Search NASA⌕ Search

SEARCH · Search NASA

Results for “HYGROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Small-Scale Drying: FY2020 Interim Report

This report documents the interim experimental status of small-scale drying tests currently being performed at Pacific Northwest National Laboratory. These small-scale drying tests are to develop the technical bases for sensors, techniques, and approaches that will be used to address the challenges faced when determining moisture content from gas samples taken at the North Anna Nuclear Generating Station for the High Burnup Demonstration Project. Specifically, the purpose of these tests is to support Sandia National Laboratories gas sample methods and analyses through a series of small-scale experiments. Key focus areas include performing tests to: • Correlate sample bottle measurements to in-cask conditions • Estimate the amount of trapped and absorbed water on cask features and surfaces that can contribute to water vapor • Assess the accuracy of the hygrometer used in the measurements under similar conditions • Identify additional methods for measuring humidity in casks easily and accurately using lessons-learned from Sandia National Laboratories, including direct gravimetric and isotopic tracer techniques. To address these topics this report outlines a series of five tests and any data collected to date that were planned for FY 2020 that include 1) humidity measurement method development, 2) gas bottle sampling tests, 3) surface drying tests on cladding, 4) small-scale drying of cladding, and 5) small-scale drying of guide-tube/dashpots. This interim report documents the experimental background, design and progress of these small-scale drying tests. Further data gathered will be summarized in the FY 2021 report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NCSU Flux Tower Data

NCSU Flux Tower Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument descripotion Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Sonic Anemometer, 3 Condensation Particle Counters, 1 SP2, 1 POPS Start Date: 2022-06-01 End Date: 2022-9-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU flux tower was located next to the AMF sampling pad. The flux tower consisted of a 10 m telescoping tower. Mounted at the top of the tower was a sonic anemometer (RM Young 8000) and a Krypton Hygrometer. A sample line (¼” conductive tubing) and communication line was laid to a trailer located underneath and slightly adjacent to the tower. The sample line brought aerosol inside the trailer at 4.5 L min-1, where it was distributed between 3 CPCs (TSI 3776c, Dc ~ 2.5 nm, TSI 3771, Dc ~10nm, and TSI 3772, Dc ~40 nm) with different size cuts. Also sampling was a printed particle optical spectrometer (POPS) and a single particle soot photometer (SP2). Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

Nitric oxide, water vapor, and ozone in the atmosphere as measured in SITU from an aircraft

As part of the instrument evaluation plan for the NASA Global Atmospheric Sampling Program, prototype instruments were tested aboard the NASA Convair 990 during four flights in January and February of 1974. All the data were taken in maritime air between Hawaii and San Francisco and between Hawaii and 155 deg W, 35 deg N. A chemiluminescent instrument was used to measure nitric oxide. Water vapor, which was measured by using an aluminum oxide hygrometer, ranged from 5.2 micro g/g to saturation. Ozone was measured by an instrument using the ultraviolet absorption technique and ranged up to 235 ppbv. Typical temporal plots of the concentrations of the three constituents are presented. All the constituents showed considerable spatial and day-to-day variation in concentration at each altitude flown. Measurements of the three constituents were made simultaneously at various altitudes between 7.6 and 12.5 km.

Briehl, D.↗

In situ measurements of nitric oxide, water vapour and ozone from an aircraft

This paper describes flight tests of prototype instruments for the NASA global atmospheric sampling program (GASP). Three gas sampling instruments were included in the installation: (1) a chemiluminescent nitric oxide monitor; (2) an ultraviolet absorption ozone monitor; and (3) an aluminum oxide water vapor hygrometer. Results indicate the range and kind of variability in NO, H2O, and O3 that can be expected in routine tropospheric air sampling. They have also demonstrated the need for increasing instrument sensitivities, particularly in NO measurement.

