Search NASASearch

SEARCH · Search NASA

Results for “Hand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Extravehicular activity self-rescue using a hand-held thruster

A study was performed in the virtual interactive environment workstation. Simulations were conducted to assess the feasibility and quantify the fuel and time requirements for a stranded crewperson to return to a space station after an accidental separation. A hand-held thruster, similar to the hand-held maneuvering unit from the Gemini program, was used for propulsion. Thirty different separation scenarios were composed of three separation rates, five initial spin rates, and an opportunity to use an attitude hold device in a repeated measures design. Statistically significant results were produced by separation velocity. Fuel, time maximum range, time to maximum range, maximum axial range, and final axial velocity increased with separation rate. A hand-held thruster is a viable alternative for accomplishing a self-rescue. Although one cannot prove a null effect, the fact that an attitude hold capability did not decrease solution time or fuel consumption is important for system designers. This fact, coupled with the success of a hand-held thruster in simulations, suggests that the added expense of more sophisticated solutions requiring a multitude of thrusters - and higher computation and power capabilities - may be unwarranted.

Brody, Adam R.

Force reflecting hand controller for manipulator teleoperation

A force reflecting hand controller based upon a six degree of freedom fully parallel mechanism, often termed a Stewart Platform, has been designed, constructed, and tested as an integrated system with a slave robot manipulator test bed. A force reflecting hand controller comprises a kinesthetic device capable of transmitting position and orientation commands to a slave robot manipulator while simultaneously representing the environmental interaction forces of the slave manipulator back to the operator through actuators driving the hand controller mechanism. The Stewart Platform was chosen as a novel approach to improve force reflecting teleoperation because of its inherently high ratio of load generation capability to system mass content and the correspondingly high dynamic bandwidth. An additional novelty of the program was to implement closed loop force and torque control about the hand controller mechanism by equipping the handgrip with a six degree of freedom force and torque measuring cell. The mechanical, electrical, computer, and control systems are discussed and system tests are presented.

Bryfogle, Mark D.

Conceptual design of a device to measure hand swelling in a micro-gravity environment

In the design of pressurized suits for use by astronauts in space, proper fit is an important consideration. One particularly difficult aspect of the suit design is the design of the gloves. If the gloves of the suit do not fit properly, the grip strength of the astronaut can be decreased by as much as fifty percent. These gloves are designed using an iterative process and can cost over 1.5 million dollars. Glove design is further complicated by the way the body behaves in a micro-gravity environment. In a micro-gravity setting, fluid from the lower body tends to move into the upper body. Some of this fluid collects in the hands and causes the hands to swell. Therefore, a pair of gloves that fit well on earth may not fit well when they are used in space. The conceptual design process for a device which can measure the swelling that occurs in the hands in a micro-gravity environment is described. This process involves developing a specifications list and function structure for the device and generating solution variants for each of the sub functions. The solution variants are then filtered, with the variants that violate any of the specifications being discarded. After acceptable solution variants are obtained, they are combined to form design concepts. These design concepts are evaluated against a set of criteria and the design concepts are ranked in order of preference. Through this process, the two most plausible design concepts were an ultrasonic imaging technique and a laser mapping technique. Both of these methods create a three dimensional model of the hand, from which the amount of swelling can be determined. In order to determine which of the two solutions will actually work best, a further analysis will need to be performed.

Hysinger, Christopher L.

A virtual work space for both hands manipulation with coherency between kinesthetic and visual sensation

This paper describes the construction of a virtual work space for tasks performed by two handed manipulation. We intend to provide a virtual environment that encourages users to accomplish tasks as they usually act in a real environment. Our approach uses a three dimensional spatial interface device that allows the user to handle virtual objects by hand and be able to feel some physical properties such as contact, weight, etc. We investigated suitable conditions for constructing our virtual work space by simulating some basic assembly work, a face and fit task. We then selected the conditions under which the subjects felt most comfortable in performing this task and set up our virtual work space. Finally, we verified the possibility of performing more complex tasks in this virtual work space by providing simple virtual models and then let the subjects create new models by assembling these components. The subjects can naturally perform assembly operations and accomplish the task. Our evaluation shows that this virtual work space has the potential to be used for performing tasks that require two-handed manipulation or cooperation between both hands in a natural manner.

Ishii, Masahiro

Force Model for Control of Tendon Driven Hands

Knowing the tendon forces generated for a given task such as grasping via a model, an artificial hand can be controlled. A two-dimensional force model for the index finger was developed. This system is assumed to be in static equilibrium, therefore, the equations of equilibrium were applied at each joint. Constraint equations describing the tendon branch connectivity were used. Gaussian elimination was used to solve for the unknowns of the Linear system. Results from initial work on estimating tendon forces in post-operative hands during active motion therapy were discussed. The results are important for understanding the effects of hand position on tendon tension, elastic effects on tendon tension, and overall functional anatomy of the hand.

