Electron calibration of instrumentation for low energy, high intensity particle measurements at Mercury

Unique identification of the high intensity, impulsively accelerated charged particle fluxes discovered during Mariner 10's first encounter with Mercury (March 1974) requires a detailed knowledge of the responses of the two University of Chicago charged particle telescopes to low energy fluxes over a wide dynamic range of flux levels. The results of detailed analyses show that these telescopes can separate and identify unambiguously the presence of electron and proton fluxes for a wide range of electron spectra and intensities in the relevant overall range of about 30 keV to 2 MeV.

Christon, S. P.↗

Atomic Oxygen (ATOX) simulation of Teflon FEP and Kapton H surfaces using a high intensity, low energy, mass selected, ion beam facility

A high intensity (greater than 10(exp 15) ions/sq cm) low energy (down to 5 eV) mass selected ion beam (MSIB) facility was used to study the effects of ATOX on two polymers commonly used for space applications (Kapton H and Teflon FEP). The polymers were exposed to O(+) and Ne(+) fluences on 10(exp 15) - 10(exp 19) ions/sq cm, using 30eV ions. A variety of analytical methods were used to analyze the eroded surfaces including: (1) atomic force microscopy (AFM) for morphology measurements; (2) total mass loss measurements using a microbalance; (3) surface chemical composition using x-ray photoelectron spectroscopy (XPS), and (4) residual gas analysis (RGA) of the released gases during bombardment. The relative significance of the collisional and chemical degradation processes was evaluated by comparing the effects of Ne(+) and O(+) bombardment. For 30 eV ions it was found that the Kapton is eroded via chemical mechanisms while Teflon FEP is eroded via collisional mechanisms. AFM analysis was found very powerful in revealing the evolution of the damage from its initial atomic scale (roughness of approx. 1 nm) to its final microscopic scale (roughness greater than 1 micron). Both the surface morphology and the average roughness of the bombarded surfaces (averaged over 1 micron x 1 micron images by the system's computer) were determined for each sample. For 30 eV a non linear increase of the Kapton roughness with the O(+) fluence was discovered (a slow increase rate for fluences phi less than 5 x 10(exp 17) O(+)/sq cm, and a rapid increase rate for phi greater than 5 x 10(exp 17) O(+)/sq cm). Comparative studies on the same materials exposed to RF and DC oxygen plasmas indicate that the specific details of the erosion depend on the simulation facility emphasizing the advantages of the ion beam facility.

Vered, R.↗

NASA's Functional Task Test: High Intensity Exercise Improves the Heart Rate Response to a Stand Test Following 70 Days of Bedrest

Cardiovascular adaptations due to spaceflight are modeled with 6deg head-down tilt bed rest (BR) and result in decreased orthostatic tolerance. We investigated if high-intensity resistive and aerobic exercise with and without testosterone supplementation would improve the heart rate (HR) response to a 3.5-min stand test and how quickly these changes recovered following BR. During 70 days of BR male subjects performed no exercise (Control, n=10), high intensity supine resistive and aerobic exercise (Exercise, n=9), or supine exercise plus supplemental testosterone (Exercise+T, n=8; 100 mg i.m., weekly in 2-week on/off cycles). We measured HR for 2 min while subjects were prone and for 3 min after standing twice before and 0, 1, 6, and 11 days after BR. Mixed-effects linear regression models were used to evaluate group, time, and interaction effects. Compared to pre-bed rest, prone HR was elevated on BR+0 and BR+1 in Control, but not Exercise or Exercise+T groups, and standing HR was greater in all 3 groups. The increase in prone and standing HR in Control subjects was greater than either Exercise or Exercise+T groups and all groups recovered by BR+6. The change in HR from prone to standing more than doubled on BR+0 in all groups, but was significantly less in the Exericse+T group compared to the Control, but not Exercise group. Exercise reduces, but does not prevent the increase in HR observed in response to standing. The significantly lower HR response in the Exercise+T group requires further investigation to determine physiologic significance.

Laurie, Steven S.↗

Optical Frequency Optimization of a High Intensity Laser Power Beaming System Utilizing VMJ Photovoltaic Cells

