working Fluid Considerations

NASA has considered Nuclear Electric Propulsion (NEP) for high V missions since the late 1950’s, but the current technology readiness level of the requisite powertrain needs to be raised for such a mission. The powertrain includes reactor, power conversion, power management, electric propulsion, and thermal management components that must be integrated to minimize system (kg/kWe) and to finalize a propulsion system architecture within the 2025-2027 timeframe requires advancing these component technologies to technology readiness level (TRL) 5 and Advancement Degree of Difficulty (AD2) 3 in an expeditious manner with minimal risks. This paper will only address the power conversion (heat to electric) components of that system. Based on both internal and industry studies, a primary conclusion of this work is that a single-spool supercritical Xe-He radial flux Brayton heat engine combined with a permanent magnet synchronous alternator can potentially be developed with the least technical risk to meet the technology readiness schedule and required NEP system performance metrics.

Nuclear↗

Estimating Vibrational Powers Of Parts In Fluid Machinery

In new method of estimating vibrational power associated with component of fluid-machinery system, physics of flow through (or in vicinity of) component regarded as governing vibrations. Devised to generate scaling estimates for design of new parts of rocket engines (e.g., pumps, combustors, nozzles) but applicable to terrestrial pumps, turbines, and other machinery in which turbulent flows and vibrations caused by such flows are significant. Validity of method depends on assumption that fluid flows quasi-steadily and that flow gives rise to uncorrelated acoustic powers in different parts of pump.

Harvey, S. A.↗

On variable hydrostatic transmission for road vehicles, powered by supply of fluid at constant pressure

Various hydrostatic power transmission systems for automotive applications with power supply at constant pressure and unrestricted flow and with a Volvo Flygmotor variable displacement motor as the principal unit were investigated. Two most promising concepts were analyzed in detail and their main components optimized for minimum power loss at the EPA Urban Driving Cycle. The best fuel consumption is less than 10 lit. per 100 kM for a 1542 kG vehicle with a hydrostatic motor and a two speed gear box in series (braking power not recovered). Realistic system pressure affects the fuel consumption just slightly, but the package volume/weight drastically. Back pressure increases losses significantly. Special attention was paid to description of the behavior and modeling of the losses of variable displacement hydrostatic machines.

Magi, M.↗

Thermal Performance of Triply Periodic Minimal Surface Lattice Structures in Single-Phase Dielectric Fluid Cooling of Power Electronics

Additive manufacturing has transformed thermal management by enabling the production of complex, optimized geometries that conventional manufacturing methods cannot achieve. This study investigates the single-phase convective heat transfer performance of gyroid triply periodic minimal surface (TPMS) lattice structures with functional porosity. TPMS structures provide high surface area to volume ratios and are amenable to 3D printing. A gyroid numerical model was created and validated against an existing experimental study with a similar feature size to the investigated geometries. The TPMS structure has a periodic width of 1.6 mm, a length of 10 mm, and a height of 4 mm, with a functional porosity ranging from 0.5 to 0.8, decreasing with distance from the heated surface. Three different flow configurations were examined for an inlet fluid temperature of 70 °C. The inlet velocities range from 0.01 to 1.2 m/s, corresponding to a Reynolds number range of 10–900 with a heat flux of 50 W/cm 2 applied at the base. AmpCool ® AC-110 dielectric fluid (Prandtl number 59.5) was used as the coolant. Thermal performance and friction characteristics were studied for the three flow orientations. The parallel flow configuration was identified as the most efficient for heat removal. A detailed analysis of the numerical results highlights the underlying physics behind the thermal performance differences among the flow configurations.

33 ADVANCED PROPULSION SYSTEMS↗

A Unique Power System For The ISS Fluids And Combustion Facility

Unique power control technology has been incorporated into an electrical power control unit (EPCU) for the Fluids and Combustion Facility (FCF). The objective is to maximize science throughput by providing a flexible power system that is easily reconfigured by the science payload. Electrical power is at a premium on the International Space Station (ISS). The EPCU utilizes advanced power management techniques to maximize the power available to the FCF experiments. The EPCU architecture enables dynamic allocation of power from two ISS power channels for experiments. Because of the unique flexible remote power controller (FRPC) design, power channels can be paralleled while maintaining balanced load sharing between the channels. With an integrated and redundant architecture, the EPCU can tolerate multiple faults and still maintain FCF operation. It is important to take full advantage of the EPCU functionality. The EPCU acts as a buffer between the experimenter and the ISS power system with all its complex requirements. However, FCF science payload developers will still need to follow guidelines when designing the FCF payload power system. This is necessary to ensure power system stability, fault coordination, electromagnetic compatibility, and maximum use of available power for gathering scientific data.

