Search NASASearch

SEARCH · Search NASA

Results for “GUIDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comparing cross-platform performance via node-to-node scaling studies

Due to the increasing diversity of high-performance computing architectures, researchers and practitioners are increasingly interested in comparing a code’s performance and scalability across different platforms. However, there is a lack of available guidance on how to actually set up and analyze such cross-platform studies. In this paper, we contend that the natural base unit of computing for such studies is a single compute node on each platform and offer guidance in setting up, running, and analyzing node-to-node scaling studies. In conclusion, we propose templates for presenting scaling results of these studies and provide several case studies highlighting the benefits of this approach.

cross-platform studies

Estimating the Contributions to Human Error Probability from the Convolution of the Distribution of Time Available and Time Required

As part of their duties, Human Reliability Analysis must often evaluate if crews in nuclear power plants (NPPs) can complete tasks associated with a human-failure event within time limits. For example, the time required in NPP scenarios is determined by systematic and structured walkthroughs, feasibility studies, recorded times from training exercises, and interviews with experienced operators and experts. Typically, a point estimate is derived for the estimate (mean, maximum, or 95th percentile of time required). Using point-estimate values can mask the risk associated with variability among crews, plant conditions and set-up, environmental conditions, and other impact factors under which these actions are executed. While point estimates for time required and time available have served the industry well, without considering the uncertainty they could lead to biased understanding about the risk. The Integrated Human Event Analysis System - General Methodology (IDHEAS-G) model (developed by the US Nuclear Regulatory Commission, NRC) for human error probability calculates human error probability by summing two probabilities: insufficient time and cognitive error. As such, the model takes a more holistic approach by considering the full distributions for time required and time available to calculate the human error probability because the time available to complete the task is insufficient. In this study, we expand on the work of the NRC and discuss methods for estimating these time considerations. For example, for the time required, the impact of Performance Influencing Factors (PIFs) on the distribution was divided into impacts that are aleatory in nature, such as crew-to-crew variability, and those that are epistemic (i.e., the PIFs). Starting with the factors that introduce aleatory uncertainty, a first-order distribution was developed from a large set of time required (i.e., NPP task completion times) data for the range of operator actions that occur in the NPP control room under simulated accident conditions. The first-order distribution can then be adjusted to account for epistemic uncertainty using research associated with the impact of applicable PIFs on the time required. We also develop guidance for analysts to address the probability distributions for the time available. The guidance we developed on how to estimate time required and time available distributions is based on the identification of pertinent research and data, data analyses, and expert knowledge elicitation.

human error probability, human performance, time e

Antigua and Barbuda Distributed Energy Resources Deployment Guidelines

This document is designed to provide comprehensive considerations, best practices and guidance for deployment of Distributed Energy Resources (DERs) in Antigua and Barbuda. The document provides lists of various technology selection guidance including technical specifications, requirements and applicable key standards and code associated with key DERs and balance of plant equipment. The document also presents the key microgrid design considerations to integrate the DERs to achieve the economic, decarbonization and resiliency goals. Taking into account sensitive grid for such islands, for grid readiness and screening the potential DER interconnection, general approach is highlighted along with the potential technical interconnection requirements. Furthermore, this document shows the key stakeholders involved in such DER integration and/or microgrid project and how key responsible project team can be qualified. Finally, this document refers to key information about warranties and consumer rights and maintenance of the systems.

24 POWER TRANSMISSION AND DISTRIBUTION

A guide on modeling electrostatics of semiconductor detectors in COMSOL Multiphysics ® for DRiFT

Adding a new semiconductor detector into the detector response function toolkit (DRiFT) requires a model of the electric potential and the electric field. To get an accurate electrostatics model, the geometry of the detector should be modeled as closely to the real geometry as feasible, including the semiconductor materials, doping layers and concentrations, and contacts. Since the electric field and potential are used to calculate the induced signal, the results of the detector response functions are largely influenced by the electrostatics models. Initial electrostatics models were completed using Silvaco, however, this document provides guidance on using COMSOL Mulitphysics ® (COMSOL) to model the detectors to give users additional flexibility. Guidance on using COMSOL and its user interface are mostly left out of this document, but best practices for geometry, modeling methods, and data format/exporting are included to help users generate models that are compatible with DRiFT, prevents bugs, issues, and inaccuracies during charge collection calculations. The following summary provides an overview of the document.

