Search NASA⌕ Search

SEARCH · Search NASA

Results for “Group Synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

THE PRIMEVAL POPULATIONS OF THE ULTRA-FAINT DWARF GALAXIES

We present new constraints on the star formation histories of the ultra-faint dwarf (UFD) galaxies, using deep photometry obtained with the Hubble Space Telescope (HST). A galaxy class recently discovered in the Sloan Digital Sky Survey, the UFDs appear to be an extension of the classical dwarf spheroidals to low luminosities, offering a new front in efforts to understand the missing satellite problem. They are the least luminous, most dark-matter-dominated, and least chemically evolved galaxies known. Our HST survey of six UFDs seeks to determine if these galaxies are true fossils from the early universe. We present here the preliminary analysis of three UFD galaxies: Hercules, Leo IV, and Ursa Major I. Classical dwarf spheroidals of the Local Group exhibit extended star formation histories, but these three Milky Way satellites are at least as old as the ancient globular cluster M92, with no evidence for intermediate-age populations. Their ages also appear to be synchronized to within {approx}1 Gyr of each other, as might be expected if their star formation was truncated by a global event, such as reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Transient Stability Enhancement via a Scalable RL Method with VSG Parameter Tuning

This paper presents a reinforcement learning (RL)-driven strategy to improve the transient stability of power systems via tuning parameters of multiple virtual synchronous generators (VSGs). We proposed a scalable method to support RL training convergence probability and speed, even when a large number of contingencies are considered. The proposed scalable RL framework first decomposes the large number of contingencies into multiple groups and then conducts parallel training for each group, decreasing the state space and complexity of each training. Additionally, we propose a contingency grouping algorithm to streamline the RL action space and facilitate the training. The proposed method is validated across various standard test systems.

Huang, Xiaoge↗

A Fast and Accurate Transient Stability Assessment Method Based on Deep Learning: WECC Case Study

Transient stability is one of the critical aspects of power system stability assessment. The increasing integration of inverter-based resources and the retirement of conventional synchronous generators result in the decreasing system inertia and growing complexity of system operating conditions. Using a few selected typical operating conditions cannot guarantee system transient stability in all operating conditions, and the time-domain simulation of all operating conditions requires tremendous time and is often infeasible. This paper proposes a more efficient transient stability assessment method based on deep learning. The binary search method is used to determine the critical clearing time (CCT) in creating training databased by time-domain simulation. This method is fast and accurate with 1 ms resolution. The buses whose CCTs are lower than 200 ms are considered critical buses. Buses close to each other are grouped based on their mutual admittance matrix to reduce the search space of the critical buses. This paper also proposes the generator feature normalization based on the physical model. Case study on the reduced 240-bus WECC system model demonstrates that the proposed method can predict CCT accurately and efficiently.

critical clearing time↗

Radiation-Induced Cranial Nerve Palsy: A Cross-Sectional Study of Nasopharyngeal Cancer Patients After Definitive Radiotherapy

Purpose: To address the characteristics and the causative factors of radiation-induced cranial nerve palsy (CNP) in nasopharyngeal carcinoma (NPC) patients with an extensive period of followed-up. Patients and Methods: A total of 317 consecutive and nonselected patients treated with definitive external-beam radiotherapy between November 1962 and February 1995 participated in this study. The median doses to the nasopharynx and upper neck were 71 Gy (range, 55-86 Gy) and 61 Gy (range, 34-72 Gy), respectively. Conventional fractionation was used in 287 patients (90.5%). Forty-five patients (14.2%) received chemotherapy. Results: The median follow-up was 11.4 years (range, 5.1-38.0 years). Ninety-eight patients (30.9%) developed CNP, with a median latent period of 7.6 years (range, 0.3-34 years). Patients had a higher rate of CNP (81 cases, 25.5%) in lower-group cranial nerves compared with upper group (44 cases, 13.9%) ({chi}{sup 2} = 34.444, p < 0.001). Fifty-nine cases experienced CNP in more than one cranial nerve. Twenty-two of 27 cases (68.8%) of intragroup CNP and 11 of 32 cases (40.7%) of intergroup CNP occurred synchronously ({chi}{sup 2} = 4.661, p = 0.031). The cumulative incidences of CNP were 10.4%, 22.4%, 35.5%, and 44.5% at 5, 10, 15, and 20 years, respectively. Multivariate analyses revealed that CNP at diagnosis, chemotherapy, total radiation dose to the nasopharynx, and upper neck fibrosis were independent risk factors for developing radiation-induced CNP. Conclusion: Radiation-induced fibrosis may play an important role in radiation-induced CNP. The incidence of CNP after definitive radiotherapy for NPC remains high after long-term follow-up and is dose and fractionation dependent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developmental programming: Impact of fetal exposure to endocrine-disrupting chemicals on gonadotropin-releasing hormone and estrogen receptor mRNA in sheep hypothalamus

