Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Mechanical energy storage device for hip disarticulation

An artificial leg including a trunk socket, a thigh section hingedly coupled to the trunk socket, a leg section hingedly coupled to the thigh section and a foot section hingedly coupled to the leg section is outlined. A mechanical energy storage device is operatively associated with the artificial leg for storage and release of energy during the normal walking stride of the user. Energy is stored in the mechanical energy storage device during a weight-bearing phase of the walking stride when the user's weight is on the artificial leg. Energy is released during a phase of the normal walking stride, when the user's weight is removed from the artificial leg. The stored energy is released from the energy storage device to pivot the thigh section forwardly about the hinged coupling to the trunk socket.

Vallotton, W. C.↗

Effect of thermally induced porosity on an as-HIP powder metallurgy superalloy

The impact of thermally induced porosity on the mechanical properties of an as-hot-isostatically-pressed and heat treated pressing made from low carbon Astroloy was determined. Porosity in the disk-shape pressing studied ranged from 2.6 percent at the bore to 1.4 percent at the rim. Tensile, yield strength, ductility, and rupture life of the rim of the porous pressing was only slightly inferior to the rim of sound pressings. The strength, ductility, and rupture life of the bore of the porous pressing was severely degraded compared to sound pressings. At strain ranges typical of commercial jet engine designs, the rim of the porous pressing had slightly inferior fatigue life to sound pressings.

Dreshfield, R. L.↗

Effects of thermally induced porosity on an as-HIP powder metallurgy superalloy

The effect of thermally induced porosity on the mechanical properties of an as-hot-isostatically pressed and heat-treated pressing made from low carbon Astroloy is examined. Tensile, stress-rupture, creep, and low cycle fatigue tests were performed and the results were compared with industrial acceptance criteria. It is shown that the porous pressing has a porosity gradient from the rim to the bore with the bore having 1-1/2% greater porosity. Mechanical properties of the test ring below acceptance level are tensile reduction in area at room temperature and 538 C and time for 0.1% creep at 704 C. It is also found that the strength, ductility, and rupture life of the rim are slightly inferior to those of the rim of the sound pressings, while those of the bore are generally below the acceptable level. At strain ranges typical of commercial aircraft engines, the low cycle fatigue life of the rim of the porous pressings is slightly lower than that of the sound pressings.

Dreshfield, R. L.↗

The effect of microstructure, temperature, and hold-time on low-cycle fatigue of As HIP P/M Rene 95

The effects of microstructure, temperature, plastic strain range, and hold time on the low-cycle fatigue (LCF) life were studied for Rene 95, an important Ni base superalloy used in jet engine disks. It was shown that the life could be varied by approximately an order of magnitude at elevated temperatures by simple heat treatments. The life was largest for the microstructure that promoted the most homogeneous deformation mode. The results are explained using the concept of a synergistic interaction between the deformation mode and boundary oxidation.

Bashir, S.↗

Deformation Behaviors of HIPped Foil Compared with Those of Sheet Titanium Alloys

Micromechanics-based modeling of composite material behaviors requires an accurate assessment of the constituent properties and behaviors. For the specific case of continuous-fiber-reinforced metal matrix composites (MMC's) manufactured from a foil/fiber/foil process, much emphasis has been placed on characterizing foil-based matrix materials that have been fabricated in the same way as the composite. Such materials are believed to yield mechanical properties and behaviors that are representative of the matrix constituent within the composite (in situ matrix). Therefore, these materials are desired for micromechanics modeling input. Unfortunately, such foils are extremely expensive to fabricate and procure because of the labor-intensive rolling process needed to produce them. As a potential solution to this problem that would maintain appropriately representative in situ properties, the matrix constituent could be characterized with sheet-based materials, which are considerably less expensive to manufacture than foils, are more readily procured, and result in fewer plies to obtain a desired panel thickness. The critical question is, however, does the consolidated sheet material exhibit the same properties and behaviors as do the consolidated foils? Researchers at NASA Lewis Research Center's Life Prediction Branch completed a detailed experimental investigation to answer this question for three titanium alloys commonly used in metal matrix composite form.

