INVESTIGATION OF HEAT TRANSFER AT HIGH HEAT FLUX- EXPERIMENTAL STUDY OF HEAT TRANSFER AND FRICTION DROP WITH N-BUTYL ALCOHOL IN AN ELECTRICALLY HEATED TUBE
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Present study examines the numerical analysis of MHD flow of Maxwell fluid with thermal radiation and Joule heating by considering the recently developed Cattaneo-Christov heat flux model which explains the time relaxation characteristics for the heat flux. The objective is to analyze the governing parameters such as viscoelastic fluid parameter, Magnetic parameter, Eckert and Prandtl number’s impact on the velocity and temperature profiles through graphs and tables. Suitable similarity transformations have been used to reduce the formulated PDEs into a system of coupled non-linear ODEs. Shooting technique has been invoked for finding the numerical solutions of the dimensionless velocity and temperature profiles. Additionally, the MATLAB built-in routine bvp4c has also been used to verify and strengthen the results obtained by shooting method. From some special cases of the present work, a comparison with the previously published results has been presented.
Abstract There are no direct methods to evaluate calculated soil heat flux (SHF) at the surface ( G 0 ). Instead, validation and cross evaluation of methods for calculating G 0 usually rely on the conventional calorimetric method or the degree of the surface energy balance closure. However, there is uncertainty in the calorimetric method itself, and factors apart from G 0 also contribute to nonclosure of the surface energy balance. Here we used a novel approach to evaluate nine different methods for calculating SHF, including the calorimetric method and methods based on analytical solutions of the heat diffusion equation. The SHF ( G z ) measured by a self‐calibrating SHF plate at a depth of z = 5 cm below the surface (hereafter G m _5 cm ) was deployed as a reference. Each SHF calculation method was assessed by comparing the calculated G z at the same depth (hereafter G c _5 cm ) with G m _5 cm . The calorimetric method and simple measurement method performed best in determining G c _5 cm but still underestimated G m _5 cm by 19% during the daytime. Possible causes for this underestimation include errors and uncertainties in SHF measurements and soil thermal properties, as well as the phase lag between G c _5 cm and G m _5 cm . Our results indicate that the calorimetric method achieves the most accurate SHF estimates if self‐calibrating SHF plates are deployed at two depths (e.g., 5 cm and 10 cm), soil temperature and water content measurements are made in a few depths between the two plates, and soil thermal properties are accurately quantified.
A numerical analysis is presented for the overall performance of heat pipes with single or multiple heat sources. The analysis includes the heat conduction in the wall and liquid-wick regions as well as the compressibility effect of the vapor inside the heat pipe. The two-dimensional elliptic governing equations in conjunction with the thermodynamic equilibrium relation and appropriate boundary conditions are solved numerically. The solutions are in agreement with existing experimental data for the vapor and wall temperatures at both low and high operating temperatures.
The primary objective of the Phase Change HX payload on the International Space Station (ISS) is to test and demonstrate the viability and performance of Phase Change Material Heat Exchangers (PCM HX). The system was required to pump a working fluid through a PCM HX to promote the phase change material to freeze and thaw as expected on Orion's Multipurpose Crew Vehicle. Due to limitations on ISS's Internal Thermal Control System, a heat pump was needed on the Phase Change HX payload to help with reducing the working fluid's temperature to below 0degC (32degF). This paper will review the design and development of a TEC based liquid-liquid heat exchanger as a way to vary to fluid temperature for the freeze and thaw phase of the PCM HX. Specifically, the paper will review the design of custom coldplates and sizing for the required heat removal of the HX.
The results of numerical research on the determination of the temperature value of the internal surface of the heat-removing channel (HRC) walls of the light-absorbing heat-exchange panels (LAHPs) with the tubeon- sheet and thin-parallelepiped form of flat-plate solar water-heating collectors (FPSWHCs) are presented. The research method is based on compilation of the system of the balance equations for the light-absorbing plate (LAP) and HRCs of the LAHPs of the studied types and their designs with respect to the desired parameter. A practical example of calculation of the determination of the temperature value of the internal surface of the HRC wall of the tube-on-sheet LAHP, where the results of experimental research on the determination of the specific thermal efficiency of the mean-quality FPSWHC in full-scale terms, as well as laboratory and numerical research on determination of the optical and thermotechnical indicators of the copper tube-on-sheet LAHP.
The purpose of this playbook and accompanying spreadsheets is to generalize the detailed CBP analysis and to put tools in the hands of experienced refrigeration designers to evaluate multiple applications of refrigeration waste heat reclaim across the United States. Supermarkets with large portfolios of similar buildings can use these tools to assess the impact of large-scale implementation of heat reclaim systems. In addition, the playbook provides best practices for implementing heat reclaim systems to achieve the best long-term performance possible. It includes guidance on operations and maintenance as well as measurement and verification.
