Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Thermochemical characterization of intumescent materials and their application in FEM models using Aria

Intumescent materials are in wide use as protective coatings in fire protection or thermal management applications. These materials undergo chemical reactions occurring from approximately 300°C to 900°C, which outgas and expand the material, providing an appreciable increase in insulative performance. However, the complicated chemical mechanisms and large changes in materials properties complicate the incorporation of these materials into predictive thermal models. This document serves to outline the thermochemical characterization of select intumescent materials, the extraction of relevant parameters, and the incorporation of these parameters into the ChemEQ reaction model implemented in Aria. This work was performed in 2016 and documented in a draft SAND report in March 2017. In 2022, the draft SAND report was discovered and put through R&A.

36 MATERIALS SCIENCE↗

Emergency Response Capability Baseline Needs Assessment - Compliance Assessment

This document was prepared by John A. Sharry, LLNL Fire Marshal and Division Leader for Fire Protection and was reviewed by LLNL Emergency Management Department Head, James Colson. This document is the second of a two-part analysis on Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2016 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2016 BNA, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures. The 2013 BNA was approved by NNSA’s Livermore Field Office on January 22, 2014.

99 GENERAL AND MISCELLANEOUS↗

Effects of Irradiation on Thermal Properties of Polyurethane Foam

Polyurethane foam is used as a thermal insulator, fire protective material, and impact absorber in the 9977 shipping package. The 9977 shipping package is used to transport special nuclear materials (SNM), and store SNM in the K-area complex at the Savannah River Site. The primary fire-retardant mechanism in the foam is that it produces intumescent char when exposed to high temperatures. Intumescence occurs in the direction of heat application and can allow the foam to “repair” cracks in the event of a mechanical impact, in addition to serving as a secondary thermal barrier with decreased heat conductivity. Because the foam is being used for long-term storage applications, it is vital that it retain its physical, thermal, and mechanical properties over the course of time and with the events of exposure of heat and irradiation. The goal of this project was to determine the effects of gamma irradiation on the thermal properties of polyurethane foam, both in terms of cumulative irradiation and rate of irradiation. At the dose rates and cumulative doses of irradiation measured, there was no correlation between higher cumulative irradiation and thermal stability, specific heat capacity, or chemical structure. Based on the results of the experiments, the fire protective properties in the 9977 shipping containers should be retained with the expected amount of radiation exposure.

36 MATERIALS SCIENCE↗

Airborne Projection of Burning Embers – Planning and Controls for Los Alamos National Laboratory Facilities

As a result of the Las Conchas Fire, the Department of Energy in correspondence SO:32CK 372899 (DOE 2011) requested that LANS take the following action: Evaluate the Las Conchas fire experience and other data on airborne projection of burning embers and the appropriate planning and controls for Los Alamos National Laboratory (LANL) facilities, including nuclear and high hazard facilities. This paper addresses the DOE action by evaluating 1) the meteorology at the time of the accident and implications for new wild land fires; 2) the ability of LANL facilities to withstand fires as a result of burning embers, and 3) LANL programs in place to mitigate the effects of wild land fires. The spread of fire as a result of burning embers is a known and important mechanism. Both empirical and computational studies have been performed, and it is recognized that these studies should continue (Kim 2009, Koo 2010, Sardoy 2007). Due to the locale and environs of LANL, burning brands or embers from forest fires are a credible risk at LANL. With the exception of the Area G TRU Waste Facility, LANL nuclear facilities have fire resistant exteriors with UL Class A roofs. Waste at Area G is stored in fire resistant containers. The laboratory has comprehensive Emergency Operations and Fire Protection Programs, which includes assessing wildland fire risk and mitigating the spread of fires, for example, by maintaining fire breaks and additional defensible buffer areas free of combustibles around LANL facilities and limits on combustible loading. Vegetation is cut-back to at least national consensus standards on a regular basis around nuclear facilities. Fire Department services are provided by Los Alamos County through an agreement with the Department of Energy. The interface between the Fire Department and LANL during emergencies is the Emergency Operations Division. The ability of LANL facilities to withstand a wildland fire was tested by both the Cerro Grande fire in 2000 as well as the Las Conchas fire. No nuclear or high-hazard facilities were damaged even though the Cerro Grande fire burned around a number of the facilities. Since then, the laboratory has strengthened programs to protect against wildland fires.

