Search NASA⌕ Search

SEARCH · Search NASA

Results for “HVAC control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Learning-Based Building Flexibility Estimation and Control to Improve Microgrid Economics and Resilience: Preprint

This paper proposes a learning-based building flexibility estimation and control framework to improve system economics and resilience. A data-driven building load flexibility model consisting of weather forecasting and estimating load consumption is proposed to quantify building heating, ventilation, and air conditioning (HVAC) load flexibility. A reinforcement learning-based microgrid controller is proposed to dispatch distributed generators, distributed energy resources, and build HVAC loads while taking flexibility information as one of the inputs. Simulation analysis is conducted on the model of a real microgrid in California. The effectiveness of the proposed learning-based building flexibility estimation and control in reducing microgrid energy costs and improving the sustainability of critical loads is demonstrated.

building load flexibility↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DFAT: A web-based toolkit for estimating demand flexibility in building-to-grid integration

Demand Flexibility Assessment Tool (DFAT) is an open source web-based tool that estimates the demand flexibility potential of common control strategies in commercial buildings. The toolkit features a demand flexibility estimation tool that contains two calculators, basic and advanced, based on the level of input of customer data. The basic version calculates demand shed metrics for the control strategy “global temperature adjustment” and “cycle on/off compressors” using customer building information, local weather data, and electrical meter data. The advanced version, which uses detailed HVAC equipment data, calculates demand flexibility metrics for control strategies such as static pressure reset, global temperature adjustment, and cycle on/off compressors. In addition to the demand flexibility estimation tool, this toolkit offers a benchmarking tool that helps facility operators, aggregators, and utility resource managers assess demand flexibility opportunities, quantify/verify performance, and compare their performance against that of their peers.

Leong, Michael↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Exploring Building Retrofit Strategies Using AutoBEM Under Future Weather Scenarios

This study evaluates the long-term effectiveness of energy conservation measures (ECMs) on building energy consumption using AutoBEM, a scalable modeling framework driven by the high-resolution Model America dataset. We simulated 18,951 buildings in Flagstaff, Arizona under four climate scenarios using Future Typical Meteorological Year (fTMY) weather files for six time periods spanning from 1980 to 2099. Six ECMs were analyzed across electricity and gas usage, including HVAC fuel-switching, insulation upgrades, and infiltration control. While some measures, such as reducing space infiltration by percentage, showed minimal or even negative impact on total energy savings at the aggregate level, they proved highly effective for specific building types. Conversely, HVAC electrification offers high gas reduction but shifts demand to electricity, highlighting critical trade-offs under different climate trajectories. Building-type-specific analysis under SSP5-RCP8.5 (2080–2099) revealed significant variation in ECM performance, underscoring the need for targeted retrofit strategies. This study demonstrates the power of combining fTMY projections with large-scale simulations to inform data-driven retrofit planning.

Chowdhury, Shovan [ORNL]↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The MIST /MIUS Integration and Subsystems Test/ laboratory - A testbed for the MIUS /Modular Integrated Utility System/ program

The MIUS (Modular Integrated Utility System) concept is to be an energy-conserving, economically feasible, integrated community utility system to provide five necessary services: electricity generation, space heating and air conditioning, solid waste processing, liquid waste processing, and residential water purification. The MIST (MIUS Integration and Subsystem Test) integrated system testbed constructed at the Johnson Space Center in Houston includes subsystems for power generation, heating, ventilation, and air conditioning (HVAC), wastewater management, solid waste management, and control and monitoring. The key design issues under study include thermal integration and distribution techniques, thermal storage, integration of subsystems controls and displays, incinerator performance, effluent characteristics, and odor control.

Beckham, W. S., Jr.↗

Risk-informed Hierarchical Control of Behind-the-Meter DERs with AMI Data Integration (Final Technical Report)

This project addresses several key barriers to implement the next generation demand response applications and provides a clear understanding of implementing hierarchical and standalone control using AMI data. Through this program, Eaton has developed and tested a meter-as-a-controller prototype with the help of other partners--- National Renewable Energy Laboratory (NREL), Electric Power Research Institute (EPRI), Pecan St Inc. (PSI), and Delaware Electric Cooperative (DEC). The controller can utilize residential controllable loads such as heating, ventilation, and air conditioner (HVAC), electric water heater and distributed energy resources like solar PV and battery energy storage systems for off-setting the demand that is required from the grid, thus providing reliable grid-services for demand reduction or peak shaving. The controller is also capable of coordinating the resources of the premises for better management and energy efficiency while meeting the comfort bound of the premises owner as quality-of-service. The development has been demonstrated in a three virtual-home setup at system performance lab of NREL with real appliances (HVAC, electric water heater, solar PV, and battery). The technology has also been proved through laboratory and field demonstration with successful interconnectivity (e.g., end-to-end communication and data exchange) between the residential appliances and utility through the RF network at Delaware Electric Co-op (DEC) in Delaware.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synchronization and Rebound Effects in Residential Loads

Increasing fuel prices and capacity investment deferral place an increasing demand for peak reduction from distribution level systems. Residential and commercial devices, such as HVAC systems and water heaters, are increasingly involved in load control programs, and their use may generate synchronization and rebound effects, such as artificial peaks caused by device optimization. While there have been concerns over device synchronization, few studies quantify the extent of this effect with numerical values. In this study, we attempt to investigate whether control efforts result in device synchronization or rebound effects. We focus on three clustering methods – Ward’s clustering, Euclidean K-means, and Density-based spatial clustering of applications with noise – to evaluate the extent of synchronization of a fleet of water heaters and HVAC systems in Atlanta, Georgia. Our findings show that synchronization and rebound effects are present in the neighborhood’s water heaters, but none were found in the HVAC systems. Further, high usage water heaters are more susceptible to synchronization and rebound effects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding and lighting control for load shedding measures to reduce the HVAC and lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 3%-10% daily peak demand reduction performance for applicable buildings, and 0.97% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexible Integration of Diverse HVAC Technologies in EnergyPlus via Python-Enabled Workflows

Analysis of advanced controls and novel system types is often not directly feasible in building energy simulation tools. Various techniques extend building energy simulation tool capabilities to allow the use of user-defined scripts and programs, but these approaches have limitations. The EnergyPlus Python plugin offers users new flexibility to use EnergyPlus to call an external Python module at specific points in the simulation, as well as to use Python to call EnergyPlus functionality through an application programming interface (API). This paper presents four case studies leveraging the EnergyPlus Python plugin to facilitate analysis of advanced controls and system types. The use of the Python plugin offers greater modularity and flexibility relative to previous approaches, is less error prone, and is simpler for users to adopt. The Python plugin allows EnergyPlus to be used in a more flexible manner and to accommodate the expanding realm of energy modeling applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