Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frisch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optical Observations of Nearby Interstellar Gas

Observations indicated that a cloud with a heliocentric velocity of approximately -28 km/s and a hydrogen column density that possibly could be on the order of, or greater than, 5 x 10 to the 19 power/square cm is located within the nearest 50 to 80 parsecs in the direction of Ophiuchus. This is a surprisingly large column density of material for this distance range. The patchy nature of the absorption from the cloud indicates that it may not be a feature with uniform properties, but rather one with small scale structure which includes local enhancements in the column density. This cloud is probably associated with the interstellar cloud at about the same velocity in front of the 20 parsec distant star alpha Oph (Frisch 1981, Crutcher 1982), and the weak interstellar polarization found in stars as near as 35 parsecs in this general region (Tinbergen 1982). These data also indicate that some portion of the -14 km/s cloud also must lie within the 100 parsec region. Similar observations of both Na1 and Ca2 interstellar absorption features were performed in other lines of sight. Similar interstellar absorption features were found in a dozen stars between 20 and 100 parsecs of the Sun.

Frisch, P. C.↗

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm 3 . The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80 %), while those evaluated using the minimum squared difference method (55-59 %) and Three Compton method (45-55 %) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of high-granularity CdZnTe pixelated detectors to correct response non-uniformities caused by defects in crystals

Following our successful demonstration of the position-sensitive virtual Frisch-grid detectors, we investigated the feasibility of using high-granularity position sensing to correct response non-uniformities caused by the crystal defects in CdZnTe (CZT) pixelated detectors. The development of high-granularity detectors able to correct response non-uniformities on a scale comparable to the size of electron clouds opens the opportunity of using unselected off-the-shelf CZT material, whilst still assuring high spectral resolution for the majority of the detectors fabricated from an ingot. Here, we present the results from testing 3D position-sensitive 15×15×10 mm 3 pixelated detectors, fabricated with conventional pixel patterns with progressively smaller pixel sizes: 1.4, 0.8, and 0.5 mm. We employed the readout system based on the H3D front-end multi-channel ASIC developed by BNL's Instrumentation Division in collaboration with the University of Michigan. We use the sharing of electron clouds among several adjacent pixels to measure locations of interaction points with sub-pixel resolution. By using the detectors with small-pixel sizes and a high probability of the charge-sharing events, we were able to improve their spectral resolutions in comparison to the baseline levels, measured for the 1.4-mm pixel size detectors with small fractions of charge-sharing events. These results demonstrate that further enhancement of the performance of CZT pixelated detectors and reduction of costs are possible by using high spatial-resolution position information of interaction points to correct the small-scale response non-uniformities caused by crystal defects present in most devices.

36 MATERIALS SCIENCE↗

Detector performance and defect densities in CdZnTe after two-step annealing

Defects both micro-scale and nano-scale are plays an important role in CdZnTe(CZT) device performance. Typical micro-scale defect, Te inclusions, was removed by two-step annealing and its concentration were analyzed by IR transmission microscopy. In addition, transmission electron microscopy (TEM) measurement was employed to investigate the evolution of nano-scale defects after annealing process. Micro-twins and stacking faults were commonly observed defects in CZT as-grown and annealed CZT. The line shape defects which possibly related to the stress field around dislocations, were combine and disappear in in-situ the annealing at 200-220 °C. Frisch-grid CZT detector made of two-step annealed one exhibit better energy resolution and low backscattering counts in Cs-137 gamma spectra.

