Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flash Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

66 records · Page 4

Modeling of the Reactor Core Isolation Cooling Response to Beyond Design Basis Operations - Interim Report

Efforts are being pursued to develop and qualify a system-level model of a reactor core isolation (RCIC) steam-turbine-driven pump. The model is being developed with the intent of employing it to inform the design of experimental configurations for full-scale RCIC testing. The model is expected to be especially valuable in sizing equipment needed in the testing. An additional intent is to use the model in understanding more fully how RCIC apparently managed to operate far removed from its design envelope in the Fukushima Daiichi Unit 2 accident. RCIC modeling is proceeding along two avenues that are expected to complement each other well. The first avenue is the continued development of the system-level RCIC model that will serve in simulating a full reactor system or full experimental configuration of which a RCIC system is part. The model reasonably represents a RCIC system today, especially given design operating conditions, but lacks specifics that are likely important in representing the off-design conditions a RCIC system might experience in an emergency situation such as a loss of all electrical power. A known specific lacking in the system model, for example, is the efficiency at which a flashing slug of water (as opposed to a concentrated jet of steam) could propel the rotating drive wheel of a RCIC turbine. To address this specific, the second avenue is being pursued wherein computational fluid dynamics (CFD) analyses of such a jet are being carried out. The results of the CFD analyses will thus complement and inform the system modeling. The system modeling will, in turn, complement the CFD analysis by providing the system information needed to impose appropriate boundary conditions on the CFD simulations. The system model will be used to inform the selection of configurations and equipment best suitable of supporting planned RCIC experimental testing. Preliminary investigations with the RCIC model indicate that liquid water ingestion by the turbine decreases the developed turbine torque; the RCIC speed then slows, and thus the pump flow rate to the RPV decreases. Subsequently, RPV water level decreases due to continued boiling and the liquid fraction flowing to the RCIC decreases, thereby accelerating the RCIC and refilling the RPV. The feedback cycle then repeats itself and/or reaches a quasi-steady equilibrium condition. In other words, the water carry-over is limited by cyclic RCIC performance degradation, and hence the system becomes self-regulating. The indications achieved to date with the system model are more qualitative than quantitative. The avenues being pursued to increase the fidelity of the model are expected to add quantitative realism. The end product will be generic in the sense that the RCIC model will be incorporable within the larger reactor coolant system model of any nuclear power plant or experimental configuration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamics of face and annular seals with two-phase flow

A detailed study was made of face and annular seals under conditions where boiling, i.e., phase change of the leaking fluid, occurs within the seal. Many seals operate in this mode because of flashing due to pressure drop and/or heat input from frictional heating. Some of the distinctive behavior characteristics of two phase seals are discussed, particularly their axial stability. The main conclusions are that seals with two phase flow may be unstable if improperly balanced. Detailed theoretical analyses of low (laminar) and high (turbulent) leakage seals are presented along with computer codes, parametric studies, and in particular a simplified PC based code that allows for rapid performance prediction: calculations of stiffness coefficients, temperature and pressure distributions, and leakage rates for parallel and coned face seals. A simplified combined computer code for the performance prediction over the laminar and turbulent ranges of a two phase flow is described and documented. The analyses, results, and computer codes are summarized.

Hughes, William F.↗

Experimental study of external fuel vaporization

The fuel properties used in the design of a flash vaporization system for aircraft gas turbine engines were evaluated in experiments using a flowing system to determine critical temperature and pressure, boiling points, dew points, heat transfer coefficients, deposit formation rates, and deposit removal. Three fuels were included in the experiments: Jet-A, an experimental referree broad specification fuel, and a premium No. 2 diesel fuel. Engine conditions representing a NASA Energy Efficient Engine at sea-level take-off, cruise, and idle were simulated in the vaporization system and it was found that single phase flow was maintained in the heat exchanger and downstream of the throttle. Deposits encountered in the heat exchanger represented a thermal resistance as high as 1300 sq M K/watt and a deposit formation rate over 1000 gC/sq cm hr.

Szetela, E. J.↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers'’ for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field's Metal eutectic alloy with a melting point of 62°C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions. It is recommended that glass vessels of various volumes ranging from 125 mL to 1 gallon with modified tops containing the specified Field's Metal eutectic alloy which are appropriately designed to avoid flashing spray material releases be added to the DSA container list. These vessels will be utilized in the Shielded Cells for the storage of radioactive liquid samples of sludge slurries. Use of these vessels will also be advantageous for other liquid samples containing accountable amounts of nuclear material throughout other SRNL laboratories. Similarly constructed paraffin vessel lids could also potentially be added to the approved list, though additional testing would be required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers” for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field’s Metal eutectic alloy with a melting point of 62 °C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Natural Circulation Instability and Transients in Passively Safe Small Modular Reactors

