Search NASASearch

SEARCH · Search NASA

Results for “FUNCTION TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

On testing VLSI chips for the big Viterbi decoder

A general technique that can be used in testing very large scale integrated (VLSI) chips for the Big Viterbi Decoder (BVD) system is described. The test technique is divided into functional testing and fault-coverage testing. The purpose of functional testing is to verify that the design works functionally. Functional test vectors are converted from outputs of software simulations which simulate the BVD functionally. Fault-coverage testing is used to detect and, in some cases, to locate faulty components caused by bad fabrication. This type of testing is useful in screening out bad chips. Finally, design for testability, which is included in the BVD VLSI chip design, is described in considerable detail. Both the observability and controllability of a VLSI chip are greatly enhanced by including the design for the testability feature.

Hsu, I. S.

NASA's Functional Task Test: Providing Information for an Integrated Countermeasure System

Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goals of the Functional Task Test (FTT) study were to determine the effects of spaceflight on functional tests that are representative of critical exploration mission tasks and to identify the key physiological factors that contribute to decrements in performance. The FTT was comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and ISS crewmembers participated in this study. Additionally, we conducted a supporting study using the FTT protocol on subjects before and after 70 days of 6 head-down bed rest. The bed rest analog allowed us to investigate the impact of body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare them with the results obtained in our spaceflight study. Spaceflight data were collected on three sessions before flight, on landing day (Shuttle only) and 1, 6 and 30 days after landing. Bed rest subjects were tested three times before bed rest and immediately after getting up from bed rest as well as 1, 6, and 12 days after reambulation. We have shown that for Shuttle, ISS and bed rest subjects, functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. These changes in functional performance were paralleled by similar decrements in sensorimotor tests designed to specifically assess postural equilibrium and dynamic gait control. Bed rest subjects experienced similar deficits both in functional tests with balance challenges and in sensorimotor tests designed to evaluate postural and gait control as spaceflight subjects indicating that body support unloading experienced during spaceflight plays a central role in post-flight alteration of functional task performance. To determine how differences in body-support loading experienced during in-flight treadmill exercise affect postflight functional performance, the loading history for each subject during in-flight treadmill (T2) exercise was correlated with postflight measures of performance. ISS crewmembers who walked on the treadmill with higher pull-down loads had enhanced post-flight performance on tests requiring mobility. Taken together the spaceflight and bed rest data point to the importance of supplementing inflight exercise countermeasures with balance and sensorimotor adaptability training. These data also support the notion that inflight treadmill exercise performed with higher body loading provides sensorimotor benefits leading to improved performance on functional tasks that require dynamic postural stability and mobility.

Bloomberg, J. J.

Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight

The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (p<0.05). Bench press total work was also significantly impaired, although maximal isometric force and power were not significantly affected. No changes were noted for measurements of central activation or force steadiness. Results for ISS crew were not analyzed due to the current small sample size. DISCUSSION: Significant reductions in lower body muscle performance metrics were observed in returning Shuttle crew and these adaptations are likely contributors to impaired functional tasks that are ambulatory in nature (See abstract Functional Task Test: 1). Interestingly, no significant changes in central activation capacity were detected. Therefore, impairments in muscle function in response to short-duration space flight are likely myocellular rather than neuromotor in nature.

Ryder, Jeffrey W.

Analytical evaluation of a surface integral expressing the coupling between interior and exterior volumes in a FE-IE approach

Recently an approach which combines the finite element technique and an integral equation to determine the fields scattered by inhomogeneous bodies of complicated shape has been proposed. Basically, a mathematical surface which encloses the scatterers is introduced, thus dividing the space into an interior and an exterior volume, in which the finite element technique and an integral equation for EM scattering, respectively, are applied. The integral equation is set up for the tangential components of the fields at the surface, while the interior volume the unknowns are the total fields. Continuity of the tangential fields at the boundary, as required by Maxwell's equations, is imposed, thus coupling the two methods to obtain a consistent solution. The coupling term is expressed by a surface integral formed by the dot product of a FE basis function and an IE testing function, or viceversa. By choosing the boundary to be a surface of revolution and by making a convenient selection of IE basis (testing) functions, it is possible to evaluate the integrals analytically on surfaces such as curved triangles, curved quadrilaterals and curved pentagons. We will illustrate the salient steps involved in setting up and carrying out these integrals and discuss what class of basis (testing) functions and analytic surfaces of revolution they are applicable to. Analytic calculations offer the advantage of better accuracy than purely numerical ones, and, when combined with them, often shed light on issues of numerical convergence and limiting values. Furthermore, they may reduce computation time and storage requirements.

