At least 73 records · Page 4

Compact, directional neutron detectors capable of high-resolution nuclear recoil imaging

We report on the design, production, and performance of compact 40-cm3 Time Projection Chambers (TPCs) that detect fast neutrons by measuring the three-dimensional (3D) ionization distribution of nuclear recoils in 4 He:CO 2 gas at atmospheric pressure. We use these detectors to characterize the fast-neutron flux inside the Belle II detector at the SuperKEKB electron–positron collider in Tsukuba, Japan, where the primary design constraint is a small form factor. We find that the TPCs meet or exceed all design specifications, and are capable of measuring the 3D surface shape and charge density profile of ionization clouds from nuclear recoils and charged tracks in exquisite detail. Scaled-up detectors based on the detection principle demonstrated here may be suitable for directional dark matter searches, measurements of coherent neutrino–nucleus scattering, and other experiments requiring precise detection of neutrons or nuclear recoils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A Deployable Fast-Neutron Coded-Aperture Imager for Quantifying Nuclear Material

This brief report describes a newly constructed fast-neutron coded-aperture imager intended for performing quantitative measurements of plutonium holdup at fuel cycle facilities. The present report was prepared in fulfillment of milestone M4FT-13OR0402053, “Construct Imager,” of Fuel Cycle R&D Material Protection, Accounting, and Control Technology (MPACT) work package FT-13OR040205, “Fast-Neutron Imaging to Quantify Nuclear Materials - ORNL.” The first measurements taken with the imager will be reported later this year. For quantifying plutonium holdup, fast-neutron imaging is an appealing mode of measurement in scenarios where contact measurements with non-imaging detectors may be impractical or their results ambiguous because of surrounding material or nearby sources. The use of fast neutrons (as opposed to the more numerous gamma rays) is appealing because of their ability to penetrate equipment and nuclear material that is opaque to gamma radiation. However, the ability of fast neutrons to penetrate material also leads to challenges in constructing a fast-neutron imager sufficiently compact to be amenable for use in a facility while remaining sufficiently sensitive to neutron emanations from plutonium or other actinides. Furthermore, while fast-neutron detection is commonly achieved via organic liquid scintillators, use of the imager in a production environment favors mechanically robust detectors that do not contain flammable liquid. In response to these challenges, Oak Ridge National Laboratory (ORNL) has built a fast-neutron imager that has a compact footprint and whose segmented neutron detectors are built from the first cast plate of the recently developed plastic scintillator with pulse shape discrimination properties developed by Lawrence Livermore National Laboratory and commercially available from Eljen Technologies as experimental scintillator EJ-299-34.

Hausladen, Paul↗

Method for registration of solar cosmic rays by detecting neutrons

We consider a method of detecting the ionizing component of solar cosmic rays (SCRs) with energy from tens of MeV to tens of GeV by measuring the energy loss of SCR protons and light nuclei in scintillators and the multiplicity of the local neutron generation in a converter. Scintillation detectors based on stilbene, lithium glass, and solid-state photomultiplier tubes are capable of detecting fast neutrons with a temporal resolution of 10 ns and rejecting the gamma-ray background in the measuring system. The method will allow investigating the nucleon components of primary SCRs in circumterrestrial space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An event-triggered coincidence algorithm for fast-neutron multiplicity assay corrected for cross-talk and photon breakthrough

Here, a model quantifying detector cross-talk and the misidentification of events in fast neutron coincidence distributions is described. This is demonstrated for two experimental arrangements comprising rings of 8 and 15 organic liquid scintillation detectors. Correction terms developed as part of this model are tested with 252 Cf and a relationship is developed between the 235 U enrichment of U 3 O 8 and the order of correlated, fast neutron multiplets induced by an americium–lithium source. The model is also supported by Geant4 simulations. The results suggest that a typical assay, for experimental arrangements that are similar to the examples investigated in this research, will exhibit cross-talk for less than 1% of all detected fast neutrons but, if not accounted for, this can bias the numerical analysis by a margin of 10% and 35% in second- and third-order coincidences (i.e. couplet and triplet counts), respectively. Further, for the case of 252 Cf, it is shown that a relatively low proportion of 4% breakthrough by rays (that is, photons misidentified as neutrons by the pulse-shape discrimination process) can lead to an erroneous increase of 20% in total neutron counts in the assay of a mixed-field, in this case of 252 Cf. These findings will help direct the developments needed to enable organic scintillation detectors with pulse shape discriminators to be applied reliably to nuclear safeguards and non-proliferation verification tasks.

