Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flammability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Waste Isolation Pilot Plant Flammable Gas Analysis (Rev. 3.2)

This document describes and implements the process to establish the concentration of flammable gas/volatile organic compounds (VOCs), hydrogen, and methane in a waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II) or HalfPACT packagings. An aliquot of headspace gas (HSG) is sampled from a waste container and analyzed using one analytical unit which is a gas chromatograph (GC) with two detectors, a mass spectrometer (MS) and a thermal conductivity detector (TCD). The sample introduced to the GC is split and part goes to MS and the other part goes to TCD. The MS analyzes sample for volatile organic compounds (VOC) and the TCD analyzes for hydrogen and methane. The requirements and technical bases for allowable flammable gas/VOC concentrations are described in the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of Sensing Technologies for New, Low Global Warming Potential (GWP), Flammable Refrigerants

Commercial refrigeration systems currently utilize refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The advent of low GWP alternatives (GWP <150) is expected to significantly curtail direct emissions from this segment and greatly influence the ongoing electrification and decarbonization efforts. Most of the low GWP alternatives exhibit flammability risk and hence require robust sensing solutions for a reliable and safe operation of the equipment. This review article aims to provide an overview of different sensing mechanisms suitable for potential applications in systems employing flammable refrigerants, particularly those designated as A2L class. A summary of different A2L refrigerants and their properties is provided followed by a broad review of different classes of sensors, their working principle, transduction method, features, advantages, and limitations. Additionally, key performance characteristics of accuracy, selectivity, sensitivity, dynamic characteristic, and durability among other properties are discussed. Finally, areas of improvement and corresponding approaches are suggested for potential sensors in the successful adoption of A2L class refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flammable Gas Safety Self-Study 52827

This course, Flammable Gas Safety Self-Study (COURSE 52827), presents an overview of the hazards and controls associated with commonly used, compressed flammable gases at Los Alamos National Laboratory (LANL).

99 GENERAL AND MISCELLANEOUS↗

Methodology for Estimating Safe Charge Limits of Flammable Refrigerants in HVAC&R Applications - Part 1

Refrigerant flammability introduces new challenges to the usage of low global warming potential (Low GWP) refrigerants in real life applications. Those challenges are centered around the deflagration risk associated with their use and its implications on personal safety. Standards have been developed to systematically set maximum allowable flammable refrigerant charges to ensure safety in case of refrigerant leakage. These standards were initially based on limited testing and numerical analyses of refrigerant leakage into confined spaces.

42 ENGINEERING↗

Development of Low-Cost, High-Performance, Easy-To-Apply, Non-Flammable, Inorganic Phase Change Material (PCM) Technology (Project Final Report)

This report describes a 45-months long research program focused on the development of novel, easy-to-apply, non-flammable, and high-performance inorganic phase change materials (PCMs) for building and industrial applications. The University of Massachusetts Lowell (UML) formed a world-class team consisting of researchers form InsolCorp (only N. American manufacturer of inorganic PCM systems for building applications), and a group of industrial advisors, to develop a universal/multipurpose, simple-to-manufacture and cost-effective PCM technology. The project team expects that the results of this work will spur in the future the adoption of thermal storage materials – a key building energy saving technology as identified by DOE BTO – for a variety of building envelope applications. The main goal of this project was to demonstrate a suite of low-cost, multipurpose, and durable inorganic PCM formulations with phase transition temperatures encompassing typical building applications (between +5 o C and +55 o C). The first objective was to design, fabricate, and experimentally validate a performance of inexpensive, durable, highly efficient, non-flammable, and easy to manufacture PCMs. To allow a variety of building applications, the project team focused on formulations that exhibit repeatable phase transitions between +5 o C and +55 o C. To follow the DOE BTO cost efficiency target without compromising thermal performance, our work was based on inorganic compounds (mostly salt hydrates) and their blends, which represent a fraction of the cost of most of organic PCMs with about twice as high density as well as significantly higher thermal conductivity and phase change enthalpy. The second objective was to develop easy-to-manufacture and -install packaging/encapsulation designs that are 1) a superior barrier to current state-of-the-art macro-packaging, which significantly reduces the risk of loss of hydration water and PCM leak, and 2) optimal in enhancing the heat exchange rates with the surroundings and within the PCM core to ensure complete charging/discharging of the entire PCM within the product. Finally, the project’s intend was to scale-up the fabrication process to demonstrate installation on system-scale applications, and to validate the performance under field conditions. This work aimed at developing low-cost, high-energy storage, and reliable latent heat storage technology for building applications. This development was realized by formulating and integrating the following two technology components: 1) inorganic salt hydrate based PCMs that have high latent enthalpies and are low-cost and durable, and 2) PCM encapsulation (packaging) technology that maximizes PCM concentration and enhances heat transport characteristics in the product and with the external environment/materials. High thermal storage capacity, low cost and fire resistance are key to the building market entry for PCM technology. Therefore, the project’s focus was on salt-hydrate-based formulations which satisfy all these criteria. Packaging and/or encapsulation of PCM is a key processing step. The project team recognized that a low-cost and simple-to-manufacture salt hydrate-based PCM technology holds the best chance to be successful in the building construction market, a market which is traditionally extremely sensitive to cost and where commodity thermal insulations are the benchmark for envelope-related energy saving measures. That is why, in this project, the main intention was to minimize the production cost and maximize the product energy storage density without sacrificing the PCM performance. It was achieved through: 1. Minimizing the non-PCM components (plastics, additives, packaging/encapsulation materials, etc.) because they are significantly more expensive than salt hydrates, 2. Using highly thermally conductive and lightweight PCM carrier (packaging material) to facilitate more complete phase cycling, and 3. Optimizing the thickness and minimizing air spaces in product design (such as in pouched PCM). For this purpose, our approach was to enable an easy system design, including selection of the PCM operating temperatures, optimizing the necessary heat storage capacity (by stacking together several layers of PCM products), and if needed, a synchronized usage of PCM products of different temperatures. A specially designed, robust, highly thermally conducting and highly impermeable packaging (to retain salt hydrate water during phase transition cycles) was designed and tested to increase the overall system thermal performance and durability. All PCM products developed during this project were tested in both lab scale and in full scale field conditions. It is expected that, after further developments and commercialization, the developed PCM technologies may be also applied in space conditioning, energy storage technologies, and heat transfer applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Low-Flammable Electrolytes for Stable Operation of High-Voltage Lithium-Ion Batteries