99 GENERAL AND MISCELLANEOUS↗

NAVIGATING A QUALITY ROUTE TO A NATIONAL SAFETY AWARD

Deming quality methodologies applied to safety are recognized with the National Safety Council's annual Robert W. Campbell Award. Over the last ten years, the implementation of Statistical Process Control and quality methodologies at the U.S. Department of Energy's Hanford Site have contributed to improved safety. Improvements attributed to Statistical Process Control are evidenced in Occupational Safety and Health records and documented through several articles in Quality Progress and the American Society of Safety Engineers publication, Professional Safety. Statistical trending of safety, quality, and occurrence data continues to playa key role in improving safety and quality at what has been called the world's largest environmental cleanup project. DOE's Hanford Site played a pivotal role in the nation's defense beginning in the 1940s, when it was established as part of the Manhattan Project. After more than 50 years of producing material for nuclear weapons, Hanford, which covers 586 square miles in southeastern Washington state, is now focused on three outcomes: (1) Restoring the Columbia River corridor for multiple uses; (2) Transitioning the central plateau to support long-term waste management; and (3) Putting DOE assets to work for the future. The current environmental cleanup mission faces challenges of overlapping technical, political, regulatory, environmental, and cultural interests. From Oct. 1, 1996 through Sept. 30, 2008, Fluor Hanford was a prime contractor to the Department of Energy's Richland Operations Office. In this role, Fluor Hanford managed several major cleanup activities that included dismantling former nuclear-processing facilities, cleaning up the Site's contaminated groundwater, retrieving and processing transuranic waste for shipment and disposal off-site, maintaining the Site's infrastructure, providing security and fire protection, and operating the Volpentest HAMMER Training and Education Center. On October 1,2008, a transition occurred that changed Fluor's role at Hanford. Fluor's work at Hanford was split in two with the technical scope being assumed by the CH2M HILL Plateau Remediation Company (CHPRC) CHPRC is now spearheading much of the cleanup work associated with former nuclear-processing facilities, contaminated groundwater, and transuranic waste. Fluor is an integrated subcontractor to CH PRC in this effort. In addition, at the time of this writing, while the final outcome is being determined for the new Mission Support Contract, Fluor Hanford has had its contract extended to provide site-wide services that include security, fire protection, infrastructure, and operating the HAMMER facility. The emphasis has to be on doing work safely, delivering quality work, controlling costs, and meeting deadlines. Statistical support is provided by Fluor to the PRC, within Fluor Hanford, and to a third contractor, Washington Closure Hanford, which is tasked with cleaning up approximately 210 square miles designated as the Columbia River corridor along the outer edge of the Hanford Site. The closing months of Fluor Hanford's 12 year contract were busy, characterized by special events that capped its work as a prime cleanup contractor, transitions of work scope and personnel, and the completion numerous activities. At this time, Fluor's work and approach to safety were featured in state and national forums. A 'Blockbuster' presentation at the Washington State Governor's Industrial Safety Conference in September 2008 featured Fluor Hanford's Chief Operating Officer, a company Safety Representative, and me. Simultaneously, an award ceremony in Anaheim, Calif. recognized Fluor Hanford as the winner of the 2008 Robert W. Campbell Award. The Robert W. Campbell Award is co-sponsored by Exxon Mobil Corporation and the National Safety Council. Named after a pioneer of industrial safety, the Campbell Award recognizes organizations that demonstrate how integration of environmental, health and safety (EHS) management into business operations is a cornerstone of their corporate success. Fluor Hanford received the award for corporations with more than 1,000 employees. Campbell Award winners undergo rigorous assessments that include site visits and comprehensive evaluations of their commitment to, and implementation of, EHS practices. Award winners work with an international partnership of 21 organizations to develop case studies that illustrate their superior EHS programs and best practices, for use by top business and engineering schools worldwide. Quality methodologies in place at Fluor Hanford played a key role in the award process. Fluor Hanford's integrated use of Statistical Process Control and Pareto Charts for analyzing and displaying EHS performance were viewed favorably by the award judges.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Analysis of Material Properties of Aged Rigid Polyurethane Foam

