SEARCH · Search NASA
Results for “GMS”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Gelatin Microspheres: Correlation between Embolic Effect/Degradability and Cross-linkage/Particle Size
PurposeTo evaluate the embolic effect and degradability of gelatin microspheres (GMS) using various degrees of cross-linkage and particle sizes in rabbit renal artery embolization.MethodsFour types of GMS were used, as follows: 2 types of cross-linkage and 2 types of particle size. Twenty-four rabbits (6 in each group) were used for the renal artery embolization. Renal angiography was performed before and after embolization of right renal artery. Follow-up renal angiography was performed 2 days (n = 2), 5 days (n = 2), and 15 days (n = 2) after embolization in each group, and then kidneys were removed for histopathological evaluation. Vascular areas of the angiography were measured by Image J software, and the reperfusion rate was calculated. In renal specimens, residual GMS were checked and the degree of degradation was classified according to a 4-point scale.ResultsThe mean amounts of large- and small-particle-size GMS injected were 15.0 and 34.3 mg, respectively. Tissue necrosis was confirmed in each group; however, no difference was observed among groups. Renal reperfusion was observed more with small GMS than with large GMS. Renal reperfusion was also observed more with low cross-linked GMS than with high cross-linked GMS. In histopathological specimens, large GMS were confirmed in lobar artery, and small GMS were confirmed in lobular artery. Low cross-linked GMS completely degraded 15 days after embolization. In contrast, high cross-linked GMS were persistent 15 days after embolization.ConclusionDegree of cross-linkage and particle size affected degradability and reperfusion.
Enhanced Antitumor Effect of Tirapazamine Delivered Intraperitoneally to VX2 Liver Tumor-Bearing Rabbits Subjected to Transarterial Hepatic Embolization
Purpose: We evaluated the effects of the combination of Tirapazamine (TPZ), activated preferentially under hypoxic conditions, and gelatin microspheres (GMS) on the tumor growth ratio in rabbits. Methods: We assigned 20 liver tumor-bearing Japanese white rabbits to 4 equal groups. Group 1 received 1 ml of saline intra-arterially (i.a.) and 20 ml of saline intraperitoneally (i.p.; saline group). Group 2 was injected with GMS i.a. and 20 ml saline i.p. (GMS group). Group 3 received 1 ml of saline i.a. and 300 mg/m{sup 2} of TPZ i.p. (TPZ group), and group 4 was treated with GMS i.a. and 300 mg/m{sup 2} of TPZ i.p. (GMS + TPZ group). The infusion of GMS was stopped when the blood flow stagnated. Before and 7 days after treatment, the liver tumor volumes were measured as the total number of pixels on 0.3Tesla (T) magnetic resonance imaging (MRI) scans. Results: The tumor growth ratio (mean {+-} standard deviation) of the saline, GMS, TPZ, and GMS + TPZ groups was 519.15 {+-} 93.78, 279.24 {+-} 91.83, 369.78 {+-} 95.73, and 119.87 {+-} 17.62, respectively. The difference between the GMS + TPZ group and the other groups was statistically significant (P < 0.05). Conclusions: Our results show that the combination of TPZ i.p. and GMS i.a. enhanced the antitumor effect of TPZ. This procedure may represent a new alternative treatment for patients with hepatic cell carcinoma.
Interfacial defect reduction enhances universal power law response in Mo–SiNx granular metals
Granular metals (GMs), consisting of metal nanoparticles separated by an insulating matrix, frequently serve as a platform for fundamental electron transport studies. However, few technologically mature devices incorporating GMs have been realized, in large part because intrinsic defects (e.g., electron trapping sites and metal/insulator interfacial defects) frequently impede electron transport, particularly in GMs that do not contain noble metals. Here, we demonstrate that such defects can be minimized in molybdenum–silicon nitride (Mo–SiN x ) GMs via optimization of the sputter deposition atmosphere. For Mo–SiN x GMs deposited in a mixed Ar/N 2 environment, x-ray photoemission spectroscopy shows a 40%–60% reduction of interfacial Mo-silicide defects compared to Mo–SiN x GMs sputtered in a pure Ar environment. Electron transport measurements confirm the reduced defect density; the dc conductivity improved (decreased) by 10 4 –10 5 and the activation energy for variable-range hopping increased 10×. Since GMs are disordered materials, the GM nanostructure should, theoretically, support a universal power law (UPL) response; in practice, that response is generally overwhelmed by resistive (defective) transport. Here, the defect-minimized Mo–SiN x GMs display a superlinear UPL response, which we quantify as the ratio of the conductivity at 1 MHz to that at dc, Δσ ω . Remarkably, these GMs display a Δσ ω up to 10 7 , a three-orders-of-magnitude improved response than previously reported for GMs. By enabling high-performance electric transport with a non-noble metal GM, this work represents an important step toward both new fundamental UPL research and scalable, mature GM device applications.
