DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decentralized Microgrid Protection Through Relative Fault Direction Classification: Preprint

Protection in inverter-based resources (IBRs) dominated microgrids generally face significant challenges due to the low fault current and inconsistent fault behaviors from IBRs. Recently, machine learning-based approaches have attracted considerable attention to address these challenges. This paper introduces a novel decentralized protection strategy for microgrids. The proposed method decomposes the protection challenge into several distributed learning tasks, enabling individual relays to autonomously determine the direction of faults using a binary classification framework based on support vector machine (SVM) algorithms. Following the distributed fault direction estimation, classifier outcomes are shared among neighboring relays, facilitating a local decision-making process to ascertain the presence of faults within the neighborhood. Finally, a tripping signal is generated based on the classifier results of each relay to operate the circuit breaker. To test and validate this approach, a 100% renewable microgrid model is simulated in MATLAB/Simulink. In the numerical analysis, the application of SVM classifiers in our approach yields impressive results: an average relay classification accuracy of 98%, and a 96% accuracy in circuit breaker control. These findings highlight the potential of machine-learning-based approaches in enhancing the efficiency and reliability of microgrid protection systems.

decentralized algorithm↗

Atomic Structural Features of Stacking Faults and Domain Connections in the Li- and Mn-Rich Cathode

Li- and Mn-rich layered oxides (LMRs), a class of earth-abundant materials for rechargeable Li-ion battery cathodes, crystallize into layered structures of two different symmetries: C2/m represented by Li 2 MnO 3 and R$\overline{3}$m represented by LiMn 0.5 Ni 0.5 O 2 . Fundamental questions about how the C2/m and R$\overline{3}$m domains spatially correlate within the same oxide grain and how the C2/m stacking faults arrange themselves when this happens still remain. Here, by using integrated differential phase contrast imaging in scanning transmission electron microscopy (STEM-iDPC), we probe the structural and compositional details of a prototypical, cobalt-free LMR material, 0.3Li 2 MnO 3 •0.7LiMn 0.5 Ni 0.5 O 2 (Li 1.13 Mn 0.57 Ni 0.3 O 2 ). The connection between the C2/m and R$\overline{3}$m domains is found to be abrupt, facilitated by the small lattice mismatch between the two structures. Stacking faults in the C2/m domains feature atomic plane shifting that accommodates stacking sequence changes, which explains why the stacking faults form in a random manner. Furthermore, a local disordering mechanism was identified to correlate with the C2/m stacking faults. Chemically, it is found that Ni coexists with Mn at the transition metal sites within the nominal Li 2 MnO 3 domain. As a result, this study demonstrates that STEM-iDPC is a very useful tool for capturing all the elements in a single image, revealing atomic details on domain connections and stacking faults in the LMRs.

Li-rich and Mn-rich oxides↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)↗

Early Fault Detection in Nuclear Systems: A Digital Engineering Approach

Nuclear energy systems present unique challenges in terms of ensuring safety, reliability, and efficiency during their design and operation. Early fault detection is critical for mitigating risks and fostering system resilience. However, current methods often fall short at identifying faults during early stages, potentially leading to costly delays and safety risks. The present work proposes a comprehensive digital engineering approach that leverages digital twins, digital threads, model-based systems engineering, artificial intelligence, and immersive extended reality to support early fault detection in nuclear systems. Through a series of case studies, we highlight specific gaps in the fault detection mechanisms of traditional nuclear design and operation processes, then demonstrate a suite of solutions we are working to implement to address these shortcomings in similar projects. Our findings suggest that a digital engineering approach to design and operation can significantly improve fault detection, ultimately leading to reductions in risk.

42 - ENGINEERING↗

Activating a Natural Fault Zone in the Swiss Alps

One major hurdle for understanding earthquake mechanics are observational limitations. Important phenomena like strain localisation, fault dilation, and fault healing are readily studied in rock mechanical laboratory experiments and with numerical models. At the scale of natural earthquakes, however, these phenomena are often unresolvable, even by state-of-the-art observatories. To overcome this limitation, we are currently building the Earthquake Physics Testbed at the Bedretto Underground Laboratory for Geosciences and Geoenergies (BedrettoLab), an experimental testbed where we can activate an extensively instrumented natural fault zone via hydraulic stimulation. The goal of the Fault Activation and Earthquake Rupture (FEAR) project is to induce earthquakes of up to Mw~1.0 on this exceptionally well characterised and instrumented fault zone. Here we summarize the main scientific goals and current FEAR project status, and present first results from conducted experiments. We discuss how this large-scale experimental approach may allow us to tackle both fundamental science as well as practical questions on earthquake physics, induced seismicity and seismic hazard.