Fox, David A.↗

High operating temperature heat transfer fluids for solar thermal power generation. Final report

This is the final technical report for the DOE MURI project on developing high-operating temperature heat transfer fluids for solar thermal power generation. This project aimed to evaluate liquid metals as a heat-transport fluid and potential energy storage medium for concentrated solar powered (CSP) systems. The project consisted of five phases, starting with fluid selection and screen and ending with potential CSP integration. The initial fluid selection arrived at heavy liquid metals as candidate fluids such as lead bismuth eutectic (LBE) as the prime liquid-alloy candidate to be studied, given the conditions above. Fifty-seven liquid compositions were initially identified with liquidus temperatures lower than 200°C, composed of elements that provide no driving force to the reduction of Cr 2 O 3 or Al 2 O 3 passivation layers in pipe material which is required for corrosion prevention. LBE was identified as the primary candidate fluid after these compositions were compared against computational thermodynamic modeling to screen all of the selected systems that would be compatible with our design objectives. Twenty-eight of these compositions were also investigated with the rapid characterization methods; the accuracies of the liquidus temperature and the specific heats predicted by the computations were better than 3 percent and 9 percent, respectively. We conducted numerus corrosion tests of various Fe-Cr-Al based steels in LBE and its variants at temperate as high as 800°C. It was found that minor additions to the liquid did not provide sufficient corrosion protection to warrant their use in real applications. Furthermore, we investigated the detailed mechanism of corrosion between heavy liquid metal and the pipe material at these very high temperatures. A liquid metal loop was constructed to operate at these high temperatures. The loop construction and operation lead to valuable lessons learned that will be needed for industrial scale loops. Furthermore, we learned that electromagnetic pumps at these extreme temperatures will have to be reengineered and redesigned to be used for CSP applications.

14 SOLAR ENERGY↗

Single-Phase Dielectric Fluid Thermal Management for Power-Dense Automotive Power Electronics

This paper describes the design and performance of a dielectric fluid cooling concept for automotive power electronics. The concept combines a low-thermal-resistance package (which eliminates metalized ceramic substrates) with a high-performance convective cooling strategy (slot jets impinging on finned surfaces). Modeling was first used to design the cooling system to maximize thermal performance and minimize pumping power. Additionally, a prototype was then fabricated, and experiments were conducted to validate the model predictions using three fluids at various fluid flow rates (16.7 cm 3 /s [1 L/min] to 68.3 cm 3 /s [4.1 L/min]) and inlet temperatures (30C and 70C). The final design was compact (120-cm 3 total volume, including heat exchanger and conceptual power modules) and cooled 12 devices (e.g., silicon carbide). The validated model was then used to predict the junction-to-fluid thermal resistance and pumping power for various conditions, including 40C fluid temperature. The results predict thermal resistance values as low as 19 mm 2 K/W are possible using the dielectric fluid cooling approach. The dielectric fluid cooling system is predicted to provide thermal resistance and pumping power values that are approximately 56% and 90% lower, respectively, compared to an automotive power electronics cooling system.

30 DIRECT ENERGY CONVERSION↗

Design and Testing of a Breadboard Electrical Power Control Unit for the Fluid Combustion Facility Experiment

