Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Pacific Coast High-Frequency Radar 2 km

High frequency (HF) radar systems measure the speed and direction of ocean surface currents in near real time provided by Integrated Ocean Observing System (IOOS). The HFR data along the Pacific Coast are at a spatial resolution of 2 km. These data are collected as part of an observational database developed to support the floating offshore wind energy research within the ORACLE project funded by DOE WETO.

17 WIND ENERGY↗

Pacific Coast High Frequency Radar 6 km

High frequency (HF) radar systems measure the speed and direction of ocean surface currents in near real time provided by Integrated Ocean Observing System (IOOS). The HFR data along the Pacific Coast are at a spatial resolution of 6 km. These data are collected as part of an observational database developed to support the floating offshore wind energy research within the ORACLE project funded by DOE WETO.

17 WIND ENERGY↗

Equivalent-circuit consideration of dual-gate MESFETs at high frequency

The simplified high-frequency equivalent circuit of a dual-gate FET is described. It is shown that the input impedance is similar to that of a single-gate FET but the output resistance and capacitance (parallel equivalent circuit) are higher. The output resistance and the transconductance decrease as frequency increases. The unilateral gain of a dual-gate FET rolls off 12 dB/octave.

Kim, B.↗

Spectral representation of high-frequency Space Shuttle data

High frequency Space Shuttle liftoff data are treated by autoregressive (AR) and autoregressive-moving-average (ARMA) digital algorithms. These algorithms provide useful information on the spectral densities of the data. Further, they yield spectral models, which lend themeselves to incorporation into the concept of the random response spectrum. This concept yields a reasonably smooth power spectrum for the design of structural and mechanical systems when the available data bank is limited. Due to the nonstationary of the liftoff event, the pertinent data are split into three slices. Each of the slices is associated with a rather distinguished phase of the liftoff event, in which stationarity can be expected. The presented results are preliminary in nature; they aim to call attention to the availability of the discussed concepts and to the need to augment the Space Shuttle data bank as more flights are completed.

Spanos, P. D.↗

Month-to-Month and Year-to-Year Reproducibility of High Frequency QRS ECG signals

High frequency (HF) electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. We therefore prospectively investigated the reproducibility of the root mean squared (RMS) voltage, kurtosis, and the presence versus absence of reduced amplitude zones (RAzs) in signal averaged 12-lead HF QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of RMS voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of RMS voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. RAzs were also reproducible at a rate of up to 87% and 8 1 %, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead HF QRS electrocardiograms are sufficiently reproducible for clinical use.

Batdorf, Niles↗

High-current, high-frequency capacitors

The NASA Lewis high-current, high-frequency capacitor development program was conducted under a contract with Maxwell Laboratories, Inc., San Diego, California. The program was started to develop power components for space power systems. One of the components lacking was a high-power, high-frequency capacitor. Some of the technology developed in this program may be directly usable in an all-electric airplane. The materials used in the capacitor included the following: the film is polypropylene, the impregnant is monoisopropyl biphenyl, the conductive epoxy is Emerson and Cuming Stycast 2850 KT, the foil is aluminum, the case is stainless steel (304), and the electrode is a modified copper-ceramic.

Renz, D. D.↗

Planck 2018 results: III. High frequency instrument data processing and frequency maps

This paper presents the High Frequency Instrument (HFI) data processing procedures for the Planck 2018 release. Major improvements in mapmaking have been achieved since the previous Planck 2015 release, many of which were used and described already in an intermediate paper dedicated to the Planck polarized data at low multipoles. These improvements enabled the first significant measurement of the reionization optical depth parameter using Planck-HFI data. This paper presents an extensive analysis of systematic effects, including the use of end-to-end simulations to facilitate their removal and characterize the residuals. The polarized data, which presented a number of known problems in the 2015 Planck release, are very significantly improved, especially the leakage from intensity to polarization. Calibration, based on the cosmic microwave background (CMB) dipole, is now extremely accurate and in the frequency range 100-353 GHz reduces intensity-to-polarization leakage caused by calibration mismatch. The Solar dipole direction has been determined in the three lowest HFI frequency channels to within one arc minute, and its amplitude has an absolute uncertainty smaller than 0.35 μK, an accuracy of order 10 -4 . This is a major legacy from the Planck HFI for future CMB experiments. The removal of bandpass leakage has been improved for the main high-frequency foregrounds by extracting the bandpass-mismatch coefficients for each detector as part of the mapmaking process; these values in turn improve the intensity maps. This is a major change in the philosophy of "frequency maps", which are now computed from single detector data, all adjusted to the same average bandpass response for the main foregrounds. End-to-end simulations have been shown to reproduce very well the relative gain calibration of detectors, as well as drifts within a frequency induced by the residuals of the main systematic effect (analogue-to-digital convertor non-linearity residuals). Using these simulations, we have been able to measure and correct the small frequency calibration bias induced by this systematic effect at the 10 -4 level. There is no detectable sign of a residual calibration bias between the first and second acoustic peaks in the CMB channels, at the 10 -3 level.