Bisphenol-A (BPA) and methoxychlor (MXC), two endocrine-disrupting chemicals (EDCs) with estrogenic and antiandrogenic effects, disrupt the reproductive system. BPA has profound effects on luteinizing hormone (LH) surge amplitude, and MXC has profound effects on on LH surge timing in sheep. The neural mechanisms involved in the differential disruption of the LH surge by these two EDCs remain to be elucidated. We tested the hypothesis that the differential effects of BPA and MXC on LH surge system involved changes in hypothalamic gonadotropin-releasing hormone (GnRH) and estrogen receptors (ESR), ESR1 and ESR2, mRNA expression. Pregnant sheep were given daily injections of cottonseed oil (controls), MXC, or BPA (5 mg/kg/day) from day 30 to 90 of gestation (term 147 d). Offspring from these animals were euthanized as adults, during the late follicular phase following synchronization of estrus with prostaglandin F{sub 2{alpha}}, just before the expected onset of preovulatory LH surge and changes in mRNA expression of hypothalamic GnRH, ESR1, and ESR2 quantified following in situ hybridization. GnRH mRNA expression was significantly lower in both groups of EDC-treated females compared to controls. ESR1 expression was increased in prenatal BPA- but not MXC-treated females in medial preoptic area relative to controls. In contrast, ESR2 expression was reduced in the medial preoptic area of both EDC-treated groups. Differences in expression of ESR1/ESR2 receptors may contribute to the differential effects of BPA and MXC on the LH surge system. These findings provide support that prenatal exposure to EDCs alters the neural developmental trajectory leading to long-term reproductive consequences in the adult female.

60 APPLIED LIFE SCIENCES↗

Self-consistent integrated modeling of combined hybrid discharge-laser produced plasma devices for extreme ultraviolet metrology

Discharge- and laser-produced plasma (DLPP) devices are being used as light sources for extreme ultraviolet (EUV) generation. A key challenge for both, DPP and LPP, is achieving sufficient brightness to support the throughput requirements of nanometrology tools. To simulate the environment of a hybrid DLPP device and optimize the EUV output, we have developed an integrated HEIGHTS-DLPP computer simulation package. The package integrates simulation of two evolving plasmas (DPP and LPP) and includes modeling of a set of integrated self-consistent processes: external power source and plasma energy balance, plasma resistive magnetohydrodynamics, plasma heat conduction, detailed radiation transport (RT), and laser absorption and refraction. We simulated and optimized DLPP devices using Xe gas as a target material. We synchronized the external circuit parameters, chamber gas parameters, and laser beam temporal and spatial profiles to achieve maximum EUV output. The full 3D Monte Carlo scheme was integrated for detailed RT and EUV output calculations in Xe using more than 3600 spectral groups. The modeling results are in good agreement with Julich Forschungszentrum experimental data. Theoretical models, developed and integrated into the HEIGHTS package, showed wide capabilities and flexibility. In conclusion, the models and package can be used for optimization of the experimental parameters and settings, investigation of DLPP devices with complex design, analyzing the impact of integrated spatial effects and working timeline arrangement on the final EUV output, and EUV source size, shape, and angular distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-223: Investigation of the Accuracy of Two-Dimensional Dose Distributions Measurement From High-Dose-Rate Brachytherapy Ir-192 Source Using Multiple-Diode-Array Detector (MapCheck2)

