Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effects of Heat Treatment on Microstructure, Thermal Transport and Stability in SRF Niobium

Efficient heat transfer and thermal stability are critical for preventing thermal quench and ensuring the high performance and reliability of superconducting radiofrequency (SRF) cavities, especially under high RF fields. In this article, we investigate thermal conductivity and heat capacity of high-purity cold-worked niobium used in SRF applications, with a particular focus on the effects of high-temperature heat treatments. Our measurements reveal a pronounced sensitivity of thermal transport and thermodynamic properties to the underlying microstructure such as grain size and dislocation density. The results show the critical role of controlled heat treatment processes in optimizing the thermal performance of SRF niobium, providing valuable insights for improving cavity fabrication and processing.

36 MATERIALS SCIENCE↗

Dual-Functional Thermocapacitive Heat Pump with Electrochemical Supercapacitors for Building Thermal Management and Energy Storage

Efficient heating and cooling technologies can help reduce the energy consumption and carbon emissions of buildings. This work explores the use of supercapacitive cells in a multifunctional, liquid-regenerated thermocapacitive heat pump that can provide electrical energy storage in addition to heating and cooling. A proof-of-concept prototype based on eight commercial supercapacitors and using deionized water as a liquid regenerator demonstrated cooling and energy storage capabilities. A peak cooling coefficient of performance (COPc) of 0.27 was achieved at a temperature drop of 0.24 K. The highest measured electrical energy storage density of the cells was 5.93 J cm-3, and the highest cooling power delivered relative to the volume of the cells was 0.58 mW cm-3. This work demonstrates the use of electrochemical energy storage devices in multifunctional equipment for thermal management in buildings.

25 ENERGY STORAGE↗

A two-phase three-field modeling framework for heat pipe application in nuclear reactors

Heat pipes and two-phase thermosyphons are highly efficient heat transfer devices utilizing continuous evaporation and condensation of working fluid for two-phase heat transport in closed systems. Because of the nearly isothermal and fully passive phase-change heat transfer mechanism, heat pipes and thermosyphons have found many applications in nuclear engineering, space technologies, and other energy systems. High-temperature heat pipes are used in nuclear microreactors to remove fission power from the primary system and are coupled with power conversion systems or process heat applications. Modeling of the two-phase flow phenomena inside a heat pipe is essential to its design and safety analysis. In this study, a comprehensive one-dimensional two-phase three-field flow model has been developed for the analysis of heat pipes in normal operation conditions and transients. The conservation or field equations of mass, momentum, and energy were developed for the liquid film, vapor, and droplet. In addition, constitutive models or correlations were reviewed thoroughly and provided for the closure of the three-field equations. Specific constitutive equations regarding interfacial mass and heat transfer at two interfaces, namely film-gas interface and gas-droplet interface, were reviewed for droplet entrainment and deposition rates as well as film and droplet evaporation rates. Furthermore, mechanistic correlations of annular flow film thickness were recommended for the modeling of the thermosyphons without a wick as a critical constitutive correlation. Furthermore, experimental data needs from new experiments using a prototype working fluid or surrogate fluids for the model validation of high-temperature heat pipes in microreactors were recommended for future research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ammonia-based chemisorption heat pumps for cold-climate heating applications: A comprehensive review

This paper reviews the state of the art of chemisorption heat pumps that use ammonia as the refrigerant for cold-climate heating applications. In such a system, ammonia vapor is adsorbed by the solid salt through reversible chemisorption reactions, and the thermal effect of the reaction and ammonia phase change is used to extract heat from a cold environment and supply heat to a warm environment. With the high latent heat and low boiling point of ammonia as a low-temperature refrigerant and the high sorption capacity of ammonia-based chemisorption reactions, chemisorption heat pumps have the potential to produce high-efficiency heating, particularly for cold climates. This review first briefly introduces the basics of ammonia-based chemisorption heat pump systems. Then, the latest development of sorbent materials, including ammoniate salts and heat-conductive porous matrix materials, are summarized with the focus on low-temperature heating conditions. The design of system components, as well as cycle configurations, in the literature are summarized. This review concludes with highlights of recent developments on these topics and suggestions of areas for further research.

