Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUORESCENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

OH fluorescence in comets - Fluorescence efficiency of the ultraviolet bands

The present investigation is concerned with the calculation of the fluorescence efficiency of OH over a wide range of heliocentric radial velocities. Three vibrational states in each of the two lowest electronic states are included in these calculations, producing a total of nine vibrational bands in the ultraviolet. The attempt is made to reproduce observed, ultraviolet, cometary spectra of OH by utilizing the Swings fluorescence mechanism. The inclusion of four rotational states within each of the three vibrational states and a detailed solar atlas make it possible to match observations very well, although there remain some discrepancies. This ability to reproduce observations provides confidence that the more general results obtained for the fluorescence efficiency as a function of heliocentric radial velocity can be used in interpreting both previous and future observations of OH in comets.

Schleicher, D. G.↗

Fluorescence Correction Vegetation Index (FCVI): A physically based reflectance index to separate physiological and non-physiological information in far-red sun-induced chlorophyll fluorescence

Sun-induced chlorophyll fluorescence (SIF) has been used to track vegetation photosynthetic activity for improving estimation of gross primary productivity (GPP) and detecting plant stress. There are both physical and physiological controls of SIF measured at the surface and retrieved from remote sensing including satellite observations. In order to accurately use SIF for monitoring of plant physiology, the effects of physically-based radiation processes related to leaf and canopy structure, notably photosynthetically active radiation (PAR) absorption and SIF scattering and re-absorption, must be characterized. In this study, we investigate both PAR absorption and SIF scattering processes and find that although it is difficult to quantify their effects individually by using just reflectance, the combined effects of the two processes can be well approximated by a reflectance index. This index, referred to as FCVI (Fluorescence Correction Vegetation Index), is defined as the difference between near-infrared (NIR) and broad-band visible (VIS, 400–700 nm) reflectance acquired under identical sun-canopy-observer geometry of the SIF measurements. The development of the index was based on the physical connection between reflectance and far-red SIF, which was revealed by using the spectral invariant theory. The utility of FCVI to correct far-red SIF for PAR absorption and scattering effects, thus improving the link to photosynthesis, was tested with data from: (i) a field experiment for a growing season; and (ii) a numerical experiment which included a number of scenarios generated by a radiative transfer model. For both the observations and simulations, the FCVI provided a promising estimate of the impact of the physically-based radiation processes on far-red SIF of moderately dense canopies (i.e., FCVI ≥ 0.18). Normalizing the TOC far-red SIF by both the incident PAR (iPAR) and the FCVI provided a good estimate of the far-red fluorescence emission efficiency of the canopies examined. This approach enhances our ability to generalize retrievals for vegetation processes as they change through natural growth phases and seasons. Taken together, far-red SIF and FCVI may enable the assessment of the light partitioning of vegetation canopies, an essential step to facilitate the use of far-red SIF for tracking physiological processes.

Peiqi Yang↗

Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS

We are developing superconducting tunnel junction (STJ) soft X-ray detectors for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS). Our 36-pixel Nb-based STJ spectrometer covers a solid angle {Omega}/4{pi}{approx_equal}10{sup -3}, offers an energy resolution of {approx}10-20 eV FWHM for energies up to {approx}1 keV, and can be operated at total count rates of {approx}10{sup 6} counts/s. For increased quantum efficiency and cleaner response function, we have now started the development of Ta-based STJ detector arrays. Initial devices modeled after our Nb-based STJs have an energy resolution below 10 eV FWHM for X-ray energies below 1 keV, and pulse rise time discrimination can be used to improve their response function for energies up to several keV. We discuss the performance of the Ta-STJs and outline steps towards the next-generation of large STJ detector arrays with higher sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of laser fluorimetry for determining the influence of a single amino-acid substitution on the individual photophysical parameters of a fluorescent form of a fluorescent protein mRFP1

Individual photophysical parameters of the chromophore of a fluorescent protein mRFP1 and its two mutants (amino-acid substitution at position 66 - mRFP1/ Q66C and mRFP1/Q66S proteins) are determined. For this purpose, apart from conventional methods of fluorimetry and spectrophotometry, nonlinear laser fluorimetry is used. It is shown that the individual extinction coefficients of the chromophore of proteins correlate (correlation coefficient above 0.9) with the volume of the substituted amino-acid residue at position 66 (similar to the positions of the absorption, fluorescence excitation and emission maxima). (laser biology and medicine)