The NEUP funded project, NEUP-3496, aims to experimentally investigate two-phase natural circulation flow instability that could occur in Small Modular Reactors (SMRs), especially for natural circulation SMRs. The objective has been achieved by systematically performing tests to study the general natural circulation instability characteristics and the natural circulation behavior under start-up or design basis accident conditions. Experimental data sets highlighting the effect of void reactivity feedback as well as the effect of power ramp-up rate and system pressure have been used to develop a comprehensive stability map. The safety analysis code, RELAP5, has been used to evaluate experimental results and models. Improvements to the constitutive relations for flashing have been made in order to develop a reliable analysis tool. This research has been focusing on two generic SMR designs, i.e. a small modular Simplified Boiling Water Reactor (SBWR) like design and a small integral Pressurized Water Reactor (PWR) like design. A BWR-type natural circulation test facility was firstly built based on the three-level scaling analysis of the Purdue Novel Modular Reactor (NMR) with an electric output of 50 MWe, namely NMR-50, which represents a BWR-type SMR with a significantly reduced reactor pressure vessel (RPV) height. The experimental facility was installed with various equipment to measure thermalhydraulic parameters such as pressure, temperature, mass flow rate and void fraction. Characterization tests were performed before the startup transient tests and quasi-steady tests to determine the loop flow resistance. The control system and data acquisition system were programmed with LabVIEW to realize the realtime control and data storage. The thermal-hydraulic and nuclear coupled startup transients were performed to investigate the flow instabilities at low pressure and low power conditions for NMR-50. Two different power ramps were chosen to study the effect of startup power density on the flow instability. The experimental startup transient results showed the existence of three different flow instability mechanisms, i.e., flashing instability, condensation induced flow instability, and density wave oscillations. In addition, the void-reactivity feedback did not have significant effects on the flow instability during the startup transients for NMR-50. ii Several initial startup procedures with different power ramp rates were experimentally investigated to eliminate the flow instabilities observed from the startup transients. Particularly, the very slow startup transient and pressurized startup transient tests were performed and compared. It was found that the very slow startup transients by applying very small power density can eliminate the flashing oscillations in the single-phase natural circulation and stabilize the flow oscillations in the phase of net vapor generation. The initially pressurized startup procedure was tested to eliminate the flashing instability during the startup transients as well. The pressurized startup procedure included the initial pressurization, heat-up, and venting process. The startup transient tests showed that the pressurized startup procedure could eliminate the flow instability during the transition from single-phase flow to two-phase flow at low pressure conditions. The experimental results indicated that both startup procedures were applicable to the initial startup of NMR. However, the pressurized startup procedures might be preferred due to short operating hours required. In order to have a deeper understanding of natural circulation flow instability, the quasi-steady tests were performed using the test facility installed with preheater and subcooler. The effect of system pressure, core inlet subcooling, core power density, inlet flow resistance coefficient, and void reactivity feedback were investigated in the quasi-steady state tests. The experimental stability boundaries were determined between unstable and stable flow conditions in the dimensionless stability plane of inlet subcooling number and Zuber number. To predict the stability boundary theoretically, linear stability analysis in the frequency domain was performed at four sections of the natural circulation test loop. The flashing phenomena in the chimney section was considered as an axially uniform heat source. And the dimensionless characteristic equation of the pressure drop perturbation was obtained by considering the void fraction effect and outlet flow resistance in the core section. The theoretical flashing boundary showed some discrepancies with previous experimental data from the quasi-steady state tests. In the future, thermal non-equilibrium was recommended to improve the accuracy of flashing instability boundary. As another part of the funded research, flow instabilities of a PWR-type SMR under low pressure and low power conditions were investigated experimentally as well. The NuScale reactor design was selected as the prototype for the PWR-type SMR. In order to experimentally study the natural circulation behavior of NuScale iii reactor during accidental scenarios, detailed scaling analyses are necessary to ensure that the scaled phenomena could be obtained in a laboratory test facility. The three-level scaling method is used as well to obtain the scaling ratios derived from various non-dimensional numbers. The design of the ideally scaled facility (ISF) was initially accomplished based on these scaling ratios. Then the engineering scaled facility (ESF) was designed and constructed based on the ISF by considering engineering limitations including laboratory space, pipe size, and pipe connections etc. PWR-type SMR experiments were performed in this well-scaled test facility to investigate the potential thermal hydraulic flow instability during the blowdown events, which might occur during the loss of coolant accident (LOCA) and loss of heat sink accident (LOHS) of the prototype PWR-type SMR. Two kinds of experiments, normal blowdown event and cold blowdown event, were experimentally investigated and compared with code predictions. The normal blowdown event was experimentally simulated since an initial condition where the pressure was lower than the designed pressure of the experiment facility, while the code prediction of blowdown started from the normal operation condition. Important thermal hydraulic parameters including reactor pressure vessel (RPV) pressure, containment pressure, local void fraction and temperature, pressure drop and natural circulation flow rate were measured and analyzed during the blowdown event. The pressure and water level transients are similar to the experimental results published by NuScale [51], which proves the capability of current loop in simulating the thermal hydraulic transient of real PWR-type SMR. During the 20000s blowdown experiment, water level in the core was always above the active fuel assemble during the experiment and proved the safety of natural circulation cooling and water recycling design of PWR-type SMR. Besides, pressure, temperature, and water level transient can be accurately predicted by RELAP5 code. However, the oscillations of natural circulation flow rate, water level and pressure drops were observed during the blowdown transients. This kind of flow oscillations are related to the water level and the location upper plenum, which is a path for coolant flow from chimney to steam generator and down comer. In order to investigate the transients start from the opening of ADS valve in both experimental and numerical way, the cold blow-down experiment is conducted. For the cold blowdown event, different from setting both reactor iv pressure vessel (RPV) and containment at high temperature and pressure, only RPV was heated close to the highest designed pressure and then open the ADS valve, same process was predicted using RELAP5 code. By doing cold blowdown experiment, the entire transients from the opening of ADS can be investigated by code and benchmarked with experimental data. Similar flow instability observed in the cold blowdown experiment. The comparison between code prediction and experiment data showed that the RELAP5 code can successfully predict the pressure void fraction and temperature transient during the cold blowdown event with limited error, but numerical instability exists in predicting natural circulation flow rate. Besides, the code is lack of capability in predicting the water level related flow instability observed in experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sustainable Aviation Fuel via Hydroprocessing of Catalytic Fast Pyrolysis Oil

