Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIGH ENERGY ELECTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Why Are There so Few Reports of High-Energy Electron Drift Resonances? Role of Radial Phase Space Density Gradients

Models of monochromatic Pc5 (2–7 mHz) ultralow frequency (ULF) wave interactions with high energy (greater than ~1 MeV) electrons predict drift resonant interactions that can cause rapid radial transport and acceleration. There are few reports of electron drift resonance at energies greater than ~1 MeV, in contrast to lower energies; moreover, all previous reports occur in the aftermath of interplanetary shocks. These two facts are difficult to reconcile with theory and numerical simulations predicting that greater than ~1 MeV drift resonances should occur more often and in a wider variety of driving conditions. In this study, we show that a combination of observational sampling biases and nominal radial phase space density gradients is one explanation for this discrepancy between theory and observations. In particular, we examine electron dynamics in two case studies with very similar satellite coverage, solar wind conditions, and Pc5 wave properties, yet with different radial phase space density profiles. Using global wave and particle observations, we show that the events have vastly different particle responses despite having similar wave properties. Placing these results in context with past studies, we further show here that nominal radial PSD gradients near geostationary orbit can mask the expected drift resonance particle response and explain (1) the small number of past greater than ~1 MeV drift resonance reports and (2) the restriction of these reports to interplanetary shock events. We argue that future observational studies characterizing radial transport via drift resonance should examine global particle dynamics, including observations of the radial phase space density profile.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical transmittance of fused silica at elevated temperatures during high energy electron bombardment.

An experimental determination of the optical transmission of Corning 7940 UV and Suprasil I fused silica has been made. The LeRC dynamitron provided the equivalent ionizing radiation and high temperature that the transparent gas divider of an operating nuclear light bulb engine would experience. The irradiation induced absorption was measured at 2150 A, 2700 A, and 4500 A. The length of the irradiations were sufficient so that an equilibrium between radiation induced coloration and high temperature annealing was reached. The experimental results indicate a significant optical absorption, particularly at the shorter wavelength, which would make the use of fused silica in this concept questionable.

Smith, A. B.↗

The effect of high-energy electron radiation on poly(arylene ether)s

Thin films of four experimental poly(arylene ether)s of similar chemical structure were exposed to 1 MeV electrons while under high vacuum. The films received total exposures of 5 x 10 exp 7 and 1 x 10 exp 9 rads at a dose rate of 5 x 10 exp 7 rads/h and a pressure of 2 x 10 exp -7 torr. Films exposed to 5 x 10 exp 7 rads showed dramatic changes in molecular weight distribution. After exposures of 1 x 10 exp 9 rads the films were only partially soluble in chloroform and exhibited no detectable changes in the glass transition temperatures. Thin-film tensile properties were also altered by the exposure to electron radiation. The effect of the exposures as determined by various analyses is discussed.

Connell, J. W.↗

Quantitative Modeling of High-Energy Electron Scattering in Thick Samples Using Monte Carlo Techniques

Cryo-electron microscopy (cryo-EM) is a powerful tool for imaging biological samples but is typically limited by sample thickness, which is restricted to a few hundred nanometers depending on the electron energy. However, there is a growing need for imaging techniques capable of studying biological samples up to 10 µm in thickness while maintaining nanoscale resolution. This need motivates the use of mega-electron-volt scanning transmission electron microscopy (MeV-STEM), which leverages the high penetration power of MeV electrons to generate high-resolution images of thicker samples. In this study, we employ Monte Carlo simulations to model electron–sample interactions and explore the signal decay of imaging electrons through thick specimens. By incorporating material properties, interaction cross-sections for energy loss, and experimental parameters, we investigate the relationship between the incident and transmitted beam intensities. Key factors such as detector collection angle, convergence semi-angle, and the material properties of samples were analyzed. Our results demonstrate that the relationship between incident and transmitted beam intensities follows the Beer–Lambert law over thicknesses ranging from a few microns to several tens of microns, depending on material composition, electron energy, and collection angles. The linear depth of silicon dioxide reaches 3.9 µm at 3 MeV, about 6 times higher than that at 300 keV. Meanwhile, the linear depth of amorphous ice reaches 17.9 µm at 3 MeV, approximately 11.5 times higher than that at 300 keV. These findings are crucial for advancing the study of thick biological and semiconductor samples using MeV-STEM.

36 MATERIALS SCIENCE↗

Comparative Analysis of NOAA REFM and SNB3GEO Tools for the Forecast of the Fluxes of High-Energy Electrons at GEO

Reliable forecasts of relativistic electrons at geostationary orbit (GEO) are important for the mitigation of their hazardous effects on spacecraft at GEO. For a number of years the Space Weather Prediction Center at NOAA has provided advanced online forecasts of the fluence of electrons with energy >2 MeV at GEO using the Relativistic Electron Forecast Model (REFM). The REFM forecasts are based on real-time solar wind speed observations at L1. The high reliability of this forecasting tool serves as a benchmark for the assessment of other forecasting tools. Since 2012 the Sheffield SNB3GEO model has been operating online, providing a 24 h ahead forecast of the same fluxes. In addition to solar wind speed, the SNB3GEO forecasts use solar wind density and interplanetary magnetic field B(sub z) observations at L1. The period of joint operation of both of these forecasts has been used to compare their accuracy. Daily averaged measurements of electron fluxes by GOES 13 have been used to estimate the prediction efficiency of both forecasting tools. To assess the reliability of both models to forecast infrequent events of very high fluxes, the Heidke skill score was employed. The results obtained indicate that SNB3GEO provides a more accurate 1 day ahead forecast when compared to REFM. It is shown that the correction methodology utilized by REFM potentially can improve the SNB3GEO forecast.

Balikhin, M. A.↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

Observation of High-Energy Electrons Precipitated by NWC Transmitter From PROBA-V Low-Earth Orbit Satellite

The very low-frequency transmitter in the Northwest Cape of Australia (NWC) has previously been observed to pitch-angle scatter electrons with energies from 30–400 keV, creating enhanced fluxes measured by low-Earth orbiting (LEO) satellites. Here we use observations from the Energetic Particle Telescope on PROBA-V. We compare the measured flux, as a function of local magnetic field strength, when the NWC transmitter is “on” versus “off,” and find enhanced fluxes only when NWC is “on” and located on the nightside. The enhanced fluxes occur in the population gradually transitioning from “permanently trapped” to “quasi-trapped.” We show that electrons up to 800 keV, substantially higher energy than previously studied, are scattered by resonant interactions with NWC to produce enhanced fluxes. The enhanced fluxes appear at multiple L-shells for each energy channel, consistent with resonance conditions at distinct wave normal angles, that indicate ducted interactions at L < 1.55 and unducted interactions at L > 1.65.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