Purpose: To investigate the dosimetric accuracy of multiple-diode-array detector (Mapcheck2) for high-dose-rate brachytherapy Ir-192 source. The two-dimensional (2D) dose distributions measured with MapCheck2 were validated with EBT2 Gafchromic film measurement and AAPM task-group- 43 (TG-43) modeling. Methods: 2D-dose distributions from Ir-192 source were measured with MapCheck2 and EBT2-films. MapCheck2 response was corrected for effects: directional dependence, diode and phantom heterogeneity. Optical density growth of the film was controlled by synchronized scanning of the film exposed to Ir-192 and calibration films exposed to 6 MV linac beams. Similarly, MapCheck2 response was calibrated to dose using 6 MV beams. An empirical model was developed for the dose distributions measured with Mapcheck2 that considered directional, diode and phantom heterogeneity corrections. The dose deposited in solid-state-detectors was modeled using a cavity theory model for the diode. This model was then validated with measurements using EBT2-films and calculations with TG-43. Results: The response of MapCheck2 has been corrected for different effects including: (a) directional dependence of 0–20% over angular range 0o–90o, (b) phantom heterogeneity (3%) and (c) diode heterogeneity (9%). The corrected dose distributions measured with MapCheck2 agreed well with the measured dose distributions from EBT2-film and with calculations using TG-43 within 5% over a wide range of dose levels and rates. The advantages of MapCheck2 include less noisy, linear and stable response compared with film. The response of MapCheck2 exposed to 192Ir-source showed no energy dependence similar to its response to MV energy beam. Detection spatial-resolution of individual diodes was 0.8×0.8 mm2, however, 2DMapCheck2 resolution is limited by distance between diodes (7.07 mm). Conclusion: The dose distribution measured with MapCheck2 agreed well within 5% with that measured using EBT2-films; and calculations with TG- 43. Considering correction of artifacts, MapCheck2 provides a compact, practical and accurate dosimetric tool for measurement of 2D-dose distributions for brachytherapy Ir-192.

60 APPLIED LIFE SCIENCES↗

Particle Beam Acceleration Using 3 Petawatt Laser Pulses

The Zettawatt-Equivalent Ultrashort pulse laser System (ZEUS) is presently operational at the Gerard Mourou Center for Ultrafast Optical Science (CUOS) at the University of Michigan. ZEUS is a significant upgrade of the previous high power laser systems at CUOS and consists of two beamlines thatoperate in perfect synchronization. The 500 TW beamline became operational in 2023, 2 PW operation started in 2025 and full 3 PW power levels will be available in 2026. It is presently the highest power laser system in the US. In this grant the high field science group at CUOS has leveraged this unique high power laser facility to investigate laser wake field acceleration (LWFA) in ultra-high power laser plasma interactions and have shown how this can scale for future electron–positron colliders at high energy. The dual beam experimental configuration enables flexibility for many frontier experiments in laser-driven acceleration research, in particular, enabling extended channelling/acceleration experiments, positron generation/acceleration experiments and proof-of-principle transverse pumping “dephasingless” electron acceleration experiment and theory. LWFA may be able to miniaturize particle accelerators for high energy physics and also enable new sources of ultrafast, extreme brightness and precise x-rays for a wide variety of applications. In laser wake field acceleration, an electron bunch “surfs” on the electron plasma wave (the “wake field”) generated by the ponderomotive force of an intense laser. The plasma wave has a strong longitudinal electric field that stays in phase with the relativistic driver. A relativistic charged particle may, therefore, remain in phase with the accelerating field over long distances and gain ultra-relativistic energies. The accelerating electric field strength that the plasma wave can support can be many orders of magnitude higher than that of conventional accelerators, which makes laser wakefield acceleration an exciting prospect as an advanced accelerator concept. In this research project we have investigated the scaling of this mechanism to laser powers of 2 PW and have measured the x-ray emission and radio frequency emission resulting from the acceleration process. We have also performed theoretical investigation of mechanisms to scale laser driven accelerators to much higher energy using dephasingless acceleration processes.

43 PARTICLE ACCELERATORS↗

Divergence Reduction in Monte Carlo Neutron Transport with On-GPU Asynchronous Scheduling

While Monte Carlo Neutron Transport (MCNT) is near-embarrasingly parallel, the effectively unpredictable lifetime of neutrons can lead to divergence when MCNT is evaluated on GPUs. Divergence is the phenomenon of adjacent threads in a warp executing different control flow paths; on GPUS, it reduces performance because each work group may only execute one path at a time. The process of Thread Data Remapping (TDR) resolves these discrepancies by moving data across hardware such that data in the same warp will be processed through similar paths. A common issue among prior implementations of TDR is the synchronous nature of its remapping and processing cycles, which exhaustively sort data produced by prior processing passes and exhaustively evaluate the sorted data. In another work, we defined a method of remapping data through an asynchronous scheduler which allows for work to be stored in shared memory and deferred arbitrarily until that work is a viable option for low-divergence evaluation. This article surveys a wider set of cases, with the goal of characterizing performance trends across a more comprehensive set of parameters. These parameters include cross sections of scattering/capturing/fission, use of implicit capture, source neutron counts, simulation time spans, and tuned memory allocations. Across these cases, we have recorded minimum and average execution times, as well as a heuristically tuned near-optimal memory allocation size for both synchronous and asynchronous scheduling. Across the collected data, it is shown that the asynchronous method is faster and more memory efficient in the majority of cases, and that it requires less tuning to achieve competitive performance.

