Search NASA⌕ Search

SEARCH · Search NASA

Results for “FT VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Performance Characteristics of an Axial-flow Transonic Compressor Operating up to Tip Relative Inlet Mach Number of 1.34

Performance data are presented for a transonic axial-flow compressor rotor designed to operate at a tip speed of 1300 ft/sec with maximum relative tip Mach number of 1.37. The compressor had an inlet diameter of 16 inches, a hub-tip diameter ratio of 0.5 and design specific weight flow of 31.1 (lb/sec/(sq ft frontal area). Experimental values of relative total-pressure-loss coefficient were considerably higher than the assumed values. This disparity, hub choking, and application of the simple radial-equilibrium concept are discussed. The data of this report are used to extend previously presented correlation plots of compressor design parameters to higher Mach numbers.

Creagh, John W R↗

Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values

Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm{sup 2} for <1 yr; 1.74 and 1.90 Gy cm{sup 2} for 1 to <5 yr; 2.83 and 3.22 Gy cm{sup 2} for 5 to <10 yr; and 7.34 and 8.68 Gy cm{sup 2} for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm{sup 2}/kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate.

60 APPLIED LIFE SCIENCES↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

Isotopic effect in experiments on lower hybrid current drive in the FT-2 tokamak

To analyze factors influencing the limiting value of the plasma density at which lower hybrid (LH) current drive terminates, the isotopic factor (the difference in the LH resonance densities in hydrogen and deuterium plasmas) was used for the first time in experiments carried out at the FT-2 tokamak. It is experimentally found that the efficiency of LH current drive in deuterium plasma is appreciably higher than that in hydrogen plasma. The significant role of the parametric decay of the LH pumping wave, which hampers the use of the LH range of RF waves for current drive at high plasma densities, is confirmed. It is demonstrated that the parameters characterizing LH current drive agree well with the earlier results obtained at large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microanalysis of carbonate cement δ 18 O in a CO 2 -storage system seal: Insights into the diagenetic history of the Eau Claire Formation (Upper Cambrian), Illinois Basin

Oxygen isotope (δ 18 O) zonation in carbonate mineral cements is often employed as a proxy record (typically with millimeter-scale resolution) of changing temperature regimes during different stages of sediment diagenesis. Recent advances in secondary ion mass spectrometry allow for highly precise and accurate determinations of cement δ 18 O values to be made in situ on a micrometer scale, thus significantly increasing the spatial resolution available to studies of diagenesis in sandstone–shale and carbonate systems. Chemo-isotopically zoned dolomite–ankerite cements within shaly sandstone beds of the predominantly silty–shaly Eau Claire Formation (Cambrian, Illinois Basin) were investigated, revealing the following: with increasing depth of burial (from <0.5 to ~2 km [<1500 to 6500 ft]), cement δ 18 O values decrease from a high of approximately 24‰ down to approximately 14‰ (on the Vienna standard mean ocean water [VSMOW] scale, equivalent to -6.5‰ to -16.5‰ on the Vienna Peedee belemnite [VPDB] scale). The observed cross-basin trend is largely consistent with cements having formed in response to progressive sediment burial and heating. Within the context of independent burial and thermal history models for the Illinois Basin, cementation began soon after deposition and continued intermittently into the mid-Permian. Finally, however, temperatures in excess of burial model predictions are inferred at the time of latest ankerite cement precipitation, which we propose overlapped in time with conductive heating of the Eau Claire Formation (a closed system) from under- and overlying sandstone aquifers that channeled the flow of hot, Mississippi Valley–type mineralizing brines during the mid-Permian (ca. 270 Ma).

58 GEOSCIENCES↗

High Performance Window Retrofit

The US Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) and Traco partnered to develop high-performance windows for commercial building that are cost-effective. The main performance requirement for these windows was that they needed to have an R-value of at least 5 ft 2 ∙ F∙h/Btu. This project seeks to quantify the potential energy savings from installing these windows in commercial buildings that are at least 20 years old. To this end, we are conducting evaluations at a two-story test facility that is representative of a commercial building from the 1980s, and are gathering measurements on the performance of its windows before and after double-pane, clear-glazed units are upgraded with R5 windows. Additionally, we will use these data to calibrate EnergyPlus models that we will allow us to extrapolate results to other climates. Findings from this project will provide empirical data on the benefits from high-performance windows, which will help promote their adoption in new and existing commercial buildings. This report describes the experimental setup, and includes some of the field and simulation results.

