Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flash X-ray Accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Aerosol Imaging with a Soft X-ray Free Electron Laser

Lasers have long played a critical role in the advancement of aerosol science. A new regime of ultrafast laser technology has recently be realized, the world's first soft xray free electron laser. The Free electron LASer in Hamburg, FLASH, user facility produces a steady source of 10 femtosecond pulses of 7-32 nm x-rays with 10{sub 12} photons per pulse. The high brightness, short wavelength, and high repetition rate (>500 pulses per second) of this laser offers unique capabilities for aerosol characterization. Here we use FLASH to perform the highest resolution imaging of single PM2.5 aerosol particles in flight to date. We resolve to 35 nm the morphology of fibrous and aggregated spherical carbonaceous nanoparticles that existed for less than two milliseconds in vacuum. Our result opens the possibility for high spatialand time-resolved single particle aerosol dynamics studies, filling a critical technological need in aerosol science.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flash X-Ray measurements on the shock-induced dispersal of a dense particle curtain

The interaction of a Mach 1.67 shock wave with a dense particle curtain is quantified using flash radiography. These new data provide a view of particle transport inside a compressible, dense gas–solid flow of high optical opacity. The curtain, composed of 115-µm glass spheres, initially spans 87 % of the test section width and has a streamwise thickness of about 2 mm. Radiograph intensities are converted to particle volume fraction distributions using the Beer–Lambert law. The mass in the particle curtain, as determined from the X-ray data, is in reasonable agreement with that given from a simpler method using a load cell and particle imaging. Following shock impingement, the curtain propagates downstream and the peak volume fraction decreases from about 23 to about 4 % over a time of 340 µs. The propagation occurs asymmetrically, with the downstream side of the particle curtain experiencing a greater volume fraction gradient than the upstream side, attributable to the dependence of particle drag on volume fraction. Bulk particle transport is quantified from the time-dependent center of mass of the curtain. Furthermore, the bulk acceleration of the curtain is shown to be greater than that predicted for a single 115-µm particle in a Mach 1.67 shock-induced flow.

36 MATERIALS SCIENCE↗

Phase evolution during conventional and reactive flash sintering of (Mg,Ni,Co,Cu,Zn)O via in situ X-ray diffraction

Reactive flash sintering (RFS) enables the simultaneous synthesis and sintering of ceramics and has been shown to affect the reaction pathway of different materials. Herein, in situ synchrotron X-ray diffraction (XRD) is used to investigate the (Mg,Ni,Co,Cu,Zn)O entropy-stabilized oxide formation during: (i) conventional heating and (ii) RFS under current rate-controlled mode. The same reaction pathway is verified in both instances: the starting rock-salt (RS), spinel (Co 3 O 4 ), tenorite (CuO), and wurtzite (ZnO) phases transform into a single RS phase with a (1 1 1) to (2 0 0) intensity ratio of 0.67, consistent with a random distribution of the cations into the structure. Pt lattice peak shift from the XRD patterns is used as standard to monitor the sample surface temperature, revealing a strong endothermic reaction during the RS single-phase formation (Pt peaks shift toward higher angles while increasing sample temperature/current density). Furthermore, in RFS, the single-phase RS structure is formed in just 60 s at a furnace temperature of 600°C and a current rate of 220 mA mm -2 /min. Therefore, RFS greatly accelerates the synthesis of (Mg,Ni,Co,Cu,Zn)O, however, it does not play a role in the reaction pathway for this material formation.

36 MATERIALS SCIENCE↗

New Developments in Proton Radiography at the Los Alamos Neutron Science Center (LANSCE)

An application of nuclear physics, a facility for using protons for flash radiography, was developed at the Los Alamos Neutron Science Center (LANSCE). Protons have proven far superior to high energy x-rays for flash radiography because of their long mean free path, good position resolution, and low scatter background. Although this facility is primarily used for studying very fast phenomena such as high explosive driven experiments, it is finding increasing application to other fields, such as tomography of static objects, phase changes in materials and the dynamics of chemical reactions. The advantages of protons are discussed, data from some recent experiments will be reviewed and concepts for new techniques are introduced.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and development of a portable flash X-ray source driven by battery powered compact Marx generator