An effective form of wireless power transmission (WPT) has been developed to enable extended mission durations, increased coverage and added capabilities for both space and terrestrial applications that may benefit from optically delivered electrical energy. The high intensity laser power beaming (HILPB) system enables long range optical 'refueling" of electric platforms such as micro unmanned aerial vehicles (MUAV), airships, robotic exploration missions and spacecraft platforms. To further advance the HILPB technology, the focus of this investigation is to determine the optimal laser wavelength to be used with the HILPB receiver, which utilizes vertical multi-junction (VMJ) photovoltaic cells. Frequency optimization of the laser system is necessary in order to maximize the conversion efficiency at continuous high intensities, and thus increase the delivered power density of the HILPB system. Initial spectral characterizations of the device performed at the NASA Glenn Research Center (GRC) indicate the approximate range of peak optical-to-electrical conversion efficiencies, but these data sets represent transient conditions under lower levels of illumination. Extending these results to high levels of steady state illumination, with attention given to the compatibility of available commercial off-the-shelf semiconductor laser sources and atmospheric transmission constraints is the primary focus of this paper. Experimental hardware results utilizing high power continuous wave (CW) semiconductor lasers at four different operational frequencies near the indicated band gap of the photovoltaic VMJ cells are presented and discussed. In addition, the highest receiver power density achieved to date is demonstrated using a single photovoltaic VMJ cell, which provided an exceptionally high electrical output of 13.6 W/sq cm at an optical-to-electrical conversion efficiency of 24 percent. These results are very promising and scalable, as a potential 1.0 sq m HILPB receiver of similar construction would be able to generate 136 kW of electrical power under similar conditions.

Raible, Daniel E.↗

High Intensity Resistive and Rowing Exercise Countermeasures Do Not Prevent Orthostatic Intolerance Following 70 Days of Bed Rest

More than 60% of US astronauts participating in Mir and early International Space Station missions (greater than 5 months) were unable to complete a 10‐min 80 deg head‐up tilt test on landing day. This high incidence of post‐spaceflight orthostatic intolerance may be related to limitations of the inflight exercise hardware that prevented high intensity training. PURPOSE: This study sought to determine if a countermeasure program that included intense lower‐body resistive and rowing exercises designed to prevent cardiovascular and musculoskeletal deconditioning during 70 days of 6 deg head-down tilt bed rest (BR), a spaceflight analog, also would protect against post‐ BR orthostatic intolerance. METHODS: Sixteen males participated in this study and performed no exercise (Control, n=10) or performed an intense supine exercise protocol with resistive and aerobic components (Exercise, n=6). On 3 days/week, exercise subjects performed lower body resistive exercise and a 30‐min continuous bout of rowing (greater than or equal to 75% max heart rate). On 3 other days/week, subjects performed only high‐intensity, interval‐style rowing. Orthostatic intolerance was assessed using a 15‐min 80 deg head‐up tilt test performed 2 days (BR‐2) before and on the last day of BR (BR70). Plasma volume was measured using a carbon monoxide rebreathing technique on BR‐3 and before rising on the first recovery day (BR+0). RESULTS: Following 70 days of BR, tilt tolerance time decreased significantly in both the Control (BR‐2: 15.0 +/- 0.0, BR70: 9.9 +/- 4.6 min, mean +/- SD) and Exercise (BR‐2: 12.2 +/- 4.7, BR70: 4.9 +/- 1.9 min) subjects, but the decreased tilt tolerance time was not different between groups (Control: ‐34 +/- 31, Exercise: ‐56 +/- 16%). Plasma volume also decreased (Control: ‐0.56 +/- 0.40, Exercise: ‐0.48 +/- 0.33 L) from pre to post‐BR, with no differences between groups (Control: ‐18 +/- 11%, Exerciser: ‐15 +/-1 0%). CONCLUSIONS: These findings confirm previous reports in shorter BR studies that the performance of an exercise countermeasure protocol by itself during BR does not prevent orthostatic intolerance or plasma volume loss. This suggests that protection against orthostatic intolerance in astronauts following long‐duration spaceflight will require an additional intervention, such as periodic orthostatic stress, fluid repletion, and/or lower‐body compression garments.

Lee, Stuart M. C.↗

Review and meta-analysis of electron temperatures from high-intensity laser–solid interactions

The accelerated electron spectrum from high-intensity laser–solid interaction is often conveniently described using a Boltzmann distribution, whose temperature is known within the field as the hot-electron temperature. The importance of the electron temperature is highlighted by the sheer number of experimental and simulation studies on the subject over the past three decades. Recently, multi-kJ, multi-ps pulses have yielded electron spectra with temperatures far beyond the expected ponderomotive result. Expressions that predict the electron temperature considering laser parameters beyond intensity and wavelength have been developed, albeit using small datasets. In this review, we present what is, to the best of our knowledge, the largest dataset of electron temperatures gathered from experimental measurements and particle-in-cell simulations. This dataset allows us to compare existing analytical and empirical hot-electron temperature scaling models over a wide parameter range. We also develop new scaling models that incorporate the laser pulse duration of the laser and the plasma scale length. Three models that include pulse-duration and scale length dependence are especially successful at predicting both simulated and experimental data. The dataset will soon be made publicly available to encourage further investigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compensation of Third-order Resonances in the High Intensity Regime

As the Fermilab Accelerator Complex enters the high-intensity era, the Recycler Ring (RR) needs to mitigate the detrimental effect of third-order resonance crossing. Third-order resonance lines can be compensated to first order by cancelling out the global Resonance Driving Terms (RDTs) using the response matrix method. This compensation scheme has been proven to work at low intensities, i.e., in the single-particle regime. In order to evaluate the effectiveness of this compensation scheme at higher intensities, this study looks at dynamic and static tune scans, with and without resonance compensation, and different space charge tune shifts. Special care was taken in order to disentangle effects from space charge tune shift, structure resonances and space charge driven resonances.