42 ENGINEERING

Best Practices in Integrated Resource Planning: A guide for planners developing the electricity resource mix of the future

Most states today require regulated electric utilities to file an IRP every 1 to 5 years, and some utilities voluntarily prepare these plans. Planning needs have changed in recent years due to emerging load growth, plant retirements, rising costs, and more extreme weather events – among other factors. In response, Synapse Energy Economics and Lawrence Berkeley National Laboratory produced a joint report, Best Practices in Integrated Resource Planning: A guide for planners developing the electricity resource mix of the future. The guide offers best planning practices for electricity systems undergoing a major transition, but also contains a wealth of practical guidance to develop technically sophisticated, clearer, more effective, and state-of-the-art electric utility resource plans. The guide is for resource planning professionals and stakeholders involved in resource planning processes. This diverse group includes utility personnel tasked with conducting resource planning and making investment decisions, state regulatory commissions that develop planning guidance and oversee the resource planning process, and stakeholders that represent a wide range of interests—utility consumer advocates, environmental groups, industrial customers, local governments, independent power producers, and many other

29 ENERGY PLANNING, POLICY, AND ECONOMY

Idaho National Laboratory Integrated Multisite SSHAC Level 3: Probabilistic Volcanic Hazards Assessment

The Idaho National Laboratory (INL) resides on the eastern Snake River Plain (ESRP), part of the Snake River Plain (SRP) with a complex origin and geologic history of volcanism. Much of the Quaternary (last 2.58 million years) volcanism within 400 km of INL is genetically associated with a major thermal anomaly referred to as the Yellowstone hotspot, which is currently located more than 180 km northeast of INL. Near INL, local volcanic sources include silicic domes near its southern border, and numerous dike-fed basaltic vents of the ESRP, some of which are near or within the INL boundaries. Quantitative probabilistic assessments of screened-in volcanic hazardous phenomena for nine different facility complexes at the INL are presented for a Senior Seismic Hazard Analysis Committee (SSHAC) Level 3 (SL3) study. The comprehensive, integrated multisite SSHAC study consists of a single regional Probabilistic Volcanic Hazards Assessment (PVHA) that pertains to all nine INL facility complexes, with site-specific information developed at each respective area of interest (AOI), referred to as the "INL facility AOI" (Figure ES-1). Hazard products are generated for specified INL facility AOIs for use by multiple stakeholders from different agencies in risk-informed decision-making regarding site selection, operations, and design of nuclear facilities at INL, consistent with U.S. Department of Energy (DOE) and U.S. Nuclear Regulatory Commission (NRC) regulatory guidance. The study also serves as the basis for future periodic safety assessments required for existing DOE facilities, such as 10-year evaluations of natural-phenomena hazards. Elements of the INL PVHA including initial characterization, screening, quantitative assessments of eruption and hazard potential, and consideration of facility needs are conducted using the three phases of the SSHAC process: evaluation, integration, and documentation. As per regulatory guidance, the SSHAC framework provided the necessary processes and procedures for the PVHA Technical Integration (TI) team, at three workshops, five formal working meetings and many TI team remote meetings, to conduct initial characterization, screen the volcanic hazards, create PVHA model inputs, exercise those models in the PVHA, consider facility-specific volcanic hazard needs, and perform final hazard calculations. The Participatory Peer Review Panel (PPRP) provided independent oversight and performed process and technical reviews of the PVHA throughout its duration. The study included an extensive New Data Collection and Analyses (NDCA) program developed by the PVHA TI team to reduce uncertainties in hazard-significant elements in the PVHA model. NDCA activities generated 20 reports providing important contributory datasets and results to the project database for characterizing the ESRP. For example, a report compiling the dimensions of ESRP shield volcanoes and lava fields was used to construct volcanic footprints (areas of impact), was compared with data from INL subsurface cores, and was used to validate the results of lava-flow inundation modeling on the contemporary terrain. Another example is the acquisition of aeromagnetic data over INL and its surrounding area, with maps of buried magmatic features (e.g., subsurface volcanoes and swarms of feeder dikes) that informed the PVHA conceptual model of volcanism. The SSHAC evaluation process was used to conduct all elements of the PVHA including initial characterization and screening. Existing data and NDCA activities provided the foundation to develop the tectonomagmatic conceptual model of volcanism for the region of geographical interest in the SRP and Yellowstone hotspot volcanic system, and for considering volcanoes in the western US. Considering Quaternary volcanic sources active during this period, the screening approach identified and evaluated magma compositions, types of eruptive and intrusive phenomena, types of hazardous phenomena, and proximity of sources to INL. The PVHA TI team evaluated 18 types of magmatic sources in terms of 20 potentially hazardous phenomena, resulting in 360 screening decisions. The screening process resulted in 140 screened-in hazardous volcanic phenomena for Quaternary volcanic sources 1) proximal to INL facility complexes in the ESRP (64 basaltic and 54 silicic), 2) regional sources associated with the Yellowstone caldera system and Blackfoot Reservoir volcanic field (7), and 3) more distal sources from thirteen Cascade volcanoes and two volcanoes at Long Valley caldera (CA).

