Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fuel Loading Approach to Critical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Integrated protonic ceramic electrochemical cell for sustainable energy economy using water-energy nexus framework

Reliance on fossil fuels will continue for the next decades even though there are global pushes away from it to mitigate the overarching climate challenge, most especially by its highest consumers and availability. While there is a hastening global shift away from fossil fuel, integrating its assets into this technology helps limit the risk and future losses of stranded assets and reduce the cost of investment in the new technologies. Moreover, the generation of electricity from intermittent renewable sources like solar and wind has witnessed a significant surge in recent years, leading to a pressing demand for practical energy storage systems. Electrical energy storage is anticipated to play a pivotal role in the future global energy system, facilitating load-leveling operations to support the greater integration of renewable and distributed generation. Reversible electrochemical cells (RECs) offer a promising option for addressing the fossil fuel assets integration and energy storage challenges through the interconversion between electrical and chemical energy and concurrent utilizing carbon emission. In their electrolysis mode, the RECs convert electricity into durable, storable, and portable valuable chemical fuels such as syngas and methane. Conversely, the produced chemical fuels can be used as reactants in the fuel cell mode to generate electricity on demand with minimal (hydrocarbons) or zero when H2 or NH3 is used emissions. However, a challenging goal for this type of technology remains to achieve optimal operation and high roundtrip efficiencies, which has hindered the deployment of previous electrochemical cells. This dissertation demonstrates how reversible protonic ceramic electrochemical cells (RePCECs) can be integrated with fossil fuel power plants and renewable energy sources as a potential energy storage system. In this work, integrated RePCEC systems are designed and examined using computational modeling at scales to determine appropriate system configurations and operating conditions that achieve high roundtrip efficiencies. Cell level design of the PCEC is the first approach, several cells are assembled for the stack level model that is integrated into combined cycle powerplant and solar photovoltaic for the system level model. After critical literature review, this answered the operational and integration research questions proposed to address these challenges. The designed systems perform two functions, utilizing captured CO2 and storing renewable energy through co-electrolysis of steam and CO2. The co-electrolysis reaction involves endothermic water electrolysis and exothermic methanation reaction. To enhance high roundtrip efficiency, there is a need for thermal balance and management in the electrolysis mode. This involves operating the RePCEC stack under conditions that favor methane production to balance out heat needed by water electrolysis, it crucial for the RePCEC system operation. Methanation is enhanced by low temperatures. Leveraging on fabricated BCZYYb-electrolyte RePCEC, the cell model designed revealed that the optimum temperature for methane production is 450℃ at atmospheric pressure. Thus, to achieve optimum system performance, operating in the temperature range 450-525℃ is recommended at the given configuration, combining between the optimum temperature for methane production and temperature for the optimum stack roundtrip efficiency. Configuration with carbon capture system and purge stream is the optimum configuration from the seven conceptualized and evaluated. The modeling outcomes include a thermodynamic examination of integrated RePCEC systems, calibration of cell and stack level models, and steady-state simulation and integration into a 600MW combined cycle power plant retrofitted with two two-stage membrane-based carbon capture system and a wastewater treatment and recovery unit. At 100% powerplant loading, the stack and system roundtrip efficiencies are 72% and 51.37% respectively. Adding a purge stream for produced hydrogen at the system downstream improves the efficiencies to 74 and 55.48% respectively. At atmospheric pressure and 525℃, the system model suggests that a stack roundtrip of 82% is achievable, and overall system efficiency increases by reducing the energy consumption by the balance of plant components for steam generation and storage. Economic analysis of the process gives levelized cost of methane as $2.24/MMBtu lower than the conventional production route that range between $3.46/MMBtu and $9.85/MMBtu. The lifecycle analysis shows that the global warming potential for the production of methane and hydrogen from the RePCEC system is 3.83 kg CO2 eq which is lower than 9.35 kg CO2 eq emission during steam methane reforming for hydrogen production. This answered both the environmental and economic concerns in the raised research question. The proposed RePCEC configuration and analysis carried out in this dissertation to address the surge in renewable energy and challenges with PCEC technology hold significant potential in achieving large-scale energy storage while simultaneously reducing carbon emissions. These advancements, coupled with suitable governmental policies and incentive programs, have the potential to economically disrupt the natural gas industries by using RePCEC systems for methane production, thereby making them more favorable for eventual implementation and commercialization.