Foams are classified as either rigid or flexible and are commonly used in applications such as pipe insulation, carpet fibers, and chair foam cushions. Polyurethane foams are excellent thermal insulators, have excellent mechanical properties, and are chemically inert. With the addition of fire protective additives, polyurethane foams have the ability to intumescence when exposed to high temperatures. For the future storage of the 9977 nuclear shipping packages, the material properties of the General Plastics 3716 rigid polyurethane foam were evaluated for long term performance by comparing aged samples to unaged samples. General Plastics 3716 rigid polyurethane foam was aged from November 2014 to June 2019 at varying temperatures of: 160 deg. F, 160 deg. F + 50% relative humidity (RH), 185 deg. F, 215 deg. F, and 250 deg. F. The foam was then analyzed via Fourier Transform Infrared Spectroscopy (FTIR), 3D Optical Microscope, Thermal Gravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC). FTIR and Optical Microscope: No significant change to chemical or physical structure was evident by FTIR or optical microscope analysis. DSC: Decrease of heat capacity over time for all oven temperatures except a slight increase for the 185 deg. F conditioned foams. Largest decrease evident with foams conditioned at 250 deg. F. A slight increase in heat capacity for humid samples. Similar trends in heat capacities at 71 deg. C and 102 deg. C. TGA: As conditioning temperature increased, a decline was evident in the average percent weight loss, onset temperature, and first derivative peak temperature. No significant effect due to humidity except for a decrease in first derivative peak temperature. Unaged samples exhibited strong intumescence. Foams conditioned at 160 deg. F exhibited slight intumescence. Results suggest fire protective additives decomposed at higher temperatures, which contributed to a lower average percent mass loss in higher temperature conditioning. Further thermal degradation testing would be beneficial to evaluate the ability of the conditioned foams to intumesce. Evaluate irradiation dose rate effects on conditioned foam. Possible conditioning in an environment with a known humidity or analyzing a new aliquot of sample for each trial to achieve a more representative heat capacity calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Business Case Analysis of Real Green Building Systems, LLC Technologies

Real Green Building Systems, LLC offers environmentally friendly home designs with five synergistic systems: plumbing-based fire protection, solar thermal heating and domestic hot water, solar electricity, and recycled water. This home design fits with the green construction movement in the United States that has developed to the point where 20 percent of all newly built homes last year were “green,” with an overall $25B market value. The market is expected to grow to between 29% and 38% of new U.S. homes by 2016. Generally, materials and construction costs are somewhat higher (five to ten percent) for green homes, but some localities offer rebates form the state or utility to help offset this. Structural features that are typical include tightly insulated walls to prevent air escape, insulated foundations, and windows designed to capture heat. Other add-on systems include solar or geothermal heating or cooling, and solar electric. A mechanical air exchange system may be needed to ensure good air quality given the tight nature of the house. A green home is desirable to buyers who are looking to save utility bills or reduce dependence on the grid. Often buyers are at or nearing retirement, and such a home can reduce volatility of energy costs long term. Owners may need education on the systems to feel comfortable with the relatively novel active technologies. Passive systems such as thick walls with better insulation need no maintenance or training, and can be quiet, medically safer, and more comfortable. The resale value of a green home appears to be somewhat higher than conventional homes. California data suggest a premium of about nine percent on green home sales prices. One of the key differences in RGBS homes is the fully insulated, fire-protected multi-purpose room instead of a garage. A “garage” in normal houses is not suitable for uses other than storage and parking vehicles. But RGBS designs this area to be conditioned floor space, equivalent to the rest of the home with the only difference being an overhead door. In fact, most home owners do not use a garage to store their car—a recent study showed that about 75 percent of garages are used for other purposes. This is explicitly recognized in the RGBS design, with the conditioned space made fully functional for all uses. A key benefit of this is also that the space can be counted as living space for appraisal purposes, which leads to a lower cost per square foot for the home in addition to increased functionality.

