Search NASA⌕ Search

SEARCH · Search NASA

Results for “HYDROGEN ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effects of Multiscale Phase-Mixing and Interior Conductance in the Lunar-like Pickup Ion Plasma Wake. First Results from 3-D Hybrid Kinetic Modeling

The study of multiscale pickup ion phase-mixing in the lunar plasma wake with a hybrid model is the main subject of our investigation in this paper. Photoionization and charge exchange of protons with the lunar exosphere are the ionization processes included in our model. The computational model includes the self-consistent dynamics of the light (hydrogen ions or hydrogen molecule ion or helium ion), and heavy (sodium ion ) pickup ions. The electrons are considered as a fluid. The lunar interior is considered as a weakly conducting body. In this paper we considered for the first time the cumulative effect of heavy neutrals in the lunar exosphere (e.g., Aluminum, Argon), an effect which was simulated with one species of sodium ion but with a tenfold increase in total production rates. We find that various species produce various types of plasma tail in the lunar plasma wake. Specifically, sodium ion and helium ion pickup ions form a cycloid-like tail, whereas the hydrogen ion or hydrogen molecule ion pickup ions form a tail with a high density core and saw-like periodic structures in the flank region. The length of these structures varies from 1:5 R(sub M) to 3:3 R(sub M) depending on the value of gyro radius for hydrogen ion or hydrogen molecule ion pickup ions. The light pickup ions produce more symmetrical jump in the density and magnetic field at the Mach cone which is mainly controlled by the conductivity of the interior, an effect previously unappreciated. Although other pickup ion species had little effect on the nature of the interaction of the Moon with the solar wind, the global structure of the lunar tail in these simulations appeared quite different when the hydrogen molecule ion production rate was high.

Lipatov, A.S.↗

Investigation of Lunar Regolith Reduction via Hydrogen Plasma in Different Plasma Environments

The team at NASA KSC explored the use of hydrogen plasma as a reducing agent for Lunar regolith simulant in order to prove the viability of oxygen extraction from oxides. The focus of this work was to investigate the hydrogen ion production of different plasma power sources. An optimization trade study was completed by maximizing the production of the hydrogen ion and comparing the amount produced to the energy consumed. Hydrogen ion production was determined via residual gas analysis and a rough calibration using injected water. The hydrogen ions reduce the oxides present in the Lunar regolith, forming an OH molecule, which can further react with the hydrogen environment to form water vapor. This water vapor can then be measured through a residual gas analysis. Through this study, it was found that a direct current (DC) glow discharge operating at approximately 1 torr in a hydrogen environment produced the largest amount of reduced regolith when compared with a nanosecond pulsed system and alternating current (AC) source. Radiofrequency devices beyond AC were not studied in this work. Although the DC source performed the best here, limitations in design and experiment setup/scalability may lead to the selection of an alternative plasma power source in the future.

Kenneth Engeling↗

Electron impact ionization of H

The results of theoretical calculations for the reactions between electrons and negative hydrogen atoms are discussed for an electron colliding with a negative hydrogen ion and neutralizing the hydrogen ion by stripping the loosely bound electron from it, and the two free electrons moving away. A semi-quantum description of the process is presented in which the target is described in terms of quantum mechanics, and the projectile electron is described in a classical fashion.

Faisal, F. H. M.↗

Transverse acceleration of oxygen ions by electromagnetic ion cyclotron resonance with broad band left-hand polarized waves

Central plasma sheet (CPS) ion conics are oxygen-dominated, with peak energies ranging from tens to hundreds of eV centered around pitch-angles between 115 and 130 degrees. Because of the lack of correlation between the CPS conics and the observed currents and/or electron beam-like structures, it is not likely that all of these conics are generated by interactions with electrostatic ion cyclotron waves or lower hybrid waves. Instead, it is suggested that the observed intense broad band electric field fluctuations in the frequency range between 0 and 100 Hz can be responsible for the transverse energization of the ions through cyclotron resonance heating with the left-hand polarized electromagnetic waves. This process is much more efficient for heating the oxygen ions than hydrogen ions, thus providing a plausible explanation of the oxygen dominance in CPS conics. Simple algebraic expressions are given from which estimates of conic energy and pitch angle can be easily calculated. This suggested mechanism can also provide some preheating of the oxygen ions in the boundary plasma sheet (BPS) where discrete aurorae form.

