Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frequency extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Kinematics of femtosecond laser-generated plasma expansion: Determination of sub-micron density gradient and collisionality evolution of over-critical laser plasmas

An optical diagnostic based on resonant absorption of laser light in a plasma is introduced and is used for the determination of density scale lengths in the range of 10 nm to >1 μm at the critical surface of an overdense plasma. This diagnostic is also used to extract the plasma collisional frequency, allowing inference of the temporally evolving plasma composition on the tens of femtosecond timescale. This is found to be characterized by two eras: the early time and short scale length expansion (L < 0.1λ), where the interaction is highly collisional and target material dependent, followed by a period of material independent plasma expansion for longer scale lengths (L > 0.1λ); this is consistent with a hydrogen plasma decoupling from the bulk target material. Density gradients and plasma parameters on this scale are of importance to plasma mirror optical performance and comment is made on this theme.

Scott, G. G. (ORCID:000000032772372X)↗

The impact of pulse width modulation on heat accumulation in AlGaN channel HEMTs

The poor thermal properties of Aluminum–Gallium Nitride (AlGaN) channel High Electron Mobility Transistors (HEMTs) on sapphire limit the device’s maximum switching frequency due to high channel temperatures. Extracting the correct thermal time constants can provide guidelines for the device’s safe frequency operation. This study experimentally quantifies the impact of pulse width and duty cycle on the transient thermal dynamics of multi-finger AlGaN channel HEMTs. In most transient thermal metrology, lock-in averaging approaches are leveraged to increase signal-to-noise ratio and measure the device’s relative temperature rise. Assuming no heat accumulation, the temperature rise is used to quantify the device’s thermal resistance under continued pulsed biasing. For devices grown on sapphire substrates, however, heat accumulation leads to elevated reference temperatures and causes the differential measurement to underestimate the peak temperature. This study demonstrates the capability of transient Gate Resistance Thermometry (tGRT) to measure the absolute temperature, which is required to precisely evaluate the device’s thermal resistance. When an absolute temperature measurement is not feasible (such as thermoreflectance imaging), a solution is proposed to derive the peak temperature under pulsed biasing based on the differential temperature under pulsing and the steady-state thermal resistance (which is typically easier to obtain). Finally, additional tGRT (without averaging) is performed to demonstrate the temperature-dependent thermal time constants required to minimize heat accumulation effects.

Field effect transistors↗

Dynamic mode decomposition with core sketch

With the increase in collected data volumes, either from experimental measurements or high fidelity simulations, there is an ever-growing need to develop computationally efficient tools to process, analyze, and interpret these datasets. Modal analysis techniques have gained great interest due to their ability to identify patterns in the data and extract valuable information about the system being considered. Dynamic mode decomposition (DMD) relies on elements of the Koopman approximation theory to compute a set of modes, each associated with a fixed oscillation frequency and a decay/growth rate. Extracting these details from large datasets can be computationally expensive due to the need to implement singular value decomposition of the input data matrix. Sketching algorithms have become popular in numerical linear algebra where statistical theoretic approaches are utilized to reduce the cost of major operations. A sketch of a matrix is another matrix, which is significantly smaller, but still sufficiently approximates the original system. We put forth an efficient DMD framework, SketchyDMD, based on a core sketching algorithm that captures information about the range and corange (their mutual relationship) of input data. The proposed sketching-based framework can accelerate various portions of the DMD routines, compared to classical methods that operate directly on the raw input data. We conduct numerical experiments using the spherical shallow water equations as a prototypical model in the context of geophysical flows. In conclusion, we show that the proposed SketchyDMD is superior to existing randomized DMD methods that are based on capturing only the range of the input data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-View Convolutional Neural Network for Data Spoofing Cyber-Attack Detection in Distribution Synchrophasors