14 SOLAR ENERGY↗

Fire performance, microstructure and thermal degradation of an epoxy based nano intumescent fire retardant coating for structural applications

Intumescent fire retardant coating (IFRC) is a passive fire protection system which swells upon heating to form expanded multi-cellular char layer that protects the substrate from fire. In this research work, IFRC’s were developed using different flame retardants such as ammonium polyphosphate, expandable graphite, melamine and boric acid. These flame retardants were bound together with the help of epoxy binder and cured together using curing agent. IFRC was then reinforced with nano magnesium oxide and nano alumina as inorganic fillers to study their effect towards fire performance, microstructure and thermal degradation. Small scale fire test was conducted to investigate the thermal insulation of coating whereas fire performance was calculated using thermal margin value. Field emission scanning electron microscopy was used to examine the microstructure of char obtained after fire test. Thermogravimetric analysis was conducted to investigate the residual weight of coating. Results showed that the performance of the coating was enhanced by reinforcement with nano size fillers as compared to non-filler based coating. Comparing both nano size magnesium oxide and nano size alumina; nano size alumina gave better fire performance with improved microstructure of char and high residual weight.

36 MATERIALS SCIENCE↗

Validation Assessment of Turbulent Reacting Flow Model Using The Area-Validation Metric on Medium-Scale Methanol Pool Fire Results

Accident analysis and ensuring power plant safety are pivotal in the nuclear energy sector. Significant strides have been achieved over the past few decades regarding fire protection and safety, primarily centered on design and regulatory compliance. Yet, after the Fukushima accident a decade ago, the imperative to enhance measures against fire, internal flooding, and power loss has intensified. Hence, a comprehensive, multilayered protection strategy against severe accidents is needed. Consequently, gaining a deeper insight into pool fires and their behavior through extensive validated data can greatly aid in improving these measures using advanced validation techniques. A model validation study was performed at Sandia National Laboratories in which a 30-cm diameter methanol pool fire was modeled using the SIERRA/Fuego turbulent reacting flow code. This validation study used a standard validation experiment to compare model results against, and conclusions have been published. The fire was modeled with a Large Eddy Simulation (LES) turbulence model with subgrid turbulent kinetic energy closure. Combustion was modeled using a strained laminar flamelet library approach. Radiative heat transfer was accounted for with a model utilizing the gray-gas approximation. In the present study, additional validation analysis is performed using the area validation metric (AVM). These activities are done on multiple datasets involving different variables and temporal/spatial ranges and intervals. In conclusion, the results provide insight into the use of the area validation metric on such temporally varying datasets and the importance of physics-aware use of the metric for proper analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Advanced Borobond™ Shields for Nuclear Materials Containment and Borobond™ Immobilization of Volatile Fission Products - Final CRADA Report

Borobond is a company-proprietary material developed by the CRADA partner in collaboration with Argonne, and is based on Argonne's Ceramicrete technology. It is being used by DOE for nuclear materials safe storage, and Boron Products, LLC is the manufacturer and supplier of Borobond. The major objective of this project was to produce a more versatile composition of this material and find new applications. Major target applications were use for nuclear radiation shields, such as in dry storage casks; use in immobilization of most difficult waste streams, such as Hanford K-Basin waste; use for soluble and volatile fission products, such as Cs, Tc, Sr, and I; and use for corrosion and fire protection applications in nuclear facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovative Advanced Hydrogen Mobile Fueler (Final Technical Report)