Chang, T.↗

Data Services Upgrade: Perfecting the ISIS-I Topside Digital Ionogram Database

The ionospheric topside sounders of the International Satellites for Ionospheric Studies (ISIS) program were designed as analog systems. More than 16,000 of the original telemetry tapes from three satellites were used to produce topside digital ionograms, via an analog-to-digital (A/D) conversion process, suitable for modern analysis techniques. Unfortunately, many of the resulting digital topside ionogram files could not be auto-processed to produce topside Ne(h) profiles because of problems encountered during the A/D process. Software has been written to resolve these problems and here we report on (1) the first application of this software to a significant portion of the ISIS-1 digital topside-ionogram database, (2) software improvements motivated by this activity, (3) N(sub e)(h) profiles automatically produced from these corrected ISIS-1 digital ionogram files, and (4) the availability via the Virtual Wave Observatory (VWO) of the corrected ISIS-1 digital topside ionogram files for research. We will also demonstrate the use of these N(sub e)(h) profiles for making refinements in the International Reference Ionosphere (IRI) and in the determination of transition heights from Oxygen ion to Hydrogen ion.

topside ionosphere↗

An investigation of satellites to the resonance lines in some hydrogen-like ions

An experimental and theoretical investigation was conducted on the origin of satellite to resonance lines of the hydrogen-like ions of boron, carbon, and nitrogen. A theta pinch was employed with a grazing incidence spectrograph to measure the wavelengths of the satellites. The spectroscopic data also provided an estimate of the satellite/resonance line intensity ratio. Wavelengths of spectral lines due to transition from doubly excited states were calculated by a Hartree-Fock computer program. Wave functions were also calculated and were used to obtain the oscillator strengths of the transitions. Experimental work confirmed that the lines investigated were not satellites but were due to highly ionized argon which was present as an impurity in the filling gas.

Jalufka, N. W.↗

Cell and method for electrolysis of water and anode

An electrolytic cell for converting water vapor to oxygen and hydrogen include an anode comprising a foraminous conductive metal substrate with a 65-85 weight percent iridium oxide coating and 15-35 weight percent of a high temperature resin binder. A matrix member contains an electrolyte to which a cathode substantially inert. The foraminous metal member is most desirably expanded tantalum mesh, and the cell desirably includes reservoir elements of porous sintered metal in contact with the anode to receive and discharge electrolyte to the matrix member as required. Upon entry of a water vapor containing airstream into contact with the outer surface of the anode and thence into contact with iridium oxide coating, the water vapor is electrolytically converted to hydrogen ions and oxygen with the hydrogen ions migrating through the matrix to the cathode and the oxygen gas produced at the anode to enrich the air stream passing by the anode.

Aylward, J. R.↗

Hydrogen hollow cathode ion source

A source of hydrogen ions is disclosed and includes a chamber having at one end a cathode which provides electrons and through which hydrogen gas flows into the chamber. Screen and accelerator grids are provided at the other end of the chamber. A baffle plate is disposed between the cathode and the grids and a cylindrical baffle is disposed coaxially with the cathode at the one end of the chamber. The cylindrical baffle is of greater diameter than the baffle plate to provide discharge impedance and also to protect the cathode from ion flux. An anode electrode draws the electrons away from the cathode. The hollow cathode includes a tubular insert of tungsten impregnated with a low work function material to provide ample electrons. A heater is provided around the hollow cathode to initiate electron emission from the low work function material.

Mirtich, M. J., Jr.↗

Overview of the High Performance Antiproton (HiPAT) Experiment

The annihilation of matter with antimatter represents the highest energy density of any known reaction, producing 10(exp 8) MJ/g, approximately 10 orders of magnitude more energy per unit mass than chemical based combustion. To take the first step towards using this energy for propulsion applications the NASA MSFC Propulsion Research Center (PRC) has initiated a research activity examining the storage of low energy antiprotons. Storage was identified as a key enabling technology since it builds the experience base necessary to understand the handling of antiprotons for virtually all utilization and high-density storage concepts. To address this need, a device referred to as the High Performance Antiproton Trap (HiPAT) is under development at the NASA MSFC PRC. The HiPAT is an electromagnetic system (Penning-Malmberg design) consisting of a 4 Tesla superconductor, a high voltage confinement electrode system (operation up to 20 KV), and an ultra high vacuum test section (operating in the 10(exp -12) torr range). The system was designed to be portable with an ultimate goal of maintaining 10(exp 12) charged particles with a half-life of 18 days. Currently, this system is being experimentally evaluated using normal matter ions which are cheap to produce and relatively easy to handle. These normal ions provide a good indication of overall trap behavior, with the exception of assessing annihilation losses. The ions are produced external to HiPAT using two hydrogen ion sources, with adjustable beam energy and current. Ion are transported in a beam line and controlled through the use of electrostatic optics. These optics serve to both focus and gate the incoming ions, providing microsecond-timed pulses that are dynamically captured by cycling the HiPAT electric containment field like a 'trap door'. The layout of this system more closely simulates the operations expected at an actual antiproton production facility where 'packets' of antiprotons with pulse widths measured in 100's of nanoseconds could be provided. Initial dynamic capture experiments have been performed with both trap and ton source system functioning at approximately 10% of maximum levels, minimizing the potential for extraneous effects. Dynamic trapping techniques demonstrated the successful capture of millions of hydrogen ions with good agreement with the predicted loading based on the timing sequence, trap electric field, and ion beam current. These techniques will be expanded to examine multiple shot capture or 'stacking' to increase the total number of ions stored within HiPAT.