Security of Distribution Synchrophasors Data (DSD) is of paramount importance as the data is used for critical smart grid applications including situational awareness, advanced protection, and dynamic control. Unfortunately, the DSD are attractive targets for malicious attackers aiming to damage grid. Data spoofing is a new class of deceiving attack, where the DSD of one Phasor Measurement Units (PMUs) is tampered by other PMUs thereby spoiling measurement based applications. In order to address this issue, a source authentication based data spoofing attack detection method is proposed using Multi-view Convolutional Neural Network (MCNN). First, common components embedded in raw frequency measurements from DSD are removed by Savitzky-Golay (SG) filter. Second, fast S transform (FST) is utilized to extract representative spatial fingerprints via time frequency analysis. Third, the spatial fingerprint is fed to MCNN, which combines dilated and standard convolutions for automatic feather extraction and source identification. Finally, according to the output of MCNN, spoofing attack detection is performed via threshold criterion. Extensive experiments with actual DSD from multiple locations in FNET/Grideye are conducted to verify the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

Sensor selection and tool wear prediction with data‐driven models for precision machining

Abstract Estimation of tool wear in precision machining is vital in the traditional subtractive machining industry to reduce processing cost, improve manufacturing efficiency and product quality. In this vein, fusion of time and frequency‐domain features of commonly sensed signals can provide an early indication of tool wear and improve its prediction accuracy for prognostics and health management. This paper presents a data‐driven methodology and a complete tool chain for the inference of precision machining tool wear from fused machine measurements, such as cutting force, power, audio and vibration signals, and quantify the usefulness of each measurement. Indicators of tool wear are extracted from time‐domain signal statistics, frequency‐domain analysis, and time‐frequency domain analysis. Correlation coefficients between the extracted features (indicators) and the tool wear are used to select the most informative features. Principal Component Analysis and Partial Least‐Squares are used to reduce the dimensionality of the feature space. Regression models, including linear regression, support vector regression, Decision tree regression, neural network regression and Gaussian process regression, are used to predict the tool wear using data from a Haas milling machine performing spiral boss face milling. The performance of the regression models based on subsets of sensors validates the preliminary estimates about the saliency of the sensors. The experimental results show that the proposed methods can predict the machine tool wear precisely, with readily available sensor measurements. Neural network and Gaussian process regression were able to achieve good estimates of tool wear at different machine operating conditions. The most informative signal in predicting tool wear was shown to be the vibration signal. Time‐frequency domain features were the most informative features among the combination of features of three domains. In addition, using partial least squares components extracted from the original features of signals led to higher prediction accuracy.

Han, Seulki↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

Unstructured clinical notes within the 24 hours since admission predict short, mid & long-term mortality in adult ICU patients

Mortality prediction for intensive care unit (ICU) patients is crucial for improving outcomes and efficient utilization of resources. Accessibility of electronic health records (EHR) has enabled data-driven predictive modeling using machine learning. However, very few studies rely solely on unstructured clinical notes from the EHR for mortality prediction. In this work, we propose a framework to predict short, mid, and long-term mortality in adult ICU patients using unstructured clinical notes from the MIMIC III database, natural language processing (NLP), and machine learning (ML) models. Depending on the statistical description of the patients’ length of stay, we define the short-term as 48-hour and 4-day period, the mid-term as 7-day and 10-day period, and the long-term as 15-day and 30-day period after admission. We found that by only using clinical notes within the 24 hours of admission, our framework can achieve a high area under the receiver operating characteristics (AU-ROC) score for short, mid and long-term mortality prediction tasks. The test AU-ROC scores are 0.87, 0.83, 0.83, 0.82, 0.82, and 0.82 for 48-hour, 4-day, 7-day, 10-day, 15-day, and 30-day period mortality prediction, respectively. We also provide a comparative study among three types of feature extraction techniques from NLP: frequency-based technique, fixed embedding-based technique, and dynamic embedding-based technique. Lastly, we provide an interpretation of the NLP-based predictive models using feature-importance scores.