The US Department of Energy (DOE) funded a project to design, develop, deploy and analyze the economic viability of an innovative Advanced Hydrogen Mobile Fueler (AHMF). As part of the design activity the project team defined specifications based upon vehicle requirements and compliance with specific fueling performance criteria. The AHMF was originally designed to fuel 10-20 fuel cell vehicles (FCV) per day, consistent with the requirements of the H70 fueling category. The AHMF is able to operate without remote power connections, is modular for easy transport and deployment, and can provide expanded daily capacity and multi-day operations using delivered gaseous hydrogen. Toward the end of the project, due to request from the hydrogen industry and some necessary modifications of the AHMF, the system is now modified to fuel heavy duty vehicles. The project was conducted over two primary phases, each including several key tasks, subtasks, and project milestones. Phase 1 involved the design, development, and construction of the AHMF, moving from a conceptual design through to completion of assembly and testing. In addition to reviewing several different approaches, the team chose to take a conventional station design and modify it for mobile fueling. There were several innovative components included in the design. The high pressure storage was the first to achieve a US Department of Energy (DOE) Special Permit (SP 20391) to transport high pressure hydrogen (95 MPa) in a composite cylinder. The second novel system was a liquid nitrogen (LIN) cooling system with a compact heat exchanger. Without this change, the cooling system would not be able to fit into the AHMF. Phase 2 demonstrated the AHMF by fueling fuel cell buses at a fleet in Pomona, CA. The site was chosen because a temporary fueling solution was required while a fixed station was being installed. The existing permits for the fixed station and non-public access also was a determining factor. Over two months, the buses were fueled 320 times with over 5000 kg of hydrogen from tube trailers. Existing shore power was used, and the average electrical efficiency was 0.13 kWh/kg. The average liquid nitrogen (LIN) consumption was 90.68 scf/kg. The fueling and consumption data was provided to the National Renewable Energy Laboratory (NREL) for analysis. An economic analysis was performed and will be provided in a separate report. The project was successful, but not without challenges and lessons learned. The DOT special permit led the way for the use of high pressure, composite cylinders and is being by multiple other systems and applications. The pandemic along with time for the DOT special permit approval delayed the project for years. The team also believes that hydrogen mobile fueling has a use for the industry, especially during this upcoming phase of expansion. However, it does have its limitations due to high cost to build and operate, and the same permitting challenges as a fixed station. A fully capable system at the speeds and pressures of the AHMF may not be necessary for most applications and would help reduce the cost and increase storage capacity. The on-board generator can be easily replaced with shore power or the wide range of power generation solutions in the marketplace. One of the major results of the project was the development of new code language in National Fire Protection Agency (NFPA) 2 and the International Fire Code (IFC) for on-demand mobile fueling. This will provide guidance for Authorities Having Jurisdiction (AHJ) and user on how to permit temporary fueling sites across the nation.

08 HYDROGEN↗

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY↗

NREL Supports Development of New National Code for Hydrogen Technologies (Fact Sheet)

On December 14, 2010, the National Fire Protection Association (NFPA) issued a new national code for hydrogen technologies - NFPA 2 Hydrogen Technologies Code - which covers critical applications and operations such as hydrogen dispensing, production, and storage. The new code consolidates existing hydrogen-related NFPA codes and standards requirements into a single document and also introducesnew requirements. This consolidation makes it easier for users to prepare code-compliant permit applications and to review/approve these applications. The National Renewable Energy Laboratory helped support the development of NFPA 2 on behalf of the U.S. Department of Energy Fuel Cell Technologies Program.

