Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hemodynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Acute Hemodynamic Effects of the Braslet-M Device on the International Space Station

The Braslet-M occlusion device is prescribed for cosmonauts as a countermeasure for early phases of spaceflight to temporarily alleviate symptoms associated with the cephalad fluid shift. Using a multipurpose ultrasound (US) device onboard, we assessed the acute hemodynamic effects of the Bracelet-M device on a long duration International Space Station (ISS) crewmember. Methods A combination of just-in-time training and real-time remote expert assistance was used to conduct the imaging procedures. An HDI-5000 imager (Philips, Bothell, WA) was used, provided by the ISS Human Research Facility. Superficial femoral artery (SFA), femoral vein (FV) flow spectra were obtained at mid-thigh level. Left ventricle was imaged through the apical 4-chamber view, with Color M-Mode to measure propagation velocity (V (p)). After 10 minutes of Bracelet-M use, data collection was repeated. All data were transmitted in DICOM format to ground for analysis. Results With Braslet-M, cardiac V(p) slope decreased (56ms to 42ms). A stagnation signature in the FV was seen suggesting impeded flow (rouleaux formation, too-low-to-measure velocity, and increase in diameter). Quadri-phasic flow in SFA was seen both before and after Braslet-M application. Velocities in the SFA decreased with Braslet-M (65cm/sec to 52cm/sec) and so did the time velocity integrals (16.97 to 12.4); the flow pattern spoke of resistivity increase in the vascular bed. Conclusion In the long duration ISS crewmember we observed effects of lower extremity venous occlusion through both central and peripheral indicators. A part of circulating volume transferred to peripheral potential vascular space. Impediment to venous outflow was demonstrated objectively, with a commensurate change in the flow pattern of the main feeding artery. Central volume reduction caused lower V(p). Additional studies are warranted to determine the time course of the changes and the dynamics in interstitial fluid sequestration, as well as the safe levels and duration of the compression forces.

Hamilton, Douglas R.↗

Influence of Exercise Modality on Cerebral-Ocular Hemodynamics and Pressures

Background: Moderate and high intensity aerobic or resistance exercise has clearly identified benefits for cardiac, muscle, and bone health. However, the impact of such exercise - either as a mitigating or an exacerbating factor - on the development of the visual impairment and intracranial pressure syndrome (VIIP) is unknown. Accordingly, our aim was to characterize the effect of an acute bout of resistance (RE), moderate-intensity continuous (CE), and high-intensity interval exercise (IE) during a cephalad fluid shift on cerebral-ocular hemodynamics and pressures. Methods: 10 male subjects (36 plus or minus 9 years) completed 4 testing days in a 15 degree head-down tilt (HDT): (1) assessment of maximum volume of O (sub 2), (2) RE session (4 sets of 12 repetition maximum leg press exercise), (3) CE session (30 minutes of cycling at 60 percent maximum volume of O (sub 2)), and (4) IE session (4 by 4-minute intervals of exercise at 85 percent maximum volume of O (sub 2) with 3-minute active rest periods). During each session, blood flow (Vivid-e, GE Healthcare) in extracranial arteries (common carotid artery, CCA; internal carotid artery, ICA; external carotid artery, ECA and vertebral artery, VA), and mean blood flow velocity in middle cerebral artery (MCA), internal jugular pressure (IJP; VeinPress), and intraocular pressure (IOP; Icare PRO) were measured at rest, at the end of each resistance or interval set, and every 5 minutes during continuous exercise. Translaminar pressure gradient (TLPG) was estimated by subtracting IJP from IOP. Results: There were no differences across days in pre-exercise resting blood flows or pressures. IOP decreased slightly from HDT rest (20.2 plus or minus 2.3 millimeters of mercury) to exercise (RE: 19.2 plus or minus 2.8 millimeters of mercury; CE: 18.9 plus or minus 3.2 millimeters of mercury; IE: 20.1 plus or minus 2.8 millimeters of mercury), while IJP decreased during CE (31.6 plus or minus 9.5 millimeters of mercury) and RE (32.0 plus or minus 8.1 millimeters of mercury), and increased during IE (35.1 plus or minus 9.5 millimeters of mercury) from HDT rest (33.3 plus or minus 6.5 millimeters of mercury). Estimated TLPG was increased during IE only. Compared to RE and CE, IE resulted in the greatest increase in MCA blood flow velocity and extracranial artery blood flow. Conclusions: These preliminary results suggest that high-intensity IE acutely increases cerebral blood flow, IJP, and TLPG. Alterations in TLPG is one mechanism that may contribute to optic nerve sheath edema in astronauts. Accordingly, acutely raising IOP and/or orbital pressure during exercise could optimize cerebral-ocular pressures during spaceflight.

Scott, J.↗

Gender differences in autonomic cardiovascular regulation: spectral, hormonal, and hemodynamic indexes

The autonomic nervous system drives variability in heart rate, vascular tone, cardiac ejection, and arterial pressure, but gender differences in autonomic regulation of the latter three parameters are not well documented. In addition to mean values, we used spectral analysis to calculate variability in arterial pressure, heart rate (R-R interval, RRI), stroke volume, and total peripheral resistance (TPR) and measured circulating levels of catecholamines and pancreatic polypeptide in two groups of 25 +/- 1.2-yr-old, healthy men and healthy follicular-phase women (40 total subjects, 10 men and 10 women per group). Group 1 subjects were studied supine, before and after beta- and muscarinic autonomic blockades, administered singly and together on separate days of study. Group 2 subjects were studied supine and drug free with the additional measurement of skin perfusion. In the unblocked state, we found that circulating levels of epinephrine and total spectral power of stroke volume, TPR, and skin perfusion ranged from two to six times greater in men than in women. The difference (men > women) in spectral power of TPR was maintained after beta- and muscarinic blockades, suggesting that the greater oscillations of vascular resistance in men may be alpha-adrenergically mediated. Men exhibited muscarinic buffering of mean TPR whereas women exhibited beta-adrenergic buffering of mean TPR as well as TPR and heart rate oscillations. Women had a greater distribution of RRI power in the breathing frequency range and a less negative slope of ln RRI power vs. ln frequency, both indicators that parasympathetic stimuli were the dominant influence on women's heart rate variability. The results of our study suggest a predominance of sympathetic vascular regulation in men compared with a dominant parasympathetic influence on heart rate regulation in women.

