Search NASA⌕ Search

SEARCH · Search NASA

Results for “HYDROSTATIC PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Modeling of Cardiovascular Response to Weightlessness

It was the hypothesis of this Project that the Simple lack of hydrostatic pressure in microgravity generates several purely physical reactions that underlie and may explain, in part, the cardiovascular response to weightlessness. For instance, hydrostatic pressure within the ventricles of the heart may improve cardiac performance by promoting expansion of ventricular volume during diastole. The lack of hydrostatic pressure in microgravity might, therefore, reduce diastolic filling and cardiac performance. The change in transmural pressure is possible due to the difference in hydrostatic pressure gradients between the blood inside the ventricle and the lung tissue surrounding the ventricle due to their different densities. On the other hand, hydrostatic pressure within the vasculature may reduce cardiac inlet pressures because of the typical location of the heart above the hydrostatic indifference level (the level at which pressure remains constant throughout changes in gravity). Additional physical responses of the body to changing gravitational conditions may influence cardiovascular performance. For instance, fluid shifts from the lower body to the thorax in microgravity may serve to increase central venous pressure (CVP) and boost cardiac output (CO). The concurrent release of gravitational force on the rib cage may tend to increase chest girth and decrease pedcardial pressure, augmenting ventricular filling. The lack of gravity on pulmonary tissue may allow an upward shifting of lung mass, causing a further decrease in pericardial pressure and increased CO. Additional effects include diuresis early in the flight, interstitial fluid shifts, gradual spinal extension and movement of abdominal mass, and redistribution of circulatory impedance because of venous distention in the upper body and the collapse of veins in the lower body. In this project, the cardiovascular responses to changes in intraventricular hydrostatic pressure, in intravascular hydrostatic pressure and, to a limited extent, in extravascular and pedcardial hydrostatic pressure were investigated. A complete hydraulic model of the cardiovascular system was built and flown aboard the NASA KC-135 and a computer model was developed and tested in simulated microgravity. Results obtained with these models have confirmed that a simple lack of hydrostatic pressure within an artificial ventricle causes a decrease in stroke volume. When combined with the acute increase in ventricular pressure associated with the elimination of hydrostatic pressure within the vasculature and the resultant cephalad fluid shift with the models in the upright position, however, stroke volume increased in the models. Imposition of a decreased pedcardial pressure in the computer model and in a simplified hydraulic model increased stroke volume. Physiologic regional fluid shifting was also demonstrated by the models. The unifying parameter characterizing of cardiac response was diastolic ventricular transmural pressure (DVDELTAP) The elimination of intraventricular hydrostatic pressure in O-G decreased DVDELTAP stroke volume, while the elimination of intravascular hydrostatic pressure increased DVDELTAP and stroke volume in the upright posture, but reduced DVDELTAP and stroke volume in the launch posture. The release of gravity on the chest wall and its associated influence on intrathoracic pressure, simulated by a drop in extraventricular pressure4, increased DVDELTAP ans stroke volume.

Sharp, M. Keith↗

Nanotwinned alloys under high pressure

Nanotwinned alloys are of interest due to their high strength and ductility, but twin boundaries may not be stable under shear. Computational studies indicate that high hydrostatic pressure may suppress detwinning mechanisms. Here, in this study, we investigate the microstructural changes of nanotwinned-nanocrystalline copper-nickel and Inconel 725 alloys under quasi-hydrostatic pressures up to 50 gigapascals (GPa). The alloys are compressed in a diamond anvil cell. In-situ x-ray diffraction (XRD) and ex-situ transmission electron microscopy (TEM) were employed to monitor microstructural changes. Twin boundary deformation and grain growth occur at 11.4 GPa quasi-hydrostatic pressure in the copper-nickel alloy. Molecular dynamics (MD) simulations reveal that hydrostatic pressure causes elevated local shear stress at grain boundaries, which leads to atomic rearrangements. A superposition of hydrostatic and deviatoric pressures lead to partial dislocation mediated twin boundary migration. In contrast, the Inconel 725 alloy showed stable twin and grain boundaries up to a quasi-hydrostatic pressure of 12.7 GPa. Texture, high solid solution strengthening, and low stacking fault energy are hypothesized to the enhanced microstructural stability in Inconel 725.