25 ENERGY STORAGE↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Independent Confirmatory Survey Summary and Results for the Enrico Fermi Atomic Power Plant, Unit 1, Newport, Michigan (Final Report No. 2)

The Enrico Fermi Atomic Power Plant, Unit 1 (Fermi 1) was a fast breeder reactor design that was cooled by sodium and operated at essentially atmospheric pressure. On May 10, 1963, the Atomic Energy Commission (AEC) granted an operating license, DPR-9, to the Power Reactor Development Company (PRDC), a consortium specifically formed to own and operate a nuclear reactor at the Fermi 1 site. The reactor was designed for a maximum capability of 430 megawatts (MW); however, the maximum reactor power with the first core loading (Core A) was 200 MW. The primary system was filled with sodium in December 1960 and criticality was achieved in August 1963. The reactor was tested at low power during the first couple years of operation. Power ascension testing above 1 MW commenced in December 1965 immediately following the receipt of a high-power operating license. In October 1966 during power ascension, zirconium plates at the bottom of the reactor vessel became loose and blocked sodium coolant flow to some fuel subassemblies. Two subassemblies started to melt and the reactor was manually shut down. No abnormal releases to the environment occurred. Forty-two months later after the cause had been determined, cleanup completed, and the fuel replaced, Fermi 1 was restarted. However, in November 1972, PRDC made the decision to decommission Fermi 1 as the core was approaching its burn-up limit. The fuel and blanket subassemblies were shipped off-site in 1973. Following that, the secondary sodium system was drained and sent off-site. The radioactive primary sodium was stored on-site in storage tanks and 55 gallon (gal) drums until it was shipped off-site in 1984. The initial decommissioning of Fermi 1 was completed in 1975. Effective January 23, 1976, DPR-9 was transferred to the Detroit Edison Company (DTE) as a 'possession only' license (DTE 2010a). This report details the confirmatory activities performed during the second Oak Ridge Institute for Science and Education (ORISE) site visit to Fermi 1 in November 2010. The survey was strategically planned during a Unit 2 (Fermi 2) outage to take advantage of decreased radiation levels that were observed and attributed to Fermi 2 from the operating unit during the first site visit. However, during the second visit there were elevated radiation levels observed and attributed to the partially dismantled Fermi 1 reactor vessel and a waste storage box located on the 3rd floor of the Fermi 1 Turbine Building. Confirmatory surveys (unshielded) performed directly in the line of sight of these areas were affected. The objective of the confirmatory survey was to verify that the final radiological conditions were accurately and adequately described in Final Status Survey (FSS) documentation, relative to the established release criteria. This objective was achieved by performing document reviews, as well as independent measurements and sampling. Specifically, documentation of the planning, implementation, and results of the FSS were evaluated; side-by-side FSS measurement and source comparisons were performed; site areas were evaluated relative to appropriate FSS classification; and areas were assessed for residual, undocumented contamination.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ultrafine Pt cluster and RuO 2 heterojunction anode catalysts designed for ultra-low Pt-loading anion exchange membrane fuel cells

Development of high-performance hydrogen oxidation catalysts with ultralow precious metal loading is critical to the development of next-generation anion-exchange membrane fuel cells. In this work, a novel Ru-rich Pt–RuO 2 heterojunction catalyst was synthesized via a solvothermal process followed by thermal treatment. The Pt–RuO 2 catalyst has ultrafine Pt clusters and a heterojunction interface between Pt and RuO 2 , which facilitates high hydrogen oxidation activity while minimizing adverse adsorption of the phenyl group in the polymer electrolyte. The performance of a membrane electrode assembly employing the Pt–RuO 2 /C reached a peak power density of 0.77 W cm -2 with an anode Pt loading of 25 μg Pt cm -2 , achieving a specific power of 31 W mg Pt -1 under H 2 /O 2 conditions. The combined analysis of electrode performance and cost indicates that Pt–RuO 2 /C is one of the most promising catalysts that is approaching the U.S. DOE 2020 performance and cost targets for transportation applications.