58 GEOSCIENCES

Building Performance Software: Portfolio-Level Capabilities and Applications

Navigating the broad and rapidly evolving market landscape of software solutions is complex whether you are a sustainability leader, building owner, energy manager, or building engineer with energy and greenhouse gas (GHG) emissions reduction goals for a portfolio of buildings. The Department of Energy’s Better Buildings partners have noted this complexity and the associated lack of publicly available information. In response, this report reviews the ecosystem of environmental, social, and governance (ESG), energy management information systems (EMIS), and decarbonization software with the goal of orienting prospective users to current offerings. Organizations can utilize this guidance to determine the specific capabilities needed to support decarbonization efforts and procure appropriate software to streamline the GHG emissions reduction process. In this paper, we refer to “decarbonization software” as the category of software that meets an organization’s needs for decarbonization planning, implementation, and tracking. This software may have a heritage in ESG or EMIS, or it may be an entirely new product. This report offers a snapshot of today’s rapidly evolving decarbonization software capabilities, along with guidance for procuring and utilizing it that will remain relevant despite any future software changes. Exploratory research was conducted on over 100 software providers, and interviews were held with 28 of them. Note that inclusion in this report does not indicate an endorsement, nor does a product’s absence from this report indicate a lack of suitability

97 MATHEMATICS AND COMPUTING

Review of Reactor Facilities without Main Control Rooms

Small, advanced reactors may require few, if any, safety-related human actions (HAs) and fewer HAs to monitor and control the plant. In comparison to large light water reactors, these are significant changes that have implications for many aspects of an applicant's human factors engineering (HFE), including control room design, plant staffing, and the management of safety functions. To support the Nuclear Regulatory Commission's (NRC) ability to evaluate these changes, information needs to be developed addressing the characteristics and potential issues. The objectives of our research were to (1) identify when a traditional main control room (MCR) may not be necessary, (2) identify workplace design alternatives to traditional MCRs, and (3) develop guidance for reviewing an applicant's workplace designs with and without a MCR. We determined that the safety question isn't so much justifying why a design has no MCR, but rather verifying that important human actions can be accurately and reliably performed under a range of challenging conditions using the HSIs provided regardless of their location. We developed guidance to review alternatives to MCRs based on HFE analyses for determining workplace location and design.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Quality Guidelines for Energy System Studies: Capital Cost Scaling Methodology: Revision 4b Report

