Search NASA⌕ Search

SEARCH · Search NASA

Results for “GONDOLA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Introduction to Voigt's wind power plant

The design and operation of a 100 kilowatt wind driven generator are reported. Its high speed three-bladed turbine operates at a height of 50 meters. Blades are rigidly connected to the hub and turbine revolutions change linearly with wind velocity, maintaining a constant speed ratio of blade tip velocity to wind velocity over the full predetermined wind range. Three generators installed in the gondola generate either dc or ac current. Based on local wind conditions, the device has a maximum output of 720 kilowatts at a wind velocity of 16 meters per second. Total electrical capacity is 750 kilowatts, and power output per year is 2,135,000 kilowatt/hours.

Tompkin, J.↗

Voight variable speed drive

The variable speed drive transmission is mounted within the gondola and connected with the wind turbine blades and the hub. This unit is designed for the production of ac power. The turbine turns by means of the variable speed drive and a set of synchronous three phase generators. This motion is controlled automatically by two wind rosettes in such a way that the wind turbine always opposes the wind direction. The Voight variable speed drive is a mechanical variable positive drive gear transmission. It has an unlimited power and torque transmission, a constant ratio with high degree of accuracy, a speed variation over a wide range, and a nonslip drive.

Tompkin, J.↗

Telescope Systems for Balloon-Borne Research

The proceedings of a conference on the use of balloons for scientific research are presented. The subjects discussed include the following: (1) astronomical observations with balloon-borne telescopes, (2) orientable, stabilized balloon-borne gondola for around-the-world flights, (3) ultraviolet stellar spectrophotometry from a balloon platform, (4) infrared telescope for balloon-borne infrared astronomy, and (5) stabilization, pointing, and command control of balloon-borne telescopes.

Swift, C.↗

A cooled telescope for infrared balloon astronomy

The characteristics of a 16 inch liquid helium cooled Cassegrain telescope with vibrating secondary mirror are discussed. The telescope is used in making far infrared astronomical observations. The system houses several different detectors for multicolor photometry. The cooled telescope has a ten to one increase in signal-to-noise ratio over a similar warm version and is installed in a high altitude balloon gondola to obtain data on the H2 region of the galaxy.

Frederick, C.↗

Evaluation of image quality in a Cassegrain-type telescope with an oscillating secondary mirror

A ray-trace analysis is described of aberrations and extreme rays of a Cassegrain-type telescope with a tilted secondary mirror. The work was motivated by the need to understand the factors limiting image quality and to assist in the design of secondary mirrors for three telescopes with oscillating secondary mirrors (OSM) used at Ames Research Center for high altitude infrared astronomy. The telescopes are a 31-cm-diameter Dall-Kirkham (elliptical primary, spherical secondary) flown aboard a Lear jet, a 71-cm balloon-borne Dall-Kirkham flown on the AIROscope gondola, and a 91-cm true Cassegrain (parabolic primary, hyperbolic secondary) flown aboard a C-141 jet transport. The optics for these telescopes were not designed specifically for OSM operation, but all have OSM's and all must be used with various detector configurations; therefore, a facility that evaluates the performance of a telescope for a given configuration is useful. The analytical expressions are summarized and results for the above systems are discussed. Details of the calculation and a discussion of the computer program are given in the appendices.

Erickson, E. F.↗

Comparison of techniques for measuring +Gz tolerance in man

Two objective methods and one subjective method for measuring +Gz tolerance (inertial vector in a head-to-foot direction) were compared on the human centrifuge. Direct eye-level blood pressure (Pa), blood flow velocity in the superficial temporal artery (Qta), and subjective visual symptoms were used to determine tolerance to rapid-onset acceleration (1 G/s) on the USAFSAM human centrifuge. Seven 'relaxed' subjects with extensive centrifuge experience were exposed to gradually increasing +Gz plateaus until the subject reported 100% loss of peripheral centrifuge gondola lights (PLL) and 50% loss of central light (CLD); viz., blackout. Zero forward Qta occurred 6 s (range 4-9 s) before subjective blackout and when mean eye-level blood pressure had reached 20 + or - 1 mm Hg (SE). The results of this study indicate that flow changes in the superficial temporal artery reflect flow changes in the retinal circulation during +Gz stress.