42 ENGINEERING↗

Optimizing flow condensation models for next-generation refrigerants in axial micro-fin aluminum tubes

To support the transition to next-generation refrigerants, accurate modelling of heat transfer and pressure drop is essential for designing efficient heat exchangers. Current models, largely based on traditional refrigerants and unexpanded micro-fin tubes, may not reliably predict performance for new refrigerants and expanded micro-fin geometries. This study evaluates four condensation models using experimental data for six A2L refrigerants: R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E). For heat transfer models, the Han and Lee (2005) model initially yields the best accuracy (mean absolute Deviation, MAD = 22.1%). To further improve predictions, a correction factor reduces the Cavallini et al. (2009) model’s MAD from 68.2% to 15.4%, while optimization of the Kedzierski and Goncalves (1997) model achieves a MAD of 13.1%. For pressure drop, the Cavallini et al. (1997) model proves most accurate (MAD = 6.4%), with the simpler Haraguchi et al. (1993) model also effective (MAD = 9.4%). Keywords: Flow condensation models, heat transfer coefficient, frictional pressure drop, next-generation refrigerants, aluminum micro-fin tubes

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Sockeye Code Validation Against UNIST Heat Pipe - Poster - Internship 2025

Sockeye is an engineering level code being developed under the MOOSE framework for modeling heat pipes. A heat pipe is a sealed tube with a wick structure filled with a working fluid that transfers heat efficiently and passively via phase change of the working fluid. Heat applied to the evaporator end creates a pressure gradient which causes vapor to migrate to the condenser end where the vapor deposits its energy and condenses. Capillary force generated by the wick structure then draws the liquid back to the evaporator. A validation study was performed to compare the Sockeye code against data produced at the Ulsan National Institute of Standards and Technology for a slightly overfilled sodium heat pipe. The heat pipe was operated under natural convection cooling and a decreasing inactive length was observed. The experiment was modeled in Sockeye using the condenser pool model, the front non-condensable gas (NCG) model, and the mixture NCG model separately to reproduce the inactive length phenomenon. Also, a new capability was implemented in MOOSE to allow for conjugate heat transfer from the condenser based on the Churchill-Chu correlation for natural convection. The condenser pool model showed an increasing inactive length, demonstrating that the behavior was likely not caused by a pool of excess liquid. The front NCG model was able to show good agreement with the experiment, but it suffered convergence issues at the front. Finally, the mixture NCG model gave good results when the axial mesh was sufficiently refined. This work culminated in additions to the Sockeye documentation and a contribution to a journal article that will be published later. This poster is a summary of my work which I can take back to my university for presentation.

42 - ENGINEERING↗

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes↗

Grid-connected heat pump water heater benefits for low-income households in the Southeastern United States

Energy efficient heat pump water heaters (HPWHs) reduce customer energy costs; grid-connected controls further increase HPWH value by enabling energy storage and shifting demand to cheaper, off-peak periods. However, a HPWH’s first cost premium can put it out of reach for low-income customers. This paper will present results of an ongoing study exploring the benefits of load shifting HPWHs for 24 low-income households, aiming to support increased product deployment in this demographic. The study uses EcoPort modules to shift HPWH load for a study sample consisting primarily of low-income adults and seniors in North Carolina. Building upon prior studies, the study’s HPWH operating schedules are designed to maximize shifted energy and minimize participant electricity costs based on local time-of-use rates. The study documents load profiles of grid-connected HPWHs in a less-studied demographic group and explores how certain groups may have particularly flexible loads due to their unique usage profiles. The results are relevant for HPWH product performance in the Southeast. The study will quantify HPWH load shifting performance during North Carolina’s hot summer, temperate shoulder, and occasionally sub-freezing winter seasons, and the study includes installations in conditioned, semi-conditioned, and unconditioned spaces. Finally, study results will also explore how controlled HPWHs can provide value to the regional grid by reducing seasonal peaks via demand response. Lessons learned include HPWH acceptance for low-income and senior users, best practices for maintaining HPWH connectivity among users without prior product experience, and strategies to leverage remote monitoring to ensure optimal operation and enhance HPWH reliability.

Urigwe, Daniela↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Mitigation of ICRF—edge plasma interaction in Alcator C-Mod

The parasitic interaction between ion cyclotron range of frequencies (ICRF) waves and the edge plasma has long limited high-power ICRF utilization in magnetically confined fusion plasmas. In this paper, we report on the successful mitigation of this interaction by power tapering a four-strap field-aligned (FA) antenna in the Alcator C-Mod tokamak. With the antenna operated in dipole phasing ($0\pi0\pi$), the ratio of the power coupled by the central two straps ($P_\mathrm {cent}$) to the power coupled by the outer two straps was varied at fixed total coupled ICRF power ($P_\mathrm {tot}$). With $P_\mathrm {cent}$/$P_\mathrm {tot} \approx 0.8-0.9$, no enhancement of the plasma potential was measured despite 1 MW of coupled ICRF power. When the antenna is powered, energy deposition increases on its four corners and on neighboring limiter tiles magnetically connected to some of those corners. The energy deposited on the antenna and limiter is minimized together with near-field plasma potentials. Additionally, we show that deviation from $P_\mathrm {cent}$/$P_\mathrm {tot} \approx 0.8$ enhances wave-plasma interactions in places not magnetically connected to the antenna. These far-field effects are correlated with changes in the antenna spectrum. Hence, on C-Mod, near-field and far-field interactions were minimized for about the same range of $P_\mathrm {cent}$/$P_\mathrm {tot}$. Optimal power tapering was also found to improve ICRF heating efficiency and facilitate H-mode access. Finally, we show that the heat flux pattern on the toroidally aligned antennas reverses with the direction of the RF-induced E×B flow in front of the antenna, a correlation not observed for the FA antenna. We argue that the RF-induced E×B flow, which carries high-density plasma from the near-SOL, is aligned with the FA antenna and does not intercept its corners, where the plasma potential is large. This could explain the previously reported smaller impurity generation by the FA antenna (Wukitch et al 2013 Phys. Plasmas 20 056117).