60 APPLIED LIFE SCIENCES↗

Improving the Quasi‐Biennial Oscillation via a Surrogate‐Accelerated Multi‐Objective Optimization

Accurate simulation of the quasi-biennial oscillation (QBO) is challenging due to uncertainties in representing convectively generated gravity waves. We develop an end-to-end uncertainty quantification workflow that calibrates these gravity wave processes in E3SM for a realistic QBO. Central to our approach is a domain knowledge-informed, compressed representation of high-dimensional spatio-temporal wind fields. By employing a parsimonious statistical model that learns the fundamental frequency from complex observations, we extract interpretable and physically meaningful quantities capturing key attributes. Building on this, we train a probabilistic surrogate model that approximates the fundamental characteristics of the QBO as functions of critical physics parameters governing gravity wave generation. Leveraging the Karhunen–Loève decomposition, our surrogate efficiently represents these characteristics as a set of orthogonal features, capturing cross-correlations among multiple physics quantities evaluated at different pressure levels and enabling rapid surrogate-based inference at a fraction of the computational cost of full-scale simulations. Finally, we analyze the inverse problem using a multi-objective approach. Our study reveals a tension between amplitude and period that constrains the QBO representation, precluding a single optimal solution. To navigate this, we quantify the bi-criteria trade-off and generate a set of Pareto optimal parameter values that balance the conflicting objectives. This integrated workflow improves the fidelity of QBO simulations and offers a versatile template for uncertainty quantification in complex geophysical models.

54 ENVIRONMENTAL SCIENCES↗

Physics-Based Feature Extraction from Bulk Time-Series PMU Datasets for Event Detection

In this work, two physics-based feature extraction techniques are developed for bulk time-series phasor measurement unit (PMU) datasets collected from the field to train the machine learning model for anomaly detection. Two approaches have been developed to extract useful features for different types of events. An admittance-based feature extraction technique is developed to detect events that involve line outages and system topology variations. The developed algorithm extracts the system equivalent admittance variation. Additionally, Fielder’s Theory is utilized to further reduce the potential computation burden by sectionalizing large-scale grids and datasets into smaller areas. Second, an oscillation-based feature extraction technique is developed to detect low-frequency oscillations in power grids. The dominant oscillation modes in the grids are extracted using energy-sorted Prony analysis. The extracted dominant oscillation modes by the developed work exhibit a high fitting resolution. Finally, the developed techniques have been validated using large-scale and real-world datasets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Online Multivariate Signal Extraction With Locally Weighted Robust Polynomial Regression

High-frequency, multivariate data collected in real-time and used to control or make decisions regarding a process’ operation often contain some noise and outliers. Thus, a method to extract the signal is needed in order to reduce the number and magnitude of control-based adjustments that are implemented. Such a method must be (i) online, depending only on past and current observations; (ii) fast, producing a smooth value more quickly than the measurement frequency; (iii) robust, ignoring brief bursts of erroneously measured values; (iv) multivariate, ignoring observations that are jointly unusual; (v) adaptive, adjusting to periods of rapid fluctuation in the signal versus periods of stability; and (vi) purely data-driven, not incorporating any information about the process from which the data are collected. Most existing methods are only able to address a subset of these six features. Furthermore, we also require the method to be nonlinear, providing a local nonlinear estimate of the signal. In this work, we propose a novel, real-time signal extraction method based on a local, robust polynomial fit. We demonstrate the performance of our method compared to a state-of-the-art competitor through simulation. For illustration, the methodology is applied to data collected from a reverse osmosis water treatment process.

97 MATHEMATICS AND COMPUTING↗

Data source authentication of synchrophasor measurement devices based on 1D-CNN and GRU

Synchrophasor measurement devices (SMDs) have been widely deployed to support real-time monitoring and control of power systems. In the meantime, data spoofing has emerged in recent years. Therefore, it is of great importance to study data authentication algorithms for detecting and defending the data spoofing effectively. Here, a one-dimensional convolutional neural network (1D-CNN) is utilized to extract temporal signatures hidden in frequency, voltage angle and amplitude data; then the gated recurrent unit (GRU) employs these temporal signatures for data source authentication. In case studies, the performances of different algorithms are tested in large-scale power systems with numerous SMDs for the first time, and comparisons among different algorithms show that the proposed algorithm can achieve a higher accuracy of data source authentication with a shorter time window.

