Search NASA⌕ Search

SEARCH · Search NASA

Results for “High-purity germanium detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Identify and Assess Technical Challenges in Safeguards Measurements of Spent Advanced Reactor Fuels

Advanced reactor (AR) designs use various nuclear fuel types that can be significantly different than conventional light-water reactor (LWR) fuels, including differences in sizes, compositions, and chemical forms (e.g., oxide, carbide, metal). Nearly all the proposed AR fuels use high-assay low-enriched uranium (HALEU), which will have higher enrichments (5–20 wt% 235 U) than LWR fuels (currently limited to <5 wt% 235 U). In advance of the wide use of these new fuel types around the world, international safeguards organizations such as the International Atomic Energy Agency (IAEA]) are working with some of the AR vendors to formulate safeguards approaches for these AR fuel cycles. As part of the overall safeguards approach, it is important to identify the potential technical challenges in performing safeguards verification measurements of these AR fuels (both fresh and spent fuels) in advance of the widespread adoption of these new fuel types, because new safeguards technologies can take several years to develop, test, and approve for use. This report documents work performed in fiscal year 2024 based on modeling and simulation to assess the performance of the existing safeguards measurement technologies for irradiated or spent AR fuel elements or items. This work is a continuation of the work performed in fiscal year 2023 that focused on fresh AR fuels. Spent AR fuels have a distinct difference from their LWR counterparts: unlike the spent LWR fuels typically stored in a water-filled pool, some spent AR fuels—such as tristructural-isotropic (TRISO)-based fuels—will most likely be stored in air-filled hot cells. Because most safeguards measurements on spent fuel performed to date have been conducted under water, the air-filled hot cell environment could present unique challenges to safeguards measurements. Fork detector (FDET) and Cerenkov viewing device (CVD) systems have been the two primary instruments used by the IAEA for several decades to measure spent LWR fuel assemblies stored in pools for safeguards verification purposes. Because the lower refractive index of air causes Cerenkov light to be of lower intensity in air than in water, existing CVDs are likely unable to perform safeguards verification measurements for spent fuel stored in an air-filled hot cell, as is the case for the TRISO-based spent fuel elements (e.g., pebbles, graphite fuel blocks). Unlike FDET measurements, CVD measurements do not require fuel be moved, so they are a simpler and faster to take than FDET measurements. The inability to perform CVD measurements on the TRISO-based AR fuel types presents a major technical challenge in the effort to use existing technology to perform safeguards measurements on spent AR fuels. This study was mainly conducted through the modeling and simulation of an FDET or an FDET-like system on five spent AR fuel types, including one metallic fuel type and four TRISO-based fuel types in both pebble and graphite block forms in their respective storage configurations and environments. Because the various AR fuel types have significantly different dimensions, FDET systems must be adapted to accommodate them. Partial defect tests were also simulated in this study to assess the FDET’s ability to detect potential fuel diversions. The FDET measures the fuel’s total passive neutron and gamma emissions. The simulated FDET results from spent AR fuel items are compared against results from a typical spent pressurized water reactor (PWR) assembly. High-purity germanium (HPGe) gamma detector measurements were also simulated for the spent AR fuel types and the PWR assembly because the signature photopeaks have been used in LWR safeguards verifications, although HPGe is usually not used to detect diversions because of the fuel’s self-attenuation effects on those photopeaks. The results indicate that these detectors have significant challenges in performing safeguards measurements of the spent AR fuel items, including incompatibilities between AR fuel items and existing FDETs, lower neutron count rates, lower sensitivities to fuel diversions in certain AR fuel items, and significantly higher interference from a neighboring fuel item when the measurement is performed in air. These results suggest that an alternative technology or significant and timely technology development is needed to perform adequate safeguards measurements of some of these AR fuel items.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

β decay of neutron-rich 76 Cu and the structure of 76 Zn

In this work, the β decay of 76 Cu to the levels of 76 Zn was studied at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab (ORNL). A purified 76 Cu beam was developed and data were recorded for the decay of the A=76 decay chain using four high-purity germanium (HPGe) clover detectors at the Low-energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS). In this measurement, data on γ-ray emission following β decay, including βγ and γγ coincidences, were collected and γγ spectra were analyzed to identify the statistically significant coincidences. From this analysis, we propose a level scheme for 76 Zn which contains a total of 59 energy levels up to 6.0 MeV containing 105 γ rays. We have identified an additional 53 γ rays associated with this decay which could not be place in the decay scheme due to insufficient coincidence information or no energy match to identified levels. No γ rays from states in 75 Zn fed in the delayed-neutron branch were observed even though other γ rays in the A=75 decay chain were observed. Spin and parity assignments are proposed for some levels based on comparison to systematics and shell model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A field-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt γ-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium γ-ray detector. Fine spatial resolution neutron and α detectors enable precise mapping of characteristic γ-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus significantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