The design, construction and operational characteristics of a portable flash X-ray source driven by battery-powered compact Marx is reported. The novel configuration of compact Marx utilizes hollow capacitors in successive stages to enhance the erection reliability. The characteristic impedance of this system is ∼ 200 Ω. At discharge of ∼ 22 kV, >200 kV output pulse of 60 ns duration (FWHM) with rise time of <5 ns (10% - 90%) is produced. The pulser requires Nitrogen gas pressurization up to 3 atm for operation at maximum rating. The Marx generator assembly is fitted in to a stainless steel tube of 10 cm diameter and 1.2 m length. While using a demountable sealed X-ray tube of matched impedance, this device produces an X-ray pulse of approximately ∼ 30 ns duration and has maximum energy of ∼ 200 keV. This true tabletop device is able to produce dose up to 100 mR per shot, measured at the distance of 30 cm from output window. The focal spot size has been passively confirmed to be in the sub-millimeter (<1 mm) range. (author)

43 PARTICLE ACCELERATORS↗

Shocks and Tides Quantified in the “Sausage” Cluster, CIZA J2242.8+5301 Using N-body/Hydrodynamical Simulations

The colliding cluster, CIZA J2242.8+5301, displays a spectacular, almost 2 Mpc long shock front with a radio based Mach number M≃5, that is puzzlingly large compared to the X-ray estimate of M≃2.5. The extent to which the X-ray temperature jump is diluted by cooler unshocked gas projected through the cluster currently lacks quantification. Here we apply our self-consistent N-body/hydrodynamical code (based on FLASH) to model this binary cluster encounter. We can account for the location of the shock front and also the elongated X-ray emission by tidal stretching of the gas and dark matter between the two cluster centers. The required total mass is 8.9×10{sup 14} M{sub ⊙} with a 1.3:1 mass ratio favoring the southern cluster component. The relative velocity we derive is ≃2500 km s{sup −1} initially between the two main cluster components, with an impact parameter of 120 kpc. This solution implies that the shock temperature jump derived from the low angular resolution X-ray satellite Suzaku is underestimated by a factor of two, due to cool gas in projection, bringing the observed X-ray and radio estimates into agreement. Finally, we use our model to generate Compton-y maps to estimate the thermal Sunyaev–Zel’dovich (SZ) effect. At 30 GHz, this amounts to ΔS{sub n}=−0.072 mJy/arcmin{sup 2} and ΔS{sub s}=−0.075 mJy/arcmin{sup 2} at the locations of the northern and southern shock fronts respectively. Our model estimate agrees with previous empirical estimates that have inferred the measured radio spectra of the radio relics can be significantly affected by the SZ effect, with implications for charged particle acceleration models.

79 ASTRONOMY AND ASTROPHYSICS↗

Plasma Measurements in High Intensity Electron Beam Diodes

Experiments are being performed on the Self-Magnetic Pinch (SMP) electron beam diode on the RITS-6 accelerator at Sandia National Laboratories. This diode produces a tightly focused electron beam (< 3mm diameter) which is incident on a high atomic number bremsstrahlung x-ray converter. Typical diode parameters are 120 kA, 7 MeV, and 70ns current pulse, giving a ~45ns x-ray pulse. Plasmas from contaminants on the electrode surfaces propagate into the A-K vacuum gap, affecting the impedance, x-ray spectrum, and pulse width. These plasmas are measured using diagnostics, which include: spectroscopy, optical imaging, and photon detection; to obtain velocity, density, and temperature information. These parameters are measured both spatially, using multi-fiber arrays, and temporally, using streak cameras and avalanche photodiodes. Plasma densities and temperatures are determined from detailed, time-dependent, collisional-radiative (CT) and radiation transport (RT) models, which include Stark broadening of the hydrogen-alpha transition line and carbon ion line ratios. These results are combined with hybrid PIC/fluid simulations to model the plasma’s overall behavior. Densities of up to 10^19 cm-3 have been measured on the electrode surfaces, decreasing by several orders of magnitude both radially and axially across the vacuum gap. Electrode plasma expansion velocities of up to 10 cm/microsecond correlate well with the decreasing impedance profile (~0.5 Ohms/ns) observed during the pulse.