EnergyPlus↗

Noise characteristics of the O-1 airplane and some approaches to noise reduction

A brief study of the O-1A airplane to determine possible means for reducing the aircraft aural detection distance was conducted. This effort involved measuring the noise signature of the basic airplane, devising methods to attenuate the noise, and then estimating the effect of several selected modifications on the aural detection distance of the aircraft. A relatively simple modification utilizing a 6.5 ft diameter, six-blade propeller and including a muffler having a volume of 0.725 cu ft is indicated to reduce the aural detection distance of the O-1 aircraft from about 6 miles at an altitude of 1,000 ft and 2 to 3 miles at an altitude of 300 ft to approximately half these values. The flyover noise data suggest that routing the exhaust stacks up and over the wing would provide immediate noise reduction of about 5 dB with an attendant reduction in detection distance. Furthermore, all these studies confirm the work of other investigators that the 1/3 octave band (center frequency=125 cps) is the most critical in reducing aural detection distance.

Connor, A. B.↗

High thermal-transport capacity heat pipes for space radiators

This paper presents the results of performance tests of several dual-slot heat pipe test articles. The dual-slot configuration has a very high thermal transport capability and has been identified as a very promising candidate for the radiator system for the NASA Space Station solar dynamic power modules. Two six-foot long aluminum heat pipes were built and tested with ammonia and acetone. A 20-ft long heat pipe was also built and tested with ammonia. The test results have been compared with performance predictions. A thermal transport capacity of 2000 W at an adverse tilt of 1 in. and a 1000 W capacity at an adverse tilt of 2 in. were achieved on the 20-ft long heat pipe. These values are in close agreement with the predicted performance limits.

Carlson, Albert W.↗

Overall contact conductance of a prototype Parallel Fin Thermal Interface

The Parallel Fin Thermal Interface has been developed and tested as an orbital replaceable interface. The interface consists of two identical plates with pairs of opposing parallel straight fins. Each pair of fins is sandwiched between two insert plates pressed against the fins with enough force for good heat transfer through the interface. Two prototype parallel fin interfaces were built (Model 140 and 380) with different fin and insert plate dimensions. Samples of the interfacing surfaces were found to have roughness values ranging from 22 to 35 microinches. Overall interface conductance (Hc) values of 46.7 to 74.2 Btu/hr sq ft-F were obtained for the 140 model in vacuum with an interface pressure from 18.8 to 37.5 psi, respectively. The Model 380 exhibited Hc values from 31.2 to 46.8 Btu/hr sq ft-F in vacuum, with respective interface pressures of 14.2 and 22.0 psi. Several correlations were found to agree with test data to within 20 percent.

Stobb, C. A.↗

Measurement of the thermal conductivity of composites using heat flow sensors

A thermal conductivity measuring apparatus that uses heat flow sensors to measure the heat flux through samples was constructed of inexpensive materials. This device was used to measure the thermal conductivity (k) of two composites used in the space program that consist of fibrous or granular components embedded in a resin matrix. The k-values that were determined ranged from 0.035 to 0.059 Btu/h sq ft-F/ft (-163 to 553 F) and 0.029 to 0.035 Btu/h-sq ft-F/ft (77 to 212 F). Thermal conductivity values of the composites conformed to the rule of mixture. The accuracy of the system was found to be comparable to the guarded hotplate and it requires neither a skilled operator nor extensive maintenance.

