Search NASA⌕ Search

SEARCH · Search NASA

Results for “Forearm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dynamic model and cooperative control of a serially linked manipulator system

The use of a redundant manipulator to execute multiple tasks specified at different points on the manipulator is demonstrated. This is accomplished by decomposing a redundant arm at an intermediate arm location called the 'elbow' into two nonredundant local arms referred as the 'basearm' and the 'forearm'. This decomposition transforms a redundant arm into a serially linked dual-arm system, where the cooperation between the basearm and the forearm is carried out through the task distribution and the elbow control. The kinematics of a decomposed redundant manipulator are discussed, and a Cartesian space dynamic model and dynamic equation of a decomposed redundant manipulator are presented. The capability of generating Cartesian force, the local efficiency of generating Cartesian acceleration, and dynamic task distribution are discussed.

Lee, Sukhan↗

Prosthetic Hand With Two Gripping Fingers

Prosthetic hand developed for amputee who retains significant portion of forearm. Outer end of device is end effector including two fingers, one moved by rotating remaining part of forearm about its longitudinal axis. Main body of end effector is end member supporting fingers, roller bearing assembly, and rack-and-pinion mechanism. Advantage of rack-and-pinion mechanism enables user to open or close gap between fingers with precision and force.

Norton, William E.↗

Low-Fatigue Hand Controller For Remote Manipulator

Universal master controller used in brace mode, in which user's forearm rests atop upper (forearm) module. Alternatively, user manipulates hand controller in side mode, which gives greater latitude for motion but requires more muscular effort. Controller provides six degrees of freedom and reflects, back to user, scaled versions of forces experienced by manipulator. Manipulator designed to condense work space into user's natural work volume. Operated by both right-handed and left-handed users. Does not interfere with user's natural movements or obstruct line of sight. Controller compact and portable.

Maclaren, Brice↗

Quantitative Tester And Reconditioner For Hand And Arm

Apparatus measures torques, forces, and motions of hand, wrist, forearm, elbow, and shoulder and aids in reconditioning muscles involved. Used to determine strengths and endurances of muscles, ranges of motion of joints, and reaction times. Provides quantitative data used to assess extent to which disuse, disease, or injury causes deterioration of muscles and of motor-coordination skills. Same apparatus serves as exercise machine to restore muscle performance by imposing electronically controlled, gradually increasing loads on muscles. Suitable for training and evaluating astronauts, field testing for workers' compensation claims, and physical therapy in hospitals. With aid of various attachments, system adapted to measure such special motions as pinching, rotation of wrist, and supination and pronation of the forearm. Attachments are gloves, wristlets, and sleeves.

Engle, Gary↗

THE VERTICAL

'THE VERTICAL' computer keyboard is designed to address critical factors which contribute to Repetitive Motion Injuries (RMI) (including Carpal Tunnel Syndrome) in association with computer keyboard usage. This keyboard splits the standard QWERTY design into two halves and positions each half 90 degrees from the desk. In order to access a computer correctly. 'THE VERTICAL' requires users to position their bodies in optimal alignment with the keyboard. The orthopaedically neutral forearm position (with hands palms-in and thumbs-up) reduces nerve compression in the forearm. The vertically arranged keypad halves ameliorate onset occurrence of keyboard-associated RMI. By utilizing visually-reference mirrored mylar surfaces adjustable to the user's eye, the user is able to readily reference any key indicia (reversed) just as they would on a conventional keyboard. Transverse adjustability substantially reduces cumulative musculoskeletal discomfort in the shoulders. 'THE VERTICAL' eliminates the need for an exterior mouse by offering a convenient finger-accessible curser control while the hands remain in the vertically neutral position. The potential commercial application for 'THE VERTICAL' is enormous since the product can effect every person who uses a computer anywhere in the world. Employers and their insurance carriers are spending hundreds of millions of dollars per year as a result of RMI. This keyboard will reduce the risk.