36 MATERIALS SCIENCE↗

Instrumentation for correlated prompt n – γ emission studies in coincidence with fission fragments

Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of CdZnTeSe as a high-quality gamma-ray spectroscopic material with better compositional homogeneity and reduced defects

X- and gamma-ray detectors have broad applications ranging from medical imaging to security, non-proliferation, high-energy physics and astrophysics. Detectors with high energy resolution, e.g. less than 1.5% resolution at 662 keV at room temperature, are critically important in most uses. The efficacy of adding selenium to the cadmium zinc telluride (CdZnTe) matrix for radiation detector applications has been studied. In this paper, the growth of a new quaternary compound Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 by the Traveling Heater Method (THM) is reported. The crystals possess a very high compositional homogeneity with less extended defects, such as secondary phases and sub-grain boundary networks. Virtual Frisch-grid detectors fabricated from as-grown ingots revealed ~0.87-1.5% energy resolution for 662-keV gamma rays. The superior material quality with a very low density of defects and very high compositional homogeneity heightens the likelihood that Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 will be the next generation room-temperature detector material.

36 MATERIALS SCIENCE↗

Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors

Abstract Both material quality and detector performance have been steadily improving over the past few years for the leading room temperature radiation detector material cadmium-zinc-telluride (CdZnTe). However, although tremendous progress being made, CdZnTe still suffers from high concentrations of performance-limiting defects, such as Te inclusions, networks of sub-grain boundaries and compositional inhomogeneity due to the higher segregation coefficient of Zn. Adding as low as 2% (atomic) Se into CdZnTe matrix was found to successfully mitigate many performance-limiting defects and provide improved compositional homogeneity. Here we report record-high performance of Virtual Frisch Grid (VFG) detector fabricated from as-grown Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 ingot grown by the Traveling Heater Method (THM). Benefiting from superior material quality, we achieved superb energy resolution of 0.77% at 662 keV (as-measured without charge-loss correction algorithms) registered at room temperature. The absence of residual thermal stress in the detector was revealed from white beam X-ray topographic images, which was also confirmed by Infra-Red (IR) transmission imaging under cross polarizers. Furthermore, neither sub-grain boundaries nor their networks were observed from the X-ray topographic image. However, large concentrations of extrinsic impurities were revealed in as-grown materials, suggesting a high likelihood for further reduction in the energy resolution after improved purification of the starting material.

36 MATERIALS SCIENCE↗

Studies of fission fragment properties at the Los Alamos Neutron Science Center (LANSCE)

Nuclear data related to the fission process are needed for a wide variety of research areas, including fundamental science, nuclear energy and non-proliferation. While some of the relevant data have been measured to the required accuracies there are still many aspects of fission that need further investigation. One such aspect is how Total Kinetic Energy (TKE), fragment yields, angular distributions and other fission observables depend on excitation energy of the fissioning system. Another question is the correlation between mass, charge and energy of fission fragments. At the Los Alamos Neutron Science Center (LANSCE) we are studying neutron-induced fission at incident energies from thermal up to hundreds of MeV using the Lujan Center and Weapons Neutron Research (WNR) facilities. Advanced instruments such as SPIDER (time-of-flight and kinetic energy spectrometer), the NIFFTE Time Projection Chamber (TPC), and Frisch grid Ionization Chambers (FGIC) are used to investigate the properties of fission fragments, and some important results for the major actinides have been obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Statistical properties of ideal three-dimensional Hall magnetohydrodynamics: The spectral structure of the equilibrium ensemble

The nonlinear dynamics of ideal, incompressible Hall magnetohydrodynamics (HMHD) is investigated through classical Gibbs ensemble methods applied to the finite Galerkin representation. The spectral structure of HMHD is derived in a three-dimensional periodic geometry and compared with the MHD case. This provides a general picture of spectral transfer and cascade by the assumption that ideal Galerkin HMHD follows equilibrium statistics as in the case of Euler [U. Frisch et al., J. Fluid Mech. 68, 769 (1975)] and MHD [T. Stribling and W. H. Matthaeus, Phys. Fluids B 2, 1979 (1990)] theories. In HMHD, the equilibrium ensemble is built on the conservation of three quadratic invariants: The total energy, the magnetic helicity, and the generalized helicity. The latter replaces the cross helicity in MHD. In HMHD equilibrium, several differences appear with respect to the MHD case: (i) The generalized helicity (and in a weaker way the energy and the magnetic helicity) tends to condense in the longest wavelength, as in MHD, but also admits the novel feature of spectral enhancement, not a true condensation, at the smallest scales; (ii) equipartition between kinetic and magnetic energy, typical of Alfvenic MHD turbulence, is broken; (iii) modal distributions of energy and helicities show minima due to the presence of the ion skin depth. Ensemble predictions are compared to numerical simulations with a low-order truncation Galerkin spectral code, and good agreement is seen. Implications for general turbulent states are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experiments to Further the Understanding of the Triple-Alpha Process in Hot Astrophysical Scenarios