HYDROGEN↗

DETECTING FIRE WITH MACHINE LEARNING-ENABLED VISUAL MONITORING FOR NUCLEAR POWER PLANT ENVIRONMENTS

Nuclear power plants are experiencing significant cost challenges to remain competitive with other energy-generation utilities. Unlike other industries, the cost of operation and maintenance activities is mostly attributed to workforce costs. To mitigate this, nuclear power plant stakeholders are increasingly interested in the development and deployment of machine learning methods to potentially automate or augment manually intensive tasks to reduce costs, especially for monitoring activities. One monitoring function that is visually demanding and that can occur frequently to meet the requirements of a fire protection program is visually monitoring an area for fire occurrence. Currently, fire watch activities consist of a worker physically stationed at a given location with the sole responsibility of observing a given area to ensure a fire is detected and mitigated promptly. This effort focused on the development and evaluation of a suitable deep convolutional neural network to classify individual video frames at a sub-second frequency for the occurrence of “fire” and “no fire” in varying industrial environments similar to nuclear power plants. It is believed that a trained neural network model could be integrated with existing facility video surveillance camera feeds to generate alerts when fire inferences occur in individual frames captured at sub-second temporal resolutions. Extensive effort was dedicated to identifying and curating suitable imagery training data representing varying environments and scene settings with and without flame features to maximize generalization in nuclear power plant environments. The data collection effort resulted in the aggregation of a large, labeled image library exceeding 12,000 images to support model training for diverse industrial environments. A deep neural network model incorporating parallel multi-scale capabilities was developed and trained to support accurate image-based detection of flame incidents of varying sizes and spectral feature properties within heterogeneous scenes. Analysis results show that the trained model can achieve high inference accuracy despite heterogeneous scene environments and components. Testing accuracy exceeded 95.0 percent with very low false positive and false negative inferences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emergency Response Capability Baseline Needs Assessment Compliance Assessment

This document is the second of a two-part analysis of Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2013 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2009 BNA, the 2012 BNA document, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures.

99 GENERAL AND MISCELLANEOUS↗

Reduction of fire hazards on large mining equipment

Although standards and regulations are in place to prevent large mining equipment fires, recent analyses of mine accident data show that mining equipment fires still occur with alarming frequency and grave consequences, particularly at all surface mines and in underground metal/nonmetal mines. Recently technological advances in fire protection, combined with the statistical data on equipment fires, led NIOSH to reinvestigate this and to improve operator safety. NIOSH demonstrated that newly developed technologies, such as dual cab fire inerting systems and engine compartment fire barriers, can greatly enhance operator safety and lessen the damage of property during large mobile equipment fires. 10 refs., 5 figs.

01 COAL, LIGNITE, AND PEAT↗

The Applications of Intumescent Technologies in Support of D and D Activities across the DOE Complex - 19599