Castelli, Michael G.↗

Space systems engineering and risk management - joined at the hip

This paper explores the separate skills and capabilities practiced until now, and the powerful coupling to be achieved, practically and effectively, in implementing a space mission, from inception (pre-phase A) to the end of Operations (phase E). The use of risk assessment techniques in balancing cost risk against performance risk, and the application of the systems engineering team in these trades, is the key to achieving this new implementation paradigm.

systems engineering↗

It’s Hip To Be Square - Refurbishment of the NASA Langley National Transonic Facility Test Section Plenum Door

The “nearside” plenum door (NPD) at the 39-year-old NASA Langley Research Center (LARC) National Transonic Facility (NTF) has become increasingly recalcitrant during the opening /closing sequence. The NPD is the primary means of entry into the test section for personnel and for model installation. The sliding NPD hardware guide bearings have failed three (3) times within a one-year period and “quick fixes” were able to be made to guide rails, wheels and bearings to put the NPD back into operation. The NPD no longer can utilize a “quick fix” as the rolling hardware is at its limit for further modifications. This presentation will describe the NPD situation, the findings as to the cause of the periodic NPD failures, and the solution to remove, refurbish, and reinstall the NPD.

Test Facilities↗

Role of vestibular information in initiation of rapid postural responses

Patients with bilateral vestibular loss have difficulty maintaining balance without stepping when standing in tandem, on compliant surfaces, across narrow beams, or on one foot, especially with eyes closed. Normal individuals (with no sensory impairment) maintain balance in these tasks by employing quick, active hip rotation (a "hip strategy"). The absence of a hip strategy in vestibular patients responding to translations of a short support surface has previously been taken as evidence that the use of hip strategy requires an intact vestibular system. However, many tasks requiring hip strategy alter one or a combination of important system characteristics, such as initial state of the body (tandem stance), dynamics (compliant surfaces), or biomechanical limits of stability (narrow beams). Therefore, the balance deficit in these tasks may result from a failure to account for these support surface alterations when planning and executing sensorimotor responses. In this study, we tested the hypothesis that vestibular information is critical to trigger a hip strategy even on an unaltered support surface, which imposes no changes on the system characteristics. We recorded the postural responses of vestibular patients and control subjects with eyes closed to rearward support surface translations of varying velocity, in erect stance on a firm, flat surface. Subjects were instructed to maintain balance without stepping, if possible. Faster translation velocities (25 cm/s or more) produced a consistent pattern of early hip torque (first 400 ms) in control subjects (i.e., a hip strategy). Most of the patients with bilateral vestibular loss responded to the same translation velocities with similar torques. Contrary to our hypothesis, we conclude that vestibular function is not necessary to trigger a hip strategy. We postulate, therefore, that the balance deficit previously observed in vestibular patients during postural tasks that elicit a hip strategy may have been due to the sensorimotor consequences of the system alterations imposed by the postural tasks used in those studies. Preliminary results from two younger patients who lost vestibular function as infants indicate that age, duration of vestibular loss, and/or the timing of the loss may also be factors that can influence the use of hip strategy as a rapid postural response.

NASA Discipline Neuroscience↗

Manufacture of astroloy turbine disk shapes by hot isostatic pressing, volume 1

The Materials in Advanced Turbine Engines project was conducted to demonstrate container technology and establish manufacturing procedures for fabricating direct Hot Isostatic Pressing (HIP) of low carbon Astroloy to ultrasonic disk shapes. The HIP processing procedures including powder manufacture and handling, container design and fabrication, and HIP consolidation techniques were established by manufacturing five HIP disks. Based upon dimensional analysis of the first three disks, container technology was refined by modifying container tooling which resulted in closer conformity of the HIP surfaces to the sonic shape. The microstructure, chemistry and mechanical properties of two HIP low carbon Astroloy disks were characterized. One disk was subjected to a ground base experimental engine test, and the results of HIP low carbon Astroloy were analyzed and compared to conventionally forged Waspaloy. The mechanical properties of direct HIP low carbon Astroloy exceeded all property goals and the objectives of reduction in material input weight and reduction in cost were achieved.