25 ENERGY STORAGE↗

Assessment of Core Physics Characteristics of Extended Enrichment and Higher Burnup LWR Fuels using the Polaris/PARCS Two-Step Approach. Vol. I: PWR Fuel

Nuclear fuel with extended enrichment (235U enrichment within 5-8 wt%) is one of the evolutionary changes that have been pursued in recent years by commercial light water reactor operators and fuel vendors to improve the fuel cycle economy and operation performance of a nuclear plant. This work assesses the performance of the Polaris/PARCS two-step approach in core physics modeling of the pressurized water reactor cores with extended enrichment fuel, referred to as “LEU+” in this report. A representative LEU+ core with a 24-month fuel cycle developed by Southern Nuclear Company (SNC) was modeled using this two-step approach. A representative LEU core with an 18-month fuel cycle was also modeled to provide a reference for the LEU+ core. As expected, significantly more burnable poison absorbers were used in the LEU+ core to accomodate its higher fuel enrichment. Nine different fuel assembly types were modeled using Polaris for each core to generate the assembly cross sections, which were then processed by GenPMAX to prepare the cross-section data for PARCS. The average specific powers of each fuel batch in each core were derived from VERA results and higher specific powers in fresh assemblies were found in the LEU core due to its less total uranium loading included in the VERA LEU model, given that the total core power was assumed to be the same for both cores. PARCS models were developed to simulate the steady-state operations of both cores. PARCS results on the LEU+ core were first compared with the VERA results for verification purpose; good agreements were seen in soluble boron and burnup distribution results, indicating that the Polaris/PARCS modeling and simulation were correctly implemented. Core physics parameters calculated by PARCS, at zero power physics tests, beginning of cycle (BOC), and end of cycle conditions (EOC), were compared between the LEU+ core and the LEU core, including soluble boron concentration, burnup distributions, assembly and pin power peaking factors, fuel temperature reactivity coefficients, moderator temperature and density reactivity coefficients, control rod worth, and shut down margin. The main differences in PARCS results between the LEU+ and the LEU cores are summarized below: 1)The critical boron concentrations were found to be much higher in the LEU+ core than in the LEU core (1582 vs. 1335 ppm for peak values). 2)Higher assembly radial power peaking factors (1.4 vs. 1.3 for peak values), 2D pin peaking factors (1.53 vs. 1.42 for peak values), and 3D pin peaking factors (1.89 vs. 1.81 for peak values) were found in the LEU+ core than in the LEU core. 3)Significantly higher reactivity coefficients of moderator temperature (and density) were found in LEU+ than in LEU.4)Significantly lower control rod worth at EOC were found in LEU+ than LEU for all but one control banks.5)Significantly lower shut down margins were found in the LEU+ core than in the LEU core. The Polaris/GenPMAX/PARCS code suite was found to be capable of modeling the LEU+ PWR core for steady-state operations and no unexpected results in core physics parameters were observed, in spite of that a) several bugs in PARCS were identified and workarounds were used; b) several features were found lacking in the current version of PARCS that would be useful for core modeling. A list of requests for bug fixes and feature upgrades for PARCS originated from this work were transmitted to the code developers. The assessments on the performance of the Polaris/PARCS two-step approach in core modeling for boiling water reactor with LEU+ fuel is ongoing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Study of Iodine Gas Removal in Sodium Pools