74 ATOMIC AND MOLECULAR PHYSICS↗

Cellular response to high pulse repetition rate nanosecond pulses varies with fluorescent marker identity

Nanosecond electric pulses (nsEP's) are a well-studied phenomena in biophysics that cause substantial alterations to cellular membrane dynamics, internal biochemistry, and cytoskeletal structure, and induce apoptotic and necrotic cell death. While several studies have attempted to measure the effects of multiple nanosecond pulses, the effect of pulse repetition rate (PRR) has received little attention, especially at frequencies greater than 100 Hz. In this study, uptake of Propidium Iodide, FM 1–43, and YO-PRO-1 fluorescent dyes in CHO-K1 cells was monitored across a wide range of PRRs (5 Hz–500 KHz) using a laser-scanning confocal microscope in order to better understand how high frequency repetition rates impact induced biophysical changes. We show that frequency trends depend on the identity of the dye under study, which could implicate transmembrane protein channels in the uptake response due to their chemical selectivity. Finally, YO-PRO-1 fluorescence was monitored in the presence of Gadolinium (Gd{sup 3+}), Ruthenium Red, and in calcium-free solution to elucidate a mechanism for its unique frequency trend. - Highlights: • Pulse repetition rate (PRR) is understudied in nanosecond electric pulsing. • 200 V pulses were applied to CHO-K1 cells from 5 Hz to 500 KHz. • Pulsing was repeated using a variety of fluorophores and imaging conditions. • The response is highly dependent on the fluorophore and the imaging conditions. • This may implicate protein channels in the nanoporation response.

60 APPLIED LIFE SCIENCES↗

The Bionanoprobe: Synchrotron-Based Hard X-ray Fluorescence Microscopy for 2D/3D Trace Element Mapping

Trace elements, particularly metals, play an important role in a large variety of cellular processes in a biological system. In the context of biological organisms and tissues, the term trace element means that over the entire organisms an element is present at only trace levels, 100ppm or lower. Trace element distribution and content can be analyzed using several techniques, for example, visible light optical fluorescence imaging, energy-dispersive X-ray spectroscopy on an election microscope, synchrotron-based X-ray fluorescence (XRF) imagine,

59 BASIC BIOLOGICAL SCIENCES↗

Detection of the BICT State in a Borafluorene with High Stokes Shift Fluorescence

Four-coordinate aryl borafluorenes with boron–oxygen and boron–nitrogen dative bonds can exhibit very large fluorescence Stokes shifts. The large Stokes shifts are hypothesized to arise from cleavage of the boron-donor dative bond in the excited state, via a mechanism called bond-cleavage-induced intramolecular charge transfer (BICT). The primary goal of this current investigation is to directly observe the BICT state by performing transient absorption spectroscopy (TAS) on four-coordinate borafluorenes, which have improved optical stability. A novel four-coordinate aryl borafluorene was synthesized which features a dative B–O bond and two tert-butyl moieties on the aryl ring. TAS of the new borafluorene is consistent with the existence of a single, three-coordinate species in the excited state, as predicted by the BICT hypothesis. In conclusion, the TAS data is supported by fluorescence lifetime measurements and DFT calculations.

Absorption↗

Renewable Surface Fluorescence Sandwich Immunoassay Biosensor for Rapid Sensitive Botulinum Toxin Detection in an Automated Fluidic Format

A renewable surface biosensor for rapid detection of botulinum toxin is described based on fluidic automation of a fluorescence sandwich immunoassay, using a recombinant fragment of the toxin heavy chain as a structurally valid simulant. Monoclonal antibodies AR4 and RAZ1 bind to separate epitopes of both this fragment and the holotoxin. The AR4 antibody was covalently bound to Sepharose beads and used as the capture antibody. A rotating rod flow cell was used to capture these beads delivered as a suspension by the sequential injection flow system, creating a 3.6 microliter column. After perfusing the bead column with sample and washing away the matrix, the column was perfused with Alexa 647 dye-labeled RAZ1 antibody as the reporter. Optical fibers coupled to the rotating rod flow cell at a 90 degree angle to one another delivered excitation light from a HeNe laser and collected fluorescent emission light for detection. After each measurement, the used sepharose beads are released and replaced with fresh beads. In a rapid screening approach to sample analysis, the toxin simulant was detected to concentrations of 10 pM in less than 20 minutes.