42 ENGINEERING↗

The Deployable Fast-Neutron Coded-Aperture Imager: Demonstration of Locating One or More Sources in Three Dimensions

This brief report describes commissioning measurements performed using a newly constructed fast neutron coded-aperture imager intended for performing quantitative measurements of plutonium holdup at fuel cycle facilities. The present report was prepared in fulfillment of milestone M3FT-13OR0402054, “Imager commissioning and 3D source configuration measurements” of Fuel Cycle R&D Material Protection, Accounting, and Control Technology (MPACT) work package FT-13OR040205, “Fast Neutron Imaging to Quantify Nuclear Materials - ORNL.” In addition to representing the first measurements made with the new device, these measurements also demonstrate for the first time the ability to localize one or more neutron sources in three dimensions by combining imaging data from multiple measurements in which the imager was positioned at different locations. The development and use of fast-neutron imaging technology are motivated by a desire to locate and quantify plutonium holdup in scenarios where contact measurements with non-imaging detectors may be impractical or their results ambiguous because of surrounding material or nearby sources. Considering the goal of quantitative measurements, fast neutrons (as opposed to the more numerous gamma rays) are preferred in many situations because of their ability to penetrate equipment and nuclear material that are essentially opaque to gamma radiation. However, there are many challenges associated with constructing a practical imager for fast neutrons. For example, the ability of fast neutrons to penetrate material also leads to challenges in constructing a fast-neutron imager that is sufficiently compact to be suitable for use in a facility while remaining sufficiently sensitive to neutron emanations from plutonium or other actinides. Moreover, use of the imager in a production environment favors mechanically robust detectors that do not contain flammable liquid, unlike the organic liquid scintillators that are typically used to achieve fast-neutron detection. Last of all, a single-sided measurement geometry, as is typically used in imaging applications, necessitates accurate measurement of the location of a deposit of plutonium holdup in three dimensions in order to correctly infer the source strength. In response to these challenges, Oak Ridge National Laboratory (ORNL) has built a fast-neutron imager that has a compact footprint and whose segmented neutron detectors are built from the first cast plate of the recently developed plastic scintillator with pulse shape discrimination properties developed by Lawrence Livermore National Laboratory and commercially available from Eljen Technologies as experimental scintillator EJ-299-34. This report presents a description and preliminary analysis of mock holdup measurements intended to determine the three-dimensional location of one or more neutron sources placed in prototypical equipment from a set of imaging measurements that scanned the extent of the equipment.

Hausladen, Paul↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Reflected Neutron Effects in Multiplicity Measurements of Bare HEU Assemblies

In a passive multiplicity characterization of highly enriched uranium (HEU) assemblies, fission chains are initiated by the characteristically fast neutrons from spontaneous fission of 238 U and 235 U as well as cosmic-ray spallation neutrons. Active interrogation of HEU uses other physical mechanisms for starting chains by inducing fission from high-energy neutrons, high-energy gamma-rays, delayed neutrons, or thermal neutrons. In all cases a contribution to the initiation of fission chains is the reflection of neutrons that initially escape the assembly and re-enter it after undergoing some scattering. The reflected neutron flux is geometry dependent and a combination of fast and thermal energies. The reflected thermal neutron contribution occurs hundreds of microseconds after the beginning of the fission chain and can be distinguished from the cosmic-ray spallation neutrons unrelated to fission chains, resulting in an HEU detection signature with high signal-to-noise. However, the reflected thermal neutron flux can be eliminated with an efficient thermal neutron absorber to investigate reflected neutron effects. In this paper, active and passive multiplicity measurements with HEU oxide assemblies of up to 16 kg of fuel pins and HEU metal assemblies of up to five 18 kg storage castings are reported. Each case demonstrates the differences in HEU signature when a borated thermal neutron absorber is present and shows the various detectable signatures with 3He proportional counters, the standard detector for differential die-way and neutron multiplicity measurements, and liquid scintillators, a detector capable of operating on the timescale of fission chains.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Cerium-Based Metal-Organic Scintillators for Radiation Detection