The National Energy Technology Laboratory (NETL) regularly updates legacy analysis with new studies and cases as the Department of Energy objectives change, technology performance improves, costs are reduced, regulations change, market drivers are established, fuel prices fluctuate, and any number of other relevant factors vary in the market. As legacy studies are updated by NETL, the underlying performance and cost of the cases presented changes, and as such, the methods for interpreting and scaling the cost estimates change. Therefore, it is important that NETL maintain public guidance documents associated with different sets of cost estimates that delineate how a specific set, based on report vintage and/or year published, should be scaled. This Quality Guidelines for Energy System Studies report, providing guidance on capital cost scaling, should generally be applied to NETL case costs included in the report “Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity Revision 4b,” (NETL, 2025) or any cases derived from the cases presented in the referenced report.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Enhancing Modeling and Simulation for Effective Protection Strategies

This report was created by Sandia National Laboratories (SNL) to document the principles and methodology of performance data collection and integration with modeling and simulation tools to better facilitate the performance evaluation of physical protection systems (PPS). Results and conclusions from the use of modeling and simulation tools are only as good as the data employed by the tools when conducting analysis. Acquiring the performance testing data necessary to ensure effective evaluation can be a complex and sometimes daunting process. It is the desire of the organization to provide guidance that eases the burdens associated with pursuit of these objectives. This document draws heavily upon longstanding principles of systems engineering that have been developed and employed by SNL in the discipline of security since the 1970s. The scope of this document is constrained to the testing of system components and integration of data that is applicable within the context of PPS performance analysis using two tools that have been developed by SNL, PathTrace© and Scribe3D©. For guidance related to testing and evaluation more broadly, the manuals and reports referenced by this document can be consulted.

42 ENGINEERING

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY

Life-Cycle Cost Analysis Framework for Water Efficiency Measures

Life-Cycle Cost Analysis Framework for Water Efficiency Measures: Guidance Designed for Federal Agencies (hereafter referred to as “this report”) provides a technical framework for federal agencies to conduct a life-cycle cost analysis (LCCA) for water efficiency projects in accordance with 42 U.S.C. § 8253. This report leverages insights from the 2023 report, PNNL-34006, Water and Wastewater Annual Price Escalation Rates for Selected Cities Across the United States: 2023 Edition (Unger et al. 2023). The primary objective of this report is to provide a framework to assist federal agencies with evaluating the full economic impact of water efficiency projects by assessing both initial investments and long-term operational benefits. An LCCA can provide a comprehensive view of all costs associated with a water efficiency project, including initial investment, ongoing operations and maintenance (O&M), and eventual disposal or replacement, ensuring the most cost-effective solution is selected. The LCCA methodology outlined in this report enables users to compare base case scenarios with potential alternatives using a standardized present value approach. It incorporates key cost components such as energy, water and wastewater, installation, O&M, and equipment replacement. Additionally, the framework introduces relevant evaluation metrics, such as the net savings and the savings-to-investment ratio, to ensure that water efficiency measures are economically justified over the lifespan of the project. To support practical application, this report also describes various water efficiency strategies that may be analyzed using an LCCA, including plumbing retrofits, irrigation upgrades, alternative water use, and cooling system improvements. By applying this framework, federal agencies can ensure compliance with regulatory mandates while maximizing the return on investment and contributing to resilient water management practices. The information provided in this report is aligned with the Federal Energy Management Program (FEMP) life-cycle cost (LCC) methodology, as conveyed in National Institute of Standards and Technology (NIST) Handbook 135 (Kneifel and Webb 2022). This report is intended to provide relatively high-level guidance, acting as a complement to, rather than a substitute for, that resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Blueprint: Coordinated Vulnerability Disclosure (CVD) Adoption for Information Sharing and Analysis Center (ISAC)-Like Groups