Forced convection heat transfer for liquid metal flow in rectangular channels with prescribed wall heat fluxes and heat sources in fluid stream
Nanocomposite materials consisting of small crystalline grains embedded within an amorphous matrix show promise for many soft magnetic applications. The influence of pressure is investigated by in situ diffraction of hammer milled Fe{sub 89}Zr{sub 7}B{sub 4} during heating through the {alpha}{yields}{gamma} Fe transition at 0.5, 2.2, and 4.9 GPa. The changes in primary and secondary crystallization onset are described by diffusion and the energy to form a critical nucleus within the framework of classical nucleation theory.
Cycloheptatrienyl (tropyl) radical, C{sub 7}H{sub 7}, was cleanly produced in the gas-phase, entrained in He or Ne carrier gas, and subjected to a set of flash-pyrolysis micro-reactors. The pyrolysis products resulting from C{sub 7}H{sub 7} were detected and identified by vacuum ultraviolet photoionization mass spectrometry. Complementary product identification was provided by infrared absorption spectroscopy. Pyrolysis pressures in the micro-reactor were roughly 200 Torr and residence times were approximately 100 μs. Thermal cracking of tropyl radical begins at 1100 K and the products from pyrolysis of C{sub 7}H{sub 7} are only acetylene and cyclopentadienyl radicals. Tropyl radicals do not isomerize to benzyl radicals at reactor temperatures up to 1600 K. Heating samples of either cycloheptatriene or norbornadiene never produced tropyl (C{sub 7}H{sub 7}) radicals but rather only benzyl (C{sub 6}H{sub 5}CH{sub 2}). The thermal decomposition of benzyl radicals has been reconsidered without participation of tropyl radicals. There are at least three distinct pathways for pyrolysis of benzyl radical: the Benson fragmentation, the methyl-phenyl radical, and the bridgehead norbornadienyl radical. These three pathways account for the majority of the products detected following pyrolysis of all of the isotopomers: C{sub 6}H{sub 5}CH{sub 2}, C{sub 6}H{sub 5}CD{sub 2}, C{sub 6}D{sub 5}CH{sub 2}, and C{sub 6}H{sub 5}{sup 13}CH{sub 2}. Analysis of the temperature dependence for the pyrolysis of the isotopic species (C{sub 6}H{sub 5}CD{sub 2}, C{sub 6}D{sub 5}CH{sub 2}, and C{sub 6}H{sub 5}{sup 13}CH{sub 2}) suggests the Benson fragmentation and the norbornadienyl pathways open at reactor temperatures of 1300 K while the methyl-phenyl radical channel becomes active at slightly higher temperatures (1500 K).
Four types of heat flux gages (Gardon, Schmidt-Boelter, Directional Flame Temperature, and High Temperature Heat Flux Sensor) were assessed and compared under flux conditions ranging between 100-1000 kW/m2, such as those seen in hydrocarbon fire or propellant fire conditions. Short duration step and pulse boundary conditions were imposed using a six-panel cylindrical array of high-temperature tungsten lamps. Overall, agreement between all gages was acceptable for the pulse tests and also for the step tests. However, repeated tests with the HTHFS with relatively long durations at temperatures approaching 1000ÀC showed a substantial decrease (10-25%) in heat flux subsequent to the initial test, likely due to the mounting technique. New HTHFS gages have been ordered to allow additional tests to determine the cause of the flux reduction.
Time averaged Stanton number and surface-pressure distributions are reported for the first-stage vane row, the first stage blade row, and the second stage vane row of the Rocketdyne Space Shuttle Main Engine two-stage fuel-side turbine. Unsteady pressure envelope measurements for the first blade are also reported. These measurements were made at 10 percent, 50 percent, and 90 percent span on both the pressure and suction surfaces of the first stage components. Additional Stanton number measurements were made on the first stage blade platform blade tip, and shroud, and at 50 percent span on the second vane. A shock tube was used as a short duration source of heated and pressurized air to which the turbine was subjected. Platinum thin-film heat flux gages were used to obtain the heat flux measurements, while miniature silicon-diaphragm flush-mounted pressure transducers were used to obtain the pressure measurements. The first stage vane Stanton number distributions are compared with predictions obtained using a version of STAN5 and a quasi-3D Navier-Stokes solution. This same quasi-3D N-S code was also used to obtain predictions for the first blade and the second vane.
A novel approach for the study of parallel transport in magnetized plasmas is presented. The method avoids numerical pollution issues of grid-based formulations and applies to integrable and chaotic magnetic fields with local or nonlocal parallel closures. In weakly chaotic fields, the method gives the fractal structure of the devil's staircase radial temperature profile. In fully chaotic fields, the temperature exhibits self-similar spatiotemporal evolution with a stretched-exponential scaling function for local closures and an algebraically decaying one for nonlocal closures. It is shown that, for both closures, the effective radial heat transport is incompatible with the quasilinear diffusion model.
Forced-convection heat transfer analysis for liquid metal flow in rectangular channels with heat source within fluid stream
Abstract not provided
Internal heat source effect on heat transfer for turbulent liquid metal flow between parallel plates