Albert, Stephen L.↗

Mechanical counter pressure on the arm counteracts adverse effects of hypobaric exposures

INTRODUCTION: Current space suits have limited movement due to gas pressurization during exposure to the vacuum of space. Alternatively, if pressure is applied by an elastic garment vs. pneumatic garment to produce mechanical counter pressure (MCP), several advantages are possible. In this study, we investigate local microcirculatory and other effects produced with and without a prototype MCP glove and sleeve during exposure to varying levels of vacuum. METHODS: The entire arms of eight male volunteers were studied at normal ambient pressure and during 5 min exposures to -50, -100, and -150 mm Hg with and without the MCP glove and sleeve. Pressure distribution, skin microvascular flow, and temperature were measured. RESULTS: The MCP glove and sleeve generated over 200 mm Hg on the middle finger, dorsum of the hand, and the wrist. However, pressure was significantly lower on the forearm and the upper arm. Without the glove and sleeve, only two of eight subjects tolerated -100 mm Hg. Also, no subject tolerated -150 mm Hg. However, subjects tolerated all vacuum pressures wearing the glove and sleeve. Skin microvascular flow and temperature remained within control values with the glove and sleeve at a chamber pressure of -150 mm Hg. DISCUSSION: The MCP glove and sleeve counteracts adverse effects of vacuum exposures due to lower pressure differentials. Pressure levels over the hand and wrist are similar to those of the current U.S. space suit glove and sleeve, but additional development is required to increase MCP over the forearm and upper arm.

NASA Discipline Cardiopulmonary↗

Individual thermal profiles as a basis for comfort improvement in space and other environments

BACKGROUND: The development of individualized countermeasures to address problems in thermoregulation is of considerable importance for humans in space and other extreme environments. A methodology is presented for evaluating minimal/maximal heat flux from the total human body and specific body zones, and for assessing individual differences in the efficiency of heat exchange from these body areas. The goal is to apply this information to the design of individualized protective equipment. METHODS: A multi-compartment conductive plastic tubing liquid cooling/warming garment (LCWG) was developed. Inlet water temperatures of 8-45 degrees C were imposed sequentially to specific body areas while the remainder of the garment was maintained at 33 degrees C. RESULTS: There were significant differences in heat exchange level among body zones in both the 8 degrees and 45 degrees C temperature conditions (p < 0.001). The greatest amount of heat was absorbed/released by the following areas: thighs (8 degrees C: -2.12 +/- 0.14 kcal min(-1); 45 degrees C: +1.58 +/- 0.23); torso (8 degrees C: -2.12 +/- 0.13 kcal min(-1); 45 degrees C: +1.31 +/- 0.27); calves (8 degrees C: -1.59 +/- 0.26 kcal min(-1); 45 degrees C: +1.53 +/- 0.24); and forearms (8 degrees C: -1.67 +/- 0.29 kcal x min(-1); 45 degrees C: +1.45 +/- 0.20). These are primarily zones with relatively large muscle mass and adipose tissue. Calculation of absorption/release heat rates standardized per unit tube length and flow rate instead of zonal surface area covered showed that there was significantly greater heat transfer in the head, hands, and feet (p < 0.001). The areas in which there was considerable between-subject variability in rates of heat transfer and thus most informative for individual profile design were the torso, thighs, shoulders, and calves or forearms. CONCLUSIONS: The methodology developed is sensitive to individual differences in the process of heat exchange and variations in different body areas, depending on their size and tissue mass content. The design of individual thermal profiles is feasible for better comfort of astronauts on long-duration missions and personnel in other extreme environments.