36 MATERIALS SCIENCE↗

Portable self-contained pressure testing manifold and associated methods

A portable, case-enclosed pressure test manifold, configured to support both pneumatic and hydrostatic pressure testing, and comprising a downstream fluid path (e.g., a system test gauge, a ball valve, a system test port, a system relief valve, and other components/piping) and an upstream fluid path (e.g., a low-pressure gauge, a high-pressure gauge, and other components/piping). A regulator and/or the ball valve selectively operate the downstream fluid path, defining a hydrostatic pressure testing path, to receive a liquid; and the upstream fluid path in combination with the downstream fluid path, defining a pneumatic pressure testing path, to receive a gas. Manifold components are pressure rated based on use and are ASME Code B31.3 compliant. A flexible hose connects with either of the pneumatic pressure testing path and the hydrostatic pressure testing path of the manifold. The case includes parking receptables and a carrying handle configured to stow the hose during transport.

Milholland, Roger A.↗

Modeling of streamflow in a 30 km long reach spanning 5 years using OpenFOAM 5.x

Abstract. Developing accurate and efficient modeling techniques for streamflow at the tens-of-kilometers spatial scale and multi-year temporal scale is critical for evaluating and predicting the impact of climate- and human-induced discharge variations on river hydrodynamics. However, achieving such a goal is challenging because of limited surveys of streambed hydraulic roughness, uncertain boundary condition specifications, and high computational costs. We demonstrate that accurate and efficient three-dimensional (3-D) hydrodynamic modeling of natural rivers at 30 km and 5-year scales is feasible using the following three techniques within OpenFOAM, an open-source computational fluid dynamics platform: (1) generating a distributed hydraulic roughness field for the streambed by integrating water-stage observation data, a rough wall theory, and a local roughness optimization and adjustment strategy; (2) prescribing the boundary condition for the inflow and outflow by integrating precomputed results of a one-dimensional (1-D) hydraulic model with the 3-D model; and (3) reducing computational time using multiple parallel runs constrained by 1-D inflow and outflow boundary conditions. Streamflow modeling for a 30 km long reach in the Columbia River (CR) over 58 months can be achieved in less than 6 d using 1.1 million CPU hours. The mean error between the modeled and the observed water stages for our simulated CR reach ranges from −16 to 9 cm (equivalent to approximately ±7 % relative to the average water depth) at seven locations during most of the years between 2011 and 2019. We can reproduce the velocity distribution measured by the acoustic Doppler current profiler (ADCP). The correlation coefficients of the depth-averaged velocity between the model and ADCP measurements are in the range between 0.71 and 0.83 at 75 % of the survey cross sections. With the validated model, we further show that the relative importance of dynamic pressure versus hydrostatic pressure varies with discharge variations and topography heterogeneity. Given the model's high accuracy and computational efficiency, the model framework provides a generic approach to evaluate and predict the impacts of climate- and human-induced discharge variations on river hydrodynamics at tens-of-kilometers and decadal scales.