47 OTHER INSTRUMENTATION↗

Coherence in Polycrystalline Thin Films of Twisted Molecular Crystals

Helicoidal crystallites in rhythmically banded spherulites manifest spectacular optical patterns in small molecules and polymers. It is shown that concentric optical bands indicating crystallographic orientations typically lose coherence (in-phase twisting) with growth from the center of nucleation. Here, coherence is shown to increase as the twist period decreases for seven molecular crystals grown from the melt. This dependence was correlated to crystallite fiber thickness and length, as well as crystallite branching frequency, a parameter that was extracted from scanning electron micrographs, and supported by numerical simulations. Hole mobilities for 2,5-didodecyl-3,6-di(thiophen-2-yl)pyrrolo[3,4-c]pyrrole-1,4(2H,5H)-dione (DPP-C12) measured by using organic field-effect transistors demonstrated that more incoherent boundaries between optical bands in spherulites lead to higher charge transport for films with the same twist period. This was rationalized by combining our growth model with electrodynamic simulations. This work illustrates the emergence of complexity in crystallization processes (spherulite formation) that arises in the extra variable of helicoidal radial twisting. The details of the patterns analyzed here link the added complexity in crystal growth to the electronic and optical properties of the thin films.

36 MATERIALS SCIENCE↗

Thermal Transport and Mechanical Stress Mapping of a Compression Bonded GaN/Diamond Interface for Vertical Power Devices

Bonding diamond to the back side of gallium nitride (GaN) electronics has been shown to improve thermal management in lateral devices; however, engineering challenges remain with the bonding process and characterizing the bond quality for vertical device architectures. Here, in this study, integration of these two materials is achieved by room-temperature compression bonding centimeter-scale GaN and a diamond die via an intermetallic bonding layer of Ti/Au. Recent attempts at GaN/diamond bonding have utilized a modified surface activation bonding (SAB) method, which requires Ar fast atom bombardment immediately followed by bonding within the same tool under ultrahigh vacuum (UHV) conditions. The method presented here does not require a dedicated SAB tool yet still achieves bonding via a room-temperature metal–metal compression process. Imaging of the buried interface and the total bonding area is achieved via transmission electron microscopy (TEM) and confocal acoustic scanning microscopy (C-SAM), respectively. The thermal transport quality of the bond is extracted from spatially resolved frequency-domain thermoreflectance (FDTR) with the bonded areas boasting a thermal boundary conductance of >100 MW/m 2 ·K. Additionally, Raman maps of GaN near the GaN–diamond interface reveal a low level of compressive stress, <80 MPa, in well-bonded regions. FDTR and Raman were coutilized to map these buried interfaces and revealed some poor thermally bonded areas bordered by high-stress regions, highlighting the importance of spatial sampling for a complete picture of bond quality. Overall, this work demonstrates a novel method for thermal management in vertical GaN devices that maintains low intrinsic stresses while boasting high thermal boundary conductances.

Raman↗

Uncovering the binding nature of thiocyanate in contact ion pairs with lithium ions