electron beam diodes↗

Microfocusing at the PG1 beamline at FLASH

The Kirkpatrick–Baez (KB) refocusing mirror system installed at the PG1 branch of the plane-grating monochromator beamline at the soft X-ray/XUV free-electron laser in Hamburg (FLASH) is designed to provide tight aberration-free focusing down to 4 µm × 6 µm full width at half-maximum (FWHM) on the sample. Such a focal spot size is mandatory to achieve ultimate resolution and to guarantee best performance of the vacuum-ultraviolet (VUV) off-axis parabolic double-monochromator Raman spectrometer permanently installed at the PG1 beamline as an experimental end-station. The vertical beam size on the sample of the Raman spectrometer, which operates without entrance slit, defines and limits the energy resolution of the instrument which has an unprecedented design value of 2 meV for photon energies below 70 eV and about 15 meV for higher energies up to 200 eV. In order to reach the designed focal spot size of 4 µm FWHM (vertically) and to hold the highest spectrometer resolution, special fully motorized in-vacuum manipulators for the KB mirror holders have been developed and the optics have been aligned employing wavefront-sensing techniques as well as ablative imprints analysis. Lastly, aberrations like astigmatism were minimized. In this article the design and layout of the KB mirror manipulators, the alignment procedure as well as microfocus optimization results are presented.

43 PARTICLE ACCELERATORS↗

Experimental development of rod pinch diode radiographic source using modified KALI 1000 pulsed power system

This paper highlights the development of Rod Pinch (RP) diode for flash X-ray generation as intense radiographic source at BARC, Vizag. The typical RP diode employed used a small diameter (1-2 mm) anode rod extended through a cathode circular aperture (5-6 mm inner diameter). The diode chamber is maintained at 10{sup -5} Torr vacuum by a rotary backed diffusion pump. Experiments performed on a modified Kali 1000 Pulsed Power System (300 kV, 30 kA, 100 ns) were aimed at optimizing the source by maximizing the figure of merit (dose @ 1m in rad/spot diameter{sup 2} in mm{sup 2}) with minimizing of the diode impedance. The typical electron beam parameters used in the experiments are 240-270 kV, 20-25 kA, 100 ns, with a few hundreds of kA/cm{sup 2} current density. The optimization resulted in a configuration with tungsten anode rod having dimensions of a 1.6 mm diameter, tapering extension length 5-25 mm beyond the graphite cathode aperture (Cathode disk ID = 5 mm, thickness = 3mm) to produce a radiation dose of 150-200 milli rad at 1 m distance having an estimated spot-size of 1-2 mm. The radiation emitted from a rod-pinch diode is measured using Thermoluminescence dosimeters (TLDs) at an angular interval of 15° on either side of the rod in horizontal and vertical plane. (author)

43 PARTICLE ACCELERATORS↗

Direct Observation of the ππ* to nπ* Transition in 2-Thiouracil via Time-Resolved NEXAFS Spectroscopy

The photophysics of nucleobases has been the subject of both theoretical and experimental studies over the past decades due to the challenges posed by resolving the steps of their radiationless relaxation dynamics, which cannot be described in the framework of the Born–Oppenheimer approximation (BOA). In this context, the ultrafast dynamics of 2-thiouracil has been investigated with a time-resolved NEXAFS study at the Free Electron Laser FLASH. Near Edge X-ray Absorption Fine Structure spectroscopy (NEXAFS) can be used to observe electronic transitions in ultrafast molecular relaxation. We performed time-resolved UV-pump/X-ray probe absorption measurements at the sulfur 2s (L1) and 2p (L2/3) edges. We are able to identify absorption features corresponding to the S2 (ππ*) and S1 (nπ*) electronic states. We observe a delay of 102 ± 11 fs in the population of the nπ* state with respect to the initial optical excitation and interpret the delay as the time scale for the S2 → S1 internal conversion. We furthermore identify oscillations in the absorption signal that match a similar observation in our previous X-ray photoelectron spectroscopy study on the same molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling between interfacial charge and mechanical deformation at high temperatures in ceramics. Final report