Eng, R. D.↗

Kinematics and Kinetics of Squat and Deadlift Exercises with Varying Stance Widths

The primary motion of squat and deadlift exercise involves flexion and extension of the hips, knees, and ankles, but each exercise can be performed with variations in stance width. These variations may result in differing kinematics and ground reaction forces (GRF), which may in turn affect joint loading. PURPOSE: The purpose of this investigation was to compare ankle, knee, and hip kinematics and kinetics of normal squat (NS), wide-stance squat (WS), normal deadlift (ND), and sumo deadlift (SD). We hypothesized that hip joint kinematics and work at each joint would differ between exercise variations. METHODS: Six subjects (3 m/3 f; 70.0 plus or minus 13.7 kg; 168 plus or minus 9.9 cm) performed each lift in normal gravity on the ground-based version of the Advanced Resistive Exercise Device (ARED) used on the International Space Station. The ARED provided resistance with a combination vacuum tube/flywheel mechanism designed to replicate the gravitational and inertial forces of free weights. Subjects completed each lift with their 10-repetition maximum load. Kinematic data were collected at 250 Hz by a 12-camera motion-capture system (Smart-D, BTS Bioengineering, Milan, Italy), and GRF data were collected at 1000 Hz with independent force platforms for each leg (Model 9261, Kistler Instruments AG, Winterhur, Switzerland). All data were captured simultaneously on a single workstation. The right leg of a single lift for each motion was analyzed. Modeling software (OpenSim 2.2.0, Simbios, Palo Alto, CA) determined joint kinematics and net positive and negative work at each lower extremity joint. Total work was found as the sum of work across all joints and was normalized by system mass. Effect sizes and their 95% confidence intervals were computed between conditions. RESULTS: Peak GRF were similar for each lift. There were no differences between conditions in hip flexion range of motion (ROM). For hip adduction ROM, there were no differences between the NS, WS, and SD. However, hip adduction ROM was greater during the NS and SD than during the ND. Hip rotation ROM was greater during the WS than during the NS and SD, and was greater during the SD than during the ND. For knee and ankle flexion ROM, the ND, WS, and SD were not different, but ROM was greater during the NS than the ND and greater during the WS than the SD. Total eccentric work was greater during the WS than the SD. Otherwise, there were no differences in eccentric or concentric work between conditions. CONCLUSIONS: Although squat and deadlift exercises consist of similar motions, there are kinematic differences between them that depend on stance width. Total eccentric and concentric work are similar for different lifts, but differing kinematics may require activation of different musculature for each variation. With respect to each condition, in the ND the ROM of each joint tended to be less, and the WS tended to trade knee motion for hip motion. PRACTICAL APPLICATIONS: Knowledge of differences in kinematics and kinetics between different squat and deadlift variations is important for coaches and rehabilitation personnel to understand when prescribing exercise. Our results suggest that each variation of the squat and deadlift should be considered a separate exercise that may induce different long-term training effects.