Meier, Men-Andrin↗

A Systematic Framework for Tuning Open-Source Multifunctional IBR Models To Emulate OEM Black-Box Fault Dynamics

This paper presents a systematic framework to tune a generic IBR EMT model to match with an OEM provided balckbox inverter model based on the fault current responses. The key learnings and findings are summarized as follows: The tunable key parameters include inner control loops and current limiters to align the fault current magnitude, sequence content, and phase trajectories with the OEM models across diverse fault type and locations. The tuned model's fidelity is validated through comparative analysis with an OEM blackbox model, assessing both the fault current response and the responses of multiple relay elements. The results demonstrate the tuned generic model can trigger relay decision logic that is identical or near identical to that of the OEM model, thus generating very good match model for fault studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine learning for photovoltaic single axis tracker fault detection and classification

More than 81% of the annual capacity of utility-scale photovoltaic (PV) power plants in the U.S. use single-axis trackers (SATs) due to SATs delivering 4% in capacity factor on average over fixed-array systems. However, SATs are subject to faults, such as software misconfigurations and mechanical failures, resulting in suboptimal tracking. If left undetected, the overall power yield of the PV power plant is reduced significantly. Minimizing downtime and ensuring efficient operation of SATs requires robust detection and diagnosis mechanisms for SAT faults. We present a machine learning framework for implementing real-time SAT fault detection and classification. Our implementation of the proposed framework reliably identifies measurements taken from a test PV system undergoing emulated SAT faults relative to state-of-the-art algorithms and produces nearly zero false positives on our testing days. Code and data are available at https://pvpmc.sandia.gov/tools.

Fault classification↗

Behavior of Single-Line-Ground Faults in Inverter-Based Resource Dominated Grids Explained

It has been observed by protection engineers that it is difficult for a protective relay to identify the faulted phase during a single-line-ground (SLG) fault in a power system with a high ingression of inverter-based resources (IBR) using currents (phase or sequence). Further studies using electromagnetic transient (EMT) simulation show that the initial operating conditions of the IBRs influence the response of phase currents during an SLG fault. In this letter, we conduct a quantitative analysis using sequence components. We find that the pre-fault condition determines the relative position of the current contributed by the grid versus that from the IBR, and further dictates which phase has the largest magnitude during an SLG condition. Finally, this finding is further verified by the EMT simulation results.

electromagnetic transient simulation↗

Active multi-mode data analysis to improve fault diagnosis in AHUs

Faults in heating, ventilation and air conditioning systems can lead to increased energy consumption, occupant comfort issues, and reduced equipment lifetime. Commercial fault detection and diagnosis (FDD) tools has been increasingly deployed in U.S. commercial buildings. While they are helping to achieve energy efficiency and operational reliability, there remain gaps in their fault diagnostic capabilities. The diagnostic results often contain multiple distinct candidate root causes (CRCs) or offer no insight into CRCs. This study developed a novel active rule-based multi-mode data analysis method to enhance diagnostic resolution by applying proven rule sets and additional new rules to data from multiple known operational modes. The proposed method was demonstrated using enhanced air handling unit performance assessment rule sets and validated with the simulated data of two air handling units. New metrics, namely, reduced number of CRCs and improvement ratio, were developed to quantify the improvement of fault diagnostic resolution. The validation results showed that the proposed method effectively reduced the number of CRCs in contrast to analyzing data solely for a single mode of operation. It achieved a median improvement ratio of 80% in 19 test cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformational faulting in Mn 2 GeO 4 from olivine to wadsleyite structure: Implications for physical mechanism of deep-focus earthquakes

High-pressure and temperature deformation experiments interfaced with acoustic emission (AE) monitoring have been conducted to study transformational faulting in Mn 2 GeO 4 olivine, which transforms to the β phase, isostructural to wadsleyite. Metastable Mn 2 GeO 4 olivine exhibits a marked embrittlement behavior at temperatures between 800 and 1100 K, emitting numerous AEs. At each temperature, brittle deformation is characterized by a two-stage process: (1) a “preparation” stage with numerous diffusedly located low-magnitude AEs and large b values (>2), and (2) a failure stage where larger-magnitude AEs form a planar distribution with b values about 1. Microstructure analysis reveals extensive kink band development in olivine grains in the recovered samples. Kink band boundaries (KBBs), with a typical thickness of ∼100 nm, are filled with a nanometric β-Mn 2 GeO 4 “gouge”. A dense array of secondary shear localizations is often present within the kink bands, suggesting significant shear deformation therein. The combined observations suggest that faulting in metastable Mn 2 GeO 4 olivine is a self-similar process, from grain-scale to the sample-scale. Both observed embrittlement behavior and the microstructure of metastable Mn 2 GeO 4 olivine are essentially identical to those in Mg 2 GeO 4 olivine we have reported previously, indicating that the physical mechanism of faulting in metastable olivine is insensitive to the specific crystallographic structure of the high-pressure phase. The low b values (about 1) observed in the faulting process in our experiments are similar to those of deep focus earthquakes in cold subduction zones. Our observed mechanism explains deep focus seismicity in cold metastable mantle wedges, provided that the self-similarity assumption holds to geological scales.

58 GEOSCIENCES↗

PyFaults: A Python Toolkit for Stacking Fault Screening

PyFaults is an open-source Python library designed to model stacking fault disorder in crystalline materials and qualitatively assess the characteristic selective broadening effects in powder X-ray diffraction (PXRD). Here, the main capabilities of PyFaults are presented, including unit cell and supercell model construction, PXRD pattern calculation, assessment against experimental PXRD, and methods for rapid screening of candidate models within a set of possible stacking vectors and fault occurrence probabilities. This program aims to serve as a computationally inexpensive tool for identifying and screening potential stacking fault models in materials with planar disorder. Three diverse case studies, involving GaN, Li2MnO3 and Li3YCl6, are presented to illustrate the program functionality across a range of structure types and stacking fault modalities.