Basic research, under this project, has led to new fundamental discoveries in the effect of electric field (and temperature) on diffusion kinetics, electroluminescence and electronic conductivity in ceramic materials. For example, yttria stabilized zirconia sinters in just seconds well below 1000°C, while, at the same time, exhibiting a highly non-linear rise in conductivity, and intense electroluminescence. The phenomenon has been shown to occur in nearly all ceramics whether they are ionic or electronic conductors, or insulators. The rise in conductivity leads to Joule heating but in-situ measurements with a platinum standard at APS and Brookhaven (NSLS-II) have shown that the temperatures are much below what would have been needed to sinter in a few seconds. We have explored the hypothesis that huge concentrations of Frenkel pairs of vacancies and interstitials are produced. While these point defects accelerate sintering (by the interstitials being transported to the pores and the vacancies to the grain boundaries), they may also produce electron-hole pairs which can impart high electrical conductivity or recombine to emit photons. Many measurements, including in-situ measurements of lattice expansion are consistent with this hypothesis. However, the energy barrier for generating Frenkels in zirconia for example is much larger than can be expected at temperature and electrical fields in these experiments. Most recent work suggests that short wavelength phonons play a critical role in the genesis of the “flash” phenomenon. For example, the Debye temperature has been shown to be the lower bound for initiating flash. Molecular dynamics simulations have shown that large concentrations of Frenkel pairs can form under the proliferation of “optical” phonons at the edge of the Brillouin zone, that is with a wavelength at or below the lattice parameter. This project has led to the development of new experimental techniques as well as a software hardware interface for process and control and data analysis in real time, with a time scale of less than one second. This approach spells a new paradigm in materials science research. It potential impact on high rate manufacturing is self evident.

36 MATERIALS SCIENCE↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Suppression of the vacuum space-charge effect in fs-photoemission by a retarding electrostatic front lens

The performance of time-resolved photoemission experiments at fs-pulsed photon sources is ultimately limited by the e–e Coulomb interaction, downgrading energy and momentum resolution. Here, we present an approach to effectively suppress space-charge artifacts in momentum microscopes and photoemission microscopes. A retarding electrostatic field generated by a special objective lens repels slow electrons, retaining the k-image of the fast photoelectrons. The suppression of space-charge effects scales with the ratio of the photoelectron velocities of fast and slow electrons. Fields in the range from -20 to 01100 V/mm for E kin = 100 eV to 4 keV direct secondaries and pump-induced slow electrons back to the sample surface. Ray tracing simulations reveal that this happens within the first 40 to 3 μm above the sample surface for E kin = 100 eV to 4 keV. An optimized front-lens design allows switching between the conventional accelerating and the new retarding mode. Time-resolved experiments at E kin = 107 eV using fs extreme ultraviolet probe pulses from the free-electron laser FLASH reveal that the width of the Fermi edge increases by just 30 meV at an incident pump fluence of 22 mJ/cm2 (retarding field -21 V/mm). For an accelerating field of +2 kV/mm and a pump fluence of only 5 mJ/cm 2 , it increases by 0.5 eV (pump wavelength 1030 nm). At the given conditions, the suppression mode permits increasing the slow-electron yield by three to four orders of magnitude. The feasibility of the method at high energies is demonstrated without a pump beam at E kin = 3830 eV using hard x rays from the storage ring PETRA III. The approach opens up a previously inaccessible regime of pump fluences for photoemission experiments.

47 OTHER INSTRUMENTATION↗

RELATIVISTIC SHOCK BREAKOUTS-A VARIETY OF GAMMA-RAY FLARES: FROM LOW-LUMINOSITY GAMMA-RAY BURSTS TO TYPE Ia SUPERNOVAE

The light from a shock breakout of stellar explosions, which carries a wealth of information, strongly depends on the shock velocity at the time of the breakout. The emission from Newtonian breakouts, typical in regular core-collapse supernovae (SNe), has been explored extensively. However, a large variety of explosions result in mildly or ultrarelativistic breakouts, where the observed signature is unknown. Here we calculate the luminosity and spectrum produced by relativistic breakouts. In order to do so, we improve the analytic description of relativistic radiation-mediated shocks and follow the system from the breakout itself, through the planar phase and into the spherical phase. We limit our calculation to cases where the post-breakout acceleration of the gas ends during the planar phase (i.e., the final gas Lorentz factor {approx}< 30). We find that spherical relativistic breakouts produce a flash of gamma rays with energy, E{sub bo}, temperature, T{sub bo}, and duration, t{sup obs} b{sub o}, that provide the breakout radius ( Almost-Equal-To 5 R{sub Sun }(t{sup obs}{sub bo}/10 s)(T{sub bo}/50 keV){sup 2}) and the Lorentz factor ( Almost-Equal-To T{sub bo}/50 keV). They also always satisfy a relativistic breakout relation (t{sup obs}{sub bo}/20 s) {approx} (E{sub bo}/10{sup 46} erg){sup 1/2}(T{sub bo}/50 keV){sup -2.68}. The breakout flare is typically followed, on longer timescales, by X-rays that carry a comparable energy. We apply our model to a variety of explosions, including Type Ia and .Ia SNe, accretion-induced collapse, energetic SNe, and gamma-ray bursts (GRBs). We find that all these events produce detectable gamma-ray signals, some of which may have already been seen. Some particular examples are: (1) relativistic shock breakouts provide a natural explanation to the energy, temperature, and timescales of low-luminosity GRBs. Indeed, all observed low-luminosity GRBs satisfy the relativistic breakout relation. (2) Nearby broad-line Type Ib/c (like SN 2002ap) may produce a detectable {gamma}-ray signal. (3) Galactic Type Ia SNe may produce detectable {gamma}-ray flares. We conclude that relativistic shock breakouts provide a generic process for the production of gamma-ray flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Shielding Analysis of a Preclinical Bremsstrahlung X-ray FLASH Radiotherapy System within a Clinical Radiation Therapy Vault