Electrochromic Graphene Molecules
Polyclic aromatic hydrocarbons, also called Graphene Molecules (GMs), with chemical composition C 132 H 36 (COOH) 2 were synthesized in-situ on the surface of transparent nanocrystaline indium tin oxide (nc-ITO) electrodes. Their electronic structure was studied electrochemically and spectro-electrochemically. Variations in the potential applied onto the nc-ITO/GM electrodes induce only small changes in the observed current but they produce dramatic changes in the absorption of the GMs, which are associated with their oxidation and reduction. Analysis of the absorption changes using modified Nernst equation is used to determine standard potentials associated with the individual charge transfer processes. For the GMs prepared here these were found to be E 1,ox 0 = 0.77± 0.01 V and E 2,ox 0 = 1.24 ± 0.02 V vs. NHE for the first and second oxidation and E 1,red 0 = -1.50 ± 0.04 V for the first reduction. The charge transfer processes are found to be non-ideal. The non-ideality factors associated with the oxidation and reduction processes suggest presence of strong interactions between the GM redox centers. Under the conditions of potential cycling GMs show rapid (seconds) color change with high contrast and stability. An electrochromic application is demonstrated wherein the GMs are used as the optically active component.
Evidence that Horizontal Moisture Advection Regulates the Ubiquitous Amplification of Rainfall Variability over Tropical Oceans
The column moist static energy (MSE) budget equation approximates the processes associated with column moistening and drying in the tropics, and is therefore predictive of precipitation amplification and decay. We use ERA-Interim (ERA-I) and TRMM 3B42 data to investigate day-to-day convective variability and distinguish the roles of horizontal MSE (or moisture) advection versus vertical advection, sources, and sinks. Over tropical convergence zones, results suggest that horizontal moisture advection is a primary driver of day-to-day precipitation fluctuations; when drying via horizontal moisture advection is smaller (greater) than Chikira’s “column process,” precipitation tends to amplify (decay). In the absence of horizontal moisture advection, precipitation tends to increase spontaneously almost universally through a positive column process feedback. This bulk positive feedback is characterized by negative effective gross moist stability (GMS), which is maintained throughout the tropical convergence zones. How this positive feedback is achieved varies geographically, depending on the shape of vertical velocity (omega) profiles. In regions where omega profiles are top-heavy, the effective GMS is negative primarily owing to strong feedbacks between convection and diabatic MSE sources (radiative and surface fluxes). In these regions, vertical MSE advection stabilizes the atmosphere (positive vertical GMS). Where omega profiles are bottom-heavy, by contrast, a positive feedback is primarily driven by import of MSE through a shallow circulation (negative vertical GMS). The diabatic feedback and vertical GMS are in a seesaw balance, offsetting one another. Our results suggest that ubiquitous convective variability is amplified by the same mechanism as moisture-mode instability.