NASA Discipline Life Sciences Technologies↗

Effect of whole-body and local heating on cutaneous vasoconstrictor responses in humans

Animal studies suggest that alpha-adrenergic-mediated vasoconstriction is compromised during whole-body heating. The purpose of this study was to identify whether whole-body heating and/or local surface heating reduce cutaneous alpha-adrenergic vasoconstrictor responsiveness in human skin. Protocol I: Six subjects were exposed to neutral skin temperature (i.e., 34 degrees C), whole-body heating, and local heating of forearm skin to increase skin blood flow to the same relative magnitude as that observed during whole-body heating. Protocol II: In eight subjects forearm skin was locally heated to 34, 37, 40, and 42 degrees C. During both protocols, alpha-adrenergic vasoconstrictor responsiveness was assessed by local delivery of norepinephrine (NE) via intradermal microdialysis. Skin blood flow was continuously monitored over each microdialysis membrane via laser-Doppler flowmetry. In protocol I, whole-body and local heating caused similar increases in cutaneous vascular conductance (CVC). The EC50 (log NE dose) of the dose-response curves for both whole body (-4.2 +/- 0.1 M) and local heating (-4.7 +/- 0.4 M) were significantly greater (i.e., high dose required to cause 50% reduction in CVC) relative to neutral skin temperature (- 5.6 +/- 0.0 M; P<0.05 for both). In both local and whole-body heated conditions CVC did not return to pre-heating values even at the highest dose of NE. In protocol II, calculated EC50 for 34, 37, 40, and 42 degrees C local heating was - 5.5 +/- 0.4, -4.6 +/- 0.3, -4.5 +/- 0.3, - 4.2 +/- 0.4 M, respectively. Statistical analyses revealed that the EC50 for 37,40 and 42 degrees C were significantly greater than the EC50 for 34 degrees C. These results indicate that even during administration of high concentrations of NE, alpha-adrenergic vasoconstriction does not fully compensate for local heating and whole-body heating induced vasodilatation in young, healthy subjects. Moreover, these data suggest that elevated local temperatures, above 37 degrees C, and whole-body heating similarly attenuate cutaneous alpha-adrenergic vasoconstriction responsiveness.

Non-NASA Center↗

Evidence that the human cutaneous venoarteriolar response is not mediated by adrenergic mechanisms

The venoarteriolar response causes vasoconstriction to skin and muscle via local mechanisms secondary to venous congestion. The purpose of this project was to investigate whether this response occurs through alpha-adrenergic mechanisms. In supine individuals, forearm skin blood flow was monitored via laser-Doppler flowmetry over sites following local administration of terazosin (alpha(1)-antagonist), yohimbine (alpha(2)-antagonist), phentolamine (non-selective alpha-antagonist) and bretylium tosylate (inhibits neurotransmission of adrenergic nerves) via intradermal microdialysis or intradermal injection. In addition, skin blood flow was monitored over an area of forearm skin that was locally anaesthetized via application of EMLA (2.5 % lidocaine (lignocaine) and 2.5 % prilocaine) cream. Skin blood flow was also monitored over adjacent sites that received the vehicle for the specified drug. Each trial was performed on a minimum of seven subjects and on separate days. The venoarteriolar response was engaged by lowering the subject's arm from heart level such that the sites of skin blood flow measurement were 34 +/- 1 cm below the heart. The arm remained in this position for 2 min. Selective and non-selective alpha-adrenoceptor antagonism and presynaptic inhibition of adrenergic neurotransmission did not abolish the venoarteriolar response. However, local anaesthesia blocked the venoarteriolar response without altering alpha-adrenergic mediated vasoconstriction. These data suggest that the venoarteriolar response does not occur through adrenergic mechanisms as previously reported. Rather, the venoarteriolar response may due to myogenic mechanisms associated with changes in vascular pressure or is mediated by a non-adrenergic, but neurally mediated, local mechanism.