Penn, B. G.↗

Measurements of tropospheric nitric acid over the western United States and northeastern Pacific Ocean

HNO3 measurements obtained in the free troposphere (FT) and boundary layer (BL) over the western U.S. and the NE Pacific during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) program in summer 1986 are reported. The CITE 2 HNO3 instruments and flight protocols are described, and the results are presented in tables and graphs. Over the ocean, the average HNO3 mixing ratios were found to be 108 parts per trillion by volume (pptv) in the FT and 62 pptv in the BL, suggesting removal of HNO3 from the BL by dry deposition. The corresponding values over land were 61 pptv for the FT and 767 pptv for the BL, and the horizontal distribution of BL HNO3 indicated an anthropogenic origin.

Lebel, P. J.↗

Low-altitude wind measurements from wide-body jet transports

For a 2-week period in the spring of 1977, data were collected onboard wide-body jet transports for the determination of winds and wind shear during landings and take-offs. The data represent about 640 take-offs or landings at 14 airports in Europe and the United States. Analysis of the wind-shear data indicates that shears of a given value are equally likely to occur at any altitude in the lower 1400-ft section of the atmosphere. Analysis of the data indicates that low shears (plus or minus .033 knot/per ft) have a 67-percent chance of occurrence during a landing or take-off, while higher values (plus or minus 0.15 knot/per ft) have a 0.5-percent chance of occurrence. A determination of the duration of a given shear was not made.

Dunham, R. E., Jr.↗

Design and Fabrication of Polyisocyanurate Foams toward Significantly Enhanced Thermal Resistivity

Developing high-performance thermal insulation is vital for addressing the ongoing global demand for reduced energy costs. Polyisocyanurate (PIR) foams are commonly used in residential and commercial buildings and in various industrial applications owing to their relatively high thermal insulation properties and fire resistivity. Here, this study aims to further improve the thermal resistivity of PIR foams by (1) incorporating low thermal conductivity blowing agents; (2) tailoring the anisotropy of their cells; (3) tuning polymeric isocyanate quantities; and (4) incorporating a facer barrier, while using steps that easily integrate into current manufacturing processes for PIR foams. The resulting PIR foams exhibit a significant enhancement in thermal resistivity, achieving initial values as high as 8.3 h·ft 2 ·°F/Btu/in., commonly abbreviated as R-8.3/in., which is a 20% improvement compared with that of commercially used PIR foams that achieve approximately R-7/in. The detailed analysis of thermal conductivity measurements, mechanical testing, and morphological characterization elucidates the structure–property relationships. The developed high-performance PIR foams provide a critical pillar for next-generation high-performance insulation, offering promising thermal insulation for buildings and many other applications that have a significant effect on global energy costs.

Anisotropic pores↗

Prototyping and Testing a New Volumetric Curvature Tool for Modeling Reservoir Compartments and Leakage Pathways in the Arbuckle Saline Aquifer: Reducing Uncertainty in CO 2 Storage and Permanence

This DOE-funded project evaluates the utility of seismic volumetric curvature (VC) for predicting stratal and structural architecture diagnostic of paleokarst reservoirs. Of special interest are applications geared toward carbon capture, utilization, and storage (CCUS). VC has been championed for identifying faults (offset <¼ λ) that cannot be imaged by conventional 3-D seismic attributes such as coherence. The objective of this research was to evaluate VC-techniques for reducing uncertainties in reservoir compartmentalization studies and seal risk assessments especially for saline aquifers. A 2000-ft horizontal lateral was purposefully drilled across VC-imaged lineaments—interpreted to record a fractured and a fault-bounded doline—to physically confirm their presence. The 15-mi² study area is located in southeastern Bemis-Shutts Field, which is situated along the crest of the Central Kansas Uplift (CKU) in Ellis County, Kansas. The uppermost Arbuckle (200+ ft) has extensive paleokarst including collapsed paleocaverns and dolines related to exceedingly prolonged pre-Simpson (Sauk–Tippecanoe) and/or pre-Pennsylvanian subaerial exposure. A lateral borehole was successfully drilled across the full extent (~1100 ft) of a VC-inferred paleokarst doline. Triple combo (GR-neutron/density-resistivity), full-wave sonic, and borehole micro-imager logs were successfully run to TD on drill-pipe. Results from the formation evaluation reveal breccias (e.g., crackle, mosaic, chaotic), fractures, faults, vugs (1-6"), and unaffected host strata consistent with the pre-spud interpretation. Well-rounded pebbles were also observed on the image log. VC-inferred lineaments coincide with 20–80-ft wide intervals of high GR values (100+ API), matrix-rich breccias, and faults. To further demonstrate their utility, VC attributes are integrated into a geocellular modeling workflow: 1) to constrain the structural model; 2) to generate facies probability grids, and; 3) to collocate petrophysical models to separate-vug rock fabrics along solution-enlarged fault and fracture systems. Simulation-based studies demonstrate a potential alternative field development model for developing CO 2 storage sites that target carbonate reservoirs overprinted by paleokarst. Simulation results for this complex reservoir indicate that individual fault blocks could function as discrete containers for CO 2 storage thereby reducing the risk of plume migration outside the legally defined extent of the permitted storage site. Vertically extensive, anastomosing, solution-enlarged fault/fracture systems — infilled by clay-rich sediments — would operate as non-to-low permeability vertical "curtains" that restrict CO 2 movement beyond the confines of the CO 2 storage site. Such a location could be developed in a checker-board fashion with CO 2 injection operations occurring in one block and surveillance operations occurring in the adjacent block. Such naturally partitioned reservoirs may be ideal candidates for reducing risks associated with CO 2 plume breakthrough.