Effect of Radiation from Low-Level Radioactive Waste Leachate on Antioxidant Depletion in HDPE Geo-membrane - 16087
Low-level radioactive waste (LLW) and mixed waste (MW) disposal facilities in the US are required to have a service life in excess of 1000 yr. Understanding the rate of degradation of high-density polyethylene (HDPE) geo-membranes (GMs) used in LLW and MW facilities is necessary to assess their service life when conducting a performance assessment for a disposal facility. In LLW and MW disposal facilities, GMs may be exposed to radionuclides that may accelerate antioxidant depletion and degradation. This paper evaluates how radiation dosage affects antioxidant depletion in HDPE GMs and makes inferences regarding the impact of radiation on GM service life. Specimens of 0.04-mm-, 0.1-mm-, and 2-mm-thick HDPE GMs were exposed to a sealed source of Am-241 to simulate alpha radiation from LLW leachate (e.g., uranium). The specimens were exposed to the sealed source for 1-50 h, followed by oxidative induction time (OIT) testing to determine depletion of antioxidants in response to exposure. Penetration of alpha particles in the HDPE GM exposed to the sealed source was evaluated with the program Geometry And Tracking (GEANT4). The GEANT4 modeling indicates that physical dose deposition for alpha particles largely occurs on the superficial layers and decreased monotonically with depth to a negligible dose (∼ 28 μm). For a 2-mm-thick HDPE GM, there was no change in OIT after exposure, whereas in much thinner GMs (e.g., 0.04 mm), significant antioxidant depletion occurred after exposure, reflecting the shallow penetration of alpha radiation at the surface of HDPE GM. (authors)
Body burdens of brominated flame retardants and other persistent organo-halogenated compounds and their descriptors in US girls
Background: Levels of brominated flame retardants are increasing in US populations, yet little data are available on body burdens of these and other persistent hormonally active agents (HAAs) in school-aged children. Exposures to such chemicals may affect a number of health outcomes related to development and reproductive function. Objective: Determine the distribution of biomarkers of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), and organo-chlorinated pesticides (OCPs), such as DDT/DDE, in children, and their variation by key descriptor variables. Methods: Ethnically diverse cohorts of girls 6-8 y old at baseline are being followed for growth and pubertal development in a multi-site, longitudinal study. Nearly 600 serum samples from the California and Ohio sites were analyzed for lipids, 35 PCB congeners, 11 PBDE congeners, and 9 OCPs. The biomarker distributions were examined and geometric means compared for selected analytes across categories of age, race, site, body mass index (BMI), parental education, maternal age at delivery, and breast feeding in adjusted models. Results: Six PBDE congeners were detected among greater than 70% of samples, with BDE-47 having the highest concentration (median 42.2, range 4.9-855 ng/g lipid). Girls in California had adjusted geometric mean (GM) PBDE levels significantly higher than girls in Ohio. Furthermore, Blacks had significantly higher adjusted GMs of all six PBDE congeners than Whites, and Hispanics had intermediate values. GMs tended to be lower among more obese girls, while other variables were not strongly associated. In contrast, GMs of the six PCB congeners most frequently detected were significantly lower among Blacks and Hispanics than Whites. PCBs and the three pesticides most frequently detected were also consistently lower among girls with high BMI, who were not breast-fed, whose mothers were younger, or whose care-givers (usually parents) were less educated. Girls in California had higher GMs than in Ohio for the pesticides and most PCB congeners, but the opposite for CB-99 and -118. Conclusions: Several of these potential HAAs were detected in nearly all of these young girls, some at relatively high levels, with variation by geographic location and other demographic factors that may reflect exposure pathways. The higher PBDE levels in California likely reflect differences in fire regulation and safety codes, with potential policy implications.
Granular metals with SiN x dielectrics
Understanding and controlling nanoscale interface phenomena, such as band bending and secondary phase formation, is crucial for electronic device optimization. In granular metal (GM) studies, where metal nanoparticles are embedded in an insulating matrix, the importance of interface phenomena is frequently neglected. Here, we demonstrate that GMs can serve as an exemplar system for evaluating the role of secondary phases at interfaces through a combination of x-ray photoemission spectroscopy (XPS) and electrical transport studies. We investigated SiN x as an alternative to more commonly used oxide-insulators, as SiN x -based GMs may enable high temperature applications when paired with refractory metals. Comparing Co-SiN x and Mo-SiN x GMs, we found that, in the tunneling-dominated insulating regime, Mo-SiN x had reduced metal-silicide formation and orders-of-magnitude lower conductivity. XPS measurements indicate that metal-silicide and metal-nitride formation are mitigatable concerns in Mo-SiN x . Given the metal-oxide formation seen in other GMs, SiN x is an appealing alternative for metals that readily oxidize. Furthermore, SiN x provides a path to metal-nitride nanostructures, potentially useful for various applications in plasmonics, optics, and sensing.