43 PARTICLE ACCELERATORS↗

Reverberation Chamber Uniformity Validation and Radiated Susceptibility Test Procedures for the NASA High Intensity Radiated Fields Laboratory

The NASA Langley Research Center's High Intensity Radiated Fields Laboratory has developed a capability based on the RTCA/DO-160F Section 20 guidelines for radiated electromagnetic susceptibility testing in reverberation chambers. Phase 1 of the test procedure utilizes mode-tuned stirrer techniques and E-field probe measurements to validate chamber uniformity, determines chamber loading effects, and defines a radiated susceptibility test process. The test procedure is segmented into numbered operations that are largely software controlled. This document is intended as a laboratory test reference and includes diagrams of test setups, equipment lists, as well as test results and analysis. Phase 2 of development is discussed.

Koppen, Sandra V.↗

High intensity radiation heat source is capable of sustained operation

Water cooled, high intensity radiation source rated at 125 kw, with an efficiency of 31 to 34 percent is used in the evaluation of ablative materials under simulated conditions of high velocity entry into planetary atmospheres. The source operates repeatedly at maximum power for periods of 10 to 20 minutes.

Geideman, W. A.↗

Improvement in surface fatigue life of hardened gears by high-intensity shot peening

Two groups of carburized, hardened, and ground spur gears that were manufactured from the same heat vacuum induction melted vacuum arc melted (VIM VAR) AISI 9310 steel were endurance tested for surface fatigue. Both groups were manufactured with a standard ground 16 rms surface finish. One group was subjected to a shot peening (SP) intensity of 7 to 9A, and the second group was subjected to a SP intensity of 15 to 17A. All gears were honed after SP to a surface finish of 16 rms. The gear pitch diameter was 8.89 cm. Test conditions were a maximum Hertz stress of 1.71 GPa, a gear temperature of 350 K, and a speed of 10000 rpm. The lubricant used for the tests was a synthetic paraffinic oil with an additive package. The following results were obtained: The 10 pct. surface fatigue (pitting) life of the high intensity (15 to 17A) SPed gears was 2.15 times that of the medium intensity (7 to 9A) SPed gears, the same as that calculated from measured residual stress at a depth of 127 microns. The measured residual stress for the high intensity SPed gears was 57 pct. higher than that for the medium intensity SPed gears at a depth of 127 microns and 540 pct. higher at a depth of 51 microns.

Townsend, Dennis P.↗

Digital control of high-intensity acoustic testing

To eliminate previous system instabilities and control high-intensity acoustic tests, a digital control vibration test system is modified by a software change. Three systems for the control of acoustic testing are compared: a hybrid digital/analog system, a digital vibration system, and the same digital vibration system modified by a software change to allow acoustic testing. It is shown that the hybrid system and the modified vibration system exhibit almost equal performance, although the hybrid system performs testing twice as fast. The development of a specialized acoustic test control system is justified since it costs far less than the general-purpose vibration control system. However, the latter is much easier to set up for a test, which is important in preventing overtesting of valuable spacecraft components.

Slusser, R. A.↗

Implementation of the NASA High Intensity Modal Impedance Tube

This paper provides a description of the High Intensity Modal Impedance Tube (HIMIT) and its use for the evaluation of acoustic liners. Tests conducted with two liners, one linear and one nonlinear, are used to evaluate the suitability of the HIMIT for evaluation at frequencies up to 6 kHz and sound pressure levels up to 155 dB. Two impedance eduction methods are used, one suitable for plane wave frequencies and the other applicable over the full frequency range. These educed impedances are compared against those computed with an impedance prediction method and against those educed with another zero-flow test rig. These results confirm that the HIMIT can be used with confidence for the evaluation of acoustic liners over these frequency and sound pressure level ranges.

impedance↗

WIRE SCANNER FOR HIGH INTENSITY BEAM PROFILE DIAGNOSITICS

A control and data acquisition system of a high speed wire scanner is developed for high intensity beam profile diagnostics. The control system of the wire scanner includes two IOCs, a Soft IOC and a VME IOC. The Soft IOC connects with an Aerotech Ensemble motor drive through EPCIS motor record and controls the movement of the wire scanner. An Electrical Input card samples the real-time position of the wire through an incremental encoder, and generates a pulse to synchronize a VME ADC data acquisition card, which digitizes and samples the beam-induced signal after pre-amplification. A VME Relay Output card is installed to control the Brake Solenoid and Actuator Solenoid. All the VME I/O cards are installed on one VME crate and controlled by the VME IOC. The system configuration and software of the wire scanner are under development.

Yan, J.↗