02 PETROLEUM↗

New Experiment to Measure the Electron Electric Dipole Moment

An electron can possess an electric dipole moment (edm) only if time reversal symmetry (T) is violated. No edm of any particle has yet been discovered. CP-violation, equivalent to T-violation by the CPT theorem, does occur in Kaon decays and can be accounted for by the standard model. However, this mechanism leads to an electron edm d(sub e) of the order of 10(exp -38) e cm, whereas the current experimental bound on d(sub e) is about 10(exp -27) e cm. However, well-motivated extensions of the standard model such as supersymmetric theories do predict that de could be as large as the current bound. In addition, CP violation in the early universe is required to explain the preponderance of matter over anti-matter, but the exact mechanism of this CP violation is unclear. For these reasons, we are undertaking a new experimental program to determine de to an improved accuracy of 10(exp -29) e cm. Our experiment will use laser-cooled, trapped Cesium atoms to measure the atomic edm d(sub Cs) that occurs if d(sub e) is not zero. In order to do this, we will measure the energy splitting between the atoms spin states in parallel electric and magnetic fields. The signature of an edm would be a linear dependence of the splitting on the electric field E due to the interaction - d(sub Cs) dot E. Our measurement will be much more sensitive than previous measurements because atoms can be stored in the trap for tens of seconds, allowing for much narrower Zeeman resonance linewidths. Also, our method eliminates the most important systematic errors, proportional to atomic velocity, which have limited previous experiments. In this presentation, we will describe the design of our new apparatus, which is presently under construction. An important feature of our experimental apparatus is that magnetic field noise will be suppressed to a very low value of the order of 1 fT/(Hz)1/2. This requires careful attention to the Johnson noise currents in the chamber, which have not been important in previous experiments. In addition we will present estimates of the limits of the various errors that we expect for our experiment.

Kittle, Melanie↗

Design optimization of integrated cooling inserts in modular Fischer-Tropsch reactors

Sustainable production of liquid fuels and feedstocks from atmospheric CO 2 through carbon recycling technologies is necessary to broaden decarbonization efforts and further reduce global emissions. Fischer–Tropsch (FT) reactors can address this challenge by providing storable, high-value liquid hydrocarbon fuels and feedstocks from syngas generated through reductive CO 2 utilization. FT technology, however, is most cost effective at large-scale, fixed-site plants and does not effectively address the smaller, globally distributed CO 2 point sources. Alternatively, smaller, modular reactors can be composed together to the specific scale of the emission source, yielding a flexible solution that enables more widespread deployment. In these modular reactors, thermal management using a finned cooling insert embedded within the catalyst matrix is critical to maintaining the performance and viability. Thus, in this work, topology optimization is used to determine the cooling insert geometry that maximizes reactor productivity while preventing auto-thermal runaway. Optimal designs are generated for varying number of constituent fins and over a range of maximum operating temperatures. Constraints including minimum feature length-scales and prescribed cooling insert material are imposed on the designs to enhance manufacturability. The impact of design features such as insert tapering and increased length scale hierarchy is automatically revealed by the systematic design framework employed. Here, this approach thus generates novel optimal geometries while automating, accelerating, and enhancing the design process compared to traditional heuristic approaches for cooling insert design in modular FT reactors.