Non-NASA Center↗

Cutaneous interstitial nitric oxide concentration does not increase during heat stress in humans

Inhibition of cutaneous nitric oxide (NO) synthase reduces the magnitude of cutaneous vasodilation during whole body heating in humans. However, this observation is insufficient to conclude that NO concentration increases in the skin during a heat stress. This study was designed to test the hypothesis that whole body heating increases cutaneous interstitial NO concentration. This was accomplished by placing 2 microdialysis membranes in the forearm dermal space of 12 subjects. Both membranes were perfused with lactated Ringer solutions at a rate of 2 microl/min. In both normothermia and during whole body heating via a water perfused suit, dialysate from these membranes were obtained and analyzed for NO using the chemiluminescence technique. In six of these subjects, after the heat stress, the membranes were perfused with a 1 M solution of acetylcholine to stimulate NO release. Dialysate from these trials was also assayed to quantify cutaneous interstitial NO concentration. Whole body heating increased skin temperature from 34.6 +/- 0.2 to 38.8 +/- 0.2 degrees C (P < 0.05), which increased sublingual temperature (36.4 +/- 0.1 to 37.6 +/- 0.1 degrees C; P < 0.05), heart rate (63 +/- 5 to 93 +/- 5 beats/min; P < 0.05), and skin blood flow over the membranes (21 +/- 4 to 88 +/- 10 perfusion units; P < 0.05). NO concentration in the dialysate did not increase significantly during of the heat stress (7.6 +/- 0.7 to 8.6 +/- 0.8 microM; P > 0.05). After the heat stress, administration of acetylcholine in the perfusate significantly increased skin blood flow (128 +/- 6 perfusion units) relative to both normothermic and heat stress values and significantly increased NO concentration in the dialysate (15.8 +/- 2.4 microM). These data suggest that whole body heating does not increase cutaneous interstitial NO concentration in forearm skin. Rather, NO may serve in a permissive role in facilitating the effects of an unknown neurotransmitter, leading to cutaneous vasodilation during a heat stress.

Non-NASA Center↗

Limb congestion enhances the synchronization of sympathetic outflow with muscle contraction

In this report, we examined if the synchronization of muscle sympathetic nerve activity (MSNA) with muscle contraction is enhanced by limb congestion. To explore this relationship, we applied signal-averaging techniques to the MSNA signal obtained during short bouts of forearm contraction (2-s contraction/3-s rest cycle) at 40% maximal voluntary contraction for 5 min. We performed this analysis before and after forearm venous congestion; an intervention that augments the autonomic response to sustained static muscle contractions via a local effect on muscle afferents. There was an increased percentage of the MSNA noted during second 2 of the 5-s contraction/rest cycles. The percentage of total MSNA seen during this particular second increased from minute 1 to 5 of contraction and was increased further by limb congestion (control minute 1 = 25.6 +/- 2.0%, minute 5 = 32.8 +/- 2.2%; limb congestion minute 1 = 29.3 +/- 2.1%, minute 5 = 37.8 +/- 3.9%; exercise main effect <0.005; limb congestion main effect P = 0.054). These changes in the distribution of signal-averaged MSNA were seen despite the fact that the mean number of sympathetic discharges did not increase over baseline. We conclude that synchronization of contraction and MSNA is seen during short repetitive bouts of handgrip. The sensitizing effect of contraction time and limb congestion are apparently due to feedback from muscle afferents within the exercising muscle.

Non-NASA Center↗

Age, splanchnic vasoconstriction, and heat stress during tilting

During upright tilting, blood is translocated to the dependent veins of the legs and compensatory circulatory adjustments are necessary to maintain arterial pressure. For examination of the effect of age on these responses, seven young (23 +/- 1 yr) and seven older (70 +/- 3 yr) men were head-up tilted to 60 degrees in a thermoneutral condition and during passive heating with water-perfused suits. Measurements included heart rate (HR), cardiac output (Qc; acetylene rebreathing technique), central venous pressure (CVP), blood pressures, forearm blood flow (venous occlusion plethysmography), splanchnic and renal blood flows (indocyanine green and p-aminohippurate clearance), and esophageal and mean skin temperatures. In response to tilting in the thermoneutral condition, CVP and stroke volume decreased to a greater extent in the young men, but HR increased more, such that the fall in Qc was similar between the two groups in the upright posture. The rise in splanchnic vascular resistance (SVR) was greater in the older men, but the young men increased forearm vascular resistance (FVR) to a greater extent than the older men. The fall in Qc during combined heat stress and tilting was greater in the young compared with older men. Only four of the young men versus six of the older men were able to finish the second tilt without becoming presyncopal. In summary, the older men relied on a greater increase in SVR to compensate for a reduced ability to constrict the skin and muscle circulations (as determined by changes in FVR) during head-up tilting.