Krutz, R. W., Jr.↗

Balloon-borne photoionization mass spectrometer for measurement of stratospheric gases

A balloon-borne photoionization mass spectrometer used to measure stratospheric trace gases is described. Ions are created with photons from high-intensity krypton discharge lamps and a quadrupole mass analyzer is employed for ion identification. Differential pumping is achieved with liquid helium cryopumping. To insure measurement of unperturbed stratospheric air, the entire system is contained in a sealed gondola and the atmospheric sample is taken some distance away during descent. The photoionization technique allows the detection of a low ionization potential constituent, such as nitric oxide, at less than a part in one billion in the presence of the major atmospheric gases and their isotopes. Operation of the mass spectrometer system was demonstrated during a daytime flight from Palestine, Texas on 26 April 1977. The sensitivity achieved and the unique selectivity afforded by this technique offer a capability for trace constituent measurement not possible with the more conventional electron impact ionization approach.

Aikin, A. C.↗

Measurement of HO2 and other trace gases in the stratosphere using a high resolution far infrared spectrometer at 28 Km

A progress report and data analyses from the December 1980 flight are presented. The following areas are covered: (1) computer analysis of the flight spectra to obtain phase corrected, normalized sums of spectra for retrieval of atmospheric profiles; (2) study of atmospheric HF, HCl, and H2O; (3) stratospheric H2O2 and HOCl; (4) laboratory spectroscopy of HOCl; and (5) design study of a new balloon gondola. The majority of the flight data were taken in the low background mode, i.e., one input to the spectrometer looking at the sky and the other looking at a LN2 temperature blackbody. An analysis of HF stratospheric measurements was undertaken in conjunction with the HF analysis. High quality spectra showing the HOCl q-branches under optically thin conditions were also obtained.

Traub, W. A.↗

Carbon dioxide measurements in the stratosphere

A mass spectrometer experiment for the analysis of minor constituents in the stratosphere has been flown successfully four times from Palestine, Texas on board a balloon gondola. The carbon dioxide mixing ratio, which shows unexpectedly large variations in the stratosphere, reached 400 ppm in one particular night flight. This is about 20% higher than the ground value. Evidence is presented that the experiment performed well during each of the balloon flights. The isotopic ratio C-12/C-13 was measured and found in good agreement with previous air analyses showing a depletion of C-13.

Mauersberger, K.↗

A 102 cm balloon-borne telescope for far-infrared astronomical observations

In early 1971, a program was initiated to develop a balloon-borne 102-cm telescope, capable of carrying out far-infrared observations of astronomical interest above the earth's atmosphere in the wavelength range from 40 to 250 micrometers. Since 1972 the telescope has been flown and successfully recovered a total of sixteen times. Ten of the flights have produced high quality astronomical data, resulting in more than 80 hours of photometric and spectroscopic observations of numerous objects, such as H II regions, dark clouds, molecular clouds, X-ray sources, galaxies, the galactic center, planets, the Moon, and an asteroid. Attention is given to the telescope optics, the gondola, altitude control, the auxiliary attitude control system, the determination of telescope pointing position, telemetry, power requirements, the flight record, and the four instruments which are available for use on the balloon-borne telescope.

Fazio, G. G.↗

Balloon-borne scanning spectrometer system for atmospheric extinction studies in the 350-1100 nm spectral region

A scanning spectrometer system which is capable of being flown in high-altitude balloon studies of the earth's atmosphere is presented. The instrument is small, has a large operative wavelength range of 350-1100 nm, high data density, and real-time data telemetry to ground. A computer software package is used to provide a real-time monitor of balloon gondola and instrument performance, with the software reliability enhanced by proof of correctness techniques and exhibiting the high degree of reliability necessary for the monitoring system.

Thompson, D. A.↗

The direct and scattered solar flux within the stratosphere

Solar ultraviolet flux data obtained within the atmosphere by using Fastie-Ebert double monochromators carried on a balloon-borne gondola and a rocket payload are analyzed. Both the direct and scattered components of the solar ultraviolet flux at wavelengths from 190 to 320 nm are measured at the balloon float altitude of 40 km. The nearly identical spectrometer carried on the rocket flight measures the direct solar flux from 60 to 38 km during a parachute descent. The ozone column content above 40 km and the temperature profile and ozone density below 40 km are deduced using the scattered and direct solar flux components. It is shown that the Nimbus 7 solar flux data are consistent with the present data and with the ozone absorption cross sections of Inn and Tanake (1959). The calculated and measured values of the scattered solar flux are found to agree fairly closely.

Herman, J. R.↗

Forward scattering and backscattering of solar radiation by the stratospheric limb after Mount St. Helens eruption

Stratospheric limb radiance profiles versus altitude of closest approach of the line of sight to the Earth's surface have been measured before and after the Mount St. Helens eruptions by means of photographs taken from a Sun-oriented balloon gondola floating above 35 km altitude over France. Preliminary data were reported for flights in October 1979 and in May and June 1980. The radiance integrated along the line of sight as in-situ radiance (R) can be derived taking into account absorption by ozone and air. The onion peeling inversion method was used to derive the vertical radiance (R) profiles respectively. The values of R were determined in the solar azimuth. The solar elevation angles are chosen larger for the backscattering observation than for the forward scattering observation to deal with as similar illumination conditions as possible despite the Earth's sphericity.