59 BASIC BIOLOGICAL SCIENCES↗

Quantum process tomography by 2D fluorescence spectroscopy

Reconstruction of the dynamics (quantum process tomography) of the single-exciton manifold in energy transfer systems is proposed here on the basis of two-dimensional fluorescence spectroscopy (2D-FS) with phase-modulation. The quantum-process-tomography protocol introduced here benefits from, e.g., the sensitivity enhancement ascribed to 2D-FS. Although the isotropically averaged spectroscopic signals depend on the quantum yield parameter Γ of the doubly excited-exciton manifold, it is shown that the reconstruction of the dynamics is insensitive to this parameter. Applications to foundational and applied problems, as well as further extensions, are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial-Spectral Representation for X-Ray Fluorescence Image Super-Resolution

X-ray fluorescence (XRF) scanning of works of art is becoming an increasing popular nondestructive analyticalmethod. The high quality XRF spectra is necessary to obtain significant information on both major and minor elements used for characterization and provenance analysis. However, there is a tradeoff between the spatial resolution of an XRF scan and the signalto- noise ratio (SNR) of each pixel’s spectrum, due to the limited scanning time. In this project, we propose an XRF image super-resolution method to address this tradeoff; thus, obtaining a high spatial resolution XRF scan with high SNR. We fuse a lowresolution XRF image and a conventional RGB high-resolution image into a product of both high spatial and high spectral resolution XRF image. There is no guarantee of a one to one mapping between XRF spectrum and RGB color since, for instance, paintings with hidden layers cannot be detected in visible but can in X-ray wavelengths. We separate the XRF image into the visible and nonvisible components. The spatial resolution of the visible component is increased utilizing the high-resolution RGB image, whereas the spatial resolution of the non-visible component is increased using a total variation super-resolution method. Finally, the visible and nonvisible components are combined to obtain the final result.

Dai, Qiqin↗

NPQ (T) : a chlorophyll fluorescence parameter for rapid estimation and imaging of non-photochemical quenching of excitons in photosystem-II-associated antenna complexes: New, rapid probe of non-photochemical quenching

In photosynthesis, light energy is absorbed by light-harvesting complexes and used to drive photochemistry. However, a fraction of absorbed light is lost to non-photochemical quenching (NPQ) that reflects several important photosynthetic processes to dissipate excess energy. Currently, estimates of NPQ and its individual components (q E , q I , q Z and q T ) are measured from pulse-amplitude-modulation (PAM) measurements of chlorophyll fluorescence yield and require measurements of the maximal yield of fluorescence in fully dark-adapted material (F m ), when NPQ is assumed to be negligible. Unfortunately, this approach requires extensive dark acclimation, often precluding widespread or high-throughput use, particularly under field conditions or in imaging applications, while introducing artefacts when F m is measured in the presence of residual photodamaged centres. To address these limitations, we derived and characterized a new set of parameters, NPQ (T) , and its components that can be (1) measured in a few seconds, allowing for high-throughput and field applications; (2) does not require full relaxation of quenching processes and thus can be applied to photoinhibited materials; (3) can distinguish between NPQ and chloroplast movements; and (4) can be used to image NPQ in plants with large leaf movements. Finally, we discuss the applications benefits and caveats of both approaches.

chlorophyll fluorescence↗

Hyperspectral image reconstruction for x-ray fluorescence tomography

A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversion approaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.

Fluorescence microscopy↗

Highly Efficient Blue OLEDs Based on Metal‐Assisted Delayed Fluorescence Pd(II) Complexes

Abstract A series of metal‐assisted delayed fluorescence (MADF) palladium(II) complexes, PdN1N, PdN1N‐dm, and PdN6N, are studied. Their 77 K photoluminescence emission spectra show a narrow primary emission peak at 464, 466, and 470 nm, respectively, with small vibronic peaks characteristic of many phosphorescent emitters. At room temperature (300 K), the dominant emission peaks for PdN1N, PdN1N‐dm, and PdN6N are slightly redshifted to 472, 470, and 476 nm, respectively. In the meantime, a broad sideband is also shown between 410 and 450 nm due to the MADF process. A blue device employing PdN1N‐dm demonstrates an electroluminescence emission peak at 476 nm and the maximum external quantum efficiency (EQE) of 25.1%. The high maximum EQE of the blue organic light‐emitting diode (OLED) device indicates that both the phosphorescence and the delayed fluorescence are very efficient. In addition, a stable OLED device of PdN1N‐dm gives a maximum EQE of 9.8% and the estimated operational lifetime LT 70 of 350 h at the practical luminance of 100 cd m −2 .

Zhu, Zhi‐Qiang↗