Bucher, Brian [Idaho National Laboratory (INL)]↗

Application of Hybrid K-Edge Densitometry in Reprocessing Facilities

During reprocessing operations, accurately determining the elemental concentrations of uranium and plutonium is critical for nuclear security. Reprocessing facilities processes hundreds of tons of nuclear material annually, requiring accurate measurements to ensure effective nuclear material control and accountability. Hybrid K-edge densitometry (HKED) system combines K-edge absorption densitometry with x-ray fluorescence to measure actinide elemental concentrations with a low uncertainty. This system uses high-purity germanium gamma-ray detectors and advanced signal processing equipment to detect x-ray accurately. This document provides guidance on how to achieve effective performance from an HKED system for measuring uranium and plutonium concentrations in reprocessing facilities. It includes best practices for the setup and operation of an HKED system, while highlighting factors influencing uncertainties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assembly and Initial Testing of the Gamma-Ray Emission Tomography Assessment Prototype for Irradiated Fuel

The following report documents the final development, assembly, and initial testing of the gamma-ray emission tomography assessment system (GRETA-1) for post-irradiation examination of irradiated fuel. It includes descriptions of the system components, including the high-purity germanium gamma-ray detector, the surrounding shield and collimator, the sample scanning hardware, and the control and collection software package. A series of MCNP6 simulations were performed that modeled a fuel rod scan to test image reconstruction algorithms with a complex and understood source distribution. A bench-top scan of isotopic check sources was also performed and analyzed using standard image reconstruction algorithms. The system is currently awaiting deployment at Idaho National Laboratory’s Hot Fuel Examination Facility.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Investigating Influential Parameters for High-Purity Germanium Crystal Growth

This paper focuses on the research and development of high-purity germanium (HPGe) crystals for detector fabrication, specifically targeting applications in rare-event physics searches. The primary objective was to produce large-scale germanium crystals weighing >1 kg with a controlled diameter of ∼10 cm and an impurity range of approximately 1010/cm 3. Ensuring structural integrity and excellent crystalline quality requires a thorough assessment of dislocation density, a critical aspect of the crystal development process. Dislocation density measurements play a crucial role in maximizing the sensitivity of HPGe detectors, and our findings confirmed that the dislocation density fell within acceptable ranges for detector fabrication. Additionally, this paper examines the segregation coefficient of various contaminants during the crystal development process. Comprehensive analysis of impurity segregation is essential for reducing contaminant quantities in the crystal lattice and customizing purification processes. This, in turn, minimizes undesired background noise, enhancing signal-to-noise ratios for rare-event physics searches and overall detector performance. The investigation included the segregation coefficients of three major acceptors and one donor in crystals grown at the University of South Dakota, providing valuable insights for optimizing crystal purity and detector efficiency.

Bhattarai, Sanjay↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

Monte Carlo Analysis of Coolant Stream Impurity Gamma Emissions in Gas-Cooled Fast Reactors

It is well established that a rapid increase in the concentration of fission products in the reactor coolant stream can serve as an early indication of fuel failure. We use Monte Carlo simulations to investigate the feasibility of using several gamma detectors as diagnostic equipment to monitor the presence of major fission product isotopes in high-temperature gas-cooled reactor (HTGR) coolant streams for early detection of fuel failure and therefore the prevention of fuel failure conditions. Herein we model the response of high-purity germanium (HPGe), CdZnTe, NaI(Tl), and LaBr 3 (Ce) detectors of typical commercial sizes to the gamma emissions from nuclides expected to be found within the coolant stream of the Versatile Test Reactor (VTR) under development by the U.S. Department of Energy. The results indicate that for the 233- and 250-keV gamma rays from 133 Xe and 135 Xe, respectively, the 3σ detection criterion is met in under 1 min using a single HPGe detector. Changes in other spectral lines associated with Xe nuclides are detected within 1 h regardless of the choice of detector.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FRAM v.7.1

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr3) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

07 ISOTOPE AND RADIATION SOURCES↗

24.1.3.4 Upgraded Fixed Energy Response Function Analysis with Multiple Efficiencies (FRAM) Software for U/Pu/MOX Mass Measurements

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr 3 ) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray Spectroscopy in Low-Power Nuclear Research Reactors