Despite being an effective flame retardant, trimethyl phosphate (TMP a ) is generally considered as an unqualified solvent for fabricating electrolytes used in graphite (Gr) based lithium ion batteries as it readily leads to Gr exfoliation and cell failure. In this work, by adopting the unique solvation structure of localized high-concentration electrolyte (LHCE) to TMP a and tuning the composition of the solvation sheath via electrolyte additive, excellent electrochemical performance can be achieved with TMPa based electrolytes in Gr||LiNi 0.8 Mn 0.1 Co 0.1 O 2 cells. After 500 charge/discharge cycles within the voltage range of 2.5-4.4 V, the batteries containing TMPa based LHCEs with proper additive can achieve a capacity retention of 85.4%, being significantly higher than cells using a LiPF 6 -organocarbonates baseline electrolyte (75.2%). Meanwhile, due to the flame retarding effect of TMP a , TMP a based LHCEs exhibit significantly reduced flammability compared with the conventional LiPF 6 -organocarbonates electrolyte.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of radiation and compression on propagating spherical flames of methane/air mixtures near the lean flammability limit

Large discrepancies between the laminar flame speeds and Markstein lengths measured in experiments and those predicted by simulations for ultra-lean methane/air mixtures bring a great concern for kinetic mechanism validation. In order to quantitatively explain these discrepancies, a computational study is performed for propagating spherical flames of lean methane/air mixtures in different spherical chambers using different radiation models. The emphasis is focused on the effects of radiation and compression. It is found that the spherical flame propagation speed is greatly reduced by the coupling between thermal effect (change of flame temperature or unburned gas temperature) and flow effect (inward flow of burned gas) induced by radiation and/or compression. As a result, for methane/air mixtures near the lean flammability limit, the radiation and compression cause large amounts of under-prediction of the laminar flame speeds and Markstein lengths extracted from propagating spherical flames. Since radiation and compression both exist in the experiments on ultra-lean methane/air mixtures reported in the literature, the measured laminar flame speeds and Markstein lengths are much lower than results from simulation and thus cannot be used for kinetic mechanism validation. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical and experimental investigation of the flame kernel growth in a methane/air mixture near the lean flammability limit