Potential iodine gas release from failed fuel pins is a critical factor in the source term analysis of oxide fuel-loaded sodium fast reactors (SFRs). The accumulated iodine-containing gas mixtures inside pin plenums are expected to be ejected during pin failures and rise through sodium pool, with potential release of gaseous iodine to the cover gas region. Due to its potential radiological impacts, a proper assessment of iodine behavior is necessary for an accurate source term assessment. Throughout the bubble rise trajectory in the sodium pool, iodine gas is continuously removed or transformed at the bubble interface by diffusion, as the combining reaction between the iodine and sodium to form sodium iodide (NaI) is a chemically preferred process. As the final amount of iodine released from the facility is strongly influenced by the removal phenomenon inside the sodium pool, experiments were previously performed by PNC (Power Reactor and Nuclear Fuel Development Corporation) to provide insight into this phenomenon. To assess the accuracy of present methods for predicting iodine gas removal within sodium pools, several candidate approaches, available in source term analysis codes, have been summarized and evaluated in this study. Spherical cap bubbles and spherical bubbles are considered in accordance with the methods adopted in each approach, and different forms of correlations for major parameters have been implemented in accordance with the original adoptions. Based on the summarized results, important aspects to be considered have been derived.

Decontamination↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel Hybrid Microbial Electrochemical System for Efficient Hydrogen Generation from Biomass (Final Technical Report)

The overall goal of this proposal was to develop a novel microbial electrochemical system for H 2 production from biomass at a cost less than $2/kg H 2 . The specific objectives of this project were: (1) design and fabricate a low-cost, robust, and highly efficient hybrid fermentation and microbial electrochemical cell (MEC) reactor, and (2) determine the techno-economic feasibility of the system for H 2 generation from lignocellulosic biomass hydrolysates and sugar-rich wastewater. We achieved the first objective by developing a system with the following characteristics: (a) a hybrid bioreactor that combines the strengths of dark fermentation and microbial electrolysis processes; (b) novel electrode assembly in the reactor that contains robust, low-cost, efficient catalyst, electrode and separator materials; (c) optimized operational conditions that lower the energy input and enhance H 2 yield and production rate. We achieved the second objective by developing a cost-performance model to identify key factors that affect performance and cost of H 2 production and guide/prioritize research. The research conducted in this project has advanced the knowledge in the fields of dark fermentation, microbial electrochemistry and technologies, and electrocatalysis. It has enhanced our understanding of how the H 2 production is affected by the bacterial culture, feedstock composition, and environmental conditions in both dark fermentation and MEC processes and what are the key microbial processes that hinder the H 2 production using single chamber MEC reactors and mixed bacterial cultures. The research has revealed the synthesis-structure-property relationship of a H 2 evolution reaction (HER) catalyst. This proposed technology represents a green and renewable approach for H 2 production from biomass. The biomass harvested in the country could provide enough H 2 to fuel light-duty vehicles in the US. When using wastewater as feedstock, the simultaneous wastewater treatment during H 2 production process can further increase the environmental sustainability. The research conducted in this project has brought the biological H 2 production technologies closer to practical applications by: 1) determining the suitable mixed bacterial cultures using complex feedstocks; 2) developing fermentative bacterial enrichment and immobilization methods for enhancing the H 2 production rate; 3) developing low-cost molybdenum phosphide (MoP) HER catalysts to lower the capital cost; 4) determining the suitable design (e.g. reactor configuration, electrode surface area to rector volume ratio, liquid/gas separator) and operational conditions (e.g. pH, temperature, feedstock loading, mixing conditions) to lower the capital and operational costs; 5) fabricating a 10-L hybrid reactor to demonstrate the potential of H 2 production. Our cost performance analysis suggests that further increasing the current density and reducing the electrode costs are critical to meet the $2/kg cost target using lignocellulosic biomass feedstock and the cost target is achievable using wastewater as feedstock if the wastewater treatment credit is considered.