Ackerman, M.↗

GSFC optical ozonesonde results during the Gap, France, intercomparisons, June 1981

O3 soundings made with balloon-borne optical sensors during the French Intercomparison Ozone Campaign in June, 1981, are reported. The GSFC four-channel UV-filter-photometer ozonesonde designed for the Super Loki rocket was attached to the gondola roof for redundant O3-density measurements at altitudes of 22-32 km, using the 300 and 303-nm filters. Sensor calibration, data processing, input constants, and vertical O3-distribution calculations are discussed. The density profiles for three legs of the flight, calculated using Bass or Vigroux cross sections, agreed within a standard error of 1.4 percent for each channel, but showed a consistent 4-5 percent (significant) difference between channels. Total average O3-column amounts determined by combining the GSFC data with ECC measurements for altitudes below 21 km were in good agreement with bias-corrected TOMS data from Nimbus-VII and with ground-based data from the Observatoire de Haute-Provence at Mt. Chiran, when the latter were computed using the pre-campaign calibration. A 9-percent discrepancy arose when the Chiran data were corrected for a post-campaign recalibration of the Dobson spectrophotometer.

Krueger, A. J.↗

Balloon-borne diode-laser absorption spectrometer for measurements of stratospheric trace species

An instrument has been designed for the measurement of stratospheric trace species which utilizes tunable infrared diode lasers as sources for sensitive in situ absorption spectroscopy in selected wavelength regions. This instrument, the Balloon-Borne Laser In Situ Sensor (BLISS), is a high-resolution absorption spectrometer designed to provide measurements of the concentrations of stratospheric species and their diurnal variations. The instrument employs second-harmonic detection of the absorption of tunable diode laser (TDL) radiation (3-30 microns) in a 1 km path length defined by a retroreflector lowered 0.5 km below the BLISS gondola. Retroreflector tracking under microprocessor control is obtained using a He-Ne laser and coaligned TV camera with CID imaging. Simultaneous measurements of molecular species in the 20-40 km altitude range will be performed using four TDLs, with the predicted minimum-detectable mixing ratio at 30 km being typically less than or equal to 0.1 ppbv.

Menzies, R. T.↗

A mercuric detector system for X-ray astronomy. 2. Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate (Bi4Ge3O12) scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, Texas. The second flight of this instrument established a differential background counting rate of 4.2 O.7 x 10-5 counts/sec cm keV over the energy range of 40 to 80 keV. This measurement was within 50% of the predicted value. The measured rate is approx 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range. The prediction was based on a Monte Carlo simulation of the detector assembly in the radiation environment at float altitude.

Vallerga, J.↗

High resolution X- and gamma-ray spectroscopy of solar flares

A balloon-borne X- and gamma-ray instrument was developed, fabricated, and flown. This instrument has the highest energy resolution of any instrument flown to date for measurements of solar and cosmic X-ray and gamma-ray emission in the 13 to 600 keV energy range. The purpose of the solar measurements was to study electron acceleration and solar flare energy release processes. The cosmic observations were to search for cyclotron line features from neutron stars and for low energy gamma-ray lines from nucleosynthesis. The instrument consists of four 4 cm diameter, 1.3 cm thick, planar intrinsic germanium detectors cooled by liquid nitrogen and surrounded by CsI and NaI anti-coincidence scintillation crystals. A graded z collimator limited the field of view to 3 deg x 6 deg and a gondola pointing system provided 0.3 deg pointing accuracy. A total of four flights were made with this instrument. Additional funding was obtained from NSF for the last three flights, which had primarily solar objectives. A detailed instrument description is given. The main scientific results and the data analysis are discussed. Current work and indications for future work are summarized. A bibliography of publications resulting from this work is given.

Lin, R. P.↗

In situ measurement of stratospheric nitric oxide using a balloon-borne tunable diode laser spectrometer

The stratospheric mixing ratio of nitric oxide at an altitude of 36 km has been measured using a balloon-borne tunable diode laser (TDL) instrument operating in the 5.2-micron wavelength region. Currently the instrument operates with two TDLs, and the capability exists to measure four stratospheric species simultaneously: NO, NO2, O3, and H2O. During the NO measurements reported here, the second TDL operating near 6.2 microns was used to monitor water vapor concentration in the vicinity of the gondola by observing the 1889.57 per cm line absorption in the reference channel path length (1 m).

Webster, C. R.↗