Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flammability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Interstage Flammability Analysis Approach

The Interstage of the Ares I launch platform houses several key components which are on standby during First Stage operation: the Reaction Control System (ReCS), the Upper Stage (US) Thrust Vector Control (TVC) and the J-2X with the Main Propulsion System (MPS) propellant feed system. Therefore potentially dangerous leaks of propellants could develop. The Interstage leaks analysis addresses the concerns of localized mixing of hydrogen and oxygen gases to produce deflagration zones in the Interstage of the Ares I launch vehicle during First Stage operation. This report details the approach taken to accomplish the analysis. Specified leakage profiles and actual flammability results are not presented due to proprietary and security restrictions. The interior volume formed by the Interstage walls, bounding interfaces with the Upper and First Stages, and surrounding the J2-X engine was modeled using Loci-CHEM to assess the potential for flammable gas mixtures to develop during First Stage operations. The transient analysis included a derived flammability indicator based on mixture ratios to maintain achievable simulation times. Validation of results was based on a comparison to Interstage pressure profiles outlined in prior NASA studies. The approach proved useful in the bounding of flammability risk in supporting program hazard reviews.

Little, Jeffrey K.↗

Evaluating Material Flammability in Microgravity and Martian Gravity Compared to the NASA Standard Normal Gravity Test

Drop tower tests are conducted at Martian gravity to determine the flammability of three materials compared to previous tests in other normal gravity and reduced gravity environments. The comparison is made with consideration of a modified NASA standard test protocol. Material flammability limits in the different gravity and flow environments are tabulated to determine the factor of safety associated with normal gravity flammability screening. Previous testing at microgravity and Lunar gravity indicated that some materials burned to lower oxygen concentrations in low gravity than in normal gravity, although the low g extinction limit criteria are not the same as 1g due to time constraints in drop testing. Similarly, the data presented in this paper for Martian gravity suggest that there is a gravity level below Earth s at which materials burn more readily than on Earth. If proven for more materials, this may indicate the need to include a factor of safety on 1g flammability limits.

Oslon, Sandra. L.↗

Non-Flammable Containment Bag and Enclosure Development for International Space Station Use

Work conducted on the International Space Station (ISS) requires the use of a significant quantity of containment bags to hold specimens, equipment, waste, and other material. The bags are in many shapes and sizes, and are typically manufactured from polyethylene materials. The amount of bags being used on ISS has grown to the point where fire safety has become a concern because of the flammability of polyethylene. Recently, a new re‐sealable bag design has been developed that is manufactured from a specialized non‐flammable material called Armorflex 301 that was designed specifically for this application. Besides being non‐flammable, Armorflex 301 is also FDA compliant, clear, flexible, and damage tolerant. The bags can be made with closure mechanisms that resemble ZipLoc® bags, or can be open top. Sample bags have been laboratory tested by NASA to verify materials properties, and evaluated by astronauts on the ISS in 2012. Flexloc bag manufacturing will commence in 2014 to support a transition away from polyethylene on ISS. In addition to re‐sealable bags, other larger containment systems such as flexible gloveboxes, deployable clean rooms, and other devices manufactured from Armorflex 301 are being explored for use on ISS and in similar confined space locations where flammability is an issue. This paper will describe the development of the Armorflex 301 material, the Flexloc bag, and other containment systems being explored for use in confined areas

Inamdar, Sunil↗

Flammability Configuration Analysis for Spacecraft Applications

Fire is one of the many potentially catastrophic hazards associated with the operation of crewed spacecraft. A major lesson learned by NASA from the Apollo 204 fire in 1966 was that ignition sources in an electrically powered vehicle should and can be minimized, but can never be eliminated completely. For this reason, spacecraft fire control is based on minimizing potential ignition sources and eliminating materials that can propagate fire. Fire extinguishers are always provided on crewed spacecraft, but are not considered as part of the fire control process. "Eliminating materials that can propagate fire" does not mean eliminating all flammable materials - the cost of designing and building spacecraft using only nonflammable materials is extraordinary and unnecessary. It means controlling the quantity and configuration of such materials to eliminate potential fire propagation paths and thus ensure that any fire would be small, localized, and isolated, and would self-extinguish without harm to the crew. Over the years, NASA has developed many solutions for controlling the configuration of flammable materials (and potentially flammable materials in commercial "off-the-shelf" hardware) so that they can be used safely in air and oxygen-enriched environments in crewed spacecraft. This document describes and explains these design solutions so payload customers and other organizations can use them in designing safe and cost-effective flight hardware. Proper application of these guidelines will produce acceptable flammability configurations for hardware located in any compartment of the International Space Station or other program crewed vehicles and habitats. However, use of these guidelines does not exempt hardware organizations of the responsibility for safety of the hardware under their control.