58 GEOSCIENCES↗

Arterial Pressure Gradients during Upright Posture and 30 deg Head Down Tilt

Gravity alters local blood pressure within the body so that arterial pressures in the head and foot are lower and higher, respectively, than that at heart level. Furthermore, vascular responses to local alterations of arterial pressure are probably important to maintain orthostatic tolerance upon return to the Earth after space flight. However, it has been difficult to evaluate the body's arterial pressure gradient due to the lack of noninvasive technology. This study was therefore designed to investigate whether finger arterial pressure (FAP), measured noninvasively, follows a normal hydrostatic pressure gradient above and below heart level during upright posture and 30 deg head down tilt (HDT). Seven healthy subjects gave informed consent and were 19 to 52 years old with a height range of 158 to 181 cm. A Finapres device measured arterial pressure at different levels of the body by moving the hand from 36 cm below heart level (BH) to 72 cm above heart level (AH) in upright posture and from 36 cm BH to 48 cm AH during HDT in increments of 12 cm. Mean FAP creased by 85 mmHg transitioning from BH to AH in upright posture, and the pressure gradient calculated from hydrostatic pressure difference (rho(gh)) was 84 mmHg. In HDT, mean FAP decreased by 65 mmHg from BH to AH, and the calculated pressure gradient was also 65 mmHg. There was no significant difference between the measured FAP gradient and the calculated pressure gradient, although a significant (p = 0.023) offset was seen for absolute arterial pressure in upright posture. These results indicate that arterial pressure at various levels can be obtained from the blood pressure at heart level by calculating rho(gh) + an offset. The offset equals the difference between heart level and the site of measurement. In summary, we conclude that local blood pressure gradients can be measured by noninvasive studies of FAP.

Sanchez, E. R↗

Switching skeletons: hydrostatic support in molting crabs

Skeletal support systems are essential for support, movement, muscular antagonism, and locomotion. Crustaceans shed their rigid exoskeleton at each molt yet are still capable of forceful movement. We hypothesize that the soft water-inflated body of newly molted crabs may rely on a hydrostatic skeleton, similar to that of worms and polyps. We measured internal hydrostatic pressure and the force exerted during claw adduction and observed a strong correlation between force and hydrostatic pressure, consistent with hydrostatic skeletal support. This alternation between the two basic skeletal types may be widespread among arthropods.

Non-NASA Center↗

Declining interstitial transsudation in man

Results and methodology of experimentation dealing with declining interstitial transsudation are discussed. Concepts of the formation of interstitial fluids are in agreement with measurements of calf volume in normal young women, in horizontal recumbency or after horizontal immersion. The volume of the calf is reduced when the hydrostatic pressure of the blood column is diminished under the phlebostatic level and when the external pressure is increased by the hydrostatic pressure of a water bath.

Demarchin, P.↗

Deep-Sea Video Cameras Without Pressure Housings

Underwater video cameras of a proposed type (and, optionally, their light sources) would not be housed in pressure vessels. Conventional underwater cameras and their light sources are housed in pods that keep the contents dry and maintain interior pressures of about 1 atmosphere (.0.1 MPa). Pods strong enough to withstand the pressures at great ocean depths are bulky, heavy, and expensive. Elimination of the pods would make it possible to build camera/light-source units that would be significantly smaller, lighter, and less expensive. The depth ratings of the proposed camera/light source units would be essentially unlimited because the strengths of their housings would no longer be an issue. A camera according to the proposal would contain an active-pixel image sensor and readout circuits, all in the form of a single silicon-based complementary metal oxide/semiconductor (CMOS) integrated- circuit chip. As long as none of the circuitry and none of the electrical leads were exposed to seawater, which is electrically conductive, silicon integrated- circuit chips could withstand the hydrostatic pressure of even the deepest ocean. The pressure would change the semiconductor band gap by only a slight amount . not enough to degrade imaging performance significantly. Electrical contact with seawater would be prevented by potting the integrated-circuit chip in a transparent plastic case. The electrical leads for supplying power to the chip and extracting the video signal would also be potted, though not necessarily in the same transparent plastic. The hydrostatic pressure would tend to compress the plastic case and the chip equally on all sides; there would be no need for great strength because there would be no need to hold back high pressure on one side against low pressure on the other side. A light source suitable for use with the camera could consist of light-emitting diodes (LEDs). Like integrated- circuit chips, LEDs can withstand very large hydrostatic pressures. If power-supply regulators or filter capacitors were needed, these could be attached in chip form directly onto the back of, and potted with, the imager chip. Because CMOS imagers dissipate little power, the potting would not result in overheating. To minimize the cost of the camera, a fixed lens could be fabricated as part of the plastic case. For improved optical performance at greater cost, an adjustable glass achromatic lens would be mounted in a reservoir that would be filled with transparent oil and subject to the full hydrostatic pressure, and the reservoir would be mounted on the case to position the lens in front of the image sensor. The lens would by adjusted for focus by use of a motor inside the reservoir (oil-filled motors already exist).

