Search NASA⌕ Search

SEARCH · Search NASA

Results for “Haptics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quantum chemical study of the structures and dynamic behavior of tricarbonyl complexes of Group 6 metals (Cr, Mo, W) with polyaromatic hydrocarbons using the density functional theory

The quantum chemical study of the mechanism was performed for tricarbonyl η{sup 6}-complexes of coronene I-M and kekulene II-M (M = Cr, Mo, W) by the density functional method. The activation barriers of η{sup 6},η{sup 6}-interring haptotropic rearrangements (IHR), being the migration of the metaltricarbonyl group M(CO){sub 3} from one six-membered aromatic ring to another, were determined. The processes of η{sup 6},η{sup 6}-IHR in the metal tricarbonyl complexes with relatively high polycyclic aromatic hydrocarbons (PAH) I and II occur with close energy barriers (ΔG{sup ≠} ≈ 20—25 kcal mol{sup –1}), which are lower than the barriers (ΔG{sup ≠} ~ 30 kcal mol{sup –1}) of similar transformations measured or calculated earlier for the chromium tricarbonyl complexes of naphthalene and its derivatives and other PAH. For the molybdenum tricarbonyl complexes the activation barriers of η{sup 6},η{sup 6}-IHR decrease additionally by ~ 5 kcal mol{sup –1} compared to those for the chromium tricarbonyl complexes, whereas for the tungsten tricarbonyl complexes they increase again and become approximately equal to the activation barriers of similar chromium tricarbonyl complexes. All stationary states on the potential energy surface determining the mechanism of η{sup 6},η{sup 6}-IHR are characterized by a decrease in hapticity compared to the initial and final complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

M IV /Co –I (M = Zr, Hf) Bis(phosphinoamide) Complexes with η 6 - and η 4 -Arenes

Despite their relevance to catalysis, low-/subvalent cobalt complexes are difficult to synthesize and isolate. Consequently, very few “cobaltate” complexes are known and there is a lack of architectural diversity in this field. Lewis acidic d 0 group IV metals have been demonstrated to stabilize Co –I centers via metal–metal bonds. Herein, we report the synthesis of bis(phosphinoamide) heterobimetallic M IV /Co –I arene complexes (M = Zr, Hf). The driving force to maintain the aromaticity of the arenes dictates the hapticity of the Co-bound arene ligands and influences the binding arrangement of the phosphinoamide ligands. Benzene and toluene were observed to bind η 6 to the Co –I center, forcing dissociation of one of the phosphinoamide ligands, whereas η 4 -coordination of anthracene allows both phosphinoamide ligands to remain bound to the Co center. The identity of both the arene and the group IV metal ion starkly influence the lability of the arene. For instance, the Co-bound benzene ligand in the Zr IV /Co –I benzene complex rapidly exchanges with C 6 D 6 in solution, whereas toluene/C 6 D 6 exchange is much slower and appreciable C 6 H 6 /C 6 D 6 exchange is not observed for the Hf analogue. The Zr IV /Co –I benzene complex loses benzene upon repeated exposure to vacuum to form an arene-free tetrametallic dimer.

aromatic compounds↗

Modeling of dielectric elastomer as electromechanical resonator

Dielectric elastomers (DEs) feature nonlinear dynamics resulting from an electromechanical coupling. Under alternating voltage, the DE resonates with tunable performances. We present an analysis of the nonlinear dynamics of a DE as electromechanical resonator (DEER) configured as a pure shear actuator. A theoretical model is developed to characterize the complex performance under different boundary conditions. Physical mechanisms are presented and discussed. Chaotic behavior is also predicted, illustrating instabilities in the dynamics. The results provide a guide to the design and application of DEER in haptic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A single-cell scraper based on an atomic force microscope for detaching a living cell from a substrate

We describe an atomic force microscope (AFM) manipulator that can detach a single, living adhesion cell from its substrate without compromising the cell's viability. The micrometer-scale cell scraper designed for this purpose was fabricated from an AFM micro cantilever using focused ion beam milling. The homemade AFM equipped with the scraper was compact and standalone and could be mounted on a sample stage of an inverted optical microscope. It was possible to move the scraper using selectable modes of operation, either a manual mode with a haptic device or a computer-controlled mode. The viability of the scraped single cells was evaluated using a fluorescence dye of calcein-acetoxymethl ester. Single cells detached from the substrate were collected by aspiration into a micropipette capillary glass using an electro-osmotic pump. As a demonstration, single HeLa cells were selectively detached from the substrate and collected by the micropipette. It was possible to recultivate HeLa cells from the single cells collected using the system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly dispersed Co deposited on Al 2 O 3 particles via CoCp 2 + H 2 ALD