Cycloalkanes have been identified as a promising alternative for sustainable aviation fuel (SAF) in a recent US Department of Energy Review of Technical Pathways to SAF. Cycloalkanes can provide desirable SAF properties, including energy density, and, in addition, they may be able to provide necessary seal swelling and leakage protection and replace undesirable aromatics in aviation fuel. Catalytic fast pyrolysis (CFP) followed by hydroprocessing constitutes a platform well suited for converting biomass to cycloalkanes. CFP oils are rich in phenolic compounds and, depending on CFP catalyst, in aromatic hydrocarbons, which can both be hydrogenated to form cycloalkanes. In this work, we report results from hydroprocessing of two types of CFP oil to produce fractions boiling in the sustainable aviation fuel range and meeting tested aviation fuel specifications. CFP oils prepared over a zeolite catalyst (ZSM-5) and a hydrodeoxygenation catalyst (Pt/TiO2) were hydroprocessed over a sulfided NiMo/Al2O3 catalyst in a two-stage process (1st stage ~250 degrees C and 2nd stage 385 degrees C) in a continuous trickle-bed hydrotreater. The hydrotreated product contained 39-40% material boiling in the SAF range by distillation with a carbon efficiency of 36-37% from CFP oil to SAF fraction. The SAF fractions consisted of 82-87% of cycloalkanes, had non-detectable oxygen contents and lower heating values (LHV) above the jet fuel minimum limit of 42.8 MJ/kg. The SAF-range product also had acceptable volatility and freeze and flash points per aviation fuel specifications. The results suggest a promising pathway for SAF production via the catalytic fast pyrolysis pathway. Methods to enhance the yield of SAF will be discussed.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗

Correlation of rocket propulsion fuel properties with chemical composition using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry followed by partial least squares regression analysis

There is an increased need to more fully assess and control the composition of kerosene based rocket propulsion fuels, namely RP-1 and RP-2. In particular, it is crucial to be able to make better quantitative connections between the following three attributes: (a) fuel performance, (b) fuel properties (flash point, density, kinematic viscosity, net heat of combustion, hydrogen content, etc) and (c) the chemical composition of a given fuel (i.e., specific chemical compounds and compound classes present as a result of feedstock blending and processing). Indeed, recent efforts in predicting fuel performance through modeling put greater emphasis on detailed and accurate fuel properties and fuel compositional information. In this regard, advanced distillation curve (ADC) metrology provides improved data relative to classical boiling point and volatility curve techniques. Using ADC metrology, data obtained from RP-1 and RP-2 fuels provides compositional variation information that is directly relevant to predictive modeling of fuel performance. Often, in such studies, one-dimensional gas chromatography (GC) combined with mass spectrometry (MS) is typically employed to provide chemical composition information. Building on approaches using GC-MS, but to glean substantially more chemical composition information from these complex fuels, we have recently studied the use of comprehensive two dimensional gas chromatography combined with time-of-flight mass spectrometry (GC × GC - TOFMS) to provide chemical composition data that is significantly richer than that provided by GC-MS methods. In this report, by applying multivariate data analysis techniques, referred to as chemometrics, we are able to readily model (correlate) the chemical compositional information from RP-1 and RP-2 fuels provided using GC × GC - TOFMS, to the fuel property information such as that provided by the ADC method and other specification properties. We anticipate that this new chemical analysis strategy will have broad implications for the development of high fidelity composition-property models, leading to an optimized approach to fuel formulation and specification for advanced engine cycles.

