Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Density and fluence dependence of lithium cell damage and recovery characteristics

Experimental results on lithium-containing solar cells point toward the lithium donor density gradient dN sub L/dw as being the crucial parameter in the prediction of cell behavior after irradiation by electrons. Recovery measurements on a large number of oxygen-rich and oxygen-lean lithium cells have confirmed that cell recovery speed is directly proportional to the value of the lithium gradient for electron fluences. Gradient measurements have also been correlated with lithium diffusion schedules. Results have shown that long diffusion times (25 h) with a paint-on source result in large cell-to-cell variations in gradient, probably due to a loss of the lithium source with time.

Faith, T. J.↗

On the use of quality factors and fluence to dose rate conversion in human radiation exposures

It is shown that various combinations of numbers and factors arrive at estimates of dose and dose effectiveness from values of fluence; but as yet it has not been possible to use biological data with the same degree of precision to estimate the physical data. It would seem that the most reasonable way to use the human data that exist is to apply them as far as possible to the human animal as a whole.

Sondhaus, C. A.↗

Probabilities for the peak flux and fluence of energetic solar protons incident on interplanetary spacecraft

Energetic protons injected into interplanetary space in solar particle events can interfere with spacecraft operations and experiments and can cause permanent degradation of some components. For future long term interplanetary and planetary missions, techniques were developed which use solar particle event data from 1956 through 1970 to predict the probability of exceeding any value of peak proton intensity or mission proton fluence. Dependences on proton energy (near 10 to 100 MeV), heliocentric distance, and phase of the solar cycle are included. The techniques are described and applied to the Mariner Jupiter/Saturn 1977 mission.

Divine, N.↗

Solar flare particle fluences during solar cycles 19, 20 and 21

Satellite data for solar flare particle events during solar cycle 21 (up to July 1982) have been analyzed to obtain event-integrated fluxes of energetic protons and alpha particles. Thirty nine events with proton fluences (E greater than 10 MeV) greater than 10-million/sq cm occurred during 1976-1982. The average flux of protons with kinetic energy greater than 10 MeV is 65 per sq cm/s for this period. The event averaged alpha to proton ratio, in the energy interval 1-22 MeV/n, varies between 0.006 to 0.04, with an average value of about 0.02 for the whole cycle. The flux of protons (with energies greater than 10 MeV) averaged over cycle 21 is lower than those for solar-cycle 20 per sq cm/s based on satellite data, and for solar-cycle 19 378 per sq cm/s based on lunar sample data. There is no definitive correlation between solar-cycle averaged proton fluxes and sunspot numbers.

Mcguire, R. E.↗

Temperature coefficients for concentrator cells at various electron and proton fluence levels

Data are presented on the Isc, Voc and Pmax temperature coefficients for several small concentrator solar cells. The cells are AlGaAs (1.72 eV), GaAs, silicon and InGaAs (1.1 eV) concentrator cells operating at 6.25 and 100 times AM0. The temperature range covered was 25 to 100 C. Cells were irradiated with 1-MeV electrons and 37-MeV protons, and data are presented at different fluence levels.

Curtis, Henry B.↗

A new model for the calculation and prediction of solar proton fluences

A new predictive engineering model for the energy greater than 10 MeV and greater than 30 MeV solar proton environment at earth is reviewed. The data used are from observations made from 1956 through 1985. In this data set, the distinction between 'ordinary events' and 'anomalously large events' that was required in earlier models disappeared. This permitted the use of statistical analysis methods developed for ordinary events on the entire data set. The greater than 10-MeV fluences with the new model are about twice those expected on the basis of earlier models. At energies greater than 30 MeV, the old and new models agree.

