Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY SHIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Frequency-Shift Hearing Aid

Proposed hearing aid maps spectrum of speech into band of lower frequencies at which ear remains sensitive. By redirecting normal speech frequencies into frequency band from 100 to 1,500 Hz, hearing aid allows people to understand normal conversation, including telephone calls. Principle operation of hearing aid adapted to other uses such as, clearing up noisy telephone or radio communication. In addition, loud-speakers more easily understood in presence of high background noise.

Weinstein, Leonard M.↗

Frequency shifts in the electron paramagnetic resonance spectrum of 39 K due to spin-exchange collisions with polarized 3 He and precise 3 He polarimetry

The Zeeman splittings and electron paramagnetic resonance frequencies of alkali-metal atoms are shifted in the presence of a polarized noble gas. For a spherical geometry, the shift is enhanced over what is expected classically by a dimensionless atomic parameter 𝜅 0 that is unique to each alkali-metal-atom–noble-gas pair. Here, we present a precise measurement of 𝜅 0 for the 39 K − 3 He system with a relative accuracy of better than 1%. A critical component of achieving subpercent accuracy involved characterizing the shape of our samples using both MRI and CT medical-imaging techniques. The parameter 𝜅 0 plays an important role in establishing the absolute polarization of 3 He in a variety of contexts, including polarized targets for electron-scattering experiments and MRI of the gas space of the lungs. Our measurement more than doubles the accuracy possible when using 𝜅 0 for polarimetry purposes. Just as important, the work presented here represents a direct measurement of 𝜅 0 for the 39 K − 3 He system; previous values for 𝜅 0 in the 39 K − 3 He system relied on a chain of measurements that were benchmarked by previous measurements of 𝜅 0 in the Rb- 3 He system.

Zeeman effect↗

Density-dependent frequency shift of the hydrogen S2/1/ quadrupole line

An optical parametric oscillator pumped with an Nd:YAG laser was used in the investigations along with a White cell and a scanning spectrometer. The frequency of the S2(1) line was measured at a temperature of about 293 K over the density range from 1 to 4.3 amagat with the aid of a technique reported by Douglas and Sharma (1953). It was found that the obtained data are in good agreement with measurements conducted by Fink et al. (1965).

Chackerian, C., Jr.↗

Parameter estimation based on Doppler frequency shifts

An acoustic source generates an amplitude-modulated tone, with Doppler variations due to the relative motion between source and receiver. A method is presented for real-time estimation of tone rest frequency and minimal distance between source and receiver, using digital signal processing techniques. The algorithm presented here was implemented using a Texas Instruments TMS32010 processor.

Statman, Joseph I.↗

Uniaxial stress induced symmetry breaking for muon sites in Fe

Uniaxial stress was used on Fe single crystals to induce muon precession frequency shifts. The frequency shift for a nominally pure Fe sample at 302K was -0.34 + or - .023 MHz per 100 microstrain along the 100 magnetization axis. This corresponds to a change of magnetic field at the muon of 25.1 + to 1.6G/100 magnetic moment. For an Fe (3wt%Si) single crystal the shifts were -0.348 + or - .008 MHz/100 magnetic moment. The agreement between the shifts for Fe and Fe(3wt%Si) shows the effect to be intrinsic to iron and not strongly impurity sensitive. These shifts and their temperature dependence (1/T) are dominated by the effect of strain inducted population shifts between crystallographically equivalent, but mgnetically inequivalent sites. Their magnitudes are in good agreement ith previous theoretical predictions and by previous extrapolation from calculations on Nb and V especially if both 4T(0) and 1T sites contribute comparably.

Kossler, W. J.↗

Elimination of the light shift in rubidium gas cell frequency standards using pulsed optical pumping

Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).

English, T. C.↗

Effect of nonlinear interactions on p-mode frequencies and line widths

We calculate the effect of nonlinear interactions among solar acoustic modes upon the modal frequencies and energy loss rates (or line widths). The frequency shift for a radial p-mode of frequency 3 mHz is found to be about -0.5 microHz. The magnitude of nonlinear frequency shift increases more rapidly with frequency than the inverse mode mass (mode mass is defined as the ratio of energy in the mode to its surface velocity amplitude squared). This frequency shift is primarily due to nonresonant three-mode interactions and is dominated by high l surface gravity waves (f-modes) and p-modes. The line width of a radial p-mode of frequency 3 mHz, due to resonant nonlinear interactions, is about 0.3 microHz. This result is consistent with that of Kumar and Goldreich (1989). We also find, in agreement with these authors, that the most important nonlinear interactions of trapped p-modes involve f-modes and high-frequency p-modes (frequency greater than about 5 mHz) which propagate in the solar photosphere. Thus, using the arguments advanced by Kumar & Goldreich (1989), we conclude that nonlinear couplings cannot saturate the overstable solar p-modes at their small observed amplitudes. Both the nonlinear frequency shifts and line widths, at a fixed frequency, are proportional to the inverse of mode mass which for modes of degree greater than about 100 is approximately l(exp 0.8). Therefore, the frequency of an f-mode of l = 1000, due to nonlinear interactions, is decreased by approximately 0.4%.

Kumar, Pawan↗

Compact piezoelectric resonance mass balance for sample verification and mass quantification and mixing.

There is a need for sample verification and mass quantification of rock, soil and/or ice obtained by sample acquisition mechanisms on extraterrestrial bodies. For many scientific instruments information about the mass of the sample would aid in the interpretation of the data and help prevent the portioning system from overloading instrument ports. Additionally, on a potential sample return mission it is likely that a sample confirmation or mass determination requirement would be implemented before the spacecraft would be commanded to return to Earth or Lunar orbit. In an effort to meet these potential requirements, a piezoelectric resonance balance is being developed to measure a frequency change proportional to the sample mass change. In previous work1 we developed a resonance balance which produced large non-linear frequency changes due to the addition of a large mass. In this study we have looked at a variety of resonator geometries in an effort to linearize the frequency shift with mass. In addition, we have investigated the use of oscillator/counter circuitry to track the frequency shift of the piezoelectric mass balance. In this new design the frequency shifts automatically when a mass is placed on the balance and the counter circuit calculates the frequency shift. This frequency is then converted to a mass using calibration tables determined previously. An additional feature we have implemented is the use of a high frequency thickness mode piezoelectric resonator to mix the sample and a reactant or solvent. This allows for measuring both sample and reagent prior to ingestion by the instrument. This paper will focus on the design requirements and how they are affected by the local gravity and acoustic properties of the sample. Designs which allow for easy loading and unloading of the balance will also be discussed.

Yahnker, Christopher R.↗

Method for Canceling Ionospheric Doppler Effect

Unified transponder system with hydrogen-maser oscillators at both stations can compensate for both motional and ionospheric components of Doppler shift. Appropriate choices of frequency shift in output of mixer m3. System exploits proportionality between dispersive component of frequency shift and reciprocal of frequency to achieve cancellation of dispersive component at output.

Vessot, R. F. C.↗