NASA Discipline Cardiopulmonary↗

Cardiovascular function following reduced aerobic activity

PURPOSE: The aim of this study was to test the hypothesis that a sustained reduction of physical activity (deconditioning) would alter the cardiovascular regulatory function. METHODS: Nineteen young, healthy volunteers participated in physical deconditioning for a period of 8 wk. Before (pre) and following (post) physical deconditioning, the responses of heart rate (HR), mean arterial pressure (MAP, measured by Finapres), central venous pressure (CVP), stroke volume (SV, Doppler), and forearm blood flow (FBF, plethysmography) were determined during lower body negative pressure (LBNP). The carotid baroreflex (CBR) function was assessed using a train of pulsatile neck pressure (NP) and suction, and the aortic baroreflex control of HR was assessed during steady-state phenylephrine (PE) infusion superimposed by LBNP and NP to counteract the PE increased CVP and carotid sinus pressure, respectively. RESULTS: Active physical deconditioning significantly decreased maximal oxygen uptake (-7%) and LBNP tolerance (-13%) without a change in baseline hemodynamics. Plasma volume (-3% at P = 0.135), determined by Evans Blue dilution, and blood volume (-4% at P = 0.107) were not significantly altered. During LBNP -20 to -50 torr, there was a significantly greater drop of SV per unit decrease in CVP in the post- (14.7 +/- 1.6%/mm Hg) than predeconditioning (11.2 +/- 0.7%/mm Hg) test accompanied by a greater tachycardia. Deconditioning increased the aortic baroreflex sensitivity (pre vs post: -0.61 +/- 0.12 vs -0.84 +/- 0.14 bpm.mm-1 Hg, P = 0.009) and the slope of forearm vascular resistance (calculated from [MAP-CVP]/FBF) to CVP (-2.75 +/- 0.26 vs -4.94 +/- 0.97 PRU/mm Hg, P = 0.086). However, neither the CBR-HR (-0.28 +/- 0.03 VS -0.39 +/- 0.10 bpm.mm-1 Hg) nor the CBR-MAP (-0.37 +/- 0.16 vs -0.25 +/- 0.07 mm Hg/mm Hg) gains were statistically different between pre- and postdeconditioning. CONCLUSIONS: We concluded that the functional modification of the cardiac pressure-volume relationship resulted in the reduced LBNP tolerance, despite the accentuated aortic and cardiopulmonary baroreflex function following deconditioning.

Non-NASA Center↗

Vestibular influences on autonomic cardiovascular control in humans

There is substantial evidence that anatomical connections exist between vestibular and autonomic nuclei. Animal studies have shown functional interactions between the vestibular and autonomic systems. The nature of these interactions, however, is complex and has not been fully defined. Vestibular stimulation has been consistently found to reduce blood pressure in animals. Given the potential interaction between vestibular and autonomic pathways this finding could be explained by a reduction in sympathetic activity. However, rather than sympathetic inhibition, vestibular stimulation has consistently been shown to increase sympathetic outflow in cardiac and splanchnic vascular beds in most experimental models. Several clinical observations suggest that a link between vestibular and autonomic systems may also exist in humans. However, direct evidence for vestibular/autonomic interactions in humans is sparse. Motion sickness has been found to induce forearm vasodilation and reduce baroreflex gain, and head down neck flexion induces transient forearm and calf vasoconstriction. On the other hand, studies using optokinetic stimulation have found either very small, variable, or inconsistent changes in heart rate and blood pressure, despite substantial symptoms of motion sickness. Furthermore, caloric stimulation severe enough to produce nystagmus, dizziness, and nausea had no effect on sympathetic nerve activity measured directly with microneurography. No effect was observed on heart rate, blood pressure, or plasma norepinephrine. Several factors may explain the apparent discordance of these results, but more research is needed before we can define the potential importance of vestibular input to cardiovascular regulation and orthostatic tolerance in humans.