08 HYDROGEN↗

Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation

The University of Kentucky (UKy) project titled “Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation”, DE-FE0031757, was conducted from 8/15/2019 to 8/14/2024 in two Budget Periods. Other participants included PPL Corporation and Black Dragon Double Boiler. The overall goal was to investigate the proposed self-cleaning technology to achieve ash fouling free air preheater operation in a coal-fired power plant, especially during deep cycling. All project deliverables, milestones, and success criteria were met. UKy obtained the following scientific findings. • Temporary and periodic high temperature of heating elements (450 ~ 500 °F) can prevent ash accumulation and maintain air preheater free of clogging. • The ash samples analysis and unit operation provide solid evidence of ABS formed during low load with SCR ammonia slip being the major cause of ash accumulation, and air preheater clogging can be prevented by raising the heating element temperature up to 450 °F~ 500 °F at which ABS is decomposed. • In-situ self-cleaning can be controlled by monitoring temperature and/or presetting fixed number of cleanings per day. Both approaches in pilot testing show positive results for maintaining an ash free state for the air preheater. • Temperature criteria (cold end or gas outlet temperature) for entering self-cleaning service is critical to balance the number of cleaning cycles with maintaining the ash level. • Temperature criteria (cold end or gas outlet temperature) for exiting self-cleaning service is critical to balance the duration of the cleaning cycles with maintaining the ash level.

01 COAL, LIGNITE, AND PEAT↗

Ice-Crystallization Kinetics in the Catalyst Layer of a Proton-Exchange-Membrane Fuel Cell

Nucleation and growth of ice in the catalyst layer of a proton-exchange-membrane fuel cell (PEMFC) are investigated using isothermal differential scanning calorimetry and isothermal galvanostatic cold-starts. Isothermal ice-crystallization rates and ice-nucleation rates are obtained from heat-flow and induction-time measurements at temperatures between 240 and 273 K for four commercial carbon-support materials with varying ionomer fraction and platinum loading. Measured induction times follow expected trends from classical nucleation theory and reveal that the carbon-support material and ionomer fraction strongly impact the onset of ice crystallization. Conversely, dispersed platinum particles play little role in ice crystallization. Following our previous approach, a nonlinear ice-crystallization rate expression is obtained from Johnson-Mehl-Avrami-Kolmogorov (JMAK) theory. A validated rate expression is now available for predicting ice crystallization within water-saturated catalyst layers. Using a simplified PEMFC isothermal cold-start continuum model, we compare cell-failure time predicted using the newly obtained rate expression to that predicted using a traditional thermodynamic-based approach. From this comparison, we identify conditions under which including ice-crystallization kinetics is critical and elucidate the impact of freezing kinetics on low-temperature PEMFC operation. The numerical model illustrates that cell-failure time increases with increasing temperature due to a longer required time for ice nucleation. Hence, ice-crystallization kinetics is critical when induction times are long (i.e., in the "nucleation-limited" regime for T > 263 K). Cell-failure times predicted using ice-freezing kinetics are in good agreement with the isothermal cold-starts, which also exhibit long and distributed cell-failure times for T > 263 K. These findings demonstrate a significant departure from cell-failure times predicted using the thermodynamic-based approach.

Dursch, T. J.↗

Fossil fleet transition with fuel changes and large scale variable renewable integration

Variability in demand as seen by grid-connected dispatchable generators can increase due to factors such as greater production from variable generation assets (for example, wind and solar), increased reliance on demand response or customer-driven automation, and aggregation of loads. This variability results a need for these generators to operate in a range of different modes, collectively referred to as “flexible operations.” This study is designed to inform power companies, researchers, and policymakers of the scope and trends in increasing levels of flexible operations as well as reliability challenges and impacts for dispatchable assets. Background Because there is rarely a direct monetization of the value of operational flexibility, the decision to provide such flexibility is typically dependent on unit- and region-specific decisions made by asset owners. It is very likely that much greater and more widespread flexible operations capabilities will be needed due to increased variability in demand seen by grid-connected generators, uncertainty regarding investment in new units to provide adequate operational flexibility, and the retirement of older, uncontrolled sub-critical pulverized coal units. Objective To enhance understanding of the technical challenges and operational impacts associated with dispatchable assets needed to increase operational flexibility and support variable demand. Approach The study approach consists of three elements: a literature review of relevant prior studies, analysis of detailed scenarios for evolution of the future fleet over the next 35 years, and engineering assessment of the degree and scope of technical challenges associated with transformation to the future fleet. The study approach integrated two key elements rarely brought together in a single analysis—1) long-term capacity planning, which enables modeling of unit retirements and new asset investments, and 2) unit commitment analysis, which permits examination of hourly unit dispatch while considering operational limitations relevant to flexible operations capabilities.