Briehl, D. C.↗

Development of advanced Czochralski growth process to produce low cost 150 kg silicon ingots from a single crucible for technology readiness

Six growth runs used the Kayex-Hameo Automatic Games Logic (AGILE) computer based system for growth from larger melts in the Mod CG2000. The implementation of the melt pyrometer sensor allowed for dip temperature monitoring and usage by the operator/AGILE system. Use of AGILE during recharge operations was successfully evaluated. The tendency of crystals to lose cylindrical shape (spiraling) continued to be a problem. The hygrometer was added to the Furnace Gas Analysis System and used on several growth runs. The gas chromatograph, including the integrator, was also used for more accurate carbon monoxide concentration measurements. Efforts continued for completing the automation of the total Gas Analysis System. An economic analysis, based on revised achievable straight growth rate, is presented.

Lane, R. L.↗

Propagation of sound through the Earth's atmosphere

The data collected at a pressure of one atmosphere for the different temperatures and relative humidities of the air-water vapor mixtures is summarized. The dew point hygrometer used in these measurements did not give reliable results for dew points much above the ambient room temperature. For this reason measurements were not attempted at the higher temperatures and humidities. Viscous wall losses in the resonant tube at 0 C so dominate the molecular relaxation of nitrogen, in the air-water vapor mixture, that reliable data could not be obtained using the free decay method in a resonant tube at one atmosphere. In an effort to obtain viable data at these temperatures, measurements were performed at a pressure of 10 atmospheres. Since the molecular relaxation peak is proportional to the pressure and the viscous losses are proportional to the inverse square root of the pressure the peak height should be measurable at the higher pressure. The tradeoff here is that at 10 atmospheres; the highest relative humidity attainable is 10 percent. The data collected at 10 atmospheres is also summarized.

Meredith, R. W.↗

Spacecraft contamination environment; Proceedings of the Meeting, Arlington, VA, May 4-6, 1982

Aspects of IECM debriefing are considered, taking into account preliminary results of the induced environment contamination monitor measurements of STS-2, the humidity monitor and dew point hygrometer, the induced environment contamination monitor cascade impactor, the optical effects module and passive sample array, temperature-controlled quartz crystal microbalance measurements on STS-2, camera/photometer results, the mass spectrometer, and a summary regarding the induced environment contamination monitor/space transport system. Other subjects explored are related to contamination management and control, contamination/optical degradation, and contamination assessments and measurements. Attention is given to approaches for controlling contamination before launch, the coronagraph as the ultimate device to monitor orbiting particulates in the Space Transport System environment, and the contamination sensitivity of typical mirror coatings.

Maag, C. R.↗

Water vapor content in the polar atmosphere measured by Lyman-alpha/OH fluorescence method

The water vapor of the polar stratosphere possibly plays an important role in various aeronomical processes; for example, OH radical formation through photodissociation of H2O, formation of water cluster ions, radiative energy transfer in the lower stratosphere, condensation onto particulate matter, and so on. In addition to these, it has been speculated, from the viewpoint of global transport and/or budget of water vapor, that the polar stratosphere functions as an active sink. STANFORD (1973) emphasized the existence of the stratospheric Cist cloud in the polar stratosphere which brought a large loss rate of stratospheric water vapor through a so-called freeze-out of cloud particles from the stratosphere into the troposphere. However, these geophysically interesting problems unfortunately remain to be solved, owing to the lack of measurements on water vapor distribution and its temporal variation in the polar stratosphere. The water vapor content measured at Syowa Station (69.00 deg S, 39.35 deg E), Antarctica using a balloon-borne hygrometer (Lyman - alpha/OH fluorescence type) is discussed.

Iwasaka, Y.↗

An airborne study of microwave surface sensing and boundary layer heat and moisture fluxes for Project FIFE