Symmetry-Based Structured Matrices for Efficient Approximately Equivariant Networks
There has been much recent interest in designing symmetry-aware neural networks (NNs) exhibiting relaxed equivariance. Such NNs aim to interpolate between being exactly equivariant and being fully flexible, affording consistent performance benefits. In a separate line of work, certain structured parameter matrices -- those with displacement structure, characterized by low displacement rank (LDR) -- have been used to design small-footprint NNs. Displacement structure enables fast function and gradient evaluation, but permits accurate approximations via compression primarily to classical convolutional neural networks (CNNs). In this work, we propose a general framework -- based on a novel construction of symmetry-based structured matrices -- to build approximately equivariant NNs with significantly reduced parameter counts. Our framework integrates the two aforementioned lines of work via the use of so-called Group Matrices (GMs), a forgotten precursor to the modern notion of regular representations of finite groups. GMs allow the design of structured matrices -- resembling LDR matrices -- which generalize the linear operations of a classical CNN from cyclic groups to general finite groups and their homogeneous spaces. We show that GMs can be employed to extend all the elementary operations of CNNs to general discrete groups. Further, the theory of structured matrices based on GMs provides a generalization of LDR theory focussed on matrices with cyclic structure, providing a tool for implementing approximate equivariance for discrete groups. We test GM-based architectures on a variety of tasks in the presence of relaxed symmetry. We report that our framework consistently performs competitively compared to approximately equivariant NNs, and other structured matrix-based compression frameworks, sometimes with a one or two orders of magnitude lower parameter count.
Position Verification for the Prostate: Effect on Rectal Wall Dose
Purpose: To evaluate the effect of gold marker (GM)-based position correction on the cumulative dose in the anorectal wall compared with traditional bony anatomy (BA)-based correction, taking into account changes in anorectal shape and position. Methods and Materials: A total of 20 consecutive prostate cancer patients, treated with curative external beam radiotherapy, were included. Four fiducial GMs were implanted in the prostate. Positioning was verified according to the shift in BA and GMs on daily electronic portal images. Position corrections were determined using on- and off-line position verification protocols according to the position of the GMs (GM-on and GM-off) and BA (BA-off). For all patients, intensity-modulated radiotherapy plans were made for the GM (8-mm planning target volume margin) and BA (10-mm planning target volume margin) protocols. The dose distribution was recomputed on 11 repeat computed tomography scans to estimate the accumulated dose to the prostate and anorectal wall while considering internal organ motion. Results: The dose that is at least received by 99% of the prostate was, on average, acceptable for all protocols. The individual patient data showed the best coverage for both GM protocols, with >95% of the prescribed dose for all patients. The anorectal wall dose was significantly lower for the GM protocols. The dose that is at least received by 30% of the rectal wall was, on average, 54.6 Gy for GM-on, 54.1 Gy for GM-off, and 58.9 Gy for BA-off (p <.001). Conclusion: Position verification with GM and reduced planning target volume margins yielded adequate treatment of the prostate and a lower rectal wall dose, even when accounting for independent movement of the prostate and anorectal wall.
Study of non-isothermal liquid evaporation in synthetic micro-pore structures with hybrid lattice Boltzmann model
Non-isothermal liquid evaporation in micro-pore structures is studied experimentally and numerically using the lattice Boltzmann method. A hybrid thermal entropic multiple-relaxation-time multiphase lattice Boltzmann model (T-EMRT-MP LBM) is implemented and validated with experiments of droplet evaporation on a heated hydrophobic substrate. Then liquid evaporation is investigated in two specific pore structures, i.e. spiral-shaped and gradient-shaped micro-pillar cavities, referred to as SMS and GMS, respectively. In SMS, the liquid receding front follows the spiral pattern; while in GMS, the receding front moves layer by layer from the pillar rows with large pitch to the rows with small one. Both simulations agree well with experiments. Moreover, evaporative cooling effects in liquid and vapour are observed and explained with simulation results. Quantitatively, in both SMS and GMS, the change of liquid mass with time coincides with experimental measurements. The evaporation rate generally decreases slightly with time mainly because of the reduction of liquid–vapour interface. Isolated liquid films in SMS increase the evaporation rate temporarily resulting in local peaks in evaporation rate. Reynolds and capillary numbers show that the liquid internal flow is laminar and that the capillary forces are dominant resulting in menisci pinned to the pillars. Similar Péclet number is found in simulations and experiments, indicating a diffusive type of heat, liquid and vapour transport. Our numerical and experimental studies indicate a method for controlling liquid evaporation paths in micro-pore structures and maintaining high evaporation rate by specific geometry designs.