Highly dispersed cobalt atoms were deposited on porous alumina particles using atomic layer deposition (ALD) with a CoCp 2 /H 2 chemistry at approximately 7 wt%. H 2 did not completely reduce the cyclopentadienyl organic ligands bound to deposited Co atoms at ALD reaction conditions. A sharp decline in Co deposited per cycle for two or more ALD cycles indicates that much of the Al 2 O 3 surface is sterically blocked from further CoCp 2 deposition after the first CoCp 2 exposure. Temperature programmed reduction confirmed that the adsorbed precursor organic ligands persist after H 2 exposures during ALD and temperatures as high as 500 °C are required to fully reduce the organic ligands to CH 4 . High resolution, element sensitive imaging showed that Co atoms were dispersed on the Al 2 O 3 surface and could deposit in previously unobserved multiple growth morphologies, specifically layers that were continuous over several angstroms or discrete nanoparticles. Density functional theory calculations were used to examine Co atom adsorption, show the altered haptic binding of cracked Cp ligands, and to calculate the thermodynamics of Cp ligand decomposition. The lateral steric hindrance between organic ligands bound to deposited Co atoms, Cp ligand decomposition mechanism, and local Al 2 O 3 surface termination all likely determine the observed Co growth morphology during initial ALD cycles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Small-scale roughness entraps water and controls underwater adhesion

While controlling underwater adhesion is critical for designing biological adhesives and in improving the traction of tires, haptics, or adhesives for health monitoring devices, it is hindered by a lack of fundamental understanding of how the presence of trapped water impedes interfacial bonding. Here, by using well-characterized polycrystal diamond surfaces and soft, nonhysteretic, low–surface energy elastomers, we show a reduction in adhesion during approach and four times higher adhesion during retraction as compared to the thermodynamic work of adhesion. Our findings reveal how the loading phase of contact is governed by the entrapment of water by ultrasmall (10-nanometer-scale) surface features. In contrast, the same nanofeatures that reduce adhesion during approach serve to increase adhesion during separation. The explanation for this counterintuitive result lies in the incompressibility-inextensibility of trapped water and the work needed to deform the polymer around water pockets. Unlike the well-known viscoelastic contribution to adhesion, this science unlocks strategies for tailoring surface topography to enhance underwater adhesion.

59 BASIC BIOLOGICAL SCIENCES↗

Rhodium mediated bond activation: from synthesis to catalysis

Recently, our lab has developed monoanionic tridentate ligand, To R , showing the corresponding coordination chemistry and catalyst reactivity of magnesium, zirconium, zinc and iridium complexes. This thesis details synthetic chemistry, structural study and catalytic reactivity of the To R -supported rhodium compounds. Tl[To R ] has been proved to be a superior ligand transfer agent for synthesizing rhodium complexes. The salt metathesis route of Tl[To M ] with [Rh(μ-Cl)(CO)] 2 and [Rh(μ- Cl)(COE)] 2 gives To M Rh(CO) 2 (2.2) and To M RhH(β 3 -C 8 H 13 ) (3.1) respectively while Tl[To M ] with [Rh(μ-Cl)(CO)] 2 affords To P Rh(CO) 2 (2.3). 2.2 reacts with both strong and weak electrophiles, resulting in the oxazoline N-attacked and the metal center-attacked compounds correspondingly. Using one of the metal center-attacked electrophiles, 2.3 was demonstrated to give high diastereoselectivity. Parallel to COE allylic C-H activation complex 3.1, the propene and allylbenzene allylic C-H activation products have also been synthesized. The subsequent functionalization attempts have been examined by treating with Brønsted acids, Lewis acids, electrophiles, nucleophiles, 1,3-dipolar reagents and reagents containing multiple bonds able to be inserted. Various related complexes have been obtained under these conditions, in which one of the azide insertion compounds reductively eliminates to give an allylic functionalization product stoichiometrically. 3.1 reacts with various primary alcohols to give the decarbonylation dihydride complex To M Rh(H) 2 CO (4.1). 4.1 shows catalytic reactivity for primary alcohol decarbonylation under a photolytic condition. Meanwhile, 2.2 has been found to be more reactive than 4.1 for catalytic alcohol decarbonylation under the same condition. Various complexes and primary alcohols have been investigated as well. The proposed mechanism is based on the stochiometric reactions of the possible metal and organic intermediates. Primary amines, hypothesized to undergo a similar reaction pathway, have been verified to give dehydrogenative coupling product, imines. In the end, the well-developed neutral tridentate Tpm coordinates to the rhodium bis(ethylene) dimer in the presence of TlPF 6 to give the cationic complex, [TpmRh(C 2 H 4 ) 2 ][PF 6 ] (5.1). 5.1 serves as the first example of explicit determination of the solid state hapticity, evidenced by X-ray structure, among all the cationic Tpm R M(C 2 H 4 ) 2 + (Tpm R = Tpm, Tpm*, M = Rh, Ir) derivatives. The substitution chemistry of this compound has been studied by treating with soft and hard donors. The trimethylphosphine-sbustituted complex activates molecular hydrogen to give the dihydride compound.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Virtual Reality for Shoot/No-Shoot Decision Training in Law Enforcement: A Literature Review and Research Agenda