Computer Science↗

Effects of exogenous GnRH administration on lambing performance of oestrus‐synchronized Kazak ewes during the breeding season

Abstract The objective of this study was to investigate the effects of GnRH at insemination on lambing performance of Kazak ewes. Oestrus was synchronized in 774 adult Kazak ewes using an intravaginal sponge impregnated with flurogestone acetate. The sponge was left in the vagina for 12 days followed with an injection of 330 IU of eCG at sponge removal. Each ewe was inseminated twice at 48 h and 60 h after sponge removal. The treatment group ( n = 387) was intramuscularly injected at the first insemination with a dose of 25 μg GnRH and the control group ( n = 387) with saline solution. The results showed that GnRH administration significantly decreased the fertility rate. In addition, significant differences were observed between the two groups in terms of the twin birth rate, the abortion rate and the litter size. In conclusion, GnRH administration at insemination was not recommended in Kazak ewes undergoing the fixed time artificial insemination during the breeding season. The breed may be a critical determinant of the potential for the exploitation of GnRH application in sheep breeding programmes.

Zhang, Jing↗

Study and improvement of the trigger system in ICARUS

In recent years, intriguing experimental neutrino anomalies have emerged. If confirmed, they could hint at the presence of additional sterile neutrino states playing in neutrino mixing. The Short-Baseline Neutrino project at Fermilab aims to delve into these anomalies, utilizing three Liquid Argon Time Projection Chamber detectors along the Booster Neutrino Beam. The SBND detector serves as nearby instruments, while MicroBooNE and ICARUS function as far detectors and also explore the NuMI beam off-axis. A relevant aspect in the functioning of all SBN detectors is the trigger system, that determines which interactions are recorded. In particular, in ICARUS, it relies on the synchronization of prompt signals from scintillation light within the LAr-TPC, detected by a system of Photo-Multiplier Tubes, with the proton beam’s spill extraction. The existing majority-based logic of the trigger system could potentially be enhanced through adder boards that sum analog signals from PMTs in groups of 15. This sum-based triggering might aid in identifying events near TPC walls, where light is abundant but captured by only a few PMTs, potentially bypassing the majority condition. Comprehensive tests have been performed to characterize these adder boards.

43 PARTICLE ACCELERATORS↗

Coherent Combining for High‐Power Kerr Combs

Abstract Kerr frequency combs enable the miniaturization of comb sources for applications such as data communications and spectroscopy. However, due to the high field confinement and effective nonlinearity, Kerr combs typically operate with low output comb powers. While nonsolitonic Kerr combs operating in the normal group velocity dispersion (GVD) regime can access high pump‐to‐comb conversion efficiencies and relatively flat spectral profiles, many frequency comb applications require even higher comb‐line powers that are otherwise fundamentally unattainable without the use of optical amplifiers. A high efficient coherent beam combining of Kerr combs is demonstrated via on‐chip synchronization to greatly enhanced comb‐line powers. Two normal GVD Kerr combs are coherently combined for a 2.9 dB increase in comb power compared to a single comb while maintaining a high total pump‐to‐comb conversion efficiency of 26%. Lastly, it is shown that via spectral engineering of two normal GVD combs, it should be possible to significantly increase the spectral flatness of a combined comb. This platform enables fully integrated systems with powers that can readily exceed that of an individual comb system by more than an order of magnitude.

Kim, Bok Young↗

Experimental Demonstration of Ion Beam Cooling with Pulsed Electron Beam

Cooling ion beams at high energy is presently considered for several ion colliders, in order to achieve high luminosities by enabling a significant reduction of emittance of hadron beams. Electron beam at cooling channel in a few to tens MeV can be accelerated by a RF/SRF linac, and thus using bunched electrons to cool bunched ions. To study such cooling process, the DC electron gun of EC35 cooler at the storage ring CSRm, IMP was modified by pulsing the grid voltage. A 0.07-3.5 micro-second pulse length with a repetition frequency of less than 250 kHz and synchronized with the ion revolution frequency was obtained. The first experimental demonstration of cooling of a coasting and bunched ion beam by a pulsed electron beam was carried out. Data analysis indicates the bunch length shrinkage and the momentum spread reduction of bunched 12C+6 ion beam as evidence of cooling. A longitudinal grouping effect of the coasting ion beam by the electron pulses has also been observed*. In this paper, we will present experimental results and comparison to the simulation modelling, particularly on the bunched electron cooling data after carefully analyzing the beam diagnostic signals.