Feynman, Joan↗

LDEF atomic oxygen fluence update

The definition of LDEF atomic oxygen exposure involves theoretical prediction of fluxes, modeling of shielding and scattering effects, and comparison of predicted with observed atomic oxygen effects on LDEF experiments. Work is proceeding as follows: atomic oxygen fluxes and fluences have been recalculated using a more detailed orbit prediction program; a micro-environments program is being developed to account for the effects of experiment geometry on atomic oxygen flux; and chemical and physical measurements are being made on copper grounding straps to verify correspondence between predicted exposures and observed surface property variations. These three areas of work are reported briefly.

Bourassa, Roger J.↗

Fluence-based relative biological effectiveness for charged particle carcinogenesis in mouse Harderian gland

Neoplasia in the rodent Harderian gland has been used to determine the carcinogenic potential of irradiation by HZE particles. Ions from protons to lanthanum at energies up to 670 MeV/a have been used to irradiate mice, and prevalence of Harderian gland tumors has been measured 16 months after irradiation. The Relative Biological Effectiveness (RBE) for tumor induction has been expressed as the RBE(sub max), which is the ratio of the initial slopes of the dose vs prevalence curve. The RBE(sub max) has been found to be approximately 30 for ions with Linear Energy Transfer (LET) values in excess of 100 keV/micrometer. Analysis on the basis of fluence as a substitute for dose has shown that on a per particle basis all of the ions with LET values in excess of 100 keV/micrometer have equal effectiveness. An analysis of the probabilities of ion traversals of the nucleus has shown that for these high stopping powers that a single hit is effective in producing neoplastic transformation.

Alpen, E. L.↗

Fission foil measurements of neutron and proton fluences in the A0015 experiment

Results are given from sets of fission foil detectors (FFD's) (Ta-181, Bi-209, Th-232, U-238) which were included in the A0015 experiment to measure combined proton/neutron fluences. Use has been made of recent FFD high energy proton calibrations for improved accuracy of response. Comparisons of track density measurements have been made with the predictions of environmental modeling based on simple 1-D (slab) geometry. At 1 g/cm(exp 2) (trailing edge) the calculations were approximately 25 percent lower than measurements; at 13 g/cm(exp 2) (Earthside) calculations were more than a factor of 2 lower. A future 3-D modeling of the experiment is needed for a more meaningful comparison. Approximate mission proton doses and neutron dose equivalents were found. At Earthside (13 g/cm(exp 2) the dose was 171 rad and dose equivalent was 82 rem. At the trailing edge (1 g/cm(exp 2) dose was 315 rad and dose equivalent was 33 rem. The proton doses are less than expected from TLD doses by 16 percent and 37 percent, respectively. These differences can be explained by uncertainties in the proton and neutron spectra and in the method used to separate proton and neutron contributions to the measurements.

Frank, A. L.↗

Geomagnetic transmission disturbances and heavy-ion fluences observed in low Earth orbit during the solar energetic particle events of October 1989

The large solar energetic particle (SEP) events and simultaneous large geomagnetic disturbances observed during October 1989 posed a significant, rapidly evolving space radiation hazard. Using data from the GOES-7, NOAA-10, IMP-8 and LDEF satellites, we determined the geomagnetic transmission, heavy ion fluences, mean Fe ionic charge state, and effective radiation hazard observed in low Earth orbit (LEO) for these SEPs. We modeled the geomagneitc transmission by tracing particles through the combination to the internal International Geomagnetic Reference Field (IGRF) and the Tsyganenko (1989) magnetospheric field models, extending the modeling to large geomagnetic disturbances. We used our results to assess the radiation hazard such very large SEP events would pose in the anticipated 52 deg inclination space station orbit.

Boberg, P. R.↗

A Multigroup Method for the Calculation of Neutron Fluence with a Source Term

Current research on the Grant involves the development of a multigroup method for the calculation of low energy evaporation neutron fluences associated with the Boltzmann equation. This research will enable one to predict radiation exposure under a variety of circumstances. Knowledge of radiation exposure in a free-space environment is a necessity for space travel, high altitude space planes and satellite design. This is because certain radiation environments can cause damage to biological and electronic systems involving both short term and long term effects. By having apriori knowledge of the environment one can use prediction techniques to estimate radiation damage to such systems. Appropriate shielding can be designed to protect both humans and electronic systems that are exposed to a known radiation environment. This is the goal of the current research efforts involving the multi-group method and the Green's function approach.