Virtual reality (VR) can materially improve “shoot / no-shoot” (SNS) training by giving officers realistic, repeatable practice making high-stakes decisions under pressure. Traditional tools—live-fire ranges and video simulators—build basics, but they cannot adapt to each officer in real time or fully mirror the complexity of the field. VR closes that gap by creating immersive scenarios that are safer, more flexible, easier to scale across units, and able to capture objective performance data. SNS decisions are not just about marksmanship; they rely on perception, judgment, memory, and the ability to hold fire when a threat is uncertain. Effective training therefore needs realism, decision complexity, and branching outcomes that reflect the true consequences of choices. These elements strengthen recognition of hostile intent while reducing false positives and building the self-control required in ambiguous situations. VR brings specific advantages: dynamic environments, full-body interaction, and the ability to measure performance with precision—enabling targeted feedback and better transfer of learning to the street. At the same time, responsible deployment must address scenario quality (credible environments and behaviors), lawful decision models, and user wellbeing (appropriate stress levels, comfort, and safety). Sandia’s VIPER Lab is positioned to lead this work. The team combines human-performance science, AI/ML, and VR/AR development with a deep equipment bench (e.g., omnidirectional treadmill, eye-tracking, haptics, multiple HMDs). This ecosystem supports building and validating next-generation SNS training that is immersive, measurable, and trustworthy. Bottom line: Investment in VR-enabled SNS training that blends evidence-based design with careful validation and legal safeguards is expected to pay off in safer, more consistent decision-making and improved community trust, delivered through training that is practical to deploy at scale.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

CRCNS21 Computational Models of Multisensory Integration by Upper Limb in Humanoids and Amputees

This international collaborative research project between Johns Hopkins University (JHU) and the Technical University of Munich (TUM) investigated how the human brain processes and integrates multiple types of sensory information, such as touch and force, with the goal of improving prosthetic limbs for amputees and advancing sensory capabilities in humanoid robots. The research advanced our understanding of how the brain responds to sensory feedback in upper-limb amputees. Through experiments in which amputees received electrical stimulation while performing phantom hand movements, we demonstrated that sensory feedback activates the cortical sensorimotor and multisensory regions, and that these regions communicate dynamically during stimulation. Experiments with intact-limb participants explored the integration of visual, haptic, and force feedback, as well as in virtual reality motor training, further showing how the brain processes multimodal sensory information. In addition, this research inspired work on examining the reliability of where amputees perceive sensations over time, which contributed to a successful doctoral fellowship for continued investigation. Our collaborators at TUM improved multimodal sensor technology combining tactile and thermal feedback for humanoid robots, demonstrating the feasibility of integrating multiple sensor types into a unified system for detecting and responding to environmental stimuli. The experimental methods and analysis techniques developed across both teams, including functional network analysis and multimodal sensor integration, provide a foundation for future research in prosthetics and robotics. This research benefits the public by generating knowledge about how amputees process restored sensory information. Advances in humanoid sensing contribute to safer human-robot interaction. The project also fostered international collaboration and cross-disciplinary training: one TUM doctoral student spent a summer at JHU working on multimodal sensor integration, while two JHU students traveled to TUM to host workshops on neuromorphic sensory encoding and sensory integration.

42 ENGINEERING↗

Microgravity vestibular investigations (10-IML-1)

Our perception of how we are oriented in space is dependent on the interaction of virtually every sensory system. For example, to move about in our environment we integrate inputs in our brain from visual, haptic (kinesthetic, proprioceptive, and cutaneous), auditory systems, and labyrinths. In addition to this multimodal system for orientation, our expectations about the direction and speed of our chosen movement are also important. Changes in our environment and the way we interact with the new stimuli will result in a different interpretation by the nervous system of the incoming sensory information. We will adapt to the change in appropriate ways. Because our orientation system is adaptable and complex, it is often difficult to trace a response or change in behavior to any one source of information in this synergistic orientation system. However, with a carefully designed investigation, it is possible to measure signals at the appropriate level of response (both electrophysiological and perceptual) and determine the effect that stimulus rearrangement has on our sense of orientation. The environment of orbital flight represents the stimulus arrangement that is our immediate concern. The Microgravity Vestibular Investigations (MVI) represent a group of experiments designed to investigate the effects of orbital flight and a return to Earth on our orientation system.