We have previously shown that a new class of scintillating materials can be developed based on the synthesis and crystal growth of rare-earth metal-organic compounds. The first scintillator of this type consisted of single crystals of CeCl3(CH3OH)4 that were grown from a methanol solution. These crystals were shown to be applicable to both gamma-ray and fast neutron detection. Subsequently, metal-organic scintillators consisting of the compound LaBr3(CH3OH)4 activated with varying levels of Ce3+ and of CeBr3(CH3OH)4 were grown in single crystal form. We have now extended the development of this new class of scintillators to more complex organic components by reacting rare-earth halides such as CeCl3 or CeBr3 with different isomers of propanol and butanol including 1-propanol, isobutanol, n-butanol, and tert-butanol. The reaction of CeCl3 or CeBr3 with these organics results in the formation of new and relatively complex molecular crystals whose structures were determined using single-crystal X-ray diffraction. These new metal-organic scintillating materials were grown in single crystal form from solution, and their scintillation characteristics have been investigated using X-ray-excited luminescence plus energy spectra obtained with gamma-ray and alpha-particle sources. If the reactions between the inorganic and organic components are not carried out under very dry and highly controlled conditions, molecular structures can be formed that incorporate waters of hydration. The present observation of scintillation in these hydrated rare-earth metal-organic compounds is apparently an original finding, since we are not aware of any previous reports of scintillation being observed in a material that incorporates waters of hydration

Metal organics↗

Evaluation of neutron light output response functions in EJ-309 organic scintillators

An accurate model of the nonlinear detector response of organic scintillators to neutrons is required to correctly simulate fast neutron detection, as well as interpret measured pulse height data. Several empirical and semi-empirical models are available to fit measured scintillator light output data. In this work, EJ-309 light output data from neutrons depositing 1.15–5.15 MeV on hydrogen were analyzed using empirical models as well as semi-empirical models based on the work of Birks and Voltz. Although all tested models fit the experimental light output data well in the measured range, the models were observed to diverge in low-energy extrapolation. The models were then tested by comparing a measurement and MCNPX-PoliMi simulation of an EJ-309 detector response to fast neutrons from a 252 Cf spontaneous fission source. The agreement between the measured and simulated pulse height distributions varied significantly depending on the light output model used. The best agreement between simulated and measured neutron pulse height distributions was achieved by using the Birks model. The bin-by-bin agreement was better than 5% over the range 0.08–2.18 MeVee, and better than 10% from 2.18 to 3.13 MeVee. Furthermore, the integral count rate over the range 0.08–3.14 MeVee differed by less than 1% in absolute units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance stability of plastics for neutron-gamma pulse shape discrimination

The introduction of the first commercially available plastic scintillators with pulse shape discrimination (PSD) offered by Eljen Technology marked progress towards potentially replacing liquid scintillators in neutron detection. However, use of these plastics over several recent years has revealed an important flaw in these materials: the eventual degradation of scintillation light output and PSD performance. Here, studies described in this paper considered possible reasons for this degradation. Experiments conducted with numerous lab-prepared and commercial EJ-276 samples showed that the main factor affecting the instability is oxidation that involves highly reactive radicals generated during the polymerization process or from the further breakdown of polymer chains under oxygen/air exposure. Based on the obtained results, the stability of scintillation performance for PPO (2,5-Diphenyloxazole)-based PSD plastics has been improved through modifications of the composition via the utilization of scintillation dyes and compounds with antioxidant properties that diminish the effects of oxidation. Elements of these studies were used in the commercial production of the most recent EJ-276D PSD plastic version for fast neutron detection and 6Li-loaded plastics for thermal neutron and antineutrino detection applications. Performance projections of the new PSD plastics indicate a likely degradation of less than 10 % over 5–10 years in comparison to previous EJ-276 that might lose up to 30–40 % of the scintillation light during 1–2 years of storage or deployment under ambient conditions.

36 MATERIALS SCIENCE↗

Nuclear recoil scintillation linearity of a high pressure 4 He gas detector

We investigate scintillation linearity of a commercial high pressure 4 He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Monte Carlo simulations were compared to experimental data to determine the linearity of the detector response by comparing the scaling of the energy deposits in the simulations to the detector output. In this analysis, a linear scintillation response corresponds to a consistent value for the scaling factor between simulated energy deposits and experimental data for several different scattering angles. Here we demonstrate that the detector can be used to detect fast neutron interactions down to 83 keV recoil energies and can be used to characterize low-energy neutron sources, one of its potential applications.