79 ASTRONOMY AND ASTROPHYSICS↗

An Analysis of the High Frequency Vibrations in Early Thematic Mapper Scenes

The potential effects of high frequency vibrations on the final Thematic Mapper (TM) image are evaluated for 26 scenes. The angular displacements of the TM detectors from their nominal pointing directions as measured by the TM Angular Displacement Sensor (ADS) and the spacecraft Dry Rotor Inertial Reference Unit (DRIRU) give data on the along scan and cross scan high frequency vibrations present in each scan of a scene. These measurements are to find the maximum overlap and underlap between successive scans, and to analyze the spectrum of the high frequency vibrations acting on the detectors. The Fourier spectrum of the along scan and cross scan vibrations for each scene also evaluated. The spectra of the scenes examined indicate that the high frequency vibrations arise primarily from the motion of the TM and MSS mirrors, and that their amplitudes are well within expected ranges.

Kogut, J.↗

High frequency power distribution system

The objective of this project was to provide the technology of high frequency, high power transmission lines to the 100 kW power range at 20 kHz frequency. In addition to the necessary design studies, a 150 m long, 600 V, 60 A transmission line was built, tested and delivered for full vacuum tests. The configuration analysis on five alternative configurations resulted in the final selection of the three parallel Litz straps configuration, which gave a virtually concentric design in the electromagnetic sense. Low inductance, low EMI and flexibility in handling are the key features of this configuration. The final design was made after a parametric study to minimize the losses, weight and inductance. The construction of the cable was completed with no major difficulties. The R,L,C parameters measured on the cable agreed well with the calculated values. The corona tests on insulation samples showed a safety factor of 3.

Patel, Mikund R.↗

Absolute S- and P-plane polarization efficiencies for high frequency holographic gratings in the VUV

High frequency plane gratings (3500 and 3600 gr/mm) have been holographically ruled and blazed for the VUV spectral region. All gratings were coated with 70 nm Al + 25 nm MgF2. Absolute unpolarized and S- and P-plane polarization efficiencies have been measured for the first and second orders in the 120- to 450-nm spectral region at 18.5 and 30 deg angles of deviation. For deep grooves, anomalous features are more pronounced for the P-plane polarization efficiency than for the S-plane polarization efficiency. Holographic gratings can be tailored to produce high polarization or low polarization in the VUV. For comparison, efficiencies and polarization of the best conventional high frequency gratings were also determined. Measurements show that scattered light is significantly lower for holographic gratings in the VUV when compared with the conventional gratings.

Caruso, A. J.↗

Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms

A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present method is the presence versus the absence of reduced-amplitude zones (RAZs). In terms that must be simplified for the sake of brevity, an RAZ comprises several cycles of a high-frequency QRS signal during which the amplitude of the high-frequency oscillation in a portion of the signal is abnormally low (see figure). A given signal sample exhibiting an interval of reduced amplitude may or may not be classified as an RAZ, depending on quantitative criteria regarding peaks and troughs within the reduced-amplitude portion of the high-frequency QRS signal. This analysis is performed in all 12 leads in real time.

Schlegel, Todd T.↗

The use of high frequency infrared radiometry for remote atmospheric probing with high vertical resolution

The necessity of obtaining soundings of temperature and water vapor content of the lower troposphere with sufficient vertical resolution to determine the exchange of heat and moisture between the surface and the atmosphere is discussed. The means for solving the problem will be emission measurements in the high frequency end of the thermal infrared. The means for solving another problem is supplementary scanning with high area resolution.

Kaplan, L. D.↗

Embedded Fiber Bragg Grating (FBG) Sensors Fabricated by Ultrasonic Additive Manufacturing for High-Frequency Dynamic Strain Measurements

This article demonstrates high-frequency dynamic strain measurements using fiber Bragg grating (FBG) sensors embedded in metal parts. Using an ultrasonic additive manufacturing (UAM) process, FBGs inscribed in polyimide coated optical fibers were embedded in aluminum parts. An electromagnetic shaker was used to exert dynamic events on the embedded FBG sensors with frequencies from 1 to 10 kHz. The high-speed interrogation of FBG sensors was accomplished using a tunable vertical-cavity surface-emitting laser (VCSEL) and a high-speed interrogation system sampling at 120 kHz. The strain response measured by the FBG sensors was compared with real-time measurements using a laser velocimeter. A finite-element analysis (FEA) was performed to simulate responses to both static strain and high-frequency dynamic strain. In conclusion, results show that strains as small as 2.5$με$ can be resolved at frequencies up to 10 kHz.