A preclinical radiotherapy system producing FLASH dose rates with 12 MV bremsstrahlung x rays is being developed at Stanford University and SLAC National Accelerator Laboratory. Because of the high expected workload of 6,800 Gy w –1 at the isocenter, an efficient shielding methodology is needed to protect operators and the public while the preclinical system is operated in a radiation therapy vault designed for 6 MV x rays. Here, in this study, an analysis is performed to assess the shielding of the local treatment head and radiation vault using the Monte Carlo code FLUKA and the empirical methodology given in the National Council on Radiation Protection and Measurements Report 151. Two different treatment head shielding designs were created to compare single-layer and multilayer shielding methodologies using high-Z and low-Z materials. The multilayered shielding methodology produced designs with a 17% reduction in neutron fluence leaking from the treatment head compared to the single layered design of the same size, resulting in a decreased effective dose to operators and the public. The conservative assumptions used in the empirical methods can lead to over-shielding when treatment heads use polyethylene or multilayered shielding. High-Z/Low-Z multilayered shielding optimized via Monte Carlo is shown to be effective in the case of treatment head shielding and provide more effective shielding design for external beam radiotherapy systems that use 12 MV bremsstrahlung photons. Modifications to empirical methods used in the assessment of MV radiotherapy systems may be warranted to capture the effects of polyethylene in treatment head shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗

Saturated ablation in metal hydrides and acceleration of protons and deuterons to keV energies with a soft-x-ray laser

Studies of materials under extreme conditions have relevance to a broad area of research, including planetary physics, fusion research, materials science, and structural biology with x-ray lasers. We study such extreme conditions and experimentally probe the interaction between ultrashort soft x-ray pulses and solid targets (metals and their deuterides) at the FLASH free-electron laser where power densities exceeding 10{sup 17} W/cm{sup 2} were reached. Time-of-flight ion spectrometry and crater analysis were used to characterize the interaction. The results show the onset of saturation in the ablation process at power densities above 10{sup 16} W/cm{sup 2}. This effect can be linked to a transiently induced x-ray transparency in the solid by the femtosecond x-ray pulse at high power densities. The measured kinetic energies of protons and deuterons ejected from the surface reach several keV and concur with predictions from plasma-expansion models. Simulations of the interactions were performed with a nonlocal thermodynamic equilibrium code with radiation transfer. These calculations return critical depths similar to the observed crater depths and capture the transient surface transparency at higher power densities.

36 MATERIALS SCIENCE↗

Terrestrial Gamma-Ray Flashes as Powerful Particle Accelerators

Strong electric discharges associated with thunderstorms can produce terrestrial gamma-ray flashes (TGFs), i.e., intense bursts of x rays and {gamma} rays lasting a few milliseconds or less. We present in this Letter new TGF timing and spectral data based on the observations of the Italian Space Agency AGILE satellite. We determine that the TGF emission above 10 MeV has a significant power-law spectral component reaching energies up to 100 MeV. These results challenge TGF theoretical models based on runaway electron acceleration. The TGF discharge electric field accelerates particles over the large distances for which maximal voltages of hundreds of mega volts can be established. The combination of huge potentials and large electric fields in TGFs can efficiently accelerate particles in large numbers, and we reconsider here the photon spectrum and the neutron production by photonuclear reactions in the atmosphere.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