Lean combustion has the potential to improve the thermal efficiency of spark-ignition engines, but it faces the significant challenge of increased cycle-to-cycle variation due to low mixture reactivity and unstable flame dynamics. Computational fluid dynamics (CFD) employing predictive models can guide engine design and optimize operating strategies for lean combustion. However, ignition and combustion models have rarely been validated at fuel-lean conditions, and a fundamental understanding of the early flame kernel growth process is also lacking for a successful sub-model development. Here, the present study develops a numerical simulation framework used to investigate early flame kernel growth in methane/air mixtures. A nanosecond-pulsed discharge (NPD) approach is employed to effectively decouple the flame kernel growth from the electrical discharge due to their difference in timescales, and equivalence ratios near the experimentally measured lean flammability limit (LFL) are selected to focus on challenging mixture conditions. Three numerical investigations, such as the choice of turbulence modeling, grid size, and grid control strategies, are examined to match both LFL and flame kernel structure measured from experiments. It is demonstrated that a quasi-direct numerical simulation (QDNS) with a fixed grid embedding of 10 μm can predict the LFL as φ CFD =0.61 and match the displacement speed of the kernel’s boundary marked in schlieren images. To predict the LFL and flame kernel shape, a fine grid (Δ≤12.5 μm) is needed to capture the consumption of formaldehyde (CH 2 O) in kernel’s reaction branches attached to the anode, and adaptive mesh refinement is replaced with the fixed embedding due to loss of simulation accuracy. Also, it is found that a large-eddy simulation (LES) using the Dynamic Structure model is not suitable for the NPD-induced flame kernel simulation because artificial sub-grid turbulent kinetic energy induced by shock dynamics alters the flow velocity calculation, resulting in divergence of LES from QDNS. Lastly, the simulation well matches the experimental data for the flame kernel evolution in three mixture conditions (φ = 0.7, 0.61, 0.55), showing toroidal flame kernel expansion and flame kernel growth/extinction.

33 ADVANCED PROPULSION SYSTEMS↗

Concentration fluctuations and flammability of cryo-compressed hydrogen and methane jets

Compressed hydrogen stored at cryogenic temperatures has a much higher density than room-temperature storage, which enables large-scale hydrogen storage and transport. An understanding of the release of cryogenic hydrogen from pressurized vessels is needed to evaluate the risk and safety concerns with the use of this fuel. Here, the present work extends the analysis of previous experimental studies that measured the gas concentrations of cryo-compressed hydrogen jets and methane jets using a laser Raman scattering diagnostic system. Since the Raman signals are very small, a denoising algorithm was applied to significantly reduce the noise to enable statistical analysis of the data. The transient features of the turbulent jets were characterized by their concentration intermittencies and probability density functions (PDFs). A two-part PDF was developed to predict the bimodal features of the jet concentration distributions. Then, the flammability factors of the cryogenic jets were calculated based on the intermittency and the PDF.

33 ADVANCED PROPULSION SYSTEMS↗

CHARACTERIZATION OF LOW-FLAMMABILITY ELECTROLYTES FOR LITHIUM-ION BATTERIES

In an effort to develop low-flammability electrolytes for a new generation of Li-ion batteries, we have evaluated physical and electrochemical properties of electrolytes with two proprietary phosphazene additives. We have studied performance quantities including conductivity, viscosity, flash point, and electrochemical window of electrolytes as well as formation of solid electrolyte interphase (SEI) films. In the course of study, the necessity for a simple method of SEI characterization was realized. Therefore, a new method and new criteria were developed and validated on 10 variations of electrolyte/electrode substrates. Based on the summation of determined physical and electrochemical properties of phosphazene-based electrolytes, one structure of phosphazene compound was found better than the other. This capability helps to direct our further synthetic work in phosphazene chemistry.

25 ENERGY STORAGE↗

Guidelines for Transportation, Handling, and Use of Fast Pyrolysis Bio-Oil. Part 1. Flammability and Toxicity

An alternative sustainable fuel, biomass-derived fast pyrolysis oil or 'bio-oil', is coming into the market. Fast pyrolysis pilot and demonstration plants for fuel applications producing tonnes of bio-oil are in operation, and commercial plants are under design. There will be increasingly larger amounts of bio-oil transportation on water and by land, leading to a need for specifications and supporting documentation. Bio-oil is different from conventional liquid fuels, and therefore must overcome both technical and marketing hurdles for its acceptability in the fuels market. A comprehensive Material Safety Data Sheet (MSDS) is required, backed with independent testing and certification. In order to standardise bio-oil quality specifications are needed. The first bio-oil burner fuel standard in ASTM (D7544) was approved in 2009. CEN standardisation has been initiated in Europe. In the EU a new chemical regulation system, REACH (Registration, Evaluation and Authorisation of Chemicals) is being applied. Registration under REACH has to be made if bio-oil is produced or imported to the EU. In the USA and Canada, bio-oil has to be filed under TOSCA (US Toxic Substances Control Act). In this paper the state of the art on standardisation is discussed, and new data for the transportation guidelines is presented. The focus is on flammability and toxicity.