The electric vehicle supply equipment (EVSE) industry is an incredibly diverse set of participants (EVSE manufacturers, charge network operators (CNOs), original equipment manufacturers (OEMs), etc.), and with the potential for an Information Sharing and Analysis Centers (ISAC) or ISAC-like group, it requires a series of guidance for doing a multiparty coordinated vulnerability disclosure (CVD) such that a group like this could be successful. This blueprint provides a template and guidance to stakeholders in the EVSE industry for conducting a multiparty CVD. It also formalizes what multiparty CVD could look like in an ISAC-like group with multiple entities as well as vulnerability coordinators by specifically calling out who in the ISAC-like group may be involved, and which industry members it may apply to. This blueprint leverages tools such as Vultron, VINCE, etc. along with open resources such as the Software Engineering Institutes guide for coordinated vulnerability disclosure, for the stakeholder in the EVSE industry to start up a CVD program of their own.

97 MATHEMATICS AND COMPUTING

The NREL Sensor Laboratory Detection of Hydrogen Emissions

The development of a functional hydrogen detection system is a multifaceted process that integrates hardware, deployments strategies, and analytics which can be supported by the NREL Sensor Laboratory: 1. Support of the design, validation and optimization of sensing prototypes; 2. Guide optimized sensing element development, including control electronics; 3. Laboratory testing to validate/optimize metrological performance (measurement range, detection limit, etc.); 4. Provide test sites for field deployments representative of real-world scenarios with controlled hydrogen releases; 5. Develop sensor placement and operation guidance; 6. Provide guidance on electronics to accommodate facility integration; 7. Electrical safety designs to allow for operation within restricted zones; 8. Integration into facility monitoring and control systems; 9. Guide incorporation of cyber security elements to protect facilities from malicious attacks; 10. Modeling and application of advanced analytics to detect and quantify emissions; 11. Higher Order dispersion models to guide sensor placement for reliable detection; 12. Advanced analytics for improved metrological performances, and to inform inverse modeling; 13. Market support and commercialization (national and international markets); 14. Commercial deployments in H2@SCALE markets (e.g., HUBs and other large-scale hydrogen markets); and 15. Leverage off international collaborations/partnerships (e.g., NREL is on the advisory board for the European initiative "pre-Normative Research on Hydrogen Releases Assessment"-NHyRA).

08 HYDROGEN

Reassessing Double-Ended Guillotine Break Requirements: Evidence-Based Analysis of Regulatory Assumptions After Five Decades of Nuclear Operation

After five decades of nuclear power operation encompassing more than 20,000 reactor-years across 35 countries and 647 reactors, zero double-ended guillotine breaks (DEGBs) have been documented in commercial reactor coolant systems—despite DEGB being the fundamental design-basis assumption driving Emergency Core Cooling System (ECCS) sizing, structural protection requirements, and containment design specifications. This report examines the basis for DEGB requirements in nuclear power plant design. The DEGB postulate assumes the instantaneous, complete circumferential severance of the largest diameter pipes in reactor coolant systems, driving major design requirements under 10 Code of Federal Regulations 50.46, General Design Criterion 4 and containment design specifications. The United States (4,880 reactor-years) and France (2,505 reactor-years) contribute the largest operational datasets. Probabilistic assessments estimate direct DEGB occurrence probabilities with extremely low event frequencies, far below the 10-5/reactor-year thresholds typically used to define non-credible events in nuclear-safety analyses; i.e., events with probability this low fall into beyond-design-basis events. Current material-science knowledge demonstrates that the ductile steel materials used in nuclear piping systems exhibit stable crack-growth behavior fundamentally incompatible with instantaneous severance. International regulatory experience, particularly Germany’s comprehensive break-preclusion implementation, and successful leak-before-break (LBB) applications in almost all of U.S. pressurized water reactor units validate that alternatives can maintain safety performance while reducing economic burden. Current DEGB protection systems impose estimated lifetime costs of hundreds of millions of dollars per unit, over the life of a plant across the nuclear industry (including ongoing costs), representing substantial resource allocation toward scenarios with extremely low probability. Although this report acknowledges uncertainties regarding long-term aging effects, potential synergistic degradation mechanisms, and site-specific seismic considerations that warrant continued evaluation as regulatory policy evolves, there remains no documented evidence that a DEGB has occurred as a consequence of the conditions or mechanisms described in this report. This report acknowledges the Nuclear Regulatory Commission’s (NRC’s) recent efforts—outlined in the draft Interim Staff Guidance (ISG) NRC-DSS-ISG-2025-XX (“Treatment of Certain Loss-of-Coolant Accident Locations as Beyond-Design-Basis Accidents Draft Interim Staff Guidance”)—to reduce overly conservative requirements for large-break loss of coolant accidents through technical justifications and exemptions. However, extensive operating experience and validated methodologies—such as LBB and in-service inspection programs—demonstrate that the probability of a DEGB in reactor coolant-loop piping is extremely low, even under seismic conditions. The authors and reviewers of this report recommend that DEGB be removed as a design-basis event through formal rulemaking, rather than case-by-case exemptions, to better reflect credible failure modes, align with current data, and align with modern, risk-informed safety analysis.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Best Practices for Resilience Hub Development and Management