DeWitt, John K.↗

Risk of Bone Fracture due to Spaceflight-induced Changes to Bone

The Human Research Program (HRP) is taking a biomechanical approach to assessing subsequent fracture risk in active astronauts as a consequence of spaceflight exposure. Triennial testing of active and retired astronauts continues as Space Medicine monitors for a premature diagnosis of primary osteoporosis, which is associated with age-related bone loss and skeletal fragility. This updated 2023 Fracture Evidence Report has expanded the description of skeletal changes to capture the full effects of spaceflight on bone: • Recent analysis of fractures from health records of the full astronaut cohort, suggests an increased incidence rate of hip and spine fractures in astronauts following longer spaceflight duration flights compared to incident rates found in shorter duration flights. • Routine preflight-to-postflight surveillance by DXA (dual-energy x-ray absorptiometry) does not provide the full detection of loss and recovery in the long-duration (LD) astronaut nor the full recovery of hip trabecular bone. • The inclusion of hip quantitative computed tomography (QCT) in flight studies delineates effects of spaceflight, of countermeasures, and of post-flight recovery on cortical and trabecular bone parameters—some of which are verified predictors of hip fracture in the aged. • QCT detects and compares the distinct countermeasure effects of the pharmaceutical alendronate and of resistive exercise (on the Advanced Resistive Exercise Device, ARED) in specific cortical and trabecular bone sub-regions during spaceflight. • A published comparison of QCT-determined loss rates of hip trabecular bone in LD astronauts compared to terrestrial cohorts suggest that accelerated loss rates in trabecular volumetric BMD (vBMD) during spaceflight might be analogous to skeletal effects of accelerated loss rates in females due to menopause, potentially leading to disruptions in trabecular microarchitecture. • A dataset of finite element (FE) estimates of hip bone strength in aging terrestrial cohorts (spanning astronaut age-range) provides comparative context for changes in the FE of hip bone strength in LD astronauts, including comparison (force unit of newton) to percentiles (50th, 75th, and 100th) of sex-matched aged humans with hip fractures. • Risk of fracture, due to the mechanical overloading of bones, is being updated with IMPACT, the next-generation tool suite for probabilistic risk assessment (PRA) for exploration missions being created by the Exploration and Medical Capability Element (ExMC) at NASA. IMPACT is currently in development and will not be included in this 2024 update. The risk for fracture necessitates understanding the relationship between applied loads to bone and the biomechanical competence of bone. The Risk for Early Onset Osteoporosis focuses on the weakened condition of bone (including development of new technologies, measurements of novel skeletal attributes, translation of multiple measures to an index of bone fragility, and interpretations of data used to reflect a weakened bone), while the Risk for Fracture assesses factors that influence the probability an astronaut would encounter applied loads exceeding the biomechanical competence of bones, resulting in fracture. This Evidence Report combines the research gaps and tasks associated with both risks.

Fracture↗

Testing of electroformed deposited iridium/powder metallurgy rhenium rockets

High-temperature, oxidation-resistant chamber materials offer the thermal margin for high performance and extended lifetimes for radiation-cooled rockets. Rhenium (Re) coated with iridium (Ir) allow hours of operation at 2200 C on Earth-storable propellants. One process for manufacturing Ir/Re rocket chambers is the fabrication of Re substrates by powder metallurgy (PM) and the application of Ir coatings by using electroformed deposition (ED). ED Ir coatings, however, have been found to be porous and poorly adherent. The integrity of ED Ir coatings could be improved by densification after the electroforming process. This report summarizes the testing of two 22-N, ED Ir/PM Re rocket chambers that were subjected to post-deposition treatments in an effort to densify the Ir coating. One chamber was vacuum annealed, while the other chamber was subjected to hot isostatic pressure (HIP). The chambers were tested on gaseous oxygen/gaseous hydrogen propellants, at mixture ratios that simulated the oxidizing environments of Earth-storable propellants. ne annealed ED Ir/PM Re chamber was tested for a total of 24 firings and 4.58 hr at a mixture ratio of 4.2. After only 9 firings, the annealed ED Ir coating began to blister and spall upstream of the throat. The blistering and spalling were similar to what had been experienced with unannealed, as-deposited ED Ir coatings. The HIP ED Ir/PM Re chamber was tested for a total of 91 firings and 11.45 hr at mixture ratios of 3.2 and 4.2. The HIP ED Ir coating remained adherent to the Re substrate throughout testing; there were no visible signs of coating degradation. Metallography revealed, however, thinning of the HIP Ir coating and occasional pores in the Re layer upstream of the throat. Pinholes in the Ir coating may have provided a path for oxidation of the Re substrate at these locations. The HIP ED Ir coating proved to be more effective than vacuum annealed and as-deposited ED Ir. Further densification is still required to match the integrity of chemically vapor deposited Ir coatings. Despite this, the successful long duration testing of the HIP ED Ir chamber, in an oxidizing environment comparable to Earth-storable propellants, demonstrated the viability of this Ir/Re rocket fabrication process.

Reed, Brian D.↗