In astrophysics, the first excited 0{sup +} state of {sup 12}C at 7.654 MeV (Hoyle state) is the most important in the triple-{alpha} process for carbon nucleosynthesis. In explosive scenarios like supernovae, where temperatures of several 10{sup 9} K are achieved, the interference of the Hoyle state with the second 0{sup +} state located at 10.3 MeV in {sup 12}C becomes significant. The recent NACRE compilation of astrophysical reaction rates assumes a 2{sup +} resonance at 9.1 MeV for which no experimental evidence exists. Thus, it is critical to explore in more detail the 7-10 MeV excitation energy region, especially the minimum between the two 0{sup +} resonances for carbon nucleosynthesis. The states in {sup 12}C were populated through the {beta}-decay of {sup 12}B and {sup 12}N produced at the ATLAS (Argonne Tandem Linac Accelerator System) in-flight facility. The decay of {sup 12}C into three alphas is detected in a Frisch grid twin ionization chamber, acting as a low-threshold calorimeter. This minimizes the effects of {beta}-summing and allowed us to investigate the minimum above the Hoyle state with much higher accuracy than previously possible. A detailed data analysis will include an R-matrix fit to determine an upper limit on the 2{sup +} resonance width.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thickness scalability of large volume cadmium zinc telluride high resolution radiation detectors

This work focuses on the thickness scalability of traveling heater method (THM) grown CdZnTe crystals to produce large volume detectors with optimized spectroscopic performance. To meet this challenge, we have tuned both our THM growth process, to grow 75 mm diameter ingots, and our postgrowth annealing process. We have increased the thickness of our sliced wafers from 6 to 12 and 18 mm allowing the production of 10 and 15 mm thick detectors. As the detectors' thickness is scaled up, the energy resolution of both types, as pseudo-Frisch grid and pixelated monolithic detectors showed no degradation indicating improved materials uniformity and transport properties.

36 MATERIALS SCIENCE↗

DSP Algorithms for Fission Fragment and Prompt Fission Neutron Spectroscopy

Digital signal processing (DSP) algorithms are in high demand for modern nuclear fission investigation due to importance of increase the accuracy of fissile nuclear data for new generation of nuclear power stations. DSP algorithms for fission fragment (FF) and prompt fission neutron (PFN) spectroscopy are described in the present work. The twin Frisch-grid ionization chamber (GTIC) is used to measure the kinetic energy-, mass- and angular distributions of the FF in the {sup 252}Cf(SF) reaction. Along with the neutron time-of-flight (TOF) measurement the correlation between neutron emission and FF mass and energy is investigated. The TOF is measured between common cathode of the GTIC and the neutron detector (ND) pulses. Waveform digitizers (WFD) having 12 bit amplitude resolution and 100 MHz sampling frequency are used for the detector pulse sampling. DSP algorithms are developed as recursive procedures to perform the signal processing, similar to those available in various nuclear electronics modules, such as constant fraction discriminator (CFD), pulse shape discriminator (PSD), peak-sensitive analogue-to-digital converter (pADC) and pulse shaping amplifier (PSA). To measure the angle between FF and the cathode plane normal to the GTIC a new algorithm is developed having advantage over the traditional analogue pulse processing schemes. Algorithms are tested by comparing the numerical simulation of the data analysis of the {sup 252}Cf(SF) reaction with data available from literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Method of Prompt Fission Neutron Energy Spectrum Unfolding