Zhang, Yuhong↗

Small Cell Carcinoma of the Urinary Bladder: A Retrospective, Multicenter Rare Cancer Network Study of 107 Patients

Purpose: Small cell carcinomas of the bladder (SCCB) account for fewer than 1% of all urinary bladder tumors. There is no consensus regarding the optimal treatment for SCCB. Methods and Materials: Fifteen academic Rare Cancer Network medical centers contributed SCCB cases. The eligibility criteria were as follows: pure or mixed SCC; local, locoregional, and metastatic stages; and age ≥18 years. The overall survival (OS) and disease-free survival (DFS) were calculated from the date of diagnosis according to the Kaplan-Meier method. The log-rank and Wilcoxon tests were used to analyze survival as functions of clinical and therapeutic factors. Results: The study included 107 patients (mean [±standard deviation, SD] age, 69.6 [±10.6] years; mean follow-up time, 4.4 years) with primary bladder SCC, with 66% of these patients having pure SCC. Seventy-two percent and 12% of the patients presented with T2-4N0M0 and T2-4N1-3M0 stages, respectively, and 16% presented with synchronous metastases. The most frequent curative treatments were radical surgery and chemotherapy, sequential chemotherapy and radiation therapy, and radical surgery alone. The median (interquartile range, IQR) OS and DFS times were 12.9 months (IQR, 7-32 months) and 9 months (IQR, 5-23 months), respectively. The metastatic, T2-4N0M0, and T2-4N1-3M0 groups differed significantly (P=.001) in terms of median OS and DFS. In a multivariate analysis, impaired creatinine clearance (OS and DFS), clinical stage (OS and DFS), a Karnofsky performance status <80 (OS), and pure SCC histology (OS) were independent and significant adverse prognostic factors. In the patients with nonmetastatic disease, the type of treatment (ie radical surgery with or without adjuvant chemotherapy vs conservative treatment) did not significantly influence OS or DFS (P=.7). Conclusions: The prognosis for SCCB remains poor. The finding that radical cystectomy did not influence DFS or OS in the patients with nonmetastatic disease suggests that conservative treatment is appropriate in this situation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ProPortal: a resource for integrated systems biology of Prochlorococcus and its phage

ProPortal (http://proportal.mit.edu/) is a database containing genomic, metagenomic, transcriptomic and field data for the marine cyanobacterium Prochlorococcus. Our goal is to provide a source of cross-referenced data across multiple scales of biological organization—from the genome to the ecosystem—embracing the full diversity of ecotypic variation within this microbial taxon, its sister group, Synechococcus and phage that infect them. The site currently contains the genomes of 13 Prochlorococcus strains, 11 Synechococcus strains and 28 cyanophage strains that infect one or both groups. Cyanobacterial and cyanophage genes are clustered into orthologous groups that can be accessed by keyword search or through a genome browser. Users can also identify orthologous gene clusters shared by cyanobacterial and cyanophage genomes. Gene expression data for Prochlorococcus ecotypes MED4 and MIT9313 allow users to identify genes that are up or downregulated in response to environmental stressors. In addition, the transcriptome in synchronized cells grown on a 24-h light–dark cycle reveals the choreography of gene expression in cells in a ‘natural’ state. Metagenomic sequences from the Global Ocean Survey from Prochlorococcus, Synechococcus and phage genomes are archived so users can examine the differences between populations from diverse habitats. Finally, an example of cyanobacterial population data from the field is included.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Analysis of and Tool Support for Transactional Memory on BG/Q