MATHEMATICS AND COMPUTING↗

A Field and Laboratory Study to Characterize Fault Prevalence in Residential Comfort Systems

This report describes a project whose goal was to determine the prevalence of residential comfort system faults. The focus is on air conditioners and heat pumps, and on key faults that can occur during installation and have significant impacts on performance: (1) incorrect refrigerant charge level (undercharge or overcharge); (2) indoor coil airflow rate; (3) liquid line restrictions; (4) non-condensable gas in the refrigerant; and (5) duct leakage. In addition to quantifying fault prevalence, we collected metadata that could be studied to determine whether there are correlations that suggest drivers of fault prevalence, such as regional variations in practice, economic factors, climatic impacts, and others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stacking fault analysis for the early-stages of PVT growth of 4H-SiC crystals

Here, four types of stacking fault formation mechanisms are identified and discussed for early stage PVT growth of 4H-SiC crystals: Type 1: Shockley / double Shockley stacking fault formation inside the facet; Type 2: Stacking fault formation via 2D nucleation; Type 3: Frank + Shockley (S) stacking fault formation due to deflection of threading mixed dislocation (TMD) by macrosteps; Type 4: “Carrot” defect formation related to overgrowth of the terrace formed by separation of 3c/4 and c/4 step risers after deflection of a TMD by vicinal steps. The results help further reduction of defect generation in 4H-SiC substrates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stress Field Dynamics and Fault Slip Potential in the Paradox Basin

Abstract The Paradox Basin, straddling Utah, Colorado, Arizona, and New Mexico is characterized by an intricate amalgamation of evaporites and clastic layers and is dominated by prominent salt walls and related subsurface structures. Our research offers a new examination of the stress distribution across the basin, deriving from continuous and discrete stress measurements conducted in boreholes in the region and focal mechanism analysis, emphasizing variations over salt structures. Integrating Coulomb failure criteria with probabilistic methods, we assess potential fault movements resulting from fluid pressure alterations. Our approach provides a comprehensive understanding of the Paradox Basin's state of stress, showing a continuous change of the maximum horizontal stress orientation from N‐S at the Wasatch Fault Zone to WNW‐ESE in the northern part of the Paradox Basin and to WSW‐ENE in the southern part of the basin. Further East, into the Colorado Plateau and the Uncompahgre Uplift, the S H max orientation becomes E‐W. Decoding stress orientation dynamics has enabled critical insights into fault slip potential, especially in the basin's northern region. The salt wall faults are less likely to slip, and the Paradox Formation's evaporite and clastic rock sequence can serve as a potential low seismic risk target for carbon storage and hydrocarbon extraction.

Geochemistry & Geophysics↗

Fault-tolerant operation and materials science with neutral atom logical qubits

We report on the fault-tolerant operation of logical qubits on a neutral atom quantum computer, with logical performance surpassing physical performance for multiple circuits including Bell state preparation (12x error reduction), random circuits (15x), and a prototype Anderson Impurity Model ground state solver for materials science applications (up to 6x, non-fault-tolerantly). The logical qubits are implemented via the [[4, 2, 2]] code (C 4 ). Our work constitutes the first complete realization of the benchmarking protocol proposed by Gottesman 2016 demonstrating results consistent with fault tolerance. In light of recent advances on applying concatenated C 4 /C 6 detection codes to achieve error correction with high code rates and thresholds, our work can be regarded as a building block towards a practical scheme for fault tolerant quantum computation. Our demonstration of a materials science application with logical qubits particularly demonstrates the immediate value of these techniques on current experiments.

36 MATERIALS SCIENCE↗

Travelling wave‐based fault detection and location in a real low‐voltage DC microgrid

Abstract This paper discusses a device‐level implementation of a travelling wave (TW) protection device (PD) designed for a real low‐voltage DC microgrid. The TWPD fault detection and location algorithm is executed on a commercial digital signal processor (DSP) board, involving signal sampling at 1 MHz via the DSP board's analog‐to‐digital converter (ADC). The analogue input card measures positive pole, negative pole and pole‐to‐pole voltages at the TWPD location. Upon a successful fault detection using a second‐order high‐pass filter, the voltage data is normalised and multi‐resolution analysis (MRA) is performed on a 128‐sample buffer around the TW arrival time. MRA employs the discrete wavelet transform (DWT) to capture high‐frequency voltage patterns, and then the Parseval's energy theorem quantifies these TW characteristics by computing the energy of reconstructed wavelet coefficients. These energy values per decomposed frequency band are the basis for training a random forest classifier that predicts fault location and type. The TWPD is fully implemented and connected to a real DC microgrid in Albuquerque, NM, USA, for validation, and results are shown for field tests verifying the performance under faults.

Paruthiyil, Sajay Krishnan [Department of Electric↗