The Carbon League and its community partners in East St. Louis, Illinois, have identified five facilities to serve as resilience hubs. These hubs are intended to support the local community through a range of services and resources during blue-sky (everyday), gray-sky (pre-event), and black-sky (emergency) conditions. Transforming these facilities into fully functional resilience hubs requires a broad operational improvement and programmatic planning roadmap. This memo outlines best practices to guide the development of these resilience hubs in East St. Louis, including recommendations for infrastructure services; safety and physical protection; community services; operational protocols; and a phased implementation strategy aligned with realistic funding and capacity constraints. Infrastructure recommendations include strengthening electric power, communications, water, sanitation, and transportation/logistics capabilities, all of which are essential for hubs that may serve as cooling and warming centers, distribution points, and information hubs during emergencies. Safety recommendations focus on accessibility, emergency action planning, indoor air quality, and secure storage of critical equipment. A phased roadmap provides guidance from immediate, low-cost readiness actions to long-term optimization and community integration. Performance metrics and maintenance protocols ensure continuous improvement and operational readiness. This guidance draws on best practices that can be used to support the development of resilient, community-centered hubs capable of enhancing public safety, health, and well-being during everyday operations and emergencies alike.

99 GENERAL AND MISCELLANEOUS

Integrating Carbon Capture, Utilization, & Sequestration into Chemical Pulp Mills