Reschke, Millard F.↗

Implementation issues for a compact 6 degree of freedom force reflecting handcontroller with cueing of modes

Teleoperated control requires a master human interface device that can provide haptic input and output which reflect the responses of a slave robotic system. The effort reported in this paper addresses the design and prototyping of a six degree-of-freedom (DOF) Cartesian coordinate hand controller for this purpose. The device design recommended is an XYZ stage attached to a three-roll wrist which positions a flight-type handgrip. Six degrees of freedom are transduced and control brushless DC motor servo electronics similar in design to those used in computer controlled robotic manipulators. This general approach supports scaled force, velocity, and position feedback to aid an operator in achieving telepresence. The generality of the device and control system characteristics allow the use of inverse dynamics robotic control methodology to project slave robot system forces and inertias to the operator (in scaled form) and at the same time to reduce the apparent inertia of the robotic handcontroller itself. The current control design, which is not multiple fault tolerant, can be extended to make flight control or space use possible. The proposed handcontroller will have advantages in space-based applications where an operator must control several robot arms in a simultaneous and coordinated fashion. It will also have applications in intravehicular activities (within the Space Station) such as microgravity experiments in metallurgy and biological experiments that require isolation from the astronauts' environment. For ground applications, the handcontroller will be useful in underwater activities where the generality of the proposed handcontroller becomes an asset for operation of many different manipulator types. Also applications will emerge in the Military, Construction, and Maintenance/Manufacturing areas including ordnance handling, mine removal, NBC (Nuclear, Chemical, Biological) operations, control of vehicles, and operating strength and agility enhanced machines. Future avionics applications including advanced helicopter and aircraft control may also become important.

Jacobus, Heidi↗

Kinematic/Dynamic Characteristics for Visual and Kinesthetic Virtual Environments

Work was carried out on two topics of principal importance to current progress in virtual environment research at NASA Ames and elsewhere. The first topic was directed at maximizing the temporal dynamic response of visually presented Virtual Environments (VEs) through reorganization and optimization of system hardware and software. The final results of this portion of the work was a VE system in the Advanced Display and Spatial Perception Laboratory at NASA Ames capable of updating at 60 Hz (the maximum hardware refresh rate) with latencies approaching 30 msec. In the course of achieving this system performance, specialized hardware and software tools for measurement of VE latency and analytic models correlating update rate and latency for different system configurations were developed. The second area of activity was the preliminary development and analysis of a novel kinematic architecture for three Degree Of Freedom (DOF) haptic interfaces--devices that provide force feedback for manipulative interaction with virtual and remote environments. An invention disclosure was filed on this work and a patent application is being pursued by NASA Ames. Activities in these two areas are expanded upon below.

Bortolussi, Michael R.↗

Cognitive Sciences

Session MP4 includes short reports on: (1) Face Recognition in Microgravity: Is Gravity Direction Involved in the Inversion Effect?; (2) Motor Timing under Microgravity; (3) Perceived Self-Motion Assessed by Computer-Generated Animations: Complexity and Reliability; (4) Prolonged Weightlessness Reference Frames and Visual Symmetry Detection; (5) Mental Representation of Gravity During a Locomotor Task; and (6) Haptic Perception in Weightlessness: A Sense of Force or a Sense of Effort?

Source record↗

Simulation of Physical Experiments in Immersive Virtual Environments

An object-oriented event-driven immersive Virtual environment is described for the creation of virtual labs (VLs) for simulating physical experiments. Discussion focuses on a number of aspects of the VLs, including interface devices, software objects, and various applications. The VLs interface with output devices, including immersive stereoscopic screed(s) and stereo speakers; and a variety of input devices, including body tracking (head and hands), haptic gloves, wand, joystick, mouse, microphone, and keyboard. The VL incorporates the following types of primitive software objects: interface objects, support objects, geometric entities, and finite elements. Each object encapsulates a set of properties, methods, and events that define its behavior, appearance, and functions. A container object allows grouping of several objects. Applications of the VLs include viewing the results of the physical experiment, viewing a computer simulation of the physical experiment, simulation of the experiments procedure, computational steering, and remote control of the physical experiment. In addition, the VL can be used as a risk-free (safe) environment for training. The implementation of virtual structures testing machines, virtual wind tunnels, and a virtual acoustic testing facility is described.