James, Revis↗

Chemical Feedback in the Self-Assembly and Function of Air–Liquid Interfaces: Insight into the Bottlenecks of CO 2 Direct Air Capture

As fossil fuels remain a major source of energy throughout the world, developing efficient negative emission technologies, such as direct air capture (DAC), which remove carbon dioxide (CO 2 ) from the air, becomes critical for mitigating climate change. Although all DAC processes involve CO 2 transport from air into a sorbent/solvent, through an air–solid or air–liquid interface, the fundamental roles the interfaces play in DAC remain poorly understood. In this work, we study the interfacial behavior of amino acid (AA) solvents used in DAC through a combination of vibrational sum frequency generation spectroscopy and molecular dynamics simulations. This study revealed that the absorption of atmospheric CO 2 has antagonistic effects on subsequent capture events that are driven by changes in bulk pH and specific ion effects that feedback on surface organization and interactions. Among the three AAs (leucine, valine, and phenylalanine) studied, we identify and separate behaviors from CO 2 loading, chemical changes, variations in pH, and specific ion effects that tune structural and chemical degrees of freedom at the air–aqueous interface. The fundamental mechanistic findings described here are anticipated to enable new approaches to DAC based on exploiting interfaces as a tool to address climate change.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consequence Analysis of Residual Water in a Storage Canister - 20484

Recent observations from projects sponsored under the DOE-Nuclear Energy Spent Fuel and Waste Disposition campaign show that residual free water, well above the 0.4 gm-moles that correspond to a 3 torr rebound pressure after a 30-minute hold following prototypic drying, may remain within SNF canisters used for long-term dry storage. Specifically, experimental observations in an Integrated Research Project showed subzero temperatures and a local pocket of frozen water in a mockup fuel assembly subjected to an industry practiced drying process. In gas sampling and analysis from the High Burnup (HBU) Demonstration project, using a fully loaded and dried SNF canister, indicated presence of 100 g of residual water had remained in the canister. The effects of residual water in terms of potential adverse impacts on the condition of the SNF and the canister internals during long-term dry storage has been rigorously evaluated to address inadvertent residual water contents. The impact of residual water on the fuel and canister internals, with a focus on the oxidation of the cladding and of postulated exposed (breached-clad) fuel, were evaluated using an integrated set of time-dependent environmental conditions with semi-empirical materials oxidation models. An 'integration model,' with coupled sub-models, developed and previously used by the Center for Nuclear Waste Regulatory Analysis (CNWRA), was applied and expanded with improved sub-models for water radiolysis, and for cladding and fuel oxidations. Cladding oxidation models for various alloys were developed using the rate constants for various cladding alloys in the dry storage temperature range. A burnup-dependent fuel oxidation model was developed; it accounted for inhibition effect of fission products on fuel oxidation rates. The potential for extension of the initial breach flaw (1 mm hole) was evaluated by two separate mechanics criteria. In the first case, a critical cladding strain criterion was used. In the second case, a critical stress intensity was used to evaluate stability of a planar axial flaw postulate. A failure condition exists when a sufficient amount of fuel oxidation (at the postulated breached-clad location) causes fuel pellet swelling to load the cladding to meet a mechanics criterion for flaw extension. The integration model's results provide the following insights. The radiolysis-generated oxygen is consumed with a partitioning between the cladding and the fuel. The extent of cladding oxidation is no more than 2 μm additional consumption of the cladding metal even with 10 moles of residual water, indicating that changes in cladding conditions due to water are expected to be negligible. The conditions for cladding failure (breach opening size extension) directly correlates with the extent of fuel oxidation. Fuel oxidation significant to extend the breach could occur even with 5.5 moles of residual water. The results indicate that fuel oxidation vis-a-vis cladding oxidation is more likely under a higher radiation field, i.e., when radiolytic decomposition of the residual water occurs in few years compared to several decades, and that the conditions to cause failure are increased with fuel and cladding temperatures approaching the peak storage temperature limit of 400 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessing the life-cycle environmental impacts of the wood pallet sector in the United States