47 OTHER INSTRUMENTATION↗

SU-E-T-239: Design and Evaluation of a Nozzle Shielding System in Passively Scattered Proton Therapy

Purpose: To design, implement and evaluate a shielding system that will reduce out-of-field dose experienced by the patient and associated electronic systems in passively scattered proton therapy treatment. Methods: A multi-stage neutron shielding system was retrofitted to the Gantry 1 treatment nozzle at Loma Linda University Medical Center. The system uses multiple borated polyethylene plates staged after the primary beam modifying devices to attenuate and absorb neutrons produced by such devices. This arrangement locates increasing levels of shielding between the sources of secondary particles in the nozzle and the patient. Additionally, the design of this shielding structure allows it to be easily retrofitted to an existing proton nozzle system without impacting design or treatment beam characteristics. The effectiveness of the shielding was evaluated both through experimental measurements and Geant4 Monte Carlo simulations. Results: Measurements were completed with Landauer Luxel+ dosimeters that use optically stimulated luminescence and CR-39 to detect fast neutrons, thermal neutrons, protons, photons and beta particles. Measurements of a 250 MeV proton beam indicated that the shielding system reduced out-of-field dose to the patient by almost half with dose equivalent values at 50 and 40 cm from the field edge decreasing from 0.965 and 1.262 mSv/Gy to 0.596 and 0.777 mSv/Gy respectively. The installation of the multi-stage shielding system also reduced dose equivalent experienced by electronic systems installed in the treatment room by up to 80%. Geant4 simulations were also used to evaluate the neutron fluence at various positions in the treatment room as well as provide information on microdosimetry spectra within the patient and treatment room. Conclusion: The shielding system described above proved to be an effective an inexpensive method of reducing out-of-field doses to the patient and electronic systems and can be easily retrofitted to existing passive scattering nozzles.

60 APPLIED LIFE SCIENCES↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Expansion of the Fast Neutron Hodoscope at TREAT to Support Fuel Safety Experiments

In 2024 the Fuel Motion Monitoring System (FMMS), or Hodoscope, at the Transient Reactor Test Facility, is being expanded from 96 viewing channels to 192 viewing channels, effectively doubling the FMMS field of view. Here, this increase in capability will allow the FMMS to support larger scale fuel tests, encompassing height-of-core test devices, test devices with multi-pin fuel assemblies, and test devices with recirculating coolant flow. Work supporting the expansion included refurbishing 96 additional proton recoil scintillator (PRS) detectors, doubling the data acquisition system (DAS) installed architecture, improving time synchronization in the DAS, and new research to measure the PRS detector energy-dependent, fast-neutron detection efficiency. In addition, laboratory activities have produced an improved benchtop testing capability for assessing the DAS, time synchronization, and external start triggering, along with an updated capability to scan PRS detectors to develop a preliminary flat-field normalization prior to deployment to TREAT.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Plastic neutron detectors.

This work demonstrated the feasibility and limitations of semiconducting {pi}-conjugated organic polymers for fast neutron detection via n-p elastic scattering. Charge collection in conjugated polymers in the family of substituted poly(p-phenylene vinylene)s (PPV) was evaluated using band-edge laser and proton beam ionization. These semiconducting materials can have high H/C ratio, wide bandgap, high resistivity and high dielectric strength, allowing high field operation with low leakage current and capacitance noise. The materials can also be solution cast, allowing possible low-cost radiation detector fabrication and scale-up. However, improvements in charge collection efficiency are necessary in order to achieve single particle detection with a reasonable sensitivity. The work examined processing variables, additives and environmental effects. Proton beam exposure was used to verify particle sensitivity and radiation hardness to a total exposure of approximately 1 MRAD. Conductivity exhibited sensitivity to temperature and humidity. The effects of molecular ordering were investigated in stretched films, and FTIR was used to quantify the order in films using the Hermans orientation function. The photoconductive response approximately doubled for stretch-aligned films with the stretch direction parallel to the electric field direction, when compared to as-cast films. The response was decreased when the stretch direction was orthogonal to the electric field. Stretch-aligned films also exhibited a significant sensitivity to the polarization of the laser excitation, whereas drop-cast films showed none, indicating improved mobility along the backbone, but poor {pi}-overlap in the orthogonal direction. Drop-cast composites of PPV with substituted fullerenes showed approximately a two order of magnitude increase in photoresponse, nearly independent of nanoparticle concentration. Interestingly, stretch-aligned composite films showed a substantial decrease in photoresponse with increasing stretch ratio. Other additives examined, including small molecules and cosolvents, did not cause any significant increase in photoresponse. Finally, we discovered an inverse-geometric particle track effect wherein increased track lengths created by tilting the detector off normal incidence resulted in decreased signal collection. This is interpreted as a trap-filling effect, leading to increased carrier mobility along the particle track direction. Estimated collection efficiency along the track direction was near 20 electrons/micron of track length, sufficient for particle counting in 50 micron thick films.

36 MATERIALS SCIENCE↗

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.