Pena, Edward

Robot Hand

Robots are limited only by the dexterity of the hand. Dr. Salisbury, in conjunction with Stanford, Caltech and Jet Propulsion Laboratory, developed the Salisbury Hand which has three, three-jointed human-like fingers. The tips are covered with a resilient, high friction material for gripping. The robot hand can manipulate objects by finger motion, and adapts to different aims. Advanced software allows the hand to interpret information from fingertip sensors. Further development is expected. A company has been formed to reproduce the device; copies have been delivered to several laboratories.

Source record

Evolution of EF-hand calcium-modulated proteins. III. Exon sequences confirm most dendrograms based on protein sequences: calmodulin dendrograms show significant lack of parallelism

In the first report in this series we presented dendrograms based on 152 individual proteins of the EF-hand family. In the second we used sequences from 228 proteins, containing 835 domains, and showed that eight of the 29 subfamilies are congruent and that the EF-hand domains of the remaining 21 subfamilies have diverse evolutionary histories. In this study we have computed dendrograms within and among the EF-hand subfamilies using the encoding DNA sequences. In most instances the dendrograms based on protein and on DNA sequences are very similar. Significant differences between protein and DNA trees for calmodulin remain unexplained. In our fourth report we evaluate the sequences and the distribution of introns within the EF-hand family and conclude that exon shuffling did not play a significant role in its evolution.

Non-NASA Center

Removable hand hold

A hand hold utilizes joining mechanisms which comprises two different mounting brackets that are permanently fastened to a supporting structure. A slide plate is disposed at one end of the hand rail or hand hold which mates with one of the mounting brackets. A securing member is disposed at the opposite end of the hand rail/hand hold which connects with the other mounting bracket by means of a locking device. The slide plate has a central tapered tongue with two matching slots disposed on each side thereof.

Corrigan, Robert D.

Hand-Eye Calibration of Robonaut

NASA's Human Space Flight program depends heavily on Extra-Vehicular Activities (EVA's) performed by human astronauts. EVA is a high risk environment that requires extensive training and ground support. In collaboration with the Defense Advanced Research Projects Agency (DARPA), NASA is conducting a ground development project to produce a robotic astronaut's assistant, called Robonaut, that could help reduce human EVA time and workload. The project described in this paper designed and implemented a hand-eye calibration scheme for Robonaut, Unit A. The intent of this calibration scheme is to improve hand-eye coordination of the robot. The basic approach is to use kinematic and stereo vision measurements, namely the joint angles self-reported by the right arm and 3-D positions of a calibration fixture as measured by vision, to estimate the transformation from Robonaut's base coordinate system to its hand coordinate system and to its vision coordinate system. Two methods of gathering data sets have been developed, along with software to support each. In the first, the system observes the robotic arm and neck angles as the robot is operated under external control, and measures the 3-D position of a calibration fixture using Robonaut's stereo cameras, and logs these data. In the second, the system drives the arm and neck through a set of pre-recorded configurations, and data are again logged. Two variants of the calibration scheme have been developed. The full calibration scheme is a batch procedure that estimates all relevant kinematic parameters of the arm and neck of the robot The daily calibration scheme estimates only joint offsets for each rotational joint on the arm and neck, which are assumed to change from day to day. The schemes have been designed to be automatic and easy to use so that the robot can be fully recalibrated when needed such as after repair, upgrade, etc, and can be partially recalibrated after each power cycle. The scheme has been implemented on Robonaut Unit A and has been shown to reduce mismatch between kinematically derived positions and visually derived positions from a mean of 13.75cm using the previous calibration to means of 1.85cm using a full calibration and 2.02cm using a suboptimal but faster daily calibration. This improved calibration has already enabled the robot to more accurately reach for and grasp objects that it sees within its workspace. The system has been used to support an autonomous wrench-grasping experiment and significantly improved the workspace positioning of the hand based on visually derived wrench position. estimates.

Nickels, Kevin

Injury Risk Assessment of Extravehicular Mobility Unit (EMU) Phase VI and Series 4000 Gloves During Extravehicular Activity (EVA) Hand Manipulation Tasks

Functional Extravehicular Mobility Units (EMUs) with high precision gloves are essential for the success of Extravehicular Activity (EVA). Previous research done at NASA has shown that total strength capabilities and performance are reduced when wearing a pressurized EMU. The goal of this project was to characterize the human-space suit glove interaction and assess the risk of injury during common EVA hand manipulation tasks, including pushing, pinching and gripping objects. A custom third generation sensor garment was designed to incorporate a combination of sensors, including force sensitive resistors, strain gauge sensors, and shear force sensors. The combination of sensors was used to measure the forces acting on the finger nails, finger pads, finger tips, as well as the knuckle joints. In addition to measuring the forces, data was collected on the temperature, humidity, skin conductance, and blood perfusion of the hands. Testing compared both the Phase VI and Series 4000 glove against an ungloved condition. The ungloved test was performed wearing the sensor garment only. The project outcomes identified critical landmarks that experienced higher workloads and are more likely to suffer injuries. These critical landmarks varied as a function of space suit glove and task performed. The results showed that less forces were acting on the hands while wearing the Phase VI glove as compared to wearing the Series 4000 glove. Based on our findings, the engineering division can utilize these methods for optimizing the current space suit glove and designing next generation gloves to prevent injuries and optimize hand mobility and comfort.