The prompt neutron emission in spontaneous fission of {sup 252}Cf has been investigated applying digital signal electronics along with associated digital signal processing algorithms. The goal was to find out the reasons of a long time existing discrepancy between theoretical calculations and the measurements of prompt fission neutron (PFN) emission dependence on the total kinetic energy (TKE) of fission fragments (FF). On the one hand the {sup 252}Cf(sf) reaction is one of the main references for nuclear data, on the other hand the understanding of PFN emission mechanism is very important for nuclear fission theory. Using a twin Frisch-grid ionization chamber for fission fragment (FF) detection and a NE213-equivalent neutron detector in total about 10{sup 7} fission fragment-neutron coincidences have been registered. Fission fragment kinetic energy, mass and angular distribution, neutron time-of-flight and pulse shape have been investigated using a 12 bit waveform digitizer. The signal waveforms have been analyzed using digital signal processing algorithms. For the first time the dependence of the number of emitted neutrons as a function of total kinetic energy (TKE) of the fragments is in very good agreement with theoretical calculations in the range of TKE from 140-220 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unipolar time-differential charge sensing in non-dispersive amorphous solids

The use of high resistivity amorphous solids as photodetectors, especially amorphous selenium, is currently of great interest because they are readily produced over large area at substantially lower cost compared to grown crystalline solids. However, amorphous solids have been ruled out as viable radiation detection media for high frame-rate applications, such as single-photon-counting imaging, because of low carrier mobilities, transit-time-limited photoresponse, and consequently, poor time resolution. To circumvent the problem of poor charge transport in amorphous solids, we propose unipolar time-differential charge sensing by establishing a strong near-field effect using an electrostatic shield within the material. For the first time, we have fabricated a true Frisch grid inside a solid-state detector by evaporating amorphous selenium over photolithographically prepared multi-well substrates. The fabricated devices are characterized with optical, x-ray, and gamma-ray impulse-like excitations. Results prove the proposed unipolar time-differential property and show that time resolution in non-dispersive amorphous solids can be improved substantially to reach the theoretical limit set by spatial spreading of the collected Gaussian carrier cloud.

36 MATERIALS SCIENCE↗

Growth and characterization of detector-grade CdMnTe by the vertical Bridgman Technique

Here, we grew Cd1-xMnxTe crystals with a nominal Mn concentration of 5% by the vertical Bridgman growth technique. The compositional variation along the length of the grown ingot was studied by powder X-ray diffraction. The composition was found to be uniform along the growth direction. The achieved resistivity was 1-2.5 x10 10 ohm-cm with a mobility-lifetime (μτ) product value for electrons of ~1.7x10 -3 cm 2 /V. An energy resolution of ~7.5% at 662 keV was achieved or a 9-mm long Frisch grid detector fabricated from an ingot grown using as-received starting materials.

36 MATERIALS SCIENCE↗

Critical Assemblies: Dragon Burst Assembly and Solution Assemblies

This work reviews the historical literature associated with the Dragon experiment and water boiler reactors operated at Los Alamos during the Manhattan Project. Frisch’s invited talk given at the American Nuclear Society’s Fast Burst Reactor Conference held at the University of New Mexico in Albuquerque, New Mexico, in 1969 is quoted. From the literature review, basic models for the Dragon experiment and for a water boiler–type assembly (aqueous homogeneous reactor) were created that can be used for conducting multiphysics simulations for criticality excursion studies. This methodology utilizes the coupled neutronic-hydrodynamic method to perform a time-dependent dynamic simulation of a criticality excursion. MCNP® was utilized to calculate important nuclear kinetic parameters that were incorporated into the models. Simulation results compare reasonably well with historic data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