Alcator C-Mod↗

Evaluation of Energy Efficiency Performance of Heated Windows

Fenestration systems are widely used across the world. There is expansive research on window configurations, frames, and glazing technology, but not enough research has been published on reducing window heat loss through heat application to a pane. The presented study attempted to evaluate the performance of heated windows by developing an experimental setup to test a window at various temperatures by varying the power input to the window. Heated double pane window was installed in an insulated box. A temperature gradient was developed across the window by cooling one side of the window using gel-based ice packs. The other face of the window was heated by enabling power at different wattages through the window. The temperature of the inside and outside panes, current and voltage input, and temperature of the room and box were recorded. The data was used to calculate the apparent effective resistance of the window when not being heated vs. when being heated. The study concluded that, when window temperature was maintained close to the room temperature, the heated double pane window is effective in reducing heat loss by as much as 50% as compared to a non-heated double pane window. When temperature of the window was much higher than the room temperature, the heat loss through the window increased beyond that of a non-heated window. The issues encountered during the current stages of experiments are noted, and recommendations are provided for future studies.

42 ENGINEERING↗

A novel lung-inspired 3D-printed desiccant-coated heat exchanger for high-performance humidity management in buildings

Offering an independent humidity management method for buildings, desiccant-coated heat exchangers (DCHXs) are deemed a promising approach to improve the overall energy efficiency of air conditioning (AC) systems. State-of-the-art DCHXs, however, are bound with conventional HX topologies either providing limited desiccant-air interfacial areas or introducing excessive pressure drop penalties. In this paper a novel 3D-printed DCHX concept inspired by the bronchi arrangement of a human lung is introduced to address the shortcomings inherent in existing DCHX designs. The proposed lung-inspired DCHX utilizes two intertwined bicontinuous flow networks enabling highly efficient heat and mass transfer characteristics for augmented adsorption and regeneration processes at low pressure drop penalties. While the first network evenly distributes an incoming air stream through the entire volume of the lung-inspired DCHX, the second network volumetrically splits a cooling water stream within and through the first network. Effects of various parameters including air flow rate, outdoor air humidity ratio, and regeneration temperature on dehumidification performance and energy efficiency of the proposed lung-inspired DCHX were investigated. Experimental results indicated the proposed lung-inspired 3D-printed DCHX outperforms existing DCHX systems by demonstrating an excellent balance between a high volumetric adsorption rate and a low pressure drop penalty. The volumetric adsorption rate of the proposed lung-inspired DCHX technology is 54.8 g/m 3 -s, a more than two-fold improvement compared with state-of-the-art DCHX systems. Additionally, the lung-inspired DCHX offers high thermal energy efficiency of 56% at a low regeneration temperature of 40 °C. Therefore, the proposed lung-inspired 3D-printed DCHX offers a new solid-desiccant-based air dehumidification pathway for next-generation high-performance AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage in Crystalline Rock Formations (DEMO-FTES) [Abstract]