The development of intumescent technologies to be used as both an excellent means of fire protection and resiliency and as a radioactive fixative, would most definitely benefit the safety of the general public and also the environment. The remediation and safe disposal of radioactive waste is of great important to both national security and the public health, as we carry the responsibility to not develop new ways of mitigating these hazards but also to lay the groundwork for future generations. The overall goal of this research is to enhance the fire resiliency and protection of fixatives and nuclear facilities in support of D and D activities. Specific objectives include: 1) identify and evaluate commercial-off-the-shelf (COTS) intumescent technologies, 2) conduct baseline fire testing of intumescent technologies, 3) develop a set of international standards to meet operational and safety requirements for D and D Technologies. In order to evaluate the above proposed research objectives, the following hypotheses have been postulated. - Select, test, and evaluate the suitability of certain 'near fit' ASTM flammability standards. - Baseline and down-select a set of existing COTS intumescent technologies (coatings and foams) to support D and D problem sets. - Determine feasibility of application methods for use inside a radioactive glovebox and hot cells for D and D purposes. - Develop international testing protocols for adapting the use of intumescent technologies to address needs of the D and D process. The proposed research will primarily take place at FIU-ARC. ARC and SRNL have conducted extensive coordination with the Savannah River Site's (SRS) 235-F PuFF facility personnel to facilitate planning in order to expedite the research and development (R and D) related to this effort. An initial set of documents associated with the specific facility hot cells, including schematics, assessment of the manipulator arms, anticipated particulate sizes of the Pu-238 contamination, an approved tooling list, etc., were formally reviewed and approved for release by the site to ARC. Utilizing these as a foundation, pre-planning for further adaptation of the intumescent technologies and the application during a full-scale cold demo at a hot cell testbed at ARC. One of the primary objectives is the testing and evaluation of the resistance of radiological shielding foams to thermal stressors. This objective was accomplished by conducting a flammability test and incremental temperature test. The goal of the flammability test is to conduct analytical tests to provide a classification for the foams as outlined below in accordance with IEC 60695-11-10. This test method is uniformly accepted throughout the industry as being critical indicators that quantifiably establish the flammability characteristics of plastics. It should be noted that polyurethane is not classified as a plastic, however, they do share similar properties deeming this a near fit test. IEC 60695-11-10:2013 specifies small-scale laboratory test procedures intended to compare the burning behavior of different materials when vertically or horizontally oriented test bar specimens are exposed to a small flame ignition source. Two test methods are described. Method A is a horizontal burning test and is intended to determine the linear burning rate of materials under specific test conditions. Method B is a vertical burning test and is intended to determine whether materials self-extinguish under specific test conditions. The purpose of the incremental temperature testing is to evaluate mass loss and dimensional changes that occurs to the radiological shielding foams when exposed to high temperatures in a muffle furnace. High temperatures often cause materials to undergo physical changes such as swelling or expanding. This is caused by the increase in kinetic energy and atomic and molecular movement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EPRI/NRC-RES fire human reliability analysis guidelines.

During the 1990s, the Electric Power Research Institute (EPRI) developed methods for fire risk analysis to support its utility members in the preparation of responses to Generic Letter 88-20, Supplement 4, 'Individual Plant Examination - External Events' (IPEEE). This effort produced a Fire Risk Assessment methodology for operations at power that was used by the majority of U.S. nuclear power plants (NPPs) in support of the IPEEE program and several NPPs overseas. Although these methods were acceptable for accomplishing the objectives of the IPEEE, EPRI and the U.S. Nuclear Regulatory Commission (NRC) recognized that they required upgrades to support current requirements for risk-informed, performance-based (RI/PB) applications. In 2001, EPRI and the USNRC's Office of Nuclear Regulatory Research (RES) embarked on a cooperative project to improve the state-of-the-art in fire risk assessment to support a new risk-informed environment in fire protection. This project produced a consensus document, NUREG/CR-6850 (EPRI 1011989), entitled 'Fire PRA Methodology for Nuclear Power Facilities' which addressed fire risk for at power operations. NUREG/CR-6850 developed high level guidance on the process for identification and inclusion of human failure events (HFEs) into the fire PRA (FPRA), and a methodology for assigning quantitative screening values to these HFEs. It outlined the initial considerations of performance shaping factors (PSFs) and related fire effects that may need to be addressed in developing best-estimate human error probabilities (HEPs). However, NUREG/CR-6850 did not describe a methodology to develop best-estimate HEPs given the PSFs and the fire-related effects. In 2007, EPRI and RES embarked on another cooperative project to develop explicit guidance for estimating HEPs for human failure events under fire generated conditions, building upon existing human reliability analysis (HRA) methods. This document provides a methodology and guidance for conducting a fire HRA. This process includes identification and definition of post-fire human failure events, qualitative analysis, quantification, recovery, dependency, and uncertainty. This document provides three approaches to quantification: screening, scoping, and detailed HRA. Screening is based on the guidance in NUREG/CR-6850, with some additional guidance for scenarios with long time windows. Scoping is a new approach to quantification developed specifically to support the iterative nature of fire PRA quantification. Scoping is intended to provide less conservative HEPs than screening, but requires fewer resources than a detailed HRA analysis. For detailed HRA quantification, guidance has been developed on how to apply existing methods to assess post-fire fire HEPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