Wood pallets play a critical role in the movement and storage of goods worldwide. They are an important component in the complex global supply chain and used by almost every industry. It is therefore important to assess the environmental implications of the wood pallet supply chain and identify optimization strategies that can be implemented. In this paper, primary 2018 annual production data collected from U.S. pallet manufacturers were used to develop the first industry-average life-cycle inventory (LCI). A new functional unit was proposed to perform a more refined and accurate environmental life-cycle assessment of the wood pallet supply chain. Using the LCI data developed, a cradle-to-grave industry-average life-cycle impact assessment was performed. This novel approach quantifies environmental impacts of a generic multi-use pallet, including repair and remanufacturing. The total global warming impact was 10.4 kg CO 2 e per 45.4 t of pallet loads of product delivered using wood pallets. The manufacturing stage contributed the most, about 35%, followed by the raw material supply stage. About 41% of total primary energy consumption was from renewable sources, with most sourced from biomass. Fossil fuels comprised about 52% of the total (225 MJ per functional unit) primary energy consumption. Total environmental impact was significantly affected by two main parameters: reference service life and load-bearing capacity. Pallet repair was also found to be an important component of the wood pallet supply chain, which has a low environmental footprint compared with the overall impact of a pallet and enables mitigation of overall impact by extending the reference service life. Finally, at end-of-life, common industry practices demonstrated substantial potential environmental benefits that can minimize overall environmental impact.

54 ENVIRONMENTAL SCIENCES↗

Hybrid Analytics Solution for Power Plant Operations

Expert Microsystems, Inc., MapEx Software Inc. and XMPLR Energy LLC have teamed to submit a proposal to the US Department of Energy’s Office of Fossil Energy to improve the efficiency, reliability and flexibility of existing coal-based power plants. The project, titled Hybrid Analytics Solution to Improve Coal Power Plant Operations (the “Hybrid Analytics” project), will develop, demonstrate and commercialize a novel approach that integrates two proven real-time monitoring techniques. The Hybrid Analytics approach integrates into a single, integrated solution: a) an established, advanced data-driven analytics solution that includes artificial intelligence, advanced pattern recognition and machine-learning techniques and b) a well-proven, first principle thermal heat balance model solution. The future role of coal plants will depend on the ability to cycle and follow loads to meet marginal power demands, accommodate renewables and support the grid. Essential to success in this new role is a plant’s ability to maintain high reliability, efficiency and flexibility. However, these changing operational demands put significant stresses on power plant components that directly impact the ability to deliver these requirements. In the past, plants have independently monitored performance using physics-based solutions (heat rate, boiler losses, etc.) and reliability using data-driven analytics (advanced pattern recognition). The Hybrid Analytics solution integrates both approaches to enhance fault detection, provide automated diagnostics and estimates of remaining time to act, and provide critical, enhanced and accurate real-time information to coal plant operators. As a result, coal plants can improve efficiency, reliability, and flexibility and can cost-effectively maintain their key role in the power delivery system.