Bi-invariant functions on the group of transformations leaving a measure quasi-invariant
Let Gms be the group of transformations of a Lebesgue space leaving the measure quasi-invariant. Let Ams be a subgroup of it consisting of transformations preserving the measure. We describe canonical forms of double cosets of Gms by the subgroup Ams and show that all continuous Ams-bi-invariant functions on Gms are functionals of the distribution of a Radon-Nikodym derivative. Bibliography: 14 titles.
Deep Generative Models for Materials Discovery and Machine Learning-Accelerated Innovation
Machine learning and artificial intelligence (AI/ML) methods are beginning to have significant impact in chemistry and condensed matter physics. For example, deep learning methods have demonstrated new capabilities for high-throughput virtual screening, and global optimization approaches for inverse design of materials. Recently, a relatively new branch of AI/ML, deep generative models (GMs), provide additional promise as they encode material structure and/or properties into a latent space, and through exploration and manipulation of the latent space can generate new materials. These approaches learn representations of a material structure and its corresponding chemistry or physics to accelerate materials discovery, which differs from traditional AI/ML methods that use statistical and combinatorial screening of existing materials via distinct structure-property relationships. However, application of GMs to inorganic materials has been notably harder than organic molecules because inorganic structure is often more complex to encode. In this work we review recent innovations that have enabled GMs to accelerate inorganic materials discovery. We focus on different representations of material structure, their impact on inverse design strategies using variational autoencoders or generative adversarial networks, and highlight the potential of these approaches for discovering materials with targeted properties needed for technological innovation.
NASA follow-on on the Fiji South Pacific Severe Storm Warning System Project (SPSSD/WS)
The follow-on agreement will implement needed systems enhancements of the satellite ground station installed under the previous SPSSD/WS project. These enhancements include the purchase and installation of an Uninterruptible Power Supply (UPS) and lightning protection unit, hardware modifications to provide system redundancy and increased data storage capacity, software modifications for the new Japanese GMS digital data, upgrades of the image processing software, and both hardware maintenance and tropical cyclone analysis training, and a non-renewable grant to provide emergency field repairs and replacement/spare parts. In March 1988, the UPS and lightning protection unit was installed at the Fiji Meteorological Service by NASA personnel. A tape recorder and demodulator was shipped to Fiji to record the new digital GMS data. Data tapes are not yet available from the Japanese Meteorological Service of the new digital format. This data is required to test the GMS digital software being developed for the Fiji SPSSD/WS facility.
Signal-Conditioning Amplifier Recorders
Signal-conditioning amplifier recorders (SCAmpRs) have been proposed as a means of simplifying and upgrading the Kennedy Space Center (KSC) Ground Measurement System (GMS), which is a versatile data-acquisition system that gathers and records a variety of measurement data before and during the launch of a space shuttle. In the present version of the GMS system, signal conditioning amplifiers digitize and transmit data to a VME chassis that multiplexes up to 416 channels. The data is transmitted via a high-speed data bus to a second VME chassis where it is available for snapshots. The data is passed from the second VME chassis to a high-speed data recorder. This process is duplicated for installations at two launch pads and the Vehicle Assembly Building (VAB). Since any failure of equipment in the data path results in loss of data, much of the system is redundant. The architecture of the existing GMS limits expansion or any modification to the system to meet changing requirements because of the cost and time required. A SCAmpR-based system is much more flexible. The basis of the simplification, flexibility, and reliability is the shifting of the recording function to the individual amplifier channels. Each SCAmpR is a self-contained single channel data acquisition system, which in its current implementation, has a data storage capacity of up to 30 minutes when operating at the fastest data sampling rates. The SCAmpR channels are self-configuring and self-calibrating. Multiple SCAmpR channels are ganged on printed circuit boards and mounted in a chassis that provides power, a network hub, and Inter-Range Instrument Group (IRIG) time signals. The SCAmpR channels share nothing except physical mounting on a circuit board. All circuitry is electrically separate for each channel. All that is necessary to complete the data acquisition system is a single master computer tied to the SCAmpR channels by standard network equipment. The size of the data acquisition system dictates the requirements for the specific network equipment.