This is the third semiannual status report describing the University of Wyoming participation in project FIFE, under NASA Grant NAG 5-913. The reader is referred to the first and second semiannual status reports for this grant for descriptions of University of Wyoming participation in the field operations of 1987. This report is concerned with continuing analysis of field data. Most of the instrument calibration effort has concentrated on interpretation and use of the high-rate water vapor measurements with the University of Wyoming Lyman-alpha device. In addition, fluxes of water vapor have been corrected for sensible heat flux, and all the high-rate (10 Hz for the Wyoming King Air) data have been filtered before the flux calculations. For each flight the Lyman-alpha data (10 Hz) are calibrated against the Cambridge dew-point hygrometer (1 Hz), by using data from the take-off sounding. The reasoning here is that the takeoff sounding (held to 500 fpm rate-of-climb specifically for the calibration) covers the widest range of humidity conditions of any sequence of the flight. For each takeoff sounding, then, the Lyman-alpha data, averaged to 1 Hz, are matched to the dewpoint data with a second-order least-squares fit. The resulting quadratic equation is then used in all subsequent analyses to convert the Lyman-alpha voltages to vapor desities for that specific flight. An alternative method is to use the range of fluctuation for the same two devices from horizontal passes to establish the calibration function. However, since the Lyman-alpha data are used only in the flux calculations, i.e., only the fluctuation and not the absolute values are used, this method is thought unnecessary.

Kelly, Robert D.↗

Atmospheric water mapping with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), Mountain Pass, California

Observations are given of the spatial variation of atmospheric precipitable water using the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) over a desert area in eastern California, derived using a band ratio method and the 940 nm atmospheric water band and 870 nm continuum radiances. The ratios yield total path water from curves of growth supplied by the LOWTRAN 7 atmospheric model. An independent validation of the AVIRIS-derived column abundance at a point is supplied by a spectral hygrometer calibrated with respect to radiosonde observations. Water values conform to topography and fall off with surface elevation. The edge of the water vapor boundary layer defined by topography is thought to have been recovered. The ratio method yields column abundance estimates of good precision and high spatial resolution.

Conel, James E.↗

Observation of organized structure in turbulent flow within and above a forest canopy

Data obtained with seven triaxial sonic anemometer/thermometers and three Lyman-alpha hygrometers at an experimental site in Ontario, Canada reveal the coherent occurrence of ramp patterns of temperature and humidity at several levels within and above the deciduous forest considered. The ramps appear most clearly in the middle and upper portion of the forest, and near the top of the forest they are composed of a weak ejecting motion transporting warm and/or moist air out of the forest, followed by strong sweeps of cool and/or dry air penetrating into the canopy. In the middle and upper parts of the canopy, the sweeps are found to conduct a large proportion of the overall transfer between the forest and the lower atmosphere, with a lesser contribution from ejections.

Gao, W.↗

Turbulence measurements using tethered balloon instrumentation during FIRE 1987

As part of the surface-based observations conducted on San Nicolas Island, the U.K. Meteorological Office operated a set of turbulence probes attached to a balloon tether cable. Typically six probes were used, each capable of measuring momentum, heat, and humidity fluxes. Two probes were fitted with net radiometers, one positioned above cloud and the other below; a third probe carried a Lyman-alpha hygrometer fitted with a pre-heater for the measurement of total water content. Some preliminary results are presented from the 14th July describing the variation in structure of the cloudy boundary layer during the daytime. This day was characterized by a complete cloud cover, an inversion height of approximately 600 m. and north-westerly winds of approximately 6 m.s(-1). As an illustration the equivalent potential temperature derived from a profile ascent made between approximately 0830 and 0930 (PDT) is shown. The data has been smoothed to a height resolution of about 4 metres. At this time the cloud base was approximately 200 m. and very light drizzle was reaching the surface. The vertical velocity variance and potential temperature flux for two periods are shown; the first (shown by full lines) immediately follows the profile and the second (shown by dashed lines) is central around 1400 (PDT). The data have been normalized by their maximum values in the first period. Cloud base has now risen to approximately 300 m. There is a marked variation during the morning, particularly in sigma w. The net radiative flux above cloud top has by now reached its maximum value.

Hignett, Phillip↗

Comparison of Stratospheric Aerosol and Gas Experiment II and balloon-borne stratospheric water vapor measurements

The Stratospheric Aerosol and Gas Experiment II has one channel at 940 nm related to water vapor. Two inversion procedures were developed independently in order to obtain the water vapor profile: the Chahine method by the Langley Research Center, and the Mill method by the Laboratoire d'Optique Atmospherique. Comparisons were made between these two algorithms and some results are presented at midlatitudes (about 45 deg N) and tropical latitudes (12-25 deg S). They are compared with in situ frost point hygrometer data provided by balloon experiments from the Laboratoire de Meteorologie Dynamique. At +/- 0.5 ppmv, agreement between the inversion results and the experimental results was obtained in the altitude range from 18-19 to 26-27 km. Below 18-19 km and above 26-27 km the error is larger (sometimes 1 ppmv and more).