The U.S. pulp and paper industry presents a unique and largely untapped opportunity for large- scale carbon dioxide removal (CDR). Unlike most industrial sectors, pulp mills rely heavily on biomass, meaning that much of their carbon emissions originate from atmospheric CO₂ that was recently captured by plants. If this biogenic CO₂ can be captured and permanently stored, pulp mills can be transformed from carbon emitters into net carbon removal facilities. This project was motivated by that opportunity and aimed to develop and evaluate integrated, low-cost strategies for capturing, utilizing, and sequestering CO₂ within existing chemical pulping operations. The scope of this work focused on four complementary innovations designed to integrate seamlessly into kraft pulp mill infrastructure: (1) in situ CO₂ capture within the recovery cycle, (2) oxy-fuel retrofitting of the rotary lime kiln to produce a high-purity CO₂ stream, (3) ex situ CO₂ capture and mineralization using pulp mill residues (dregs, grits, and lime mud), and (4) beneficial reuse of these residues as mineral carbonate fertilizers. The project combined process modeling, laboratory experimentation, life cycle assessment (LCA), and field trials to evaluate the technical feasibility, economic viability, and environmental impact of these approaches. The results demonstrate that pulp mills can serve as effective platforms for carbon removal when equipped with integrated carbon capture systems. Process modeling showed that combining sodium spiking with oxy-fuel calcination significantly enhances CO₂ capture efficiency while reducing costs by up to 31% compared to conventional configurations. Experimental work further revealed that calcination behavior in high-CO₂ environments differs substantially from traditional systems, leading to the development of a new kinetic model that predicts reaction rates under these conditions. This model provides essential design guidance for next-generation decarbonized lime kilns. In parallel, the project demonstrated that alkaline mineral residues generated during pulping operations can be repurposed as a sustainable alternative to agricultural lime. Across a wide range of soils in the southeastern United States, these materials performed equivalently to commercial lime in adjusting soil pH while offering lower greenhouse gas emissions and reduced cost. Field and greenhouse studies confirmed that crop and tree growth responses were comparable, supporting their viability as a drop-in replacement. This co-product pathway provides a practical utilization strategy that offsets costs and improves overall system economics. A major contribution of this project is the first comprehensive life cycle assessment of carbon removal in pulp and paper systems across multiple system boundaries. Results show that retrofitted mills can achieve carbon removal efficiencies ranging from 12% to 92%, depending on how the system is defined. This finding highlights a critical issue in carbon accounting: reported performance is highly sensitive to methodological choices. By explicitly quantifying these differences, this work provides valuable guidance for policymakers, carbon registries, and project developers working to standardize carbon removal metrics. From a commercialization perspective, the technologies investigated in this project are well- aligned with existing industrial infrastructure, minimizing the need for entirely new facilities. 3 DE-EE0009413 Industry engagement throughout the project—including collaboration with pulp and paper companies, equipment manufacturers, and carbon removal developers—has accelerated the transition from research to deployment. Notably, a commercial developer is actively pursuing carbon capture projects at pulp mills in the southeastern United States and has cited this research as a contributing foundation. The emergence of voluntary carbon markets and long-term offtake agreements further strengthens the business case for implementation. The broader public benefits of this work are significant. By enabling large-scale carbon removal using existing industrial systems, this approach offers a near-term pathway to reduce atmospheric CO₂ concentrations while supporting domestic manufacturing and rural economies. The reuse of industrial residues as fertilizers reduces reliance on mined materials, lowers costs for farmers, and decreases environmental impacts associated with conventional lime production. In addition, the project has supported workforce development by training graduate students and researchers in carbon capture technologies, helping to build capacity in a critical area of national interest. In conclusion, this project demonstrates that integrated carbon capture, utilization, and sequestration in pulp mills is both technically feasible and economically promising. By combining process innovation, experimental validation, and systems-level analysis, the work advances the understanding of how biomass-based industries can contribute to climate mitigation. The findings provide a strong foundation for commercial deployment and offer a scalable solution for transforming a major U.S. industry into a source of durable carbon removal.

09 BIOMASS FUELS

Updating the Building Science Advisor (BSA): A Tool to Assist in the Design of Durable Building Envelopes

Predicting the moisture durability of building envelope components remains challenging due to multiple influencing factors, including material selection, assembly positioning, local climate conditions, air tightness, interior environment, and construction quality. Building codes increasingly emphasize energy efficiency through enhanced insulation and tighter envelopes but offer limited guidance on moisture durability considerations. Consequently, builders face uncertainty, particularly as new materials and assemblies enter the market.The Building Science Advisor (BSA) is a free, web-based expert system developed to address these challenges by providing actionable insights into the moisture durability and energy efficiency of both new and retrofit wall designs. Recently updated, we are now providing version 3.0 of the tool. BSA features significant user interface improvements, enhancing navigation and user interaction through a refreshed, intuitive design. Additionally, the tool incorporates a newly developed database containing pre-simulated wall assembly cases, significantly reducing response times and improving the accuracy of moisture durability assessments. Furthermore, the updated BSA includes moisture content as a performance criterion, providing users with a more comprehensive understanding of moisture-related durability risks. These enhancements enable rapid, reliable assessments tailored to specific climate zones and local building practices. BSA continues to offer targeted guidance on wall retrofit scenarios and delivers access to an expanded library of location-specific building science resources.This paper describes these key updates, highlighting the enhanced features, expanded capabilities, and overall improvements to user experience and educational content. The paper includes a demonstration that illustrates how the revised BSA effectively supports practitioners in designing durable, energy-efficient building envelope assemblies.

Salonvaara, Mikael [ORNL] (ORCID:0000000318991554)