Martin, James J.↗

The role of hydrogen in hot-salt stress corrosion cracking of titanium-aluminum alloys

Additional support is presented for the previously proposed role of hydrogen as an embrittling agent in hot-salt stress corrosion cracking of titanium-aluminum alloys. The main source of hydrogen formed during the reactions of titanium alloys with hot salt was identified as water associated with the salt. Hydrogen is produced by the reaction of an intermediate (hydrogen halide) with the alloy rather than from metal-water reactions. The fracture mode of precracked tensile specimens was ductile when the specimens were tested in air, and brittle when tests were made in high-pressure hydrogen. Stressed titanium-aluminum alloys also were cracked by bombardment with hydrogen ions produced in a proton accelerator. The approximate concentrations of the hydrogen ions in the alloys were calculated.

Ondrejcin, R. S.↗

Lower Hybrid Oscillations in Multicomponent Space Plasmas Subjected to Ion Cyclotron Waves

It is found that in multicomponent plasmas subjected to Alfven or fast magnetosonic waves, such as are observed in regions of the outer plasmasphere and ring current-plasmapause overlap, lower hybrid oscillations are generated. The addition of a minor heavy ion component to a proton-electron plasma significantly lowers the low-frequency electric wave amplitude needed for lower hybrid wave excitation. It is found that the lower hybrid wave energy density level is determined by the nonlinear process of induced scattering by ions and electrons; hydrogen ions in the region of resonant velocities are accelerated; and nonresonant particles are weakly heated due to the induced scattering. For a given example, the light resonant ions have an energy gain factor of 20, leading to the development of a high-energy tail in the H(+) distribution function due to low-frequency waves.

Khazanov, G. V.↗

In Vivo Model to Test Implanted Biosensors for Blood pH

Biosensors for monitoring physiologic data continuously through telemetry are available for heart rate, respiration, and temperature but not for blood pH or ions affected by hydrogen ion concentration. A telemetric biosensor for monitoring blood pH on-line could be used to identify and manage problems in fluid and electrolyte metabolism, cardiac and respiratory function during space flight and the acid-base status of patients without the need for venipuncture in patients on Earth. Critical to the development of biosensors is a method for evaluating their performance after implantation. Mature rats, prepared with jugular, cannulas for repeated blood samples, were exposed to a gas mixture containing high levels of carbon dioxide (7%) in a closed environment to induce mild respiratory acidosis. Serial blood gas and pH measurements in venous blood were compared with electrical responses from sensors implanted in the subcutaneous tissue. Animals became slightly tachypneic after exposure to excess CO2, but remained alert and active. After 5 minutes, basal blood pH decreased from 7.404 +/- 0.013 to 7.289 +/- 0.010 (p less than 0.001)and PC02 increased from 45 +/- 6 to 65 +/- 4 mm. Hg (p les than 0.001). Thereafter pH and blood gas parameters remained stable. Implanted sensors showed a decrease in millivolts (mV) which paralleled the change in pH and averaged 5-6 mV per 0.1 unit pH. Implanted sensors remained sensitive to modest changes in tissue pH for one week. A system for inducing acidosis in rats was developed to test the in vivo performance of pH biosensors. The system provides a method which is sensitive, rapid and reproducible in the same and different animals with full recovery, for testing the performance of sensors implanted in subcutaneous tissues.

Arnaud, Sara B.↗

Surface Passivation and Junction Formation Using Low Energy Hydrogen Implants

New applications for high current, low energy hydrogen ion implants on single crystal and polycrystal silicon grain boundaries are discussed. The effects of low energy hydrogen ion beams on crystalline Si surfaces are considered. The effect of these beams on bulk defects in crystalline Si is addressed. Specific applications of H+ implants to crystalline Si processing are discussed. In all of the situations reported on, the hydrogen beams were produced using a high current Kaufman ion source.

Fonash, S. J.↗