Martin Schindewolf worked during his internship at the Lawrence Livermore National Laboratory (LLNL) under the guidance of Martin Schulz at the Computer Science Group of the Center for Applied Scientific Computing. We studied the performance of the TM subsystem of BG/Q as well as researched the possibilities for tool support for TM. To study the performance, we run CLOMP-TM. CLOMP-TM is a benchmark designed for the purpose to quantify the overhead of OpenMP and compare different synchronization primitives. To advance CLOMP-TM, we added Message Passing Interface (MPI) routines for a hybrid parallelization. This enables to run multiple MPI tasks, each running OpenMP, on one node. With these enhancements, a beneficial MPI task to OpenMP thread ratio is determined. Further, the synchronization primitives are ranked as a function of the application characteristics. To demonstrate the usefulness of these results, we investigate a real Monte Carlo simulation called Monte Carlo Benchmark (MCB). Applying the lessons learned yields the best task to thread ratio. Further, we were able to tune the synchronization by transactifying the MCB. Further, we develop tools that capture the performance of the TM run time system and present it to the application's developer. The performance of the TM run time system relies on the built-in statistics. These tools use the Blue Gene Performance Monitoring (BGPM) interface to correlate the statistics from the TM run time system with performance counter values. This combination provides detailed insights in the run time behavior of the application and enables to track down the cause of degraded performance. Further, one tool has been implemented that separates the performance counters in three categories: Successful Speculation, Unsuccessful Speculation and No Speculation . All of the tools are crafted around IBM's xlc compiler for C and C++ and have been run and tested on a Q32 early access system.

97 MATHEMATICS AND COMPUTING↗

Use of Automated External Defibrillators

In an effort to improve survival from cardiac arrest, the American Heart Association (AHA) has promoted the Chain of Survival concept, describing a sequence of prehospital steps that result in improved survival after sudden cardiac arrest. These interventions include immediate deployment of emergency medical services, prompt cardiopulmonary resuscitation, early defibrillation when indicated, and early initiation of advanced medical care. Early defibrillation has emerged as the most important intervention with survival decreasing by 10% with each minute of delay in defibrillation. Ventricular Fibrillation (VF) is a condition in which there is uncoordinated contraction of the heart cardiac muscle of the ventricles in the heart, making them tremble rather than contract properly. VF is a medical emergency and if the arrhythmia continues for more than a few seconds, blood circulation will cease, and death can occur in a matter of minutes. During VF, contractions of the heart are not synchronized, blood flow ceases, organs begin to fail from oxygen deprivation and within 10 minutes, death will occur. When VF occurs, the victim must be defibrillated in order to establish the heart’s normal rhythm. On average, the wait for an ambulance in populated areas of the United States is about 11 minutes. In view of these facts, the EFCOG Electrical Safety Task Group initiated this review to evaluate the potential value of deployment and use of automated external defibrillators (AEDs) for treatment of SCA victims. This evaluation indicates the long term survival benefit to victims of SCA is high if treated with CPR plus defibrillation within the first 3-5 minutes after collapse. According to the American Heart Association (AHA), survival rates as high as 74% are possible if treatment and defibrillation is performed in the first 3 minutes. In contrast survival rates are only 5% where no AED programs have been established to provide prompt CPR and defibrillation. ["CPR statistics" American Heart Association] Early intervention with both CPR and defibrillation can result in high long-term survival rates for SCA, as demonstrated by a study investigating the beneficial effects of AED devices at Chicago’s O’Hare and Midway airports. The American Medical Association (AMA) advocates the widespread placement of AEDs [AMA Res. 413, A-02; Res. 424, A-04]; supports increasing government and industry funding for the purchase of AED devices; and encourages the American public to become trained in CPR and the use of AEDs. Some states, including Maryland, have enacted legislation requiring AED devices and a certified responder be available at high school and school-sponsored athletic events due the risk of SCA to athletes (the most common cause of death in young athletes). Ensuring AED availability at Department of Energy (DOE) sites would serve as a means of preventative intervention for over 14,000 DOE employees and 193,000 contract workers. It is estimated 1 per 1,000 adults 35 years of age and older will experience SCA in a given year.

99 GENERAL AND MISCELLANEOUS↗

NRC HEAF Tests: Imaging & Measurement Methodology Report

The 2018 NRC HEAF tests were conducted in Chalfont Pennsylvania at KEMA High Power Laboratory during the week of September 10th. These scoping tests were executed to determine the most effective measurement methodologies for future tests. The goal of Sandia’s Photometrics group was to provide high-speed quantitative and qualitative imaging of the arcing fault tests for the Nuclear Regulatory Commission. The measurement methods included visible high-speed imaging, high-speed high-dynamic range visible imaging, thermal imaging, and quantitative flow imaging. In addition, data fusion products were generated to visualize instrumentation data and imaging measurements. All imaging has been time synchronized to the start of the arcing event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