Cunningham, Thomas↗

Buckling of Orthotropic and Stiffened Conical Shells

Donnell type stability equations for thin circular orthotropic conical shells are presented and solved for external pressure, axial compression and combined loading. The solution is likewise applied to stiffened conical shells. Correlation with equivalent cylindrical shells yields a simple approximate stability analysis for orthotropic or ring-stiffened conical shells under hydrostatic pressure. The general instability of stiffened conical shells under hydrostatic pressure is also analysed by a more accurate approach. Preliminary experimental results for buckling of ring-stiffened conical shells under hydrostatic pressure are presented and discussed.

CONICAL SHELL↗

Heterostructure design to achieve high quality, high density GaAs 2D electron system with g -factor tending to zero

Hydrostatic pressure is a useful tool that can tune several key parameters in solid state materials. For example, the Landé g-factor in GaAs two-dimensional electron systems (2DESs) is expected to change from its bulk value g ≃ -0.44 to zero and even to positive values under sufficiently large hydrostatic pressure. Although this presents an intriguing platform to investigate electron-electron interaction in a system with g = 0, studies are quite limited because the GaAs 2DES density decreases significantly with increasing hydrostatic pressure. Here, we show that a simple model, based on pressure-dependent changes in the conduction band alignment, quantitatively explains this commonly observed trend. Furthermore, we demonstrate that the decrease in the 2DES density can be suppressed by more than a factor of 3 through an innovative heterostructure design.

Physics↗

Experiment 1: Orbital Processing of High-Quality Zn-Alloyed CdTe Compound Semiconductors

Zinc-alloyed cadmium telluride (Zn:CdTe) crystals were grown in unit gravity and in microgravity for comparative analysis. Two crystals were grown on USML-1/STS-50 in 1992, and two additional crystals were grown on USML-2/STS-73 in 1995. The Crystal Growth Furnace (CGF) in the seeded Bridgman-Stockbarger crystal growth geometry was utilized on both missions. Crystals grown on USML-1/STS-50 were found to have solidified with partial wall contact due to the near-absence of the hydrostatic pressure in microgravity, a residual g-vector that was not axial, and the nonwetting sample/ampoule wetting conditions. Crystals grown on USML-2/STS-73 included: a sample/ampoule identical to the USML-1/STS-73 sample/ampoule, with the addition of a restraining spring to simulate hydrostatic pressure internally, and a tapered ampoule which accomplished 2.2 cm of crystal growth without wall contact. Infrared transmission of all ground and flight samples was found to be 63-66 percent, very close to the theoretical 66 percent, suggesting good stoichiometric control. Infrared microscopy confirmed that the primary precipitates were Te and their size (1-10 microns) and density suggested that the flight- and ground-base samples experienced similar thermal histories. Longitudinal macrosegregation, calculated using scaling analysis, was predicted to be low. Nearly diffusion controlled growth was achieved even in unit gravity and macrosegregation data could be fit with a diffusion controlled model. Radial segregation was monitored and was found to vary with fraction solidified, particularly through the shoulder region, where the sample cross section was varying significantly. It was also disturbed in the flight samples in regions where asymmetric wall contact was noted. In regions where a steady state was established, the radial segregation was invariant within our experimental measurement error. Flight samples were found to be much higher in structural perfection than samples processed in unit gravity under identical growth conditions. In regions where solidification had occurred without wall contact, the free surfaces evidenced virtually no twinning, although twins appeared in the flight samples in regions of wall contact and were pervasive in the ground samples. These results were confirmed using optical microscopy and synchrotron x-ray white beam topography. Full-width half-maximum rocking curve widths (FWHM), recorded in arc-seconds, were significantly reduced from 20 a-s (1 g) to 9 a-s (micro-g) for the best regions of the crystals. The 9 a-s (FWHM) rocking curve value in the unconfined flight samples equals the best value reported terrestrially for this material. The ground samples exhibited a fully developed (111)[110] dislocation mosaic structure, whereas dislocations within the flight samples were discrete and no mosaic structure was evident. The defect density was quantitatively reduced from 75,000 (1 g) to 800 (micro-g) +/-50 percent. Dislocation etch pit density results were confirmed using transmission synchrotron white beam and monochromated beam topography. The low defect density is thought to have resulted from the near absence of hydrostatic pressure, which allowed the molten boule to solidify with little or no wall contact. This minimized the transfer of hoop stresses during solidification and post-solidification processing.