09 BIOMASS FUELS↗

DWPF Melter Off-Gas Flammability Model for the Nitric-Glycolic Acid Flowsheet

The existing DWPF melter off-gas flammability model for the nitric-formic acid flowsheet feeds has been revised to reflect the upcoming reductant change from formic to glycolic acid. The necessary data for the model revision was obtained during Phase 2 of the Cold cap Evaluation Furnace (CEF) test, which was completed on March 21, 2014 after 24 days of round-the-clock feeding and pouring, including a total downtime of ~20 hours due to equipment failures. Specifically, the CEF was run to generate steady state melter off-gas data during the first 10 days using two nitric-glycolic acid flowsheet feeds prepared from a Sludge Batch 6 (SB6) simulant at 100% and 125% acid stoichiometry. Each feed was run under both bubbled and non-bubbled conditions, while maintaining the CEF vapor space temperature constant for at least two hours each targeting at 700, 600, 500, 400, 350, and <300 °C for a total of 24 steady state runs. During the next 8 days, the CEF was run at nominal vapor space temperature of 700 °C to generate off-gas surge data using the 100% acid stoichiometry feed under both bubbled and non-bubbled conditions. The remaining days were spent on producing additional steady state data using the 100% acid stoichiometry feed spiked with excess antifoam as well as re-running some of the earlier steady state runs.

CEF Phase 2↗

Flammability of New Diesel Fuels

Analytical evaluation of the flammability of alternative and blended fuels is considered. A method is proposed for determining the cetane number and ignition delay for fuels and the combustion characteristics in diesel engines.

09 BIOMASS FUELS↗

Advanced Low‐Flammable Electrolytes for Stable Operation of High‐Voltage Lithium‐Ion Batteries

Abstract Despite being an effective flame retardant, trimethyl phosphate (TMP a ) is generally considered as an unqualified solvent for fabricating electrolytes used in graphite (Gr)‐based lithium‐ion batteries as it readily leads to Gr exfoliation and cell failure. In this work, by adopting the unique solvation structure of localized high‐concentration electrolyte (LHCE) to TMP a and tuning the composition of the solvation sheaths via electrolyte additives, excellent electrochemical performance can be achieved with TMP a ‐based electrolytes in Gr∥LiNi 0.8 Mn 0.1 Co 0.1 O 2 cells. After 500 charge/discharge cycles within the voltage range of 2.5–4.4 V, the batteries containing the TMP a ‐based LHCE with a proper additive can achieve a capacity retention of 85.4 %, being significantly higher than cells using a LiPF 6 ‐organocarbonates baseline electrolyte (75.2 %). Meanwhile, due to the flame retarding effect of TMP a , TMP a ‐based LHCEs exhibit significantly reduced flammability compared with the conventional LiPF 6 ‐organocarbonates electrolyte.

Jia, Hao↗

Non-flammable electrolyte enables Li-metal batteries with aggressive cathode chemistries

Rechargeable Li-metal batteries using high-voltage cathodes can deliver the highest possible energy densities among all electrochemistries. However, the notorious reactivity of metallic lithium as well as the catalytic nature of high-voltage cathode materials largely prevents their practical application. Here, we report a non-flammable fluorinated electrolyte that supports the most aggressive and high-voltage cathodes in a Li-metal battery. Our battery shows high cycling stability, as evidenced by the efficiencies for Li-metal plating/stripping (99.2%) for a 5 V cathode LiCoPO 4 (-99.81%) and a Ni-rich LiNi 0.8 Mn 0.1 ,Co 0.3 ,O 2 cathode (-99.93%). At a loading of 2.0 mAh cm -2 , our full cells retain -93% of their original capacities after 1,000 cycles. Surface analyses and quantum chemistry calculations show that stabilization of these aggressive chemistries at extreme potentials is due to the formation of a several-nanometre-thick fluorinated interphase.

Fan, Xiulin↗

Waste Isolation Pilot Plant Flammable Gas Analysis (Rev. 4)

This document describes and implements the process to determine the concentration of flammable gas/volatile organic compounds (VOCs), hydrogen, and methane in a waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II), HalfPACT, TRUPACT-III, or RH-TRU72-B packagings. An aliquot of headspace gas (HSG) is sampled from a waste container and analyzed using a gas chromatograph (GC) with two detectors: a mass spectrometer (MS), and a thermal conductivity detector (TCD). The sample analyzed in the GC is split and half is sent to the MS for volatile organic compound (VOC) analysis while the other half is sent to the TCD for hydrogen and methane analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DOE/DOE Tight Oil Flammability & Transportation Spill Safety

This presentation describes crude oils, their phase behavior, the SPR vapor pressure program, and presents data comparisons from various analytical techniques. The overall objective is to describe physical properties of crude oil relevant to flammability and transport safety

02 PETROLEUM↗