Zuffada, C.

On testing of functionally equivalent components of fault-tolerant software

Six functionally equivalent programs were tested with specification based random and extremal/special value (ESV) test cases. Statement and branch coverage were used to measure and compare the attained testing effectiveness. It was observed that both measures reached a nearly steady state value after 25 to 75 random test cases. Coverage saturation curves appear to follow an exponential growth model. However, the steady state values for branch coverage of different components, but the same input cases, differed by as much as 22 percent. The effect is the result of the differences in the detailed structure of the components. Improvement in coverage provided by the random test data, after the ESV cases were executed, was only about 1 percent. Results indicate that extensive random testing can be a process of diminishing returns, and that in the FTS context functional ('black box') testing can provide a very uneven execution coverage of the functionally equivalent software, and therefore should be supplemented by structure based testing.

Vouk, Mladen A.

Examining functional acceptance testing with structural coverage metrics

Functionally generated acceptance tests are examined using structural coverage metrics. A method of comparing acceptance tests and operational usage was generated. Acceptance tests are prepresentative of operational usage except for the mix of statement types. Structural coverage metrics may provide insight into software faults.

Ramsey, J.

Design Process of a Pressure Transducer Vibration Fixture

This paper details the iterative design cycle of a fixture used to mount two types of pressure transducers for vibration testing which allows for functional testing without the removal of the transducers. The objective of the fixture is to prove that the pressure transducers can survive vibrations induced during launch. This would increase the Technology Readiness Level of the pressure transducers which is a requirement for the Lunar Advanced Volatile Analysis subsystem preliminary design review. During the design process, additive manufacturing is considered as a manufacturing method of the fixture as a way to investigate the use of additive manufacturing for the final flight version of the Fluid Sub System manifold. It is ultimately shown that the added ability to perform functional testing and optimization for additive manufacturing made the fixture less than ideal for vibration testing. It is determined that the best option is to design and manufacture a traditional vibration fixture without the ability to perform functional testing of components while attached and a separate part to investigate the application of additive manufacturing to the Fluid Subsystem manifold.

Gilstrap, Andrew

A vestibular phenotype for Waardenburg syndrome?

OBJECTIVE: To investigate vestibular abnormalities in subjects with Waardenburg syndrome. STUDY DESIGN: Retrospective record review. SETTING: Tertiary referral neurotology clinic. SUBJECTS: Twenty-two adult white subjects with clinical diagnosis of Waardenburg syndrome (10 type I and 12 type II). INTERVENTIONS: Evaluation for Waardenburg phenotype, history of vestibular and auditory symptoms, tests of vestibular and auditory function. MAIN OUTCOME MEASURES: Results of phenotyping, results of vestibular and auditory symptom review (history), results of vestibular and auditory function testing. RESULTS: Seventeen subjects were women, and 5 were men. Their ages ranged from 21 to 58 years (mean, 38 years). Sixteen of the 22 subjects sought treatment for vertigo, dizziness, or imbalance. For subjects with vestibular symptoms, the results of vestibuloocular tests (calorics, vestibular autorotation, and/or pseudorandom rotation) were abnormal in 77%, and the results of vestibulospinal function tests (computerized dynamic posturography, EquiTest) were abnormal in 57%, but there were no specific patterns of abnormality. Six had objective sensorineural hearing loss. Thirteen had an elevated summating/action potential (>0.40) on electrocochleography. All subjects except those with severe hearing loss (n = 3) had normal auditory brainstem response results. CONCLUSION: Patients with Waardenburg syndrome may experience primarily vestibular symptoms without hearing loss. Electrocochleography and vestibular function tests appear to be the most sensitive measures of otologic abnormalities in such patients.