01 COAL, LIGNITE, AND PEAT↗

Grand challenges in the design, manufacture, and operation of future wind turbine systems

Abstract. Wind energy is foundational for achieving 100 % renewable electricity production, and significant innovation is required as the grid expands and accommodates hybrid plant systems, energy-intensive products such as fuels, and a transitioning transportation sector. The sizable investments required for wind power plant development and integration make the financial and operational risks of change very high in all applications but especially offshore. Dependence on a high level of modeling and simulation accuracy to mitigate risk and ensure operational performance is essential. Therefore, the modeling chain from the large-scale inflow down to the material microstructure, and all the steps in between, needs to predict how the wind turbine system will respond and perform to allow innovative solutions to enter commercial application. Critical unknowns in the design, manufacturing, and operability of future turbine and plant systems are articulated, and recommendations for research action are laid out. This article focuses on the many unknowns that affect the ability to push the frontiers in the design of turbine and plant systems. Modern turbine rotors operate through the entire atmospheric boundary layer, outside the bounds of historic design assumptions, which requires reassessing design processes and approaches. Traditional aerodynamics and aeroelastic modeling approaches are pressing against the limits of applicability for the size and flexibility of future architectures and flow physics fundamentals. Offshore wind turbines have additional motion and hydrodynamic load drivers that are formidable modeling challenges. Uncertainty in turbine wakes complicates structural loading and energy production estimates, both around a single plant and for downstream plants, which requires innovation in plant operations and flow control to achieve full energy capture and load alleviation potential. Opportunities in co-design can bring controls upstream into design optimization if captured in design-level models of the physical phenomena. It is a research challenge to integrate improved materials into the manufacture of ever-larger components while maintaining quality and reducing cost. High-performance computing used in high-fidelity, physics-resolving simulations offer opportunities to improve design tools through artificial intelligence and machine learning, but even the high-fidelity tools are yet to be fully validated. Finally, key actions needed to continue the progress of wind energy technology toward even lower cost and greater functionality are recommended.

17 WIND ENERGY↗

Hydrogen production from lignocellulosic hydrolysate in an up-scaled microbial electrolysis cell with stacked bio-electrodes

Hydrogen production from renewable resources via microbial electrolysis cells (MECs) is a promising approach for sustainable energy production. Yet high hydrogen yield from real feedstocks has not been demonstrated in up-scaled MECs. In this study, a 10-L single chamber MEC with a high electrode surface area to volume ratio (66 m 2 /m 3 ) was constructed and electroactive cathodic biofilms were enriched for hydrogen evolution reaction. A high hydrogen yield of 91% was achieved using lignocellulosic hydrolysate with a hydrogen production rate of 0.71 L/L/D at an organic loading rate of 0.4 g/D. The anodic and cathodic microbial communities, with Enterococcus spp. as the known electroactive bacteria, were capable of achieving current densities of 13.7 A/m 2 and 16.5 A/m 2 , respectively. Finally, a machine learning algorithm was used to investigate the correlation between community data and electrochemical performance, and the critical genera on determining current density were identified.

54 ENVIRONMENTAL SCIENCES↗

Integrated Vehicle Thermal Management for Advanced Vehicle Propulsion Technologies

A critical element to the success of new propulsion technologies that enable reductions in fuel use is the integration of component thermal management technologies within a viable vehicle package. Vehicle operation requires vehicle thermal management systems capable of balancing the needs of multiple vehicle systems that may require heat for operation, require cooling to reject heat, or require operation within specified temperature ranges. As vehicle propulsion transitions away from a single form of vehicle propulsion based solely on conventional internal combustion engines (ICEs) toward a wider array of choices including more electrically dominant systems such as plug-in hybrid electric vehicles (PHEVs), new challenges arise associated with vehicle thermal management. As the number of components that require active thermal management increase, so do the costs in terms of dollars, weight, and size. Integrated vehicle thermal management is one pathway to address the cost, weight, and size challenges. The integration of the power electronics and electric machine (PEEM) thermal management with other existing vehicle systems is one path for reducing the cost of electric drive systems. This work demonstrates techniques for evaluating and quantifying the integrated transient and continuous heat loads of combined systems incorporating electric drive systems that operate primarily under transient duty cycles, but the approach can be extended to include additional steady-state duty cycles typical for designing vehicle thermal management systems of conventional vehicles. The work compares opportunities to create an integrated low temperature coolant loop combining the power electronics and electric machine with the air conditioning system in contrast to a high temperature system integrated with the ICE cooling system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