Pedley, Michael D.↗

Reduced-order model to estimate safe flammable refrigerant charge limits for a one-room air conditioner

The Heating, Ventilation, Air-Conditioning and Refrigeration (HVAC&R) industry is currently transitioning away from high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants. However, many lower-GWP alternatives are flammable. Current safety codes restrict use of all flammable refrigerants; revision of the codes is needed to facilitate wider use of flammable alternatives. Hence, information is needed to enable reliable estimates of safe charge limits for flammable refrigerant options for different HVAC&R applications. A reduced-order model (ROM) was developed and validated to help estimate safe charge limits based on computational fluid dynamics (CFD) simulations of refrigerant releases in a single room for a range of parameters. Validation of the ROM vs. the CFD results showed good general agreement for mean refrigerant concentration. The normalized mean bias error (NMBE) was 0.67% with a maximum error of 15%.

Edwards, Dean↗

DWPF Melter Off-Gas Flammability Assessment for Sludge Batch 9

The slurry feed to the Defense Waste Processing Facility (DWPF) melter contains several organic carbon species that decompose in the cold cap and produce flammable gases that could accumulate in the off-gas system and create potential flammability hazard. To mitigate such a hazard, DWPF has implemented a strategy to impose the Technical Safety Requirement (TSR) limits on all key operating variables affecting off-gas flammability and operate the melter within those limits using both hardwired/software interlocks and administrative controls. The operating variables that are currently being controlled include; (1) total organic carbon (TOC), (2) air purges for combustion and dilution, (3) melter vapor space temperature, and (4) feed rate. The safety basis limits for these operating variables are determined using two computer models, 4-stage cold cap and Melter Off-Gas (MOG) dynamics models, under the baseline upset scenario - a surge in off-gas flow due to the inherent cold cap instabilities in the slurry-fed melter.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non‐Flammable Ester Electrolyte with Boosted Stability Against Li for High‐Performance Li Metal Batteries

Abstract In traditional non‐flammable electrolytes a trade‐off always exists between non‐flammability and battery performance. Previous research focused on reducing free solvents and forming anion‐derived solid‐electrolyte interphase. However, the contribution of solvated anions in boosting the stability of electrolyte has been overlooked. Here, we resolve this via introducing anions into Li + solvation sheaths using anions with similar Gutmann donor number (DN) to that of solvents. Taking trimethyl phosphate fire‐retardant (DN=23.0 kcal mol −1 ) and NO 3 − (DN=22.2 kcal mol −1 ) as an example, NO 3 − is readily involved in the Li + solvation sheath and reduces the polarity of solvent. This results in boosted stability of electrolyte against Li. The developed non‐flammable electrolyte has low viscosity, high ionic conductivity and is low cost. The reversibility of Li‐Cu cell was improved to 99.49 % and the lifespan of practical LMBs was extended by >100 %.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of flammable volume in the case of a catastrophic leak of R-32 from a rooftop unit

With the effort to use alternative refrigerants with lower global warming potential (GWP), the majority of these alternative refrigerants are classified as slightly flammable. Here in this paper we report on the numerical evaluation of a catastrophic leak scenario of R-32 refrigerant from a 3-ton roof top air conditioning unit (RTU) which serves a 12.2 × 9.14 × 2.4 m room. A full rupture of a 6.35 mm (¼ inch) pipe downstream of the evaporator coil is simulated. Two separate cases with refrigerant releases of 1.81 kg and 3.62 kg charge have been studied. The two charges are released in 10.2 and 20.4 s, respectively, just after the end of a unit cooling cycle. The flammable volume inside the room existed only for about 40 s with a maximum flammable volume inside the room of 1.12% of the total room volume for the 3.62 kg charge case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development and Flammability Testing of Magnesium Alloys for Space Applications

This project will be comparing the flammability of select lightweight Mg alloys for use in a simulated ISS environment. It will also be determining the factors that influence flammability of selected alloys in elevated oxygen, including the formation of an oxide layer. The significance of this work is that such alloys can reduce weight saving by up to 30%. This work is adding to knowledge base of lightweight Mg alloys for possible future applications, as no previous flammability testing of Mg alloys have been conducted at elevated oxygen concentrations.

International Space Station↗

Non‐Flammable Ester Electrolyte with Boosted Stability Against Li for High‐Performance Li Metal Batteries

Abstract In traditional non‐flammable electrolytes a trade‐off always exists between non‐flammability and battery performance. Previous research focused on reducing free solvents and forming anion‐derived solid‐electrolyte interphase. However, the contribution of solvated anions in boosting the stability of electrolyte has been overlooked. Here, we resolve this via introducing anions into Li + solvation sheaths using anions with similar Gutmann donor number (DN) to that of solvents. Taking trimethyl phosphate fire‐retardant (DN=23.0 kcal mol −1 ) and NO 3 − (DN=22.2 kcal mol −1 ) as an example, NO 3 − is readily involved in the Li + solvation sheath and reduces the polarity of solvent. This results in boosted stability of electrolyte against Li. The developed non‐flammable electrolyte has low viscosity, high ionic conductivity and is low cost. The reversibility of Li‐Cu cell was improved to 99.49 % and the lifespan of practical LMBs was extended by >100 %.