30 DIRECT ENERGY CONVERSION↗

Low altitude wind shear statistics derived from measured and FAA proposed standard wind profiles

Wind shear statistics were calculated for a simulated data set using wind profiles proposed as a standard and compared to statistics derived from measured wind profile data. Wind shear values were grouped in altitude bands of 100 ft between 100 and 1400 ft, and in wind shear increments of 0.025 kt/ft between + or - 0.600 kt/ft for the simulated data set and between + or - 0.200 kt/ft for the measured set. No values existed outside the + or - 0.200 kt/ft boundaries for the measured data. Frequency distributions, means, and standard deviations were derived for each altitude band for both data sets, and compared. Also, frequency distributions were derived for the total sample for both data sets and compared. Frequency of occurrence of a given wind shear was about the same for both data sets for wind shears, but less than + or 0.10 kt/ft, but the simulated data set had larger values outside these boundaries. Neglecting the vertical wind component did not significantly affect the statistics for these data sets. The frequency of occurrence of wind shears for the flight measured data was essentially the same for each altitude band and the total sample, but the simulated data distributions were different for each altitude band. The larger wind shears for the flight measured data were found to have short durations.

Dunham, R. E., Jr.↗

HFTS-1 Natural Joint Data and Engineering Summary

This report provides an analysis of engineering and geologic data collected from the Hydraulic Fracturing Test Site #1 (HTSF-1) project in the southern Midland Basin, Reagan County, Texas. The site is being studied as part of the Science-informed Machine Learning for Accelerating Real-Time Decisions in Subsurface Applications (SMART) Initiative at the National Energy Technology Laboratory (NETL). The data collected is intended to provide a basis of understanding of the site and to construct simulation models. This report provides a summary analysis of the engineering and geologic data collected from the project to provide a basis of understanding of the site and to construct simulation models. The report examines various possible correlations in engineering properties based on natural fracture data from the program, which consisted of 11 horizontal wells, one vertical well, and one slant well. The horizontal wells are in two horizons: 1) Upper and 2) Middle Wolfcamp formations. Program data include: fracture frequency and fracture orientation data from four core runs in a slant well; fracture spacing and orientation from a vertical pilot well; laboratory triaxial testing and mineralogical determinations; and porosity results from magnetic resonance analyses from various wells, together with observations based on the data collection. In addition, available references were reviewed on the site for additional insights. As the focus of the report is on the natural system, hydraulic fracture data from the site were not examined in detail in this report. Data variability is the chief observation in examination of the database. Fracture frequency in the slant well can range from sections with values as high as five fractures per ft to sections up to 100+ ft in length with no natural observed fractures. Fracture spacing across is typically less than 10 ft, but can range up to hundreds of feet. Apparent fracturing shows the trends in two predominate orientations, E-SW and WNW-ESE, but minor variations exist. The rock units vary across the site from siliceous mudstones to calcareous mudstones, showing a general layering with depth. The laboratory properties such as strength and modulus show no apparent trend with depth, but appear to correlate with rock mineralogy with high strength and modulus values where calcium content is high. In addition, an attempt to examine variability and mineralogy on a larger scale was made using a color-coded system based on gamma ray measurements. A staged colored approach was adopted, presuming that lower gamma ray values indicate higher value of calcium content (blue scale) and that higher gamma ray values indicate higher clay mineral content (orange scale). As provided in report appendices, the system correlated well with visual examination of the slant core and the petrofabric analyses of the vertical pilot well. The results showed large variability in mineral content along the horizontal plane across the site. The change in mineral content was also rapid, on a scale less than that of the average hydraulic fracture stage length of about 180 ft.

42 ENGINEERING↗