Noor, Ahmed K.↗

Nanomanipulation and Lithography for Carbon Nanotube Based Nondestructive Evaluation Sensor Development

Carbon nanotubes (CNTs) offer great potential for advanced sensor development due to the unique electronic transport properties of the material. However, a significant obstacle to the realization of practical CNT devices is the formation of reliable and reproducible CNT to metallic contacts. In this work, scanning probe techniques are explored for both fabrication of metallic junctions and positioning of singlewalled CNTs across these junctions. The use of a haptic force feedback interface to a scanning probe microscope is used to enable movement of nanotubes over micron length scales with nanometer precision. In this case, imaging of the surface is performed with light or intermittent contact to the surface. Increased tip-to-sample interaction forces are then applied to either create junctions or position CNTs. The effect of functionalization of substrate surfaces on the movement and tribology of the materials is also studied. The application of these techniques to the fabrication of CNT-based sensors for nondestructive evaluation applications is discussed.

Wincheski, Buzz↗

Analysis of human postural responses to recoverable falls

We studied the kinematics and kinetics of human postural responses to "recoverable falls." To induce brief falling we used a Hold and Release (H&R) paradigm. Standing subjects actively resisted a force applied to their sternum. When this force was quickly released they were suddenly off balance. For a brief period, approximately 125 ms, until restoring forces were generated to shift the center of foot pressure in front of the center of mass, the body was in a forward fall acted on by gravity and ground support forces. We were able to describe the whole-body postural behavior following release using a multilink inverted pendulum model in a regime of "small oscillations." A three-segment model incorporating upper body, upper leg, and lower leg, with active stiffness and damping at the joints was fully adequate to fit the kinematic data from all conditions. The significance of our findings is that in situations involving recoverable falls or loss of balance the earliest responses are likely dependent on actively-tuned, reflexive mechanisms yielding stiffness and damping modulation of the joints. We demonstrate that haptic cues from index fingertip contact with a stationary surface lead to a significantly smaller angular displacement of the torso and a more rapid recovery of balance. Our H&R paradigm and associated model provide a quantifiable approach to studying recovery from potential falling in normal and clinical subjects.

NASA Discipline Space Human Factors↗

Two memories for geographical slant: separation and interdependence of action and awareness

The present study extended previous findings of geographical slant perception, in which verbal judgments of the incline of hills were greatly overestimated but motoric (haptic) adjustments were much more accurate. In judging slant from memory following a brief or extended time delay, subjects' verbal judgments were greater than those given when viewing hills. Motoric estimates differed depending on the length of the delay and place of response. With a short delay, motoric adjustments made in the proximity of the hill did not differ from those evoked during perception. When given a longer delay or when taken away from the hill, subjects' motoric responses increased along with the increase in verbal reports. These results suggest two different memorial influences on action. With a short delay at the hill, memory for visual guidance is separate from the explicit memory informing the conscious response. With short or long delays away from the hill, short-term visual guidance memory no longer persists, and both motor and verbal responses are driven by an explicit representation. These results support recent research involving visual guidance from memory, where actions become influenced by conscious awareness, and provide evidence for communication between the "what" and "how" visual processing systems.

NASA Discipline Space Human Factors↗

Congenitally blind individuals rapidly adapt to coriolis force perturbations of their reaching movements

Reaching movements made to visual targets in a rotating room are initially deviated in path and endpoint in the direction of transient Coriolis forces generated by the motion of the arm relative to the rotating environment. With additional reaches, movements become progressively straighter and more accurate. Such adaptation can occur even in the absence of visual feedback about movement progression or terminus. Here we examined whether congenitally blind and sighted subjects without visual feedback would demonstrate adaptation to Coriolis forces when they pointed to a haptically specified target location. Subjects were tested pre-, per-, and postrotation at 10 rpm counterclockwise. Reaching to straight ahead targets prerotation, both groups exhibited slightly curved paths. Per-rotation, both groups showed large initial deviations of movement path and curvature but within 12 reaches on average had returned to prerotation curvature levels and endpoints. Postrotation, both groups showed mirror image patterns of curvature and endpoint to the per-rotation pattern. The groups did not differ significantly on any of the performance measures. These results provide compelling evidence that motor adaptation to Coriolis perturbations can be achieved on the basis of proprioceptive, somatosensory, and motor information in the complete absence of visual experience.

NASA Discipline Neuroscience↗