36 MATERIALS SCIENCE↗

Demonstration of An Image Rejection Mixer for High Frequency Applications (26-36 GHz)

A new high frequency image-rejection mixer was successfully tested in a 26-36 GHz band receiver. This paper briefly describes the motivation for implementation of an image rejection mixer in a receiver system, the basic operation of an image rejection mixer, and the development and testing of an image rejection mixer for a high frequency, cryogenic receiver system.

Bankston, Cheryl D.↗

High-frequency wave normals in the solar wind

High-frequency (0.01-0.04 Hz) magnetic fluctuations in 506 ten-minute intervals of contemporaneous Explorer 35 and Apollo 12 measurements made in the solar wind near the morning side of the earth's bow shock show the presence of a large population of disturbances resembling Alfven waves. Each wavefront normal is systematically aligned (median deviation = 35 deg) with the associated ten-minute average of the magnetic field. Because of variability in the direction of this ten-minute average, from one interval to another, the coupled wavefront-normal distribution is nearly isotropic in solar ecliptic coordinates, in contrast with the results of other studies of waves at much lower frequency indicating outward propagation from the sun. Presumably the high frequency waves discussed here are stirred into isotropy (in solar ecliptic coordinates) by following the low frequency fluctuations. As these waves maintain their alignment of wavefront-normal with the field ten-minute average despite the great variation of the field ten-minute average, a strong physical alignment constraint is inferred.

Herbert, F.↗

Sensitivity Studies of Premixed Flame Response to Transverse, High Frequency Disturbances

This study analyzes the response of premixed flames to high frequency transverse acoustic disturbances. A significant body of experiment, modeling and simulation efforts has been performed to understand the response of the spatially integrated heat release of premixed flames to low-frequency disturbances. These studies quantified this sensitivity through the Flame Transfer Function (FTF), as the global heat release is the key quantity influencing thermoacoustic stability for acoustically compact flames. Recent efforts have expanded these models to consider high-frequency acoustic disturbances, and the sensitivity of premixed flames through the Rayleigh integral (RI). The full Rayleigh Integral, as opposed to simply the spatially integrated heat release, must be considered in these cases where the flame is not acoustically compact. Prior modeling studies considered several effects - stability of axisymmetric flames centered in a cylindrical combustion chamber and the effect of flame offset from the combustor axis and the effect of mean flame asymmetries in the flame centered in the combustor. These studies showed that the flame's stability was sensitive to all these parameters, as well as to the transverse mode in question. In this paper, we quantify these different parametric sensitivities of premixed flame stability in the presence of high-frequency transverse acoustic modes - specifically sensitivity to flame length and nozzle location within the acoustic mode shape for 2 different transverse modes. The sensitivity of the RI to these control parameters provides an improved understanding of which flame parameters are critical to improve the overall thermoacoustic stability of the system.

Acharya, Vishal S.↗

Evaluation of a Multi-kw, High Frequency Transformer for Space Applications

Various NASA studies have shown that high power (multi-kW and higher) electrical systems for various aerospace applications favor high frequency distribution systems, due to the improved safety and weight factors associated with those systems. Other favorable characteristics include low EMI, minimal wiring and ease of system parameter sensing and control of a single phase system. In aerospace power systems, as in terrestrial AC distribution systems, transformers are needed to provide voltage changes, isolation and the resetting of ground. Under NASA contract NAS3-21948 a multi-kW high frequency transformer was designed, fabricated and tested by Thermal Technology Lab, Inc. of Buffalo, New York. 'The goals of this program included the determination of the relationships between transformer weight, efficiency and operating frequency; low internal temperatures and reduced specific weight; and the validation of these new design concepts through experimentation and the fabrication and testing of transformers and their insulation systems.' The transformer was delivered to NASA-Lewis, where an evaluation program was conducted in Lewis' High Power High Frequency Component Test Facility. The transformer was tested in both atmosphere and under vacuum conditions. This paper will discuss the design of the transformer, the evaluation program and test results, the failures experienced and conclusions.

Roth, Mary Ellen↗