The Fluid Combustion Facility (FCF) Project and the Power Technology Division at the NASA Glenn Research Center (GRC) at Lewis Field in Cleveland, OH along with the Sundstrand Corporation in Rockford, IL are jointly developing an Electrical Power Converter Unit (EPCU) for the Fluid Combustion Facility to be flown on the International Space Station (ISS). The FCF facility experiment contains three racks: A core rack, a combustion rack, and a fluids rack. The EPCU will be used as the power interface to the ISS 120V(sub dc) power distribution system by each FCF experiment rack which requires 28V(sub dc). The EPCU is a modular design which contains three 120V(sub dc)-to-28V(sub dc) full-bridge, power converters rated at 1 kW(sub e) each bus transferring input relays and solid-state, current-limiting input switches, 48 current-limiting, solid-state, output switches; and control and telemetry hardware. The EPCU has all controls required to autonomously share load demand between the power feeds and--if absolutely necessary--shed loads. The EPCU, which maximizes the usage of allocated ISS power and minimizes loss of power to loads, can be paralleled with other EPCUs. This paper overviews the electrical design and operating characteristics of the EPCU and presents test data from the breadboard design.

Kimnach, Greg L.↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

Results of the Workshop on Two-Phase Flow, Fluid Stability and Dynamics: Issues in Power, Propulsion, and Advanced Life Support Systems

The Two-phase Flow, Fluid Stability and Dynamics Workshop was held on May 15, 2003 in Cleveland, Ohio to define a coherent scientific research plan and roadmap that addresses the multiphase fluid problems associated with NASA s technology development program. The workshop participants, from academia, industry and government, prioritized various multiphase issues and generated a research plan and roadmap to resolve them. This report presents a prioritization of the various multiphase flow and fluid stability phenomena related primarily to power, propulsion, fluid and thermal management and advanced life support; and a plan to address these issues in a logical and timely fashion using analysis, ground-based and space-flight experiments.

McQuillen, John↗

Thermophysical Properties Experimentally Tested for NaCl-KCl-MgCl 2 Eutectic Molten Salt as a Next-Generation High-Temperature Heat Transfer Fluids in Concentrated Solar Power Systems

A new eutectic chloride molten salt, MgCl 2 -KCl-NaCl (wt% 45.98–38.91–15.11), has been recognized as one of the most promising high-temperature heat transfer fluids (HTF) for both heat transfer and thermal storage for the third-generation concentrated solar power (CSP) systems. For the first time, some essential thermophysical properties of this eutectic chloride molten salt needed for basic heat transfer and energy storage analysis in the application of concentrating solar power systems have been experimentally tested and provided as functions of temperature in the range from 450 °C to 700 °C. The studied properties include heat capacity, melting point, heat of fusion, viscosity, vapor pressure, density, and thermal conductivity. The property equations provide essential database for engineers to use to calculate convective heat transfer in concentrated solar receivers, heat exchangers, and thermal storage for concentrated solar power plants.

14 SOLAR ENERGY↗

Orbital Fluid Transfer System

An automated fluid and power interface system needs to be developed for future space missions which require on orbit consumable replenishment. Current method of fluid transfer require manned vehicles and extravehicular activity. Currently the US does not have an automated capability for consumable transfer on-orbit. This technology would benefit both Space Station and long duration satellites. In order to provide this technology the Automated Fluid Interface System (AFIS) was developed. The AFIS project was an advanced development program aimed at developing a prototype satellite servicer for future space operations. This mechanism could transfer propellants, cryogens, fluids, gasses, electrical power, and communications from a tanker unit to the orbiting satellite. The development of this unit was a cooperative effort between Marshall Space Flight Center in Huntsville, Alabama, and Moog, Inc. in East Aurora, New York. An engineering model was built and underwent substantial development testing at Marshall Space Flight Center (MSFC). While the AFIS is not suitable for spaceflight, testing and evaluation of the AFIS provided significant experience which would be beneficial in building a flight unit. The lessons learned from testing the AFIS provided the foundation for the next generation fluid transfer mechanism, the Orbital Fluid Transfer System (OFTS). The OFTS project was a study contract with MSFC and Moog, Inc. The OFTS was designed for the International Space Station (ISS), but its flexible design could used for long duration satellite missions and other applications. The OFTS was designed to be used after docking. The primary function was to transfer bipropellants and high pressure gases. The other items addressed by this task included propellant storage, hardware integration, safety and control system issues. A new concept for high pressure couplings was also developed. The results of the AFIS testing provided an excellent basis for the OFTS design. The OFTS meet the servicing requirements for ISS and could also provide the automated fluid and power interface system needed for on orbit consumable resupply of spacecraft into the new century.

Johnston, A. S., (Nick)↗