Pruvost, P.↗

Water vapor and cloud water measurements over Darwin during the STEP 1987 tropical mission

Measurements of stratospheric and upper tropospheric cloud water plus water vapor (total water) and water vapor were made with two Lyman alpha hygrometers as part of the STEP tropical experiment. The in situ measurements were made in the Darwin, Australia, area in January and February of 1987 on an ER-2 aircraft. Average stratospheric water vapor at a potential temperature of 375 K (the average value of Theta at the tropopause) was 2.4 parts per million by volume (ppmv). This water mixing ratio is below the 3.0 to 4.0 ppmv necessary to be consistent with the observed upper stratospheric dryness. Saturation with respect to ice and the potential for dehydration was observed up to Theta = 402 K.

Kelly, K. K.↗

Aircraft observations of the vertical structure of stratiform precipitation relevant to microwave radiative transfer

The retrieval of rainfall intensity over the oceans from passive microwave observations is based on a radiative transfer model. Direct rainfall observations of oceanic rainfall are virtually nonexistent making validation of the retrievals extremely difficult. Observations of the model assumptions provide an alternative approach for improving and developing confidence in the rainfall retrievals. In the winter of 1983, the NASA CV-990 aircraft was equipped with a payload suitable for examining several of the model assumptions. The payload included microwave and infrared radiometers, mirror hygrometers, temperature probes, and PMS probes. On two occasions the aircraft ascended on a spiral track through stratiform precipitation providing an opportunity to study the atmospheric parameters. The assumptions concerning liquid hydrometeors, water vapor, lapse rate, and nonprecipitating clouds were studied. Model assumptions seem to be supported by these observations.

Chang, A. T. C.↗

Analysis of the GOES 6.7 micrometer channel observations during FIRE 2

Clouds form in moist environments. FIRE Phase II Cirrus Implementation Plan (August, 1990) noted the need for mesoscale measurements of upper tropospheric water vapor content. These measurements are needed for initializing and verifying numerical weather prediction models and for describing the environment in which cirrus clouds develop and dissipate. Various instruments where deployed to measure the water vapor amounts of the upper troposphere during FIRE II (e.g. Raman lidar, CLASS sonds and new cryogenic frost hygrometer on-board aircraft). The formation, maintenance and dissipation of cirrus clouds involve the time variation of the water budget of the upper troposphere. The GOES 6.7 mu m radiance observations are sensitive to the upper tropospheric relative humidity, and therefore proved extremely valuable in planning aircraft missions during the field phase of FIRE II. Warm 6.7 mu m equivalent black body temperatures indicate a relatively dry upper troposphere and were associated with regions generally free of cirrus clouds. Regions that were colder, implying more moisture was available may or may not have had cirrus clouds present. Animation of a time sequence of 6.7 mu m images was particularly useful in planning various FIRE missions. The 6.7 mu m observations can also be very valuable in the verification of model simulations and describing the upper tropospheric synoptic conditions. A quantitative analysis of the 6.7 mu m measurement is required to successfully incorporate these satellite observations into describing the upper tropospheric water vapor budget. Recently, Soden and Bretherton (1993) have proposed a method of deriving an upper tropospheric humidity based on observations from the GOES 6.7 mu m observations. The method is summarized in the next section. In their paper they compare their retrieval method to radiance simulations. Observations were also compared to ECMWF model output to assess the model performance. The FIRE experiment provides a unique opportunity to further verify the GOES upper tropospheric relative humidity retrieval scheme by providing (1) aircraft observations to cross-validate the calibration of the GOES 6.7 mu m channel, (2) accurate upper tropospheric water vapor concentrations for verification, and (3) veritical variability of upper tropospheric water vapor.

Soden, B. J.↗