Larson, D. J., Jr.↗

Effect of non-stoichiometry and pressure on superconductivity in topological semimetal PdTe

Research into topological superconductivity has been at the forefront of condensed matter physics due to both fundamental interest and potential applications in quantum computing. PdTe, is such a superconductor with a transition temperature T c ∼ 4.5 K and exhibits a nontrivial topological electronic structure, thus receiving significant attention. We report an experimental and theoretical investigation of the pressure effect on superconductivity by applying chemical non-stoichiometry and hydrostatic pressure. While T c decreases with increasing pressure through electrical resistivity, magnetization, and specific heat measurements, chemical pressure has a distinct impact from hydrostatic pressure, which could increase T c by creating negative pressure via non-stoichiometric Pd x Te with x > 1. Accompanied with this is a sign change of the Hall coefficient from negative at x < 1 to positive at x > 1. This indicates extreme sensitivity of the electronic structure to chemical non-stoichiometry, which occurs as a Pd vacancy for x < 1 and Pd interstitial for x > 1.

nonstoichiometry↗

X-ray diffraction strains in laser-ablated aluminum, nickel, sodium, and invar: Pressures to 475 GPa

Dynamically compressed materials in longitudinal waves are described by two physical models: hydrostatic pressure, with equal, normal, principal stresses or material uniaxially strained in the wave propagation direction. These models are disparate, so experimental comparisons and evaluations are important. Polycrystalline material in a state of hydrostatic pressure will have no eccentricity of x-ray-diffracted Debye–Scherrer rings. A general three-dimensional solution of Bragg diffracted x rays based on principal crystallographic strains in the compression wave was found. The distortion of x-ray diffraction beams has been used for strain measurements; the analysis developed incorporates a strained reciprocal lattice and the incident x-ray beam. Strain-distorted Polanyi surfaces form an annulus of compression with an ellipsoid of revolution in reciprocal space, which is intersected by Ewald's sphere for Bragg diffraction. The in situ measurements for strain describe nanosecond diffraction evaluated using two planes, (hkl) and (h′k′l′), both in the same crystallographic phase. Diffraction from Al, Ni, Na, and Invar quantifies the compression axial strains in these materials: The compression axial ratios are 0.65, 1.05, 0.88, and 1.58 at pressures of 291, 402, 409, and 367 GPa for the respective materials. Crystal structure transformations with homogeneous pressurized stresses, mandating equal normal strains, should not be anticipated to agree with heterogeneous, uniaxially strained, and sheared crystalline phases. Measurements support in-plane strains increasing with pressure, p , in fcc and hcp aluminum as ε 22 = −0.21 p /TPa.

Alloys↗

Probing intraband excitations in ZrTe 5 : A high-pressure infrared and transport study

Zirconium pentatetelluride, ZrTe 5 , shows remarkable sensitivity to hydrostatic pressure. In this work we address the high-pressure transport and optical properties of this compound, on samples grown by flux and chemical vapor transport. The high-pressure resistivity is measured up to 2 GPa, and the infrared transmission up to 9 GPa. The dc conductivity anisotropy is determined using a microstructured sample. Together, the transport and optical measurements allow us to discern band parameters with and without the hydrostatic pressure, in particular the Fermi level, and the effective mass in the less conducting, out-of-plane direction. The results are interpreted within a simple two-band model characterized by a Dirac-type, linear in-plane band dispersion, and a parabolic out-of-plane dispersion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Glomerular hemodynamic alterations during acute hyperinsulinemia in normal and diabetic rats