Review↗

Cerebral versus systemic hemodynamics during graded orthostatic stress in humans

BACKGROUND: Orthostatic syncope is usually attributed to cerebral hypoperfusion secondary to systemic hemodynamic collapse. Recent research in patients with neurocardiogenic syncope has suggested that cerebral vasoconstriction may occur during orthostatic hypotension, compromising cerebral autoregulation and possibly contributing to the loss of consciousness. However, the regulation of cerebral blood flow (CBF) in such patients may be quite different from that of healthy individuals, particularly when assessed during the rapidly changing hemodynamic conditions associated with neurocardiogenic syncope. To be able to interpret the pathophysiological significance of these observations, a clear understanding of the normal responses of the cerebral circulation to orthostatic stress must be obtained, particularly in the context of the known changes in systemic and regional distributions of blood flow and vascular resistance during orthostasis. Therefore, the specific aim of this study was to examine the changes that occur in the cerebral circulation during graded reductions in central blood volume in the absence of systemic hypotension in healthy humans. We hypothesized that cerebral vasoconstriction would occur and CBF would decrease due to activation of the sympathetic nervous system. We further hypothesized, however, that the magnitude of this change would be small compared with changes in systemic or skeletal muscle vascular resistance in healthy subjects with intact autoregulation and would be unlikely to cause syncope without concomitant hypotension. METHODS AND RESULTS: To test this hypothesis, we studied 13 healthy men (age, 27 +/- 7 years) during progressive lower body negative pressure (LBNP). We measured systemic flow (Qc is cardiac output; C2H2 rebreathing), regional forearm flow (FBF; venous occlusion plethysmography), and blood pressure (BP; Finapres) and calculated systemic (SVR) and forearm (FVR) vascular resistances. Changes in brain blood flow were estimated from changes in the blood flow velocity in the middle cerebral artery (VMCA) using transcranial Doppler. Pulsatility (systolic minus diastolic/mean velocity) normalized for systemic arterial pressure pulsatility was used as an index of distal cerebral vascular resistance. End-tidal PACO2 was closely monitored during LBNP. From rest to maximal LBNP before the onset of symptoms or systemic hypotension, Qc and FBF decreased by 29.9% and 34.4%, respectively. VMCA decreased less, by 15.5% consistent with a smaller decrease in CBF. Similarly, SVR and FVR increased by 62.8% and 69.8%, respectively, whereas pulsatility increased by 17.2%, suggestive of a mild degree of small-vessel cerebral vasoconstriction. Seven of 13 subjects had presyncope during LBNP, all associated with a sudden drop in BP (29 +/- 9%). By comparison, hyperventilation alone caused greater changes in VMCA (42 +/- 2%) and pulsatility but never caused presyncope. In a separate group of 3 subjects, superimposition of hyperventilation during highlevel LBNP caused a further decrease in VMCA (31 +/- 7%) but no change in BP or level of consciousness. CONCLUSIONS: We conclude that cerebral vasoconstriction occurs in healthy humans during graded reductions in central blood volume caused by LBNP. However, the magnitude of this response is small compared with changes in SVR or FVR during LBNP or other stimuli known to induce cerebral vasoconstriction (hypocapnia). We speculate that this degree of cerebral vasoconstriction is not by itself sufficient to cause syncope during orthostatic stress. However, it may exacerbate the decrease in CBF associated with hypotension if hemodynamic instability develops.