Kilby, Melissa

Analysis of Potential Glove-Induced Hand Injury Metrics During Typical Neutral Buoyancy Training Operations

Injuries to the hands are common among astronauts who train for extravehicular activity. When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of NASA's Lifetime Surveillance of Astronaut Health's injury database reveals that 76 percent of astronaut hand and arm injuries from training between 1993 and 2010 occurred either to the fingernail, finger crotch, metacarpophalangeal joint, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure forces acting on the fingers and hand within pressurized gloves and other variables such as skin temperature, humidity, and fingernail strain of a NASA crewmember during typical NBL (Neutral Buoyancy Laboratory) training activity. During the 5-hour exercise, the crewmember seemed to exhibit very large forces on some fingers, resulting in higher strain than seen in previous glove-box testing. In addition, vital information was collected on the glove cavity environment with respect to temperature and humidity. All of this information gathered during testing will be carried forward into future testing, potentially in glove-box- or 1G- (1 gravitational force) or NBL-suited environments, to better characterize and understand the possible causes of hand injury amongst NASA crew.

McFarland, Shane

Effects of hand soldering MIL-PRF 55365 tantalum capacitors

Different values of MIL-PRF-55365 tantalum capacitors were subjected to three different types of soldering conditions— Convection Reflow, JPL Standard Hand Soldering, and Optimized Hand Soldering. The electrical parameters for a large number of capacitors of each value were measured before and after thermal soldering stress. The results indicate that tantalum capacitors subjected to convection reflow conditions experience detectable changes in electrical parameters; capacitors subjected to hand solder conditions show reduced changes in electrical parameters when compared to the reflow samples. Optimized hand solder conditions are shown to have a minimal effect on electrical parameters.

Sheldon, Douglas

Who Has the Upper HAND in a Hurricane? Flood Risk, Weather Shocks, and Property Prices

Flood risk is increasing in the United States, but how property markets respond to this hazard is unclear. Focusing on Houston, Texas, we analyze changes in flood risk capitalization in property prices after three major Gulf Coast hurricanes. Here, we compare two measures of flood risk–floodplain designations from the Federal Emergency Management Agency (FEMA), and a hydrologically-imputed, continuous measure, Height Above the Nearest Drainage (HAND). HAND affects property prices after a storm in intuitive ways, while we observe counterintuitive post-storm price premiums within FEMA floodplains. Plausibly exogenous measures like HAND may be useful tools for characterizing flood risk in economic analyses.

Plough, Julian A. [University of North Carolina, C

A proposed hand-tool assembly for robots

Terminator Kit Assembly (TKA) includes all features that mechanical manipulator needs to use hand tools for maintenance, repair, or assembly work. Tool box holds hand tools and, on command, releases them to hand interface which accepts and operates them. TKA is being studied as possible prosthetic device.

Dane, D. H.

Effect of hand-based sensors on manipulator control performance

The effect of hand based sensors (e.g tactile, force, and proximity sensors) on the performance of manipulator control is discussed. A brief overview is presented on various experimental hand based information systems which provide the manipulator controller some nonvisual awareness of the task environment. It is established that differences in manipulator task categories and motion phases require different hand based information systems to cope with control performance requirements.

Bejczy, A. K.

Three-Fingered Robot Hand

Mechanical joints and tendons resemble human hand. Robot hand has three "human-like" fingers. "Thumb" at top. Rounded tips of fingers covered with resilient material provides high friction for griping. Hand potential as prosthesis for humans.

Ruoff, C. F.

Kinematic rate control of simulated robot hand at or near wrist singularity

A robot hand should obey movement commands from an operator on a computer program as closely as possible. However, when two of the three rotational axes of the robot wrist are colinear, the wrist loses a degree of freedom, and the usual resolved rate equations (used to move the hand in response to an operator's inputs) are indeterminant. Furthermore, rate limiting occurs in close vicinity to this singularity. An analysis shows that rate limiting occurs not only in the vicinity of this singularity but also substantially away from it, even when the operator commands rotational rates of the robot hand that are only a small percentage of the operational joint rate limits. Therefore, joint angle rates are scaled when they exceed operational limits in a real time simulation of a robot arm. Simulation results show that a small dead band avoids the wrist singularity in the resolved rate equations but can introduce a high frequency oscillation close to the singularity. However, when a coordinated wrist movement is used in conjunction with the resolved rate equations, the high frequency oscillation disappears.

Barker, K.