Ion pair formation is a fundamental molecular process that occurs in a wide variety of systems, including electrolytes, biological systems, and materials. In solution, the thiocyanate (SCN–) anion interacts with cations to form contact ion pairs (CIPs). Due to its ambidentate nature, thiocyanate can bind through either its sulfur or nitrogen atoms, depending on the solvent. This study focuses on the binding nature of thiocyanate with lithium ions as a function of the solvents using FTIR, 2D infrared spectroscopy (2DIR) spectroscopies, and theoretical calculations. The study reveals that the SCN– binding mode (S or N end) in CIPs can be identified through 2DIR spectroscopy but not by linear IR spectroscopy. Linear IR spectroscopy shows that the CN stretch frequencies are too close to one another to separate N- and S-bound CIPs. Moreover, the IR spectrum shows that the S–C stretch presents different frequencies for the salt in different solvents, but it is related to the anion speciation rather than to its binding mode. A similar trend is observed for the anion bend. 2DIR spectra show different dynamics for N-bound and S-bound thiocyanate. In particular, the frequency–frequency correlation function (FFCF) dynamics extracted from the 2DIR spectra have a single picosecond exponential decay for N-bound thiocyanate and a biexponential decay for S-bound thiocyanate, consistent with the binding mode of the anion. Lastly, it is also observed that the binding mode also affects the line shape parameters, probably due to the different molecular mechanisms of the FFCF for N- and S-bound CIPs.

25 ENERGY STORAGE↗

Strain Gauge Diagnostic Development for use in Vessel Health Monitoring for Hydro-shots

Six-foot vessels are a crucial component to protecting high fidelity equipment at DARHT. Analysis shows these vessels have a limited life span (~10 shots) due to fatigue, ratcheting, and damage accumulation. Vessel health monitoring and diagnostics can help inform decision on a vessel’s fitness for service. Strain gauges are an easy and effective sensor for use in vessel health monitoring. In early March, J-2 executed a qualification shot, uniform blast loading with minimal fragments, with bi-axial strain gauges fielded at four locations around vessel. Several damage features were extracted from the data, and frequency content helps to validate computer modelling of the vessel response. Permanent plastic strain at each location was significant with location one having the most strain at the end state, with 230 micro-strain. However, residual pressure in the vessel could be a major factor in this strain. PEEQ is a measure of total plastic equivalent strain accumulation. The equivalent strain at location one exceeded the plastic strain limit four times and accumulated the most PEEQ with 2036 micro-strain. As expected, this qualification shot did contribute to damage in the vessel, and should be considered in its fitness for service, but not critical enough to pull it from service. Frequency content also gave valuable information on the modal response of the vessel and contributes to the understanding of how the vessel responds to the initial blast load with an expected lower frequency membrane/breathing mode and transitioning to higher frequency bending modes in the vessel wall.

42 ENGINEERING↗

Finite Element Analysis of the TRUST Nonlinear Dynamics Testbed

This paper builds on prior work conducted within the Los Alamos National Laboratory (LANL) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) program. Specifically, it builds on finite element (FE) modeling efforts for the TRUST program’s Nonlinear Dynamics (ND) testbed. Historically, the FE model for the ND testbed has exclusively utilized a Lanczos eigensolver that linearly extracts the system’s natural frequencies. This paper investigates the Abaqus 2024’s explicit dynamic solver, which implements a central difference explicit solver. The central difference method used in Abaqus can capture nonlinear material responses in structural dynamic simulations making it suitable for the ND FE model.

42 ENGINEERING↗

Linking Pharmacogenomic Information on Drug Safety and Efficacy with Ethnic Minority Populations

Numerous prescription drugs’ labeling contains pharmacogenomic (PGx) information to aid health providers and patients in the safe and effective use of drugs. However, clinical studies for such PGx biomarkers and related drug doses are generally not conducted in diverse ethnic populations. Thus, it is urgently important to incorporate PGx information with genetic characteristics of racial and ethnic minority populations and utilize it to promote minority health. In this project a bioinformatics approach was developed to enhance the collection of PGx information related to ethnic minorities to pave the way toward understanding the population-wide utility of PGx information. To address this challenge, we first gathered PGx information from drug labels. Second, we extracted data on the allele frequency information of genetic variants in ethnic minority groups from public resources. Then, we collected published research articles on PGx biomarkers and related drugs for reference. Finally, the data were integrated and formatted to build a new PGx database containing information on known drugs and biomarkers for ethnic minority groups. This database provides scientific information needed to evaluate available PGx information to enhance drug dose selection and drug safety for ethnic minority populations.

60 APPLIED LIFE SCIENCES↗