Non-NASA Center↗

Assessment of the time constant of relaxation: insights from simulations and hemodynamic measurements

The objective of this study was to use high-fidelity animal data and numerical simulations to gain more insight into the reliability of the estimated relaxation constant derived from left ventricular pressure decays, assuming a monoexponential model with either a fixed zero or free moving pressure asymptote. Comparison of the experimental data with the results of the simulations demonstrated a trade off between the fixed zero and the free moving asymptote approach. The latter method more closely fits the pressure curves and has the advantage of producing an extra coefficient with potential diagnostic information. On the other hand, this method suffers from larger standard errors on the estimated coefficients. The method with fixed zero asymptote produces values of the time constant of isovolumetric relaxation (tau) within a narrow confidence interval. However, if the pressure curve is actually decaying to a nonzero pressure asymptote, this method results in an inferior fit of the pressure curve and a biased estimation of tau.

NASA Discipline Cardiopulmonary↗

Effects of forearm bier block with bretylium on the hemodynamic and metabolic responses to handgrip

We tested the hypothesis that a reduction in sympathetic tone to exercising forearm muscle would increase blood flow, reduce muscle acidosis, and attenuate reflex responses. Subjects performed a progressive, four-stage rhythmic handgrip protocol before and after forearm bier block with bretylium as forearm blood flow (Doppler) and metabolic (venous effluent metabolite concentration and (31)P-NMR indexes) and autonomic reflex responses (heart rate, blood pressure, and sympathetic nerve traffic) were measured. Bretylium inhibits the release of norepinephrine at the neurovascular junction. Bier block increased blood flow as well as oxygen consumption in the exercising forearm (P < 0.03 and P < 0.02, respectively). However, despite this increase in flow, venous K(+) release and H(+) release were both increased during exercise (P < 0.002 for both indexes). Additionally, minimal muscle pH measured during the first minute of recovery with NMR was lower after bier block (6.41 +/- 0.08 vs. 6.20 +/- 0.06; P < 0.036, simple effects). Meanwhile, reflex effects were unaffected by the bretylium bier block. The results support the conclusion that sympathetic stimulation to muscle during exercise not only limits muscle blood flow but also appears to limit anaerobiosis and H(+) release, presumably through a preferential recruitment of oxidative fibers.

Non-NASA Center↗

Hemodynamic and thermal responses to head and neck cooling in men and women

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.

NASA Center ARC↗

Cardiac beta-adrenergic receptors and coronary hemodynamics in the conscious dog during hypoxic hypoxia.

The mechanisms by which acute hypoxia (10% and 5% oxygen) mediates changes in coronary blood flow and cardiac function were investigated in the conscious dog. When the dogs breathed hypoxic gas mixtures through a tracheostomy, both arterial and coronary sinus oxygen tensions were significantly decreased. With 5% oxygen, there were significant increases in heart rate (25%), maximum left ventricular dP/dt (39%), left circumflex coronary artery blood flow (163%), and left ventricular oxygen consumption (52%), which were attenuated by beta-adrenergic blockage with propranolol. When electrical pacing was used to keep the ventricular rate constant during hypoxia, there was no significant difference in coronary blood flow before and after beta blockade. Beta-adrenergic receptor activity in the myocardium participates in the integrated response to hypoxia although it may not cause active vasodilation of the coronary vessels.

Erickson, H. H.↗

Effects of an anti-G suit on the hemodynamic and renal responses to positive /+Gz/ acceleration

The effects of the currently used U.S. Air Force (CSU-12/P) anti-G suit on renal function during positive radial acceleration (+Gz) were assessed in seven normal male subjects in balance on a 200 meq sodium diet. Following suit inflation in the seated position, +2.0 Gz for 30 min resulted in a decrease in the rate of sodium excretion from 125 plus or minus 19 to 60 plus or minus 14 microeq/min, which persisted during a 25-min recovery period. Fractional excretion of sodium also decreased significantly during +Gz. The magnitude of the antinatriuresis was indistinguishable from that observed during +Gz without suit inflation. In contrast to the antinatriuresis observed during centrifugation without suit, however, the antinatriuresis with suit was mediated primarily by an enhanced tubular reabsorption of sodium.

Shubrooks, S. J., Jr.↗

Development of ultrasonic methods for hemodynamic measurements

A transcutanous method to measure instantaneous mean blood flow in peripheral arteries of the human body was defined. Transcutanous and implanted cuff ultrasound velocity measurements were evaluated, and the accuracies of velocity, flow, and diameter measurements were assessed for steady flow. Performance criteria were established for the pulsed Doppler velocity meter (PUDVM), and performance tests were conducted. Several improvements are suggested.

Histand, M. B.↗

Development of ultrasonic methods of hemodynamic measurements

A pulsed ultrasonic Doppler velocity meter which can be used (by modifying transducers) as a flowmeter for blood circulation was experimentally studied. Calculations and profiles of turbulent and laminar flow within blood vessels are shown. Graphs and charts of transducers are included.

Histand, M. B.↗