Treatment of insulin dependent diabetes invariably requires exogenous insulin to control blood glucose. Insulin treatment, independent of other factors associated with insulin dependent diabetes, may induce changes that affect glomerular function. Due to exogenous delivery of insulin in insulin dependent diabetes entering systemic circulation prior to the portal vein, plasma levels of insulin are often in excess of that observed in non-diabetics. The specific effects of hyperinsulinemia on glomerular hemodynamics have not been previously examined. Micropuncture studies were performed in control (non-diabetic), untreated diabetic and insulin-treated diabetic rats 7 to 10 days after administration of 65 mg/kg body weight streptozotocin. After the first period micropuncture measurements were obtained, 5 U of regular insulin (Humulin-R) was infused i.v., and glucose clamped at euglycemic values (80 to 120 mg/dl). Blood glucose concentration in non-diabetic controls was 99 +/- 6 mg/dl. In control rats, insulin infusion and glucose clamp increased nephron filtration rate due to decreases in both afferent and efferent arteriolar resistance (afferent greater than efferent) resulting in increased plasma flow and increased glomerular hydrostatic pressure gradient. However, insulin infusion and glucose clamp produced the opposite effect in both untreated and insulin-treated diabetic rats with afferent arteriolar vasoconstriction resulting in decreases in plasma flow, glomerular hydrostatic pressure gradient and nephron filtration rate. Thromboxane A2 (TX) synthetase inhibition partially decreased the vasoconstrictive response due to acute insulin infusion in diabetic rats preventing the decrease in nephron filtration rate.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary↗

Effect of Vestibular Impairment on Cerebral Blood Flow Response to Dynamic Roll Tilt

Change to upright posture results in reductions in cerebral perfusion pressure due to hydrostatic pressure changes related to gravity. Since vestibular organs, specifically the otoliths, provide information on position relative to gravity, vestibular inputs may assist in adaptation to the upright posture. The goal of this study was to examine the effect of direct vestibular stimulation on cerebral blood flow (CBF). To examine the role of otolith inputs we screened 165 subjects for vestibular function and classified subjects as either normal or impaired based on ocular torsion. Ocular torsion, an indication of otolith function, was assessed during sinusoidal roll tilt of 20 degrees at 0.01 Hz (100 sec per cycle). Subjects with torsion one SD below the mean were classified as impaired while subjects one SD above the mean were considered normal. During one session subjects were placed in a chair that was sinusoidally rotated 25 degrees in the roll plane at five frequencies: 0.25 & 0.125 Hz for 80 sec, 0.0625 Hz for 160 sec and 0.03125 Hz and 0.015625 Hz for 320 sec. During testing, CBF (transcranial Doppler), blood pressure (Finapres), and end tidal CO2 (Puritan Bennet) were measured continuously. Ocular torsion was assessed from infrared images of the eyes. All rotations were done in the dark with subjects fixated on a red LED directly at the center of rotation. In the normal group, dynamic tilt resulted in significant changes in both blood pressure and cerebral blood flow velocity that was related to the frequency of stimulus. In contrast the impaired group did not show similar patterns. As expected normal subjects demonstrated significant ocular torsion that was related to stimulus frequency while impaired subjects had minimal changes. These data suggest that vestibular inputs have direct effects on cerebral blood flow regulation during dynamic tilt. Supported by NASA.

Serrador, J. M.↗

Dependence of the Elastic Stiffness Tensors of PETN, α‐RDX, γ‐RDX, ϵ‐RDX, ϵ‐CL‐20, DAAF, FOX‐7, and β‐HMX on Hydrostatic Compression

Abstract The dependence of the components of the elastic stiffness tensors (or elastic constants) of the organic explosives PETN, RDX, CL‐20, DAAF, FOX‐7, and HMX on hydrostatic pressure up to 10 GPa have been computed using dispersion‐corrected density functional theory. We report the evolution of lattice parameters and the non‐zero stiffnesses for the tetragonal, orthorhombic, and monoclinic crystal symmetries. Linear and quadratic dependencies of the components of the elastic stiffness tensors on volumetric compression and hydrostatic pressure are tabulated for use in single crystal plasticity models.

36 MATERIALS SCIENCE↗