NASA Discipline Cardiopulmonary↗

Gravitoinertial force level influences arm movement control

1. The ability to move the forearm between remembered elbow joint angles immediately after rapid increases or decreases of the background gravitoinertial force (G) level was measured. The movements had been well-practiced in a normal 1G environment before the measurements in high-(1.8G) and low-force (0G) environments. The forearm and upper arm were always unsupported to maximize the influence of altered G-loading and to minimize extraneous cues about arm position. 2. Horizontal and vertical movement planes were studied to measure the effects of varying the G load in the movement plane within a given G background. Rapid and slow movements were studied to assess the role of proprioceptive feedback. 3. G level did not affect the amplitude of rapid movements, indicating that subjects were able to plan and to generate appropriate motor commands for the new G loading of the arm. The amplitude of slow movements was affected by G level, indicating that proprioceptive feedback is influenced by G level. 4. The effects of G level were similar for horizontal and vertical movements, indicating that proprioceptive information from supporting structures, such as the shoulder joint and muscles, had a role in allowing generation of the appropriate motor commands. 5. The incidence and size of dynamic overshoots were greater in 0G and for rapid movements. This G-related change in damping suggests a decrease in muscle spindle activity in 0G. A decrease in muscle spindle activity in 0G and an increase in 1.8G are consistent with the results of our prior studies on the tonic vibration reflex, locomotion, and perception of head movement trajectory in varying force backgrounds.

NASA Program Space Physiology and Countermeasures↗

Multimodal Platform Control for Robotic Planetary Exploration Missions

Planetary exploration missions pose unique problems for astronauts seeking to coordinate and control exploration vehicles. These include working in an environment filled with abrasive dust (e.g., regolith compositions), a desire to have effective hands-free communication, and a desire to have effective analog control of robotic platforms or end effectors. Requirements to operate in pressurized suits are particularly problematic due to the increased bulk and stiffness of gloves. As a result, researchers are considering alternative methods to perform fine movement control, for example capitalizing on higher-order voice actuation commands to perform control tasks. This paper presents current research at NASA s Neuro Engineering Laboratory that explores one method-direct bioelectric interpretation-for handling some of these problems. In this type of control system, electromyographic (EMG) signals are used both to facilitate understanding of acoustic speech in pressure-regulated suits 2nd to provide smooth analog control of a robotic platform, all without requiring fine-gained hand movement. This is accomplished through the use of non-invasive silver silver-chloride electrodes located on the forearm, throat, and lower chin, positioned so as to receive electrical activity originating from the muscles during contraction. For direct analog platform control, a small Personal Exploration Rover (PER) built by Carnegie Mellon University Robotics is controlled using forearm contraction duration and magnitudes, measured using several EMG channels. Signal processing is used to translate these signals into directional platform rotation rates and translational velocities. higher order commands were generated by differential contraction patterns called "clench codes."

Jorgensen, Charles↗

Gesture-Based Robot Control with Variable Autonomy from the JPL Biosleeve

This paper presents a new gesture-based human interface for natural robot control. Detailed activity of the user's hand and arm is acquired via a novel device, called the BioSleeve, which packages dry-contact surface electromyography (EMG) and an inertial measurement unit (IMU) into a sleeve worn on the forearm. The BioSleeve's accompanying algorithms can reliably decode as many as sixteen discrete hand gestures and estimate the continuous orientation of the forearm. These gestures and positions are mapped to robot commands that, to varying degrees, integrate with the robot's perception of its environment and its ability to complete tasks autonomously. This flexible approach enables, for example, supervisory point-to-goal commands, virtual joystick for guarded teleoperation, and high degree of freedom mimicked manipulation, all from a single device. The BioSleeve is meant for portable field use; unlike other gesture recognition systems, use of the BioSleeve for robot control is invariant to lighting conditions, occlusions, and the human-robot spatial relationship and does not encumber the user's hands. The BioSleeve control approach has been implemented on three robot types, and we present proof-of-principle demonstrations with mobile ground robots, manipulation robots, and prosthetic hands.

BioSleeve↗