Wang, Zhijie↗

Non-flammable electrolytes with high salt-to-solvent ratios for Li-ion and Li-metal batteries

Non-flammable electrolytes could intrinsically eliminate fire hazards and improve battery safety, but their compatibility with electrode materials, especially graphite anodes, remains an obstacle owing to the strong catalytic activity of the anode surfaces. Here, we report an approach that improves the stability of non-flammable phosphate electrolytes by adjusting the molar ratio of Li salt to solvent. At a high Li salt-to-solvent molar ratio (~1:2), the phosphate solvent molecules are mostly coordinated with the Li+ cations, and the undesired reactivity of the solvent molecules toward the graphite anode can be effectively suppressed. High cycling Coulombic efficiency (99.7%), good cycle life and safe operation of commercial 18650 Li-ion cells with these electrolytes are demonstrated. In addition, these non-flammable electrolytes show reduced reactivity toward Li-metal electrodes. Non-dendritic Li-metal plating and stripping in Li–Cu half-cells are demonstrated with high Coulombic efficiency (> 99%) and good stability.

Zeng, Ziqi↗

Flammability testing of components

Flammability testing of components in the design of Apollo spacecraft is discussed. The purpose of component flammability testing was to determine the flammability characteristics of a variety of different sizes, shapes, and configurations of nonmetallic materials of similar or different types that make up a functional assembly, subsystem, or system in a spacecraft. The test criteria and requirements for the nonmetallic materials are presented.

Primeaux, G. R.↗

Antimisting kerosene atomization and flammability

Various parameters found to affect the flammability of antimisting kerosene (Jet A + polymer additive) are investigated. Digital image processing was integrated into a technique for measurement of fuel spray characteristics. This technique was developed to avoid many of the error sources inherent to other spray assessment techniques and was applied to the study of engine fuel nozzle atomization performance with Jet A and antimisting fuel. Aircraft accident fuel spill and ignition dynamics were modeled in a steady state simulator allowing flammability to be measured as a function of airspeed, fuel flow rate, fuel jet Reynolds number and polymer concentration. The digital imaging technique was employed to measure spray characteristics in this simulation and these results were related to flammability test results. Scaling relationships were investigated through correlation of experimental results with characteristic dimensions spanning more than two orders of magnitude.

Fleeter, R.↗

Rheological behavior of FM-9 solutions and correlation with flammability test results and interpretations

The rheological behavior of progressively shear thickening FM-9 solutions, a time-dependent shear thickening material with characteristics of threshold behavior, is investigated as part of a study of the rheological properties of antimisting jet fuel. Flammability test results and test configurations from various sources are evaluated. A correlation is obtained between the rheological behavior and the flammability tests such that, for a given system, such as a fixed solvent system and the FM-9 polymer system, the flammability criterion can be applied to a wide range of concentrations and temperatures.

Peng, S. T. J.↗

Antimisting fuel breakup and flammability

The breakup behavior and flammability of antimisting turbine fuels subjected to aerodynamic shear are investigated. Fuels tested were Jet A containing 0.3% FM-9 polymer at various levels of degradation ranging from virgin AMK to neat Jet A. The misting behavior of the fuels was quantified by droplet size distribution measurements. A technique based on high resolution laser photography and digital image processing of photographic records for rapid determination of droplet size distribution was developed. The flammability of flowing droplet-air mixtures was quantified by direct measurements of temperature rise in a flame established in the wake of a continuous ignition source. The temperature rise measurements were correlated with droplet size measurements. The flame anchoring phenomenon associated with the breakup of a liquid fuel in the wake of bluff body was shown to be important in the context of a survivable crash scenario. A pass/fail criterion for flammability testing of antimisting fuels, based on this flame-anchoring phenomenon, was proposed. The role of various ignition sources and their intensity in ignition and post-ignition behavior of antimisting fuels was also investigated.

Parikh, P.↗

Flammability Limits of Gases Under Low Gravity Conditions

The purpose of this combustion science investigation is to determine the effect of zero, fractional, and super gravity on the flammability limits of a premixed methane air flame in a standard 51 mm diameter flammability tube and to determine, if possible, the fluid flow associated with flame passage under zero-g conditions and the density (and hence, temperature) profiles associated with the flame under conditions of incipient extinction. This is accomplished by constructing an appropriate apparatus for placement in NASA's Lewis Research Center Lear Jet facility and flying the prescribed g-trajectories while the experiment is being performed. Data is recorded photographically using the visible light of the flame. The data acquired is: (1) the shape and propagation velocity of the flame under various g-conditions for methane compositions that are inside the flammable limits, and (2) the effect of gravity on the limits. Real time accelerometer readings for the three orthogonal directions are displayed in full view of the cameras and the framing rate of the cameras is used to measure velocities.

Strehlow, R. A.↗

The possibility of a reversal of material flammability ranking from normal gravity to microgravity

The purpose of the discussion is to show, by a theoretical model, that one of the material flammability indices, the flammability limit, can be reversed in proper circumstances. A stagnation-point diffusion flame adjacent to a spherical solid-fuel surface is considered. It is shown that a reversal of the limiting oxygen indices from normal gravity and microgravity is possible. Although the example is based on a particular theoretical model with a particular flame configuration and specifically for an oxygen limit, the flammability-limit reversal phenomenon is believed to be more general.

T'Ien, James S.↗