Approximately half of global energy consumption is used for heating and cooling. Because fossil fuels are used to meet most of this demand, heating and cooling of buildings produces a large portion of global greenhouse gas (GHG) emissions. The proposed project seeks to demonstrate the feasibility of a seasonal thermal energy storage concept called fracture thermal energy storage (FTES), which has the potential to dramatically lower energy requirements for heating and cooling and improve the resilience of building energy systems. FTES is a technique for building a highly efficient heat exchanger by creating a carefully designed set of fractures in the ground below a building. This heat exchanger allows thermal energy to be stored over seasonal timeframes—for example, hot thermal energy that is easily captured in the summer or energy from waste heat sources—to meet heating needs during colder months. FTES offers a solution with a relatively small footprint and lower cost compared to currently operating aquifer thermal energy storage (ATES) systems and could be used in the many areas without aquifers suitable for ATES. If commercialized, FTES systems could exceed the 2.5 TWh of energy storage per year from the more than 2,800 ATES systems in operation worldwide, which range from 0.1 MW to 30 MW. The savings in CO2 emissions per year are also expected to match or exceed individual ATES projects, with the largest, a 30 MW system used to provide heating and cooling to the University of Technology in Eindhoven in the Netherlands, estimated to save 13,000 tons of CO2 emissions per year. FTES utilizes mature drilling and fracturing technology and therefore has the potential to be rapidly commercialized once demonstrated. The ability to construct and establish flow through an FTES heat exchanger has been demonstrated by a previous project and the potential for efficient, large-capacity energy storage has been shown using numerical models. However, no experimental validation of these numerical estimates of thermal energy storage has been made. The first crucial need to advance FTES technology is to identify the sensitivity of key metrics such as thermal energy storage and production rates, capacities, and efficiencies to design parameters such as the number of fractures, depth/temperature of fractures, size of fractures, and circulation rates. The second crucial need is experimental testing of achievable thermal performance with optimized system design parameters. The proposed scope of work seeks to systematically address these two critical needs through a highly complementary international collaboration spanning theory, laboratory, and mesoscale field evaluation. The proposed work plan calls for using dimensional analysis and existing state-of-the-art numerical simulators to design carefully scaled laboratory and 10-meter-scale field tests of the thermal efficiency of FTES. The existing advanced laboratory and intermediate-scale field testbeds that will be used for this project will allow for detailed monitoring of the system performance during the test and of how the performance changes across time and length scales. These results will determine the feasibility of full- scale FTES systems. If the thermal performance is consistent with model predictions, the results will provide a strong economic justification for rapid commercialization of FTES technology in a wide range of geographical areas.

25 ENERGY STORAGE↗

Calculation of Friction Factors in Heat Pipes Using CFD in Support of the Sockeye Code

A heat pipe is two-phase heat transfer device which relies on surface tension and capillary pressure to provide a very efficient heat transfer mechanism. Currently, there is interest in designing micro nuclear power reactors using high temperature heat pipes to provide totally passive cooling. To support this, Sockeye is being developed as a heat pipe simulation capability. To support the development of Sockeye, individual phenomena must be tested. This work focuses on applying a CFD model to evaluate friction factors for use in Sockeye. A CFD model has been developed in Nek5000 which simulates each component fluid, i.e. sodium liquid and vapor, independently and captures the effects of the wick on friction factor. The model tests the effect of the wick permeability and the thickness of the wick occupied by each fluid component. The thickness of the wick occupied by each component can be directly related to the local vapor volume fraction from the Sockeye heat pipe model. Results from the CFD model indicate that friction factor in the liquid flow decreases with increasing wick permeability, while the friction factor in the vapor flow increases with increasing wick permeability. In the liquid, this is likely a direct result of the increased cross sectional area available for the flow. For the vapor, this is explained as the wick acting like a rough wall, while the increased area has only a negligible impact. Results for the tests of the thickness of the wick occupied by each fluid showed a thresholding behavior for both liquid and vapor. When the thickness of the wick occupied by each fluid was increased, it increased the effect of the wick, but only up to a certain point. Once a certain thickness was reached, the friction factors remained constant. When the fluid occupied only a very small fraction of the wick, friction factors returned to nominal values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Time-Resolved Structural Measurement of Thermal Resistance across a Buried Semiconductor Heterostructure Interface

The precise control and understanding of heat flow in heterostructures is pivotal for advancements in thermoelectric energy conversion, thermal barrier coatings, and efficient heat management in electronic and optoelectronic devices. In this study, we employ high-angular-resolution time-resolved X-ray diffraction to structurally measure thermal resistance in a laser-excited AlGaAs/GaAs semiconductor heterostructure. Our methodology offers femtometer-scale spatial sensitivity and nanosecond time resolution, enabling us to directly observe heat transport across a buried interface. We corroborate established Thermal Boundary Resistance (TBR) values for AlGaAs/GaAs heterostructures and demonstrate that TBR arises from material property discrepancies on either side of a nearly flawless atomic interface. This work not only sheds light on the fundamental mechanisms governing heat flow across buried interfaces but also presents a robust experimental framework that can be extended to other heterostructure systems, paving the way for optimized thermal management in next-generation devices.

36 MATERIALS SCIENCE↗

Electric charging particle heater for thermal energy storage

The disclosure relates to particle heaters for heating solid particles to store electrical energy as thermal energy. Thermal energy storage directly converts off-peak electricity into heat for thermal energy storage, which may be converted back to electricity, for example during peak-hour power generation. The particle heater is an integral part of an electro-thermal energy storage system, as it enables the conversion of electrical energy into thermal energy. As described herein, particle heater designs are described that provide efficient heating of solid particles in an efficient and compact configuration to achieve high energy density and low cost.

Ma, Zhiwen↗