Heinbockel, J. H.↗

Multi-Billion Shot, High-Fluence Exposure of Cr(4+): YAG Passive Q-Switch

NASA's Goddard Space Flight Center is developing the Geoscience Laser Altimeter System (GLAS) employing a diode pumped, Q-Switched, ND:YAG laser operating at 40 Hz repetition rate. To meet the five-year mission lifetime goal, a single transmitter would accumulate over 6.3 billion shots. Cr(4+):YAG is a promising candidate material for passively Q-switching the laser. Historically, the performance of saturable absorbers has degraded over long-duration usage. To measure the multi-billion shot performance of Cr(4+):YAG, a passively Q-switched GLAS-like oscillator was tested at an accelerated repetition rate of 500 Hz. The intracavity fluence was calculated to be approximately 2.5 J/cm(exp 2). The laser was monitored autonomously for 165 days. There was no evidence of change in the material optical properties during the 7.2 billion shot test.. All observed changes in laser operation could be attributed to pump laser diode aging. This is the first demonstration of multi-billion shot exposure testing of Cr(4+):YAG in this pulse energy regime

Stephen, Mark A.↗

Noble Gases in the Monahans Chondrite and Halite: Ar-39 - Ar-40 Age, Space Exposure Age, Trapped Solar Gases, and Neutron Fluence

In the Monahans H5 chondrite, Zolensky et al. report the first occurrence of grains of halite (NaCl), which contain minor sylvite (KCl) and tiny inclusions of liquid water. Here we report Ar-39 - Ar-40 ages of Monahans light (4.53 Ga) and dark phases and of the halite (>4.33 Ga). We report the presence of trapped solar gases in the dark phase, demonstrating that it represents a prior regolith on the Monahans parent body, We also report the cosmic-ray exposure age of Monahans and the neutron fluence experienced by the regolith component. Because the halite grains are apparently located only in the regolith phase, they may have formed by early hydrous activity within the Monahans parent body regolith, or they may have been introduced from outside.

Bogard, Donald D.↗

Fluence-based and microdosimetric event-based methods for radiation protection in space

The National Council on Radiation Protection and Measurements (NCRP) has recently published a report (Report #137) that discusses various aspects of the concepts used in radiation protection and the difficulties in measuring the radiation environment in spacecraft for the estimation of radiation risk to space travelers. Two novel dosimetric methodologies, fluence-based and microdosimetric event-based methods, are discussed and evaluated, along with the more conventional quality factor/LET method. It was concluded that for the present, any reason to switch to a new methodology is not compelling. It is suggested that because of certain drawbacks in the presently-used conventional method, these alternative methodologies should be kept in mind. As new data become available and dosimetric techniques become more refined, the question should be revisited and that in the future, significant improvement might be realized. In addition, such concepts as equivalent dose and organ dose equivalent are discussed and various problems regarding the measurement/estimation of these quantities are presented.

NASA Discipline Radiation Health↗

The Meteoroid Fluence at Mars Due to Comet Siding Spring

Long-period comet C/2013 A1 (Siding Spring) is headed for a close encounter with Mars on 2014 Oct 19. A collision between the comet and the planet has been ruled out, but the comets coma may envelop Mars and its man-made satellites. We present an analytic model of the dust component of cometary comae that describes the spatial distribution of cometary dust and meteoroids and their size distribution. If the coma reaches Mars, we estimate a total incident particle fluence on the planet and its satellites of 0.01 particles per square meter. We compare our model with numerical simulations, data from past comet missions, and recent Siding Spring observations.

Moorhead, Althea V.↗