NASA Discipline Neuroscience

Functional Task Test (FTT)

This slide presentation reviews the Functional Task Test (FTT), an interdisciplinary testing regimen that has been developed to evaluate astronaut postflight functional performance and related physiological changes. The objectives of the project are: (1) to develop a set of functional tasks that represent critical mission tasks for the Constellation Program, (2) determine the ability to perform these tasks after space flight, (3) Identify the key physiological factors that contribute to functional decrements and (4) Use this information to develop targeted countermeasures.

Bloomberg, Jacob J.

The Functional Task Test: Results from the One-Year Mission

Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems including sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goal of our recently completed Functional Task Test (FTT) study was to determine the effects of spaceflight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. The FTT is comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures specifically targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and International Space Station (ISS) astronauts were tested before and after spaceflight. Additionally, we conducted a supporting study in which subjects performed the FTT protocol before and after 70 days of 6 deg head-down bed rest, an analog for spaceflight. Two groups of bed rest subjects were studied: one group who performed aerobic and resistive exercise during bed rest using protocols similar to astronauts and one group who served as non-exercise controls. The bed rest analog allowed us to isolate the impact of body unloading without other spaceflight environmental factors on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare those results with the results obtained in our spaceflight study. As an extension to the FTT study we collected data from one ISS crewmember who experienced 340 days in space using the same FTT protocol used previously to test spaceflight and bed rest subjects. Data were collected three times preflight and 1.7, 7.5 and 36.5 days after landing. The FTT one-year results will be presented at the meeting, and a comparison will be made with data previously obtained using the same protocol on astronauts tested before and after 6 months in space. Future work will focus on collecting data from additional subjects from one-year flights to gain a better assessment of extreme long-duration exposure to spaceflight on both functional measure of performance and physiological metrics.

Bloomberg, J. J

NSTAR Ion Thruster and Breadboard Power Processor Functional Integration Test Results

A 2.3 kW Breadboard Power Processing Unit (BBPPU) was developed as part of the NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) Program. The NSTAR program will deliver an electric propulsion system based on a 30 cm xenon ion thruster to the New Millennium (NM) program for use as the primary propulsion system for the initial NM flight. The final development test for the BBPPU, the Functional Integration Test, was carried out to demonstrate all aspects of BBPPU operation with an Engineering Model Thruster. Test objectives included: (1) demonstration and validation of automated thruster start procedures, (2) demonstration of stable closed loop control of the thruster beam current, (3) successful response and recovery to thruster faults, and (4) successful safing of the system during simulated spacecraft faults. These objectives were met over the specified 80-120 VDC input voltage range and 0.5-2.3 output power capability of the BBPPU. Two minor anomalies were noted in discharge and neutralizer keeper current. These anomalies did not affect the stability of the system and were successfully corrected.

Hamley, John A.

Validation of Cardiovascular Parameters During NASA's Functional Task Test

Microgravity-induced physiological changes, including cardiovascular deconditioning may impair crewmembers f capabilities during exploration missions on the Moon and Mars. The Functional Task Test (FTT), which will be used to assess task performance in short and long duration astronauts, consists of 7 functional tests to evaluate crewmembers f ability to perform activities to be conducted in a partial-gravity environment or following an emergency landing on Earth. The Recovery from Fall/Stand Test (RFST) tests both the subject fs ability to get up from a prone position and orthostatic intolerance. PURPOSE: Crewmembers have never become presyncopal in the first 3 min of quiet stand, yet it is unknown whether 3 min is long enough to cause similar heart rate fluctuations to a 5-min stand. The purpose of this study was to validate and test the reliability of heart rate variability (HRV) analysis of a 3-min quiet stand. METHODS: To determine the validity of using 3 vs. 5-min of standing to assess HRV, 7 healthy subjects remained in a prone position for 2 min, stood up quickly and stood quietly for 6 min. ECG and continuous blood pressure data were recorded. Mean R-R interval and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the complete FTT on separate days, including the RFST with a 3-min stand test. Analysis of variance (ANOVA) was performed on the HRV measures. RESULTS: Spectral HRV measures reflecting autonomic activity were not different (p>0.05) during the 0-3 and 0-5 min segment (mean R-R interval: 738+/-74 ms, 728+/-69 ms; low frequency to high frequency ratio: 6.5+/-2.2, 7.7+/-2.7; normalized high frequency: 0.19+/-0.03, 0.18+/-0.04). The average coefficient of variation for mean R-R interval, systolic and diastolic blood pressures in the prone position and stand test were less than 8% for the test sessions. ANOVA results yielded a greater inter-subject variability (p.0.006) than inter-session variability (p>0.05) for HRV in the stand test. CONCLUSION: These studies show that a 3 minute stand delivers repeatable cardiovascular heart rate and BP data in the context of this larger series of tests such as the FTT.