fuel↗

Thermal effects in two-phase flow through face seals

When liquid is sealed at high temperature, it flashes inside the seal due to pressure drop and/or viscous heat dissipation. Two-phase seals generally exhibit more erratic behavior than their single phase counterparts. Thermal effects, which are often neglected in single phase seal analyses, play an important role in determining seal behavior under two-phase operation. It is necessary to consider the heat generation due to viscous shear, conduction into the seal rings and convection with the leakage flow. Analytical models developed work reasonably well at the two extremes - for low leakage rates when convection is neglected and for higher leakage rates when conduction is neglected. A preliminary model, known as the Film Coefficient Model, is presented which considers conduction and convection both, and allows continuous boiling over an extended region unlike the previous low-leakage rate model which neglects convection and always forces a discrete boiling interface. Another simplified, semi-analytical model, based on the assumption of isothermal conditions along the seal interafce, has been developed for low leakage rates. The Film Coefficient Model may be used for more accurate and realistic description.

Basu, Prithwish↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank with Thermo-dynamic Vent System Assisted Injector

This paper presents a multi-node finite volume model of No Vent Filling (NVF) of a cryogenic tank with Thermo-dynamic Vent System (TVS) assisted injector, using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. NVF tests were conducted in a CRYOgenic Orbital Testbed (CRYOTE) tank which was filled by liquid nitrogen using a TVS assisted injector with vent valve closed during the entire filling process. In TVS assisted injector, the liquid flow splits into two streams: one stream is routed to a Joule-Thomson (J-T) orifice where the flow immediately flashes from liquid to vapor or two phase mixture because the downstream to J-T leg is maintained at vacuum level.; the other stream is injected into the tank after being cooled by cold vapor of J-T leg in a heat exchanger. The flow through J-T leg is also used to cool the outer metal matrix of the injector which in turn cools the vapor in the tank ullage. The cooling of vapor in the ullage by cold injector surface reduces ullage pressure that allows liquid to enter and fill the tank. An integrated numerical model of the test set up was developed. The model included the dual lines of TVS assisted injector, tank and tank wall. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor at ullage-injector interface and when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall temperature in the tank were compared with the test data.

Alok Majumdar↗

Reducing roughness and improving efficiency of MAPbI3 perovskite solar cells made by high-throughput photonic curing

For perovskite solar cells (PSCs) to be commercially viable, the slow and energy-insufficient thermal annealing step must be eliminated. Among the photo-irradiation methods proposed to replace thermal annealing, photonic curing is the fastest conversion method. Photonic curing delivers short (20 μs to 100 ms) but intense light pulses from a broadband (200-1500 nm) xenon flash lamp, making it the only method to convert perovskite under 20 ms. This processing time can be extrapolated to a roll-to-roll web speed of 40 m/min based on laboratory processing conditions. However, most reported PSCs made by photonic curing under 1 second have inferior performance (~10% PCE). Although SEM images show dense and pinhole-free perovskite films, AFM images indicate secondary wavy features of 500 nm-wide ridge and 80 nm-deep trenches on photonically cured perovskite films, the existence of which correlates with poor device performance. We suggest that this morphology feature is produced by volatile solvent evaporation during the fast photonic curing process. Two approaches have been made to remedy this issue: (1) adding CH2I2 as the third solvent in the conventional DMF-DMSO system and (2) applying a controlled air-blowing step before photonic curing to remove excess solvent further. Combining these two approaches produces photonically- cured perovskite films with a comparable film roughness and device performance. Alkyl halide additives have been reported to enhance PSC performance by modulated solvent-solute interactions and C-X (X = Cl, Br, and I) cleavage. Photonic curing can cleave CH2I2, producing disassociated iodide ions to replenish iodine loss induced by photonic curing, which is confirmed by EDX. As a co-solvent, the high boiling point of CH2I2 can also make the solvent less volatile, reducing surface roughness in photonically cured perovskite films. Additionally, photonically-cured perovskite films have longer PL lifetimes and a higher recombination resistance compared to thermally-annealed counterparts. As a result, we demonstrate that photonic curing is a suitable method to replace thermal annealing in high-throughput PSC fabrication.

14 SOLAR ENERGY↗