Gamma-ray spectroscopy is an effective technique for radioactive material characterization, routine inventory verification, nuclear safeguards, health physics, and source search scenarios. Gamma-ray spectrometers typically cannot be operated in the immediate vicinity of nuclear reactors due to their high flux fields and their resulting inability to resolve individual pulses. Low-power reactor facilities offer the possibility to study reactor gamma-ray fields, a domain of experiments hitherto poorly explored. In this work, we present gamma-ray spectroscopy experiments performed with various detectors in two reactors: The EPFL zero-power research reactor CROCUS, and the neutron beam facility at the Ohio State University Research Reactor (OSURR). We employed inorganic scintillators (CeBr3), organic scintillators (trans-stilbene and organic glass), and high-purity germanium semiconductors (HPGe) to cover a range of typical—and new—instruments used in gamma-ray spectroscopy. The aim of this study is to provide a guideline for reactor users regarding detector performance, observed responses, and therefore available information in the reactor photon fields up to 2 MeV. The results indicate several future prospects, such as the online (at criticality) monitoring of fission products (like Xe, I, and La), dual-particle sensitive experiments, and code validation opportunities.

Pakari, Oskari V. (ORCID:0000000337048190)↗

Low-energy solar neutrino detection utilizing advanced germanium detectors

We explore the possibility to use advanced germanium (Ge) detectors as a low-energy solar neutrino observatory by means of neutrino-nucleus elastic scattering. A Ge detector utilizing internal charge amplification for the charge carriers created by the ionization of impurities is a novel technology with experimental sensitivity for detecting low-energy solar neutrinos. Ge internal charge amplification (GeICA) detectors will amplify the charge carriers induced by neutrino interacting with Ge atoms through the emission of phonons. It is those phonons that will create charge carriers through the ionization of impurities to achieve an extremely low energy threshold of ~0.01 eV. We demonstrate the phonon absorption, excitation, and ionization probability of impurities in a Ge detector with impurity levels of 3 × 10 10 cm -3 , 9 × 10 10 cm -3 , and 2 × 10 11 cm -3 . We present the sensitivity of such a Ge experiment for detecting solar neutrinos in the low-energy region. We show that, if GeICA technology becomes available, then a new opportunity arises to observe pp and 7 Be solar neutrinos. Such a novel detector with only 1 kg of high-purity Ge will give ~10 events per year for pp neutrinos and ~5 events per year for 7 Be neutrinos with a detection energy threshold of 0.01 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine learning-powered data cleaning for LEGEND: a semi-supervised approach using affinity propagation and support vector machines

Neutrinoless double-beta decay ($0\nu\beta\beta$) is a rare nuclear process that, if observed, will provide insight into the nature of neutrinos and help explain the matter-antimatter asymmetry in the Universe. The large enriched germanium experiment for neutrinoless double-beta decay (LEGEND) will operate in two phases to search for $0\nu\beta\beta$. The first (second) stage will employ 200 (1000) kg of High-Purity Germanium (HPGe) enriched in 76 Ge to achieve a half-life sensitivity of 10 27 (10 28 ) years. In this study, we present a semi-supervised data-driven approach to remove non-physical events captured by HPGe detectors powered by a novel artificial intelligence model. We utilize affinity propagation to cluster waveform signals based on their shape and a support vector machine to classify them into different categories. We train, optimize, and test our model on data taken from a natural abundance HPGe detector installed in the Full Chain Test experimental stand at the University of North Carolina at Chapel Hill. We demonstrate that our model yields a maximum sacrifice of physics events of $0.024 ^{+0.004}_{-0.003} \%$ after data cleaning. Our model is being used to accelerate data cleaning development for LEGEND-200 and will serve to improve data cleaning procedures for LEGEND-1000.

artificial intelligence↗

Measurement of Ionization Produced by 254 eVnr Nuclear Recoils in Germanium

Ionization produced by low-energy nuclear recoils is among the primary direct signatures of dark matter interactions. Despite the urgency of dark matter detection and the recent measurements of coherent elastic neutrino-nucleus scattering, detector response to nuclear recoils is not well characterized in the keVnr and sub-keVnr regime across a variety of materials. We have re-performed a measurement of the ionization produced by monoenergetic 254 eVnr nuclear recoils in Ge with improved digital electronics and additional systematic studies. Our results indicate an ionization yield of 64 +/- 8 eVee corresponding to a quenching factor of 25 +/- 3%, greater than the 14% predicted by the Lindhard model. This ionization enhancement could greatly improve the sensitivity of high-purity Ge detectors in dark matter detection and measurement of neutrinos via coherent scattering.

Kavner, Alexander R.↗