Arzeno, N. M.

Environmental Data Recorder (EDR) qualification

Qualification testing of the environmental data recorder (EDR) was successfully completed. The purpose of this test was to qualify the EDR so that it could monitor segments shipped via railcar from Utah to Kennedy Space Center (KSC). The tests consisted of a transportation and a functional test. The transportation test verified EDR operation in its intended environment. The functional test verified EDR accuracy. Data from the functional test showed that the EDR accuracies complied with requirements. Since the EDR meets or exceeds all of its test objectives, it was successfully qualified. It is recommended that the EDR replace the transportation monitoring unit (TMU). A description of the qualification procedure is presented.

Danforth, Richard A.

Comparing the effectiveness of software testing strategies

This study compares the results of code reading, functional testing, and structural testing in three aspects of software testing: fault detection effectiveness, fault detection cost, and classes of faults detected. Thirty two professional programmers and 42 advanced students applied the three techniques to four unit-sized programs in a fractional experimental design. The major results of this study are the following: (1) With the professional programmers, code reading detected more software faults and had a higher detection rate than did functional or structural testing, while functional testing detected more faults than did structural testing, but functional and structural testing were not different in fault detection rate. (2) In one advanced student subject group, code reading and functional testing were not different in faults found, but were superior to structural testing, while in the other advanced student subject group there was no difference among the techniques. (3) With the advanced student subjects, the three techniques were not different in fault deteciton rate. (4) Number of faults observed, fault detection rate, and total effort in detection depended on the type of software tested. (5) Code reading detected more interface faults than did the other methods. (6) Functional testing detected more control faults than did the other methods. (7) When asked to estimate the percentage of faults detected, code readers gave the most accurate estimates while functional testers gave the least accurate estimates. Appendix B includes the source code for the word.

Basili, Victor R.

Validation of Cardiovascular Parameters during NASA's Functional Task Test

Microgravity exposure causes physiological deconditioning and impairs crewmember task performance. The Functional Task Test (FTT) is designed to correlate these physiological changes to performance in a series of operationally-relevant tasks. One of these, the Recovery from Fall/Stand Test (RFST), tests both the ability to recover from a prone position and cardiovascular responses to orthostasis. PURPOSE: Three minutes were chosen for the duration of this test, yet it is unknown if this is long enough to induce cardiovascular responses similar to the operational 5 min stand test. The purpose of this study was to determine the validity and reliability of heart rate variability (HRV) analysis of a 3 min stand and to examine the effect of spaceflight on these measures. METHODS: To determine the validity of using 3 vs. 5 min of standing to assess HRV, ECG was collected from 7 healthy subjects who participated in a 6 min RFST. Mean R-R interval (RR) and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the FTT on separate days, including the RFST with a 3 min stand. Analysis of variance (ANOVA) was performed on the HRV measures. One crewmember completed the FTT before a 14-day mission, on landing day (R+0) and one (R+1) day after returning to Earth. RESULTS VALIDITY: HRV measures reflecting autonomic activity were not significantly different during the 0-3 and 0-5 min segments. RELIABILITY: The average coefficient of variation for RR, systolic (SBP) and diastolic blood pressures during the RFST were less than 8% for the 3 sessions. ANOVA results yielded a greater inter-subject variability (p<0.006) than inter-session variability (p>0.05) for HRV in the RFST. SPACEFLIGHT: Lower RR and higher SBP were observed on R+0 in rest and stand. On R+1, both RR and SBP trended towards preflight rest and stand values. Postflight HRV showed higher LF/HF for rest and stand and lower HFnu during rest. CONCLUSION: These studies show that a 3 min stand delivers repeatable HRV data in the context of this larger series of FTT tests. Spaceflight-induced changes in blood pressure, RR and autonomic function (HRV) are evident from the RFST.

Arzeno, N. M.