Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Long-Term Creep of a Thin-Walled Inconel 718 Stirling Power-Convertor Heater Head Assessed

The Department of Energy and NASA have identified Stirling power convertors as candidate power supply systems for long-duration, deep-space science missions. A key element for qualifying the flight hardware is a long-term durability assessment for critical hot section components of the power convertor. One such critical component is the power convertor heater head. The heater head is a high-temperature pressure vessel that transfers heat to the working gas medium of the convertor, which is typically helium. An efficient heater head design is the result of balancing the divergent requirements of thin walls for increased heat transfer versus thick walls to lower the wall stresses and thus improve creep resistance and durability. In the current design, the heater head is fabricated from the Ni-base superalloy Inconel 718 (IN 718, Inco Alloys International, Inc., Huntington, WV). Although IN 718 is a mature alloy system (patented in 1962), there is little long-term (>50,000-hr) creep data available for thin-specimen geometries. Since thin-section properties tend to be inferior to thicker samples, it is necessary to generate creep data using specimens with the same geometry as the actual flight hardware. Therefore, one facet of the overall durability assessment program involves generating relatively short-term creep data using thin specimens at the design temperature of 649 C (1200 F).

Bowman, Randy R.↗

Permeability of Candidate Stirling Heater Head Materials Measured

Researchers at the NASA Glenn Research Center are evaluating high-temperature materials for Stirling heater heads for second- and third-generation Stirling radioisotope power systems that would help to increase the system efficiency to 30 to 35 percent and the system specific power to 8 to 10+ W/kg. Ceramic materials could make it possible for the convertor hot-end temperature to be increased to 1050 to 1200 C, in comparison to the current 650 C with an Inconel 718 heater head. A hermetically sealed Stirling heater head must retain a constant internal pressure of nearly 400-psi helium (He) throughout its useful life (120,000 hr) at the design operating temperature. Therefore, He permeability was measured for eight potential materials and compared with the permeability of the current heater head material, Inconel 718. The eight materials included silicon nitride (Si3N4), silicon dioxide (SiO2), both sintered and chemical vapor deposited (CVD) silicon carbide (SiC), alumina (Al2O3), two types of melt-infiltrated (MI) SiC/SiC composites, and a carbon/SiC composite (C/SiC). Glenn submitted samples of each material to Porous Materials, Inc., Ithaca, New York, for permeability analysis. At room temperature and 30-psi He, four materials--Si3N4, Al2O3, SiO2, and sintered SiC--demonstrated lower permeability than Inconel 718. The CVD SiC and all the composite materials were significantly more permeable to He than the baseline material.

Freedman, Marc R.↗

Infrared Heaters

The heating units shown in the accompanying photos are Panelbloc infrared heaters, energy savers which burn little fuel in relation to their effective heat output. Produced by Bettcher Manufacturing Corporation, Cleveland, Ohio, Panelblocs are applicable to industrial or other facilities which have ceilings more than 12 feet high, such as those pictured: at left the Bare Hills Tennis Club, Baltimore, Maryland and at right, CVA Lincoln- Mercury, Gaithersburg, Maryland. The heaters are mounted high above the floor and they radiate infrared energy downward. Panelblocs do not waste energy by warming the surrounding air. Instead, they beam invisible heat rays directly to objects which absorb the radiation- people, floors, machinery and other plant equipment. All these objects in turn re-radiate the energy to the air. A key element in the Panelbloc design is a coating applied to the aluminized steel outer surface of the heater. This coating must be corrosion resistant at high temperatures and it must have high "emissivity"-the ability of a surface to emit radiant energy. The Bettcher company formerly used a porcelain coating, but it caused a production problem. Bettcher did not have the capability to apply the material in its own plant, so the heaters had to be shipped out of state for porcelainizing, which entailed extra cost. Bettcher sought a coating which could meet the specifications yet be applied in its own facilities. The company asked The Knowledge Availability Systems Center, Pittsburgh, Pennsylvania, a NASA Industrial Applications Center (IAC), for a search of NASA's files

Source record↗

Programmable Thermostats for MPLM Shell Heater Control ULF1: Thermal Performances - 1

The Multi-Purpose Logistics Module (MPLM) is the primary carrier for "pressurized" logistics to and from the International Space Station (ISS). The MPLM is transported in the payload bay of the Space Shuttle and is docked to the ISS for unloading, and reloading, of contents within the ISS shirt sleeve environment. Foil heaters, controlled originally with bi-metallic thermostats, are distributed across the outside of the MPLM structure and are utilized to provide energy to the structure to avoid exposure to cold temperatures and prevent condensation. The existing bi-metallic, fixed temperature set point thermostats have been replaced with Programmable Thermostats Modules (PTMs) in the Passive Thermal Control Subsystem (PTCS) 28Vdc shell heater circuits. The goal of using the PTM thermostat is to improve operational efficiency of the MPLM on-orbit shell heaters by providing better shell temperature control via feedback control capability. Each heater circuit contains a programmable thermostat connected to an external temperature sensor, a Resistive Temperature Device (RTD), which is used to provide continuous temperature monitoring capability. Each thermostat has programmable temperature set points and control spans. The data acquisition system uses a standard RS-485 serial interface communications cable to provide digital control capability. The PTM system was designed by MSFC, relying upon ALTEC support for their integration within the MPLM system design, while KSC performed the installation and ground checkout testing of the thermostat and RS-485 communication cable on the MPLM FM1 flight module. The PTMs were used for the first time during the STS-121/ULF1.1 mission. This paper will describe the design, development and verification of the PTM system, as well as the PTM flight performance and comparisons with SINDA thermal model predictions.

Glasgow, Shaun↗

Structural Benchmark Creep Testing for Microcast MarM-247 Advanced Stirling Convertor E2 Heater Head Test Article SN18

This report provides test methodology details and qualitative results for the first structural benchmark creep test of an Advanced Stirling Convertor (ASC) heater head of ASC-E2 design heritage. The test article was recovered from a flight-like Microcast MarM-247 heater head specimen previously used in helium permeability testing. The test article was utilized for benchmark creep test rig preparation, wall thickness and diametral laser scan hardware metrological developments, and induction heater custom coil experiments. In addition, a benchmark creep test was performed, terminated after one week when through-thickness cracks propagated at thermocouple weld locations. Following this, it was used to develop a unique temperature measurement methodology using contact thermocouples, thereby enabling future benchmark testing to be performed without the use of conventional welded thermocouples, proven problematic for the alloy. This report includes an overview of heater head structural benchmark creep testing, the origin of this particular test article, test configuration developments accomplished using the test article, creep predictions for its benchmark creep test, qualitative structural benchmark creep test results, and a short summary.

life (durability)↗

Thermal Design and Flight Experience of the Mars Exploration Rover Spacecraft Computer-Controlled, Propulsion Line Heaters

This paper covers the design, thermal testing and flight experiences with the computer-controlled thermostats on the propulsion line heaters. Flight experience revealed heater control behavior with propellant loaded into the system and during thruster firings that was not observable during system level testing. Explanations of flight behavior, lessons learned, and suggestions for improvement of the propellant line heater design are presented in this paper.

propulsion lines↗

Design and Implementation of the MSL Cruise Propulsion Tank Heaters

This slide presentation reviews the design and the implementation of the heaters for the Mars Science Laboratory (MSL). The pressurized tanks store hydrazine that freezes at 2 C, this means that heaters are required to keep the hydrazine and the helium at 36 C for the trip to Mars. Using the TMG software the heat loss was analyzed, and a thermal model simulates a half full tank which yielded a 13W heating requirement for each hemisphere. Views of the design, and the heater are included.

Mars Science Laboratory (MSL)↗

Implementation of a self-controlling heater: A concept

Proposed heater uses its own temperature coefficient for sensing function. Heating power is supplied from current source, heater voltage containing temperature information. Dynamic stability is very high since there is no thermal lag as would exist with separate heater and sensor.

Strange, M. G.↗

Forced-convection peak heat flux on cylindrical heaters in water and refrigerant 113

An investigation was conducted of the peak heat flux on cylindrical heaters in a fluid flowing perpendicular to the major axis of the heater. The test fluids were water and Refrigerant 113. Heaters of 0.049 to 0.181 cm diameter were tested over a fluid velocity range of 10.1 to 81.1 cm/sec. The experimental results were observed to fall within two regions based on the vapor removal geometry: jets or sheets. Mathematical models for each region successfully correlated the data for both fluids.

Cochran, T. H.↗

Engineering analyses and design calculations of NASA, Langley Research Center hydrogen-air-vitiated heater with oxygen replenishment

The technical basis is presented for the design of the hydrogen-air-vitiated heater. The heater liner is subjected to a maximum thermal environment at a specified condition, where the combustion gas temperature, pressure and flow rate are 5000 F, 750 psia, and 11.0 lb/sec, respectively, and results in a heat flux of the order of 275 BTU/sec-sq ft. Cooling and stress analyses indicate that water is the logical choice for cooling of the combustor liner. A mixing analysis was undertaken to establish a good combination of combustor length and injector configuration. The analysis, using a conservative analytical approach, indicates a combustor length of the order of 5 ft combined with discrete fuel and oxidizer injection at an approximate 2-1/2 inch radial combustor position, and results in uniform combustion products at the heater exit for all specified envelope conditions.

Source record↗

Electrical gas heater with large flow range capability

Auxiliary heat transfer device in form to tightly-wound helical tube was incorporated into conventional heater design to provide hydrogen heater with turn-down ratio greater than 100. Device greatly increases low flow rate capacity of heater by providing maximum heat-transfer area for low mass flows.

Benson, B. A.↗

Heater improves cold-temperature capacity of silver-cadmium batteries

Eight heaters are included in 14-cell package to provide 14-Vdc. Each heater is 11-ohm self-adhesive strip placed across broad face of each pair of cells. They are installed before cells are wired. Heaters are in series and are connected through pair of redundant thermostats.

Webster, W. H., Jr.↗

Sealed-in-quartz resistance heater

Electric resistance quartz heater operates at 1,400 F without developing excessively hot spots that can fail prematurely. Since resistance element is sealed in quartz, heater can be used in hostile environments. Sealed construction also keeps heater from contaminating heated object.

Miller, C. G.↗

Resistance Heater Helps Stirling-Engine Research

Stirling engine heater head consists of 18 double-turn coils of tubing, each of which is tightly wrapped with resistance-heating element, through which working gas flows. Coils form a toroid about periphery of heater-head body. With new resistance heater, total circuit resistance can be selected independently of tube geometry by changing size of wires and/or number of wire wraps around each tube.

Hoehn, F. W.↗

Icing and De-Icing of a Propeller with Internal Electric Blade Heaters

An investigation has been made in the NACA Cleveland icing research tunnel to determine the de-icing effectiveness of an experimental configuration of an Internal electric propeller-blade heater. Two atmospheric Icing conditions and two propeller operating conditions were Investigated, In experiments with unheated blades and with heat applied to the blades both continuously and cyclically. Data are presented to show the effect of propeller speed., ambient air temperature and liquid-water concentration, and the duration of the heat-on and cycle times on the power requirements and de-Icing performance of the blade heaters. The extent of ice-covered area on the blades for various icing ax4 operating conditions has been determined. The largest iced area was obtained at the higher ambient-air temperatures and at low propeller speed. The ohord.wise extent of Icing In practically every case was greater than that covered by blade heaters. Adequate de-icing in the heated area with continuous application of heat was obtained with the power available but a maximum power, input of 1250 watts per blade was insufficient for cyclic de-Icing for the range of conditions investigated. Blade-surface temperature rates of rise of 0.2 to 0.7 F per second were obtained and the minimum cooling period for cyclic de-icing was found to be approximately 2-1/2 times the heating period.

Lewis, James P.↗

An Investigation Utilizing an Electrical Analogue of Cyclic Deicing of Hollow Steel Propellers with Internal Electric Heaters

A study has been made of the heating requirements for the cyclic de?icing of hollow steel propellers fitted with two types of internal electric heaters. Solutions to the transient?teat?flow equations depicting the cyclic de?icing of propellers were obtained by use of an electrical analogy. The study showed the impracticability of using an internal tubular heater and illustrated the advantages of employing an internal shoe?type heater, which distributes the heat more evenly to the blade surface. The importance of minimizing the thermal inertia of the system was demonstrated, and the magnitude of reductions in the total energy requirement made possible through reductions in the heating period was indicated.

Neel, Carr B., Jr.↗

Preliminary Investigation of Cyclic De-Icing of an Airfoil Using an External Electric Heater

An investigation was conducted in the NACA Lewis icing research tunnel to determine the characteristics and requirements of cyclic deicing of a 65,2-216 airfoil by use of an external electric heater. The present investigation was limited to an airspeed of 175 miles per hour. Data are presented to show the effects of variations in heat-on and heat-off periods, ambient air temperature, liquid-water content, angle of attack, and. heating distribution on the requirements for cyclic deicing. The external heat flow at various icing and heating conditions is also presented. A continuously heated parting strip at the airfoil leading edge was found necessary for quick, complete, and consistent ice removal. The cyclic power requirements were found to be primarily a function of the datum temperature and heat-on time, with the other operating and meteorological variables having a second-order effect. Short heat-on periods and high power densities resulted in the most efficient ice removal, the minimum energy input, and the minimum runback ice formations. The optimum chordwise heating distribution pattern was found to consist of a uniform distribution of cycled power density in the impingement region. Downstream of the impingement region the power density decreased to the limits of heating which, for the conditions investigated, extended from 5.7 percent chord on the upper surface of the airfoil to 8.9 percent chord on the lower surface. Ice removal did not take place at a heater surface temperature of 32 F; surface temperatures of approximately 50 to 100 F were required to effect removal. Better de-icing performance and greater energy savings would be possible with a heater having a higher thermal efficiency.

Lewis, James P.↗

Analysis of low-g heat transfer for a cryogenic oxygen pressurization heater

After the external tank separates from the Orbiter about 2000 pounds of residual liquid oxygen remain in the main propulsion system lines. The pressurization of liquid oxygen from a subcritical to a supercritical state by the use of the heaters of the PRSA tanks while in a low-g environment is investigated. The performance of the heaters while bringing the state of the substance from the subcritical state to the supercritical one is studied, with particular emphasis on the time the pressurization process takes, and